7 resultados para Portable equipment.
em Repositório Científico do Instituto Politécnico de Lisboa - Portugal
Resumo:
Trabalho Final de Mestrado para obtenção do grau de Mestre em Engenharia Mecânica
Resumo:
Certain environmental conditions in animal and plant production have been associated with increased frequency in respiratory illnesses, including asthma, chronic bronchitis, and hypersensitivity pneumonitis, in farmers occupationally exposed in swine production. The aim of this study was to characterize particulate matter (PM) contamination in seven Portuguese swine farms and determine the existence of clinical symptoms associated with asthma and other allergy diseases, utilizing the European Community Respiratory Health Survey questionnaire. Environmental assessments were performed with portable direct-reading equipment, and PM contamination including five different sizes (PM0.5, PM1.0, PM2.5, PM5.0, PM10) was determined. The distribution of particle size showed the same trend in all swine farms, with high concentrations of particles with PM5 and PM10. Results from the questionnaire indicated a trend such that subjects with diagnosis of asthma were exposed to higher concentrations of PM with larger size (PM2.5, PM5, and PM10) while subjects with sneezing, runny nose, or stuffy nose without a cold or flu were exposed to higher concentrations of PM with smaller size (PM0.5 and PM1). Data indicate that inhalation of PM in swine farm workers is associated with increased frequency of respiratory illnesses.
Resumo:
The presence of filamentous fungi was detected in wastewater and air collected at wastewater treatment plants (WWTP) from several European countries. The aim of the present study was to assess fungal contamination in two WWTP operating in Lisbon. In addition, particulate matter (PM) contamination data was analyzed. To apply conventional methods, air samples from the two plants were collected through impaction using an air sampler with a velocity air rate of 140 L/min. Surfaces samples were collected by swabbing the surfaces of the same indoor sites. All collected samples were incubated at 27°C for 5 to 7 d. After lab processing and incubation of collected samples, quantitative and qualitative results were obtained with identification of the isolated fungal species. For molecular methods, air samples of 250 L were also collected using the impinger method at 300 L/min airflow rate. Samples were collected into 10 ml sterile phosphate-buffered saline with 0.05% Triton X-100, and the collection liquid was subsequently used for DNA extraction. Molecular identification of Aspergillus fumigatus and Stachybotrys chartarum was achieved by real-time polymerase chain reaction (RT-PCR) using the Rotor-Gene 6000 qPCR Detection System (Corbett). Assessment of PM was also conducted with portable direct-reading equipment (Lighthouse, model 3016 IAQ). Particles concentration measurement was performed at five different sizes: PM0.5, PM1, PM2.5, PM5, and PM10. Sixteen different fungal species were detected in indoor air in a total of 5400 isolates in both plants. Penicillium sp. was the most frequently isolated fungal genus (58.9%), followed by Aspergillus sp. (21.2%) and Acremonium sp. (8.2%), in the total underground area. In a partially underground plant, Penicillium sp. (39.5%) was also the most frequently isolated, also followed by Aspergillus sp. (38.7%) and Acremonium sp. (9.7%). Using RT-PCR, only A. fumigatus was detected in air samples collected, and only from partial underground plant. Stachybotrys chartarum was not detected in any of the samples analyzed. The distribution of particle sizes showed the same tendency in both plants; however, the partially underground plant presented higher levels of contamination, except for PM2.5. Fungal contamination assessment is crucial to evaluating the potential health risks to exposed workers in these settings. In order to achieve an evaluation of potential health risks to exposed workers, it is essential to combine conventional and molecular methods for fungal detection. Protective measures to minimize worker exposure to fungi need to be adopted since wastewater is the predominant internal fungal source in this setting.
Resumo:
Sampling the total air concentration of particulate matter (PM) only provides a basic estimate of exposure that normally not allows correlating with the observed health effects. Therefore is of great importance to recognize the particles size distribution and, particularly, the exposure to fine particles (≤ 2.5 μm). This particles dimension corresponds to the respirable fraction, the one that can implicate local and systemic effects due to particle deposition and clearance from the lungs and transport within the organism. This study intended to describe occupational exposure to PM2.5 in three units related with swine production and consumption, namely: feed production, swine production and swine slaughterhouse. A size-selective particle measuring in five to six workplaces of each unit was performed. Measurements of PM were done using a portable direct-reading hand-held equipment (Lighthouse, model 3016 IAQ). Data showed slaughterhouse unit with higher values, with values ranging from 0.030 to 0.142 mg/m3 (0.073 + 0.043), being the cutting room the workplace with higher values. In feed production unit, values were between 0.026 and 0.033 mg/m3 (0.028 + 0.003) with the warehouse of pharmacy products as the workplace with higher values. Finally, in swine unit values ranged from 0.006 to 0.048 mg/m3 (0.023 + 0.017) with the batteries area presenting the higher values. PM can be rich in fungi and bacteria and their metabolites, such as endotoxins and mycotoxins. Previous publications already showed high contamination in these occupational settings and particles can have an important role in exposure since can easily act as carrier of these agents. Data acquired allow not only a better prediction of particle penetration into respiratory regions of the respiratory tract, but also a better estimation of PM health effects. Moreover, data permit to identify the workplaces where investment should be made to prevent and reduce exposure.
Resumo:
Occupational exposure assessment can be a challenge due to several factors being the most important the costs associate and the result's dependence from the conditions at the time of sampling. Conducting a task-based exposure assessment allow defining better control measures to eliminate or reduce exposure since more easily identifies the task with higher exposure. A research study was developed to show the importance of task-based exposure assessment in four different settings (bakery, horsemanship, waste sorting and cork industry). Measurements were performed using a portable direct-reading hand-held equipment and were conducted near the workers nose during tasks performance. For each task were done measurements of approximately 5 minutes. It was possible to detect the task in each setting that was responsible for higher particles exposure allowing the priority definition regarding investments in preventive and protection measures.
Resumo:
Mammography equipment must be evaluated to ensure that images will be of acceptable diagnostic quality with lowest radiation dose. Quality Assurance (QA) aims to provide systematic and constant improvement through a feedback mechanism to address the technical, clinical and training aspects. Quality Control (QC), in relation to mammography equipment, comprises a series of tests to determine equipment performance characteristics. The introduction of digital technologies promoted changes in QC tests and protocols and there are some tests that are specific for each manufacturer. Within each country specifi c QC tests should be compliant with regulatory requirements and guidance. Ideally, one mammography practitioner should take overarching responsibility for QC within a service, with all practitioners having responsibility for actual QC testing. All QC results must be documented to facilitate troubleshooting, internal audit and external assessment. Generally speaking, the practitioner’s role includes performing, interpreting and recording the QC tests as well as reporting any out of action limits to their service lead. They must undertake additional continuous professional development to maintain their QC competencies. They are usually supported by technicians and medical physicists; in some countries the latter are mandatory. Technicians and/or medical physicists often perform many of the tests indicated within this chapter. It is important to recognise that this chapter is an attempt to encompass the main tests performed within European countries. Specific tests related to the service that you work within must be familiarised with and adhered too.
Resumo:
Mammography is one of the most technically demanding examinations in radiology, and it requires X-ray technology designed specifi cally for the task. The pathology to be imaged ranges from small (20–100 μm) high density microcalcifications to ill-defi ned low contrast masses. These must be imaged against a background of mixed densities. This makes demonstrating pathology challenging. Because of its use in asymptomatic screening, mammography must also employ as low a radiation dose as possible.