7 resultados para Pelvic Aspiration
em Repositório Científico do Instituto Politécnico de Lisboa - Portugal
Resumo:
: A new active-contraction visco-elastic numerical model of the pelvic floor (skeletal) muscle is presented. Our model includes all elements that represent the muscle constitutive behavior, contraction and relaxation. In contrast with the previous models, the activation function can be null. The complete equations are shown and exactly linearized. Small verification and validation tests are performed and the pelvis is modeled using the data from the intra-abdominal pressure tests
Resumo:
Introduction: The samples obtained from fine needle aspiration in liquid base cytology (FNAC) are often limited by scarce cellularity compared to the amount of colloid and presence of blood. Accordingly, it was important to test alternative technical procedures so as to maximize the cellularity of each sample. Objective: To compare the morphological features and cellularity of the three procedures in the FNAC cytodiagnosis of the thyroid. Methods: A total of 31 cases were each subjected to a cell block and ThinPrep preparation as well as a routine smear. The observation and analysis was performed using an optical microscope. Cytological diagnosis of each cell block case was objectively analysed for cellularity, presence of background and cellular preservation. Each smear and ThinPrep case was analysed for the presence or absence of cells. The data was analysed with Microsoft Excel (Office 2010) and SPSS (Statistical Package of Social Science) version 15.0 for Windows. Results: Of 31 cases, only 20 had thyroid cells in the cell block and ThinPrep preparations, however, all smear cases contained thyroid cells. Some background was found in 30 Cell block cases with only 5 of these containing well preserved cells for cytodiagnosis. Conclusions: As indicated by the results, smear is the most appropriate procedure for FNAC of the thyroid.
Resumo:
Mestrado em Tecnologia de Diagnóstico e Intervenção Cardiovascular. Área de especialização: Intervenção Cardiovascular.
Resumo:
Aim - A quantative primary study to determine whether increasing source to image distance (SID), with and without the use of automatic exposure control (AEC) for antero-posterior (AP) pelvis imaging, reduces dose whilst still producing an image of diagnostic quality. Methods - Using a computed radiography (CR) system, an anthropomorphic pelvic phantom was positioned for an AP examination using the table bucky. SID was initially set at 110 cm, with tube potential set at a constant 75 kVp, with two outer chambers selected and a fine focal spot of 0.6 mm. SID was then varied from 90 cm to 140 cm with two exposures made at each 5 cm interval, one using the AEC and another with a constant 16 mAs derived from the initial exposure. Effective dose (E) and entrance surface dose (ESD) were calculated for each acquisition. Seven experienced observers blindly graded image quality using a 5-point Likert scale and 2 Alternative Forced Choice software. Signal-to-Noise Ratio (SNR) was calculated for comparison. For each acquisition, femoral head diameter was also measured for magnification indication. Results - Results demonstrated that when increasing SID from 110 cm to 140 cm, both E and ESD reduced by 3.7% and 17.3% respectively when using AEC and 50.13% and 41.79% respectively, when the constant mAs was used. No significant statistical (T-test) difference (p = 0.967) between image quality was detected when increasing SID, with an intra-observer correlation of 0.77 (95% confidence level). SNR reduced slightly for both AEC (38%) and no AEC (36%) with increasing SID. Conclusion - For CR, increasing SID significantly reduces both E and ESD for AP pelvis imaging without adversely affecting image quality.
Resumo:
Mestrado em Radiações Aplicadas às tecnologias da Saúde
Resumo:
Mestrado em Radioterapia
Resumo:
Mestrado em Radioterapia