18 resultados para Nanometric displacement measurements

em Repositório Científico do Instituto Politécnico de Lisboa - Portugal


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Measurements in civil engineering load tests usually require considerable time and complex procedures. Therefore, measurements are usually constrained by the number of sensors resulting in a restricted monitored area. Image processing analysis is an alternative way that enables the measurement of the complete area of interest with a simple and effective setup. In this article photo sequences taken during load displacement tests were captured by a digital camera and processed with image correlation algorithms. Three different image processing algorithms were used with real images taken from tests using specimens of PVC and Plexiglas. The data obtained from the image processing algorithms were also compared with the data from physical sensors. A complete displacement and strain map were obtained. Results show that the accuracy of the measurements obtained by photogrammetry is equivalent to that from the physical sensors but with much less equipment and fewer setup requirements. © 2015Computer-Aided Civil and Infrastructure Engineering.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Low noise surfaces have been increasingly considered as a viable and cost-effective alternative to acoustical barriers. However, road planners and administrators frequently lack information on the correlation between the type of road surface and the resulting noise emission profile. To address this problem, a method to identify and classify different types of road pavements was developed, whereby near field road noise is analyzed using statistical learning methods. The vehicle rolling sound signal near the tires and close to the road surface was acquired by two microphones in a special arrangement which implements the Close-Proximity method. A set of features, characterizing the properties of the road pavement, was extracted from the corresponding sound profiles. A feature selection method was used to automatically select those that are most relevant in predicting the type of pavement, while reducing the computational cost. A set of different types of road pavement segments were tested and the performance of the classifier was evaluated. Results of pavement classification performed during a road journey are presented on a map, together with geographical data. This procedure leads to a considerable improvement in the quality of road pavement noise data, thereby increasing the accuracy of road traffic noise prediction models.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Solubilities of three primary amides, namely, acetanilide, propanamide, and butanamide, in supercritical carbon dioxide were measured at T = (308.2, 313.2, and 323.2) K over the pressure range (9.0 to 40.0) MPa by a flow type apparatus. The solubility behavior of the three solids shows an analogous trend with a crossover region of the respective isotherms between (12 to 14) MPa. The solubility of each amide, at the same temperature and pressure, decreases from propanamide to acetanilide. Pure compound properties required for the modeling were estimated, and the solubilities of the amides were correlated by using the Soave-Redlich-Kwong cubic equation of state with an absolute average relative deviation (AARD) from (1.3 to 6.1) %.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ballet gestures are highly non-anatomical and physiological, leading to compensatory behaviors. The knee joint is most affected by this behavior, leading to an increase risk of injury. Our purpose is to describe the knee angular displacement in amateur dancers, during a demi-plié exercise, with emphasis on valgus mechanisms frequency. Methods: 192 demi-pliés collected in six amateur female dancers (mean age = 15.33 ± 1.37 years), were analyzed regarding sagittal and frontal plane angular displacement, with an electrogoniometer connected to a signal acquisition unit at 1000 Hz. Results: all subjects presented valgus peaks along the trials, despite the global varus tendency of the knee frontal plane behavior. A significant positive correlation between the frequency of valgus and practice time was noted. Discussion: A variable angular frontal displacement was observed, with some trials comprehending a high incidence of valgus peaks along the ascending or descending phase of the demi-plié exercise. Conclusion: the frontal knee angle behavior is variable. It may present fast peaks of valgus or an initial trend of varus/valgus that is different from the global varus trend. The analysis of the activity should be considered in the training. The practice time may be related to the observed behavior.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: The most recent Varian® micro multileaf collimator(MLC), the High Definition (HD120) MLC, was modeled using the BEAMNRCMonte Carlo code. This model was incorporated into a Varian medical linear accelerator, for a 6 MV beam, in static and dynamic mode. The model was validated by comparing simulated profiles with measurements. Methods: The Varian® Trilogy® (2300C/D) accelerator model was accurately implemented using the state-of-the-art Monte Carlo simulation program BEAMNRC and validated against off-axis and depth dose profiles measured using ionization chambers, by adjusting the energy and the full width at half maximum (FWHM) of the initial electron beam. The HD120 MLC was modeled by developing a new BEAMNRC component module (CM), designated HDMLC, adapting the available DYNVMLC CM and incorporating the specific characteristics of this new micro MLC. The leaf dimensions were provided by the manufacturer. The geometry was visualized by tracing particles through the CM and recording their position when a leaf boundary is crossed. The leaf material density and abutting air gap between leaves were adjusted in order to obtain a good agreement between the simulated leakage profiles and EBT2 film measurements performed in a solid water phantom. To validate the HDMLC implementation, additional MLC static patterns were also simulated and compared to additional measurements. Furthermore, the ability to simulate dynamic MLC fields was implemented in the HDMLC CM. The simulation results of these fields were compared with EBT2 film measurements performed in a solid water phantom. Results: Overall, the discrepancies, with and without MLC, between the opened field simulations and the measurements using ionization chambers in a water phantom, for the off-axis profiles are below 2% and in depth-dose profiles are below 2% after the maximum dose depth and below 4% in the build-up region. On the conditions of these simulations, this tungsten-based MLC has a density of 18.7 g cm− 3 and an overall leakage of about 1.1 ± 0.03%. The discrepancies between the film measured and simulated closed and blocked fields are below 2% and 8%, respectively. Other measurements were performed for alternated leaf patterns and the agreement is satisfactory (to within 4%). The dynamic mode for this MLC was implemented and the discrepancies between film measurements and simulations are within 4%. Conclusions: The Varian® Trilogy® (2300 C/D) linear accelerator including the HD120 MLC was successfully modeled and simulated using the Monte CarloBEAMNRC code by developing an independent CM, the HDMLC CM, either in static and dynamic modes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: The effect of the intake of polynsaturated long chain fatty acids (LCPUFAs) during pregnancy on fetal body composition has been assessed by studies using mostly neonatal anthropometry. Their results have been inconsistent, probably because neonatal anthropometry has several validity limitations. Air displacement plethismography (ADP) is a recently validated non-invasive method for assessing body composition in neonates. Objective: To determine the effect of the intake of LCPUFAs during pregnancy on the body composition of term neonates, measured by ADP. Methods: Cross-sectional study of a convenience sample of healthy full-term neonates and their mothers. The diet during pregnancy was assessed using a validated semi-quantitative food frequency questionnaire; Food Processor Plus® was used to convert food intake into nutritional values. Body composition was estimated by anthropometry and measured by ADP using Pea Pod™ Life Measurements Inc (fat mass - FM, fat-free mass and %FM) within the first 72h after birth. Univariate and multivariate analysis (linear regression model) were performed. Results: 54 mother-neonate pairs were included. Multivariate analysis adjusted to the maternal body mass index shows positive association between LCPUFAs intake and neonatal mid-arm circumference (= 0,610, p = 0,019) and negative association between n-6:n-3 ratio intake and neonatal %FM (= -2,744, p=0,066). Conclusion: To the best of our knowledge, this is the first study on this subject using ADP and showing a negative association between LCPUFAs n-6:n-3 ratio intake in pregnancy and neonatal %FM. This preliminary finding requires confirmation increasing the study power with a greater sample and performing interventional studies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective - The adjusted effect of long-chain polyunsaturated fatty acid (LCPUFA) intake during pregnancy on adiposity at birth of healthy full-term appropriate-for-gestational age neonates was evaluated. Study Design - In a cross-sectional convenience sample of 100 mother and infant dyads, LCPUFA intake during pregnancy was assessed by food frequency questionnaire with nutrient intake calculated using Food Processor Plus. Linear regression models for neonatal body composition measurements, assessed by air displacement plethysmography and anthropometry, were adjusted for maternal LCPUFA intakes, energy and macronutrient intakes, prepregnancy body mass index and gestational weight gain. Result - Positive associations between maternal docosahexaenoic acid intake and ponderal index in male offspring (β=0.165; 95% confidence interval (CI): 0.031–0.299; P=0.017), and between n-6:n-3 LCPUFA ratio intake and fat mass (β=0.021; 95% CI: 0.002–0.041; P=0.034) and percentage of fat mass (β=0.636; 95% CI: 0.125–1.147; P=0.016) in female offspring were found. Conclusion - Using a reliable validated method to assess body composition, adjusted positive associations between maternal docosahexaenoic acid intake and birth size in male offspring and between n-6:n-3 LCPUFA ratio intake and adiposity in female offspring were found, suggesting that maternal LCPUFA intake strongly influences fetal body composition.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Intensity Modulated Radiotherapy (IMRT) is a technique introduced to shape more precisely the dose distributions to the tumour, providing a higher dose escalation in the volume to irradiate and simultaneously decreasing the dose in the organs at risk which consequently reduces the treatment toxicity. This technique is widely used in prostate and head and neck (H&N) tumours. Given the complexity and the use of high doses in this technique it’s necessary to ensure as a safe and secure administration of the treatment, through the use of quality control programmes for IMRT. The purpose of this study was to evaluate statistically the quality control measurements that are made for the IMRT plans in prostate and H&N patients, before the beginning of the treatment, analysing their variations, the percentage of rejected and repeated measurements, the average, standard deviations and the proportion relations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Trabalho Final de Mestrado elaborado no Laboratório Nacional de Engenharia Civil (LNEC) para a obtenção do grau de Mestre em Engenharia Civil pelo Instituto Superior de Engenharia de Lisboa no âmbito do protocolo de cooperação entre o ISEL e o LNEC

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The article reports density measurements of dipropyl (DPA), dibutyl (DBA) and bis(2-ethylhexyl) (DEHA) adipates, using a vibrating U-tube densimeter, model DMA HP, from Anton Paar GmbH. The measurements were performed in the temperature range (293 to 373) K and at pressures up to about 68 MPa, except for DPA for which the upper limits were 363 K and 65 MPa, respectively. The density data for each liquid was correlated with the temperature and pressure using a modified Tait equation. The expanded uncertainty of the present density results is estimated as 0.2% at a 95% confidence level. No literature density data at pressures higher than 0.1 MPa could be found. DEHA literature data at atmospheric pressure agree with the correlation of the present measurements, in the corresponding temperature range, within +/- 0.11%. The isothermal compressibility and the isobaric thermal expansion were calculated by differentiation of the modified Tait correlation equation. These two parameters were also calculated for dimethyl adipate (DMA), from density data reported in a previous work. The uncertainties of isothermal compressibility and the isobaric thermal expansion are estimated to be less than +/- 1.7% and +/- 1.1%, respectively, at a 95% confidence level. Literature data of isothermal compressibility and isobaric thermal expansivity for DMA have an agreement within +/- 1% and +/- 2.4%, respectively, with results calculated in this work. (C) 2014 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

No literature data above atmospheric pressure could be found for the viscosity of TOTIVI. As a consequence, the present viscosity results could only be compared upon extrapolation of the vibrating wire data to 0.1 MPa. Independent viscosity measurements were performed, at atmospheric pressure, using an Ubbelohde capillary in order to compare with the vibrating wire results, extrapolated by means of the above mentioned correlation. The two data sets agree within +/- 1%, which is commensurate with the mutual uncertainty of the experimental methods. Comparisons of the literature data obtained at atmospheric pressure with the present extrapolated vibrating-wire viscosity measurements have shown an agreement within +/- 2% for temperatures up to 339 K and within +/- 3.3% for temperatures up to 368 K. (C) 2014 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In Part I of the present work we describe the viscosity measurements performed on tris(2-ethylhexyl) trimellitate or 1,2,4-benzenetricarboxylic acid, tris(2-ethylhexyl) ester (TOTM) up to 65 MPa and at six temperatures from (303 to 373)K, using a new vibrating-wire instrument. The main aim is to contribute to the proposal of that liquid as a potential reference fluid for high viscosity, high pressure and high temperature. The present Part II is dedicated to report the density measurements of TOTM necessary, not only to compute the viscosity data presented in Part I, but also as complementary data for the mentioned proposal. The present density measurements were obtained using a vibrating U-tube densimeter, model DMA HP, using model DMA5000 as a reading unit, both instruments from Anton Paar GmbH. The measurements were performed along five isotherms from (293 to 373)K and at eleven different pressures up to 68 MPa. As far as the authors are aware, the viscosity and density results are the first, above atmospheric pressure, to be published for TOTM. Due to TOTM's high viscosity, its density data were corrected for the viscosity effect on the U-tube density measurements. This effect was estimated using two Newtonian viscosity standard liquids, 20 AW and 200 GW. The density