9 resultados para Minimum quantity of fluid
em Repositório Científico do Instituto Politécnico de Lisboa - Portugal
Resumo:
Present paper present the main results obtained in the scope of an ongoing project which aims to contribute to the valorization of a waste generated by the Portuguese oil company in construction materials. This waste is an aluminosilicate with high pozzolanic reactivity. Several different technological applications had already been tested with success both in terms of properties and compliance with the corresponding standards specifications. Namely, this project results already demonstrated that this waste can be used in traditional concrete, self-compacted concrete, mortars (renders, masonry mortar, concrete repair mortars), cement main constituent as well as alkali activated binders.
Resumo:
We show photorheology in aqueous solutions of weakly entangled wormlike micelles prepared with cetyltrimethylammonium bromide (CTAB), salicylic acid (HSal), and dilute amounts of the photochromic multistate compound trans-2,4,4'-trihydroxychalcone (Ct). Different chemical species of Ct are associated with different colorations and propensities to reside within or outside CTAB micelles. A light-induced transfer between the intra- and intermicellar space is used to alter the mean length of wormlike micelles and hence the rheological properties of the fluid, studied in steady-state shear Bow and in dynamic rheological measurements. Light-induced changes of fluid rheology are reversible by a the relaxation process. at relaxation rates which depend on pH and which are consistent with photochromic reversion rates measured by UV-vis absorption spectroscopy. Parameterizing viscoelostic rheological states by their effective relaxation time tau(c) and corresponding response modulus G(c), we find the light and dark states of the system to fall onto a characteristic state curve defined by comparable experiments conducted without photosensitive components. These reference experiments were prepared with the same concentration of CTAB, but different concentrations of HSal or sodium salicylote (NaSal), and tested at different temperatures.
Resumo:
Heart failure is the final stage of most of cardiac diseases. It is a complex syndrome in which the patients should have the following features: symptoms of heart failure, typically shortness of breath at rest or during exertion, and/or fatigue; signs of fluid retention such as pulmonary congestion or ankle swelling; and objective evidence of an abnormality of the structure or function of the heart at rest. This progressive syndrome as a high incidence and prevalence and poor prognosis: four-year mortality is around 50% with 40% of the patients admitted to hospital dying or readmitted within a year. With ageing, many patients will develop chronic heart failure, which, because of its symptoms, patient’s awareness of their risk of dying, and the effects of therapy, together with frequent hospitalizations, has considerable impact on patient’s health-related quality of life.
Resumo:
O principal objectivo desta tese é obter uma relação directa entre a composição dos gases liquefeitos de petróleo (GLP), propano, n-butano e isobutano, usados como aerossóis propulsores numa lata de poliuretano de um componente, com as propriedades das espumas produzidas por spray. As espumas obtidas, terão de ter como requisito principal, um bom desempenho a temperaturas baixas, -10ºC, sendo por isso designadas por espumas de Inverno. Uma espuma é considerada como tendo um bom desempenho se não apresentar a -10/-10ºC (temperatura lata/ spray) glass bubbles, base holes e cell collapse. As espumas deverão ainda ter densidades do spray no molde a +23/+23ºC abaixo dos 30 g/L, um rendimento superior a 30 L, boa estabilidade dimensional e um caudal de espuma a +5/+5ºC superior a 5 g/s. Os ensaios experimentais foram realizados a +23/+23ºC, +5/+5ºC e a -10/-10ºC. A cada temperatura, as espumas desenvolvidas, foram submetidas a testes que permitiram determinar a sua qualidade. Testes esses que incluem os designados por Quick Tests (QT): o spray no papel e no molde das espumas nas referidas temperaturas. As amostras do papel e no molde são especialmente analisadas, quanto, às glass bubbles, cell collapse, base holes, cell structur e, cutting shrinkage, para além de outras propriedades. Os QT também incluem a análise da densidade no molde (ODM) e o estudo do caudal de espumas. Além dos QT foram realizados os testes da estabilidade dimensional das espumas, testes físicos de compressão e adesão, testes de expansão das espumas após spray e do rendimento por lata de espuma. Em todos os ensaios foi utilizado um tubo adaptador colocado na válvula da lata como método de spray e ainda mantida constante a proporção das matérias-primas (excepto os gases, em estudo). As experiências iniciaram-se com o estudo de GLPs presentes no mercado de aerossóis. Estes resultaram que o GLP: propano/ n-butano/ isobutano: (30/ 0/ 70 w/w%), produz as melhores espumas de inverno a -10/-10ºC, reduzindo desta forma as glass bubbles, base holes e o cell collapse produzido pelos restantes GLP usados como aerossóis nas latas de poliuretano. Testes posteriores tiveram como objectivo estudar a influência directa de cada gás, propano, n-butano e isobutano nas espumas. Para tal, foram usadas duas referências do estudo com GLP comercializáveis, 7396 (30 /0 /70 w/w %) e 7442 (0/ 0/ 100 w/w %). Com estes resultados concluí-se que o n-butano produz más propriedades nas espumas a -10/- 10ºC, formando grandes quantidades de glass bubbles, base holes e cell collapse. Contudo, o uso de propano reduz essas glass bubbles, mas em contrapartida, forma cell collapse.Isobutano, porém diminui o cell collapse mas não as glass bubbles. Dos resultados experimentais podemos constatar que o caudal a +5/+5ºC e densidade das espumas a +23/+23ºC, são influenciados pela composição do GLP. O propano e n-butano aumentam o caudal de espuma das latas e a sua densidade, ao contrário com o que acontece com o isobutano. Todavia, pelos resultados obtidos, o isobutano proporciona os melhores rendimentos de espumas por lata. Podemos concluir que os GLPs que contivessem cerca de 30 w/w % de propano (bons caudais a +5/+5ºC e menos glass bubbles a -10/-10ºC), e cerca 70 w/w % de isobutano (bons rendimentos de espumas, bem como menos cell collapse a -10/-10ºC) produziam as melhores espumas. Também foram desenvolvidos testes sobre a influência da quantidade de gás GLP presente numa lata. A análise do volume de GLP usado, foi realizada com base na melhor espuma obtida nos estudos anteriores, 7396, com um GLP (30 / 0/ 70 w/w%), e foram feitas alterações ao seu volume gás GLP presente no pré-polímero. O estudo concluiu, que o aumento do volume pode diminuir a densidade das espumas, e o seu decréscimo, um aumento da densidade. Também indico u que um mau ajuste do volume poderá causar más propriedades nas espumas. A análise económica, concluiu que o custo das espumas com mais GLP nas suas formulações, reduz-se em cerca de 3%, a quando de um aumento do volume de GLP no pré-polímero de cerca de 8 %. Esta diminuição de custos deveu-se ao facto, de um aumento de volume de gás, implicar uma diminuição na quantidade das restantes matérias-primas, com custos superiores, já que o volume útil total da lata terá de ser sempre mantido nos 750 mL. Com o objectivo de melhorar a qualidade da espuma 7396 (30/0/70 w/w %) obtida nos ensaios anteriores adicionou-se à formulação 7396 o HFC-152a (1,1-di fluoroetano). Os resultados demonstram que se formam espumas com más propriedades, especialmente a -10/-10ºC, contudo proporcionou excelentes shaking rate da lata. Através de uma pequena análise de custos não é aconselhável o seu uso pelos resultados obtidos, não proporcionando um balanço custo/benefício favorável. As três melhores espumas obtidas de todos os estudos foram comparadas com uma espuma de inverno presente no mercado. 7396 e 7638 com um volume de 27 % no prépolímero e uma composição de GLP (30/ 0 / 70 w/w%) e (13,7/ 0/ 86,3 w/w%), respectivamente, e 7690, com 37 % de volume no pré-polímero e GLP (30/ 0 / 70 w/w%), apresentaram em geral melhores resultados, comparando com a espuma benchmark . Contudo, os seus shaking rate a -10/-10ºC, de cada espuma, apresentaram valores bastante inferiores à composição benchmarking.
Resumo:
The devastating impact of the Sumatra tsunami of 26 December 2004, raised the question for scientists of how to forecast a tsunami threat. In 2005, the IOC-UNESCO XXIII assembly decided to implement a global tsunami warning system to cover the regions that were not yet protected, namely the Indian Ocean, the Caribbean and the North East Atlantic, the Mediterranean and connected seas (the NEAM region). Within NEAM, the Gulf of Cadiz is the more sensitive area, with an important record of devastating historical events. The objective of this paper is to present a preliminary design for a reliable tsunami detection network for the Gulf of Cadiz, based on a network of sea-level observatories. The tsunamigenic potential of this region has been revised in order to define the active tectonic structures. Tsunami hydrodynamic modeling and GIS technology have been used to identify the appropriate locations for the minimum number of sea-level stations. Results show that 3 tsunameters are required as the minimum number of stations necessary to assure an acceptable protection to the large coastal population in the Gulf of Cadiz. In addition, 29 tide gauge stations could be necessary to fully assess the effects of a tsunami along the affected coasts of Portugal, Spain and Morocco.
Resumo:
Glucose 2-oxidase (pyranose oxidase, pyranose: oxygen-2-oxidoreductase, EC 1.1.3.10) from Coriolus versicolor catalyses the oxidation of D-glucose at carbon 2 in the presence of molecular O(2) producing D-glucosone (2-keto-glucose and D-arabino-2-hexosulose) and H(2)O(2). It was used to convert D-glucose into D-glucosone at moderate pressures (i.e. up to 150 bar) with compressed air in a modified commercial batch reactor. Several parameters affecting biocatalysis at moderate pressures were investigated as follows: pressure, [enzyme], [glucose], pH, temperature, nature of fluid and the presence of catalase. Glucose 2-oxidase was purified by immobilized metal affinity chromatography on epoxy-activated Sepharose 6B-IDA-Cu(II) column at pH 6.0. The rate of bioconversion of D-glucose increased with the pressure since an increase in the pressure with compressed air resulted in higher rates of conversion. On the other hand, the presence of catalase increased the rate of reaction which strongly suggests that H(2)O(2) acted as inhibitor for this reaction. The rate of bioconversion of D-glucose by glucose 2-oxidase in the presence of either nitrogen or supercritical CO(2) at 110 bar was very low compared with the use of compressed air at the same pressure. The optimum temperature (55 degrees C) and pH (5.0) of D-glucose bioconversion as well as kinetic parameters for this enzyme were determined under moderate pressure. The activation energy (E(a)) was 32.08 kJmol(-1) and kinetic parameters (V(max), K(m), K(cat) and K(cat)/K(m)) for this bioconversion were 8.8 Umg(-1) protein, 2.95 mM, 30.81 s(-1) and 10,444.06 s(-1)M(-1), respectively. The