data were correlated with temperature and pressure using a modified Tait equation. The expanded uncertainty of the present density results is estimated as +/- 0.2% at a 95% confidence level. Those results were correlated with temperature and pressure by a modified Tait equation, with deviations within +/- 0.25%. Furthermore, the isothermal compressibility, K-T, and the isobaric thermal expansivity, alpha(p), were obtained by derivation of the modified Tait equation used for correlating the density data. The corresponding uncertainties, at a 95% confidence level, are estimated to be less than +/- 1.5% and +/- 1.2%, respectively. No isobaric thermal expansivity and isothermal compressibility for TOTM were found in the literature. (C) 2014 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The erosion depth profile of planar targets in balanced and unbalanced magnetron cathodes with cylindrical symmetry is measured along the target radius. The magnetic fields have rotational symmetry. The horizontal and vertical components of the magnetic field B are measured at points above the cathode target with z = 2 x 10(-3) m. The experimental data reveal that the target erosion depth profile is a function of the angle. made by B with a horizontal line defined by z = 2 x 10(-3) m. To explain this dependence a simplified model of the discharge is developed. In the scope of the model, the pathway lengths of the secondary electrons in the pre-sheath region are calculated by analytical integration of the Lorentz differential equations. Weighting these lengths by using the distribution law of the mean free path of the secondary electrons, we estimate the densities of the ionizing events over the cathode and the relative flux of the sputtered atoms. The expression so deduced correlates for the first time the erosion depth profile of the target with the angle theta. The model shows reasonably good fittings to the experimental target erosion depth profiles confirming that ionization occurs mainly in the pre-sheath zone.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This review aims to identify strategies to optimise radiography practice using digital technologies, for full spine studies on paediatrics focusing particularly on methods used to diagnose and measure severity of spinal curvatures. The literature search was performed on different databases (PubMed, Google Scholar and ScienceDirect) and relevant websites (e.g., American College of Radiology and International Commission on Radiological Protection) to identify guidelines and recent studies focused on dose optimisation in paediatrics using digital technologies. Plain radiography was identified as the most accurate method. The American College of Radiology (ACR) and European Commission (EC) provided two guidelines that were identified as the most relevant to the subject. The ACR guidelines were updated in 2014; however these guidelines do not provide detailed guidance on technical exposure parameters. The EC guidelines are more complete but are dedicated to screen film systems. Other studies provided reviews on the several exposure parameters that should be included for optimisation, such as tube current, tube voltage and source-to-image distance; however, only explored few of these parameters and not all of them together. One publication explored all parameters together but this was for adults only. Due to lack of literature on exposure parameters for paediatrics, more research is required to guide and harmonise practice.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim: Optimise a set of exposure factors, with the lowest effective dose, to delineate spinal curvature with the modified Cobb method in a full spine using computed radiography (CR) for a 5-year-old paediatric anthropomorphic phantom. Methods: Images were acquired by varying a set of parameters: positions (antero-posterior (AP), posteroanterior (PA) and lateral), kilo-voltage peak (kVp) (66-90), source-to-image distance (SID) (150 to 200cm), broad focus and the use of a grid (grid in/out) to analyse the impact on E and image quality (IQ). IQ was analysed applying two approaches: objective [contrast-to-noise-ratio/(CNR] and perceptual, using 5 observers. Monte-Carlo modelling was used for dose estimation. Cohen’s Kappa coefficient was used to calculate inter-observer-variability. The angle was measured using Cobb’s method on lateral projections under different imaging conditions. Results: PA promoted the lowest effective dose (0.013 mSv) compared to AP (0.048 mSv) and lateral (0.025 mSv). The exposure parameters that allowed lower dose were 200cm SID, 90 kVp, broad focus and grid out for paediatrics using an Agfa CR system. Thirty-seven images were assessed for IQ and thirty-two were classified adequate. Cobb angle measurements varied between 16°±2.9 and 19.9°±0.9. Conclusion: Cobb angle measurements can be performed using the lowest dose with a low contrast-tonoise ratio. The variation on measurements for this was ±2.9° and this is within the range of acceptable clinical error without impact on clinical diagnosis. Further work is recommended on improvement to the sample size and a more robust perceptual IQ assessment protocol for observers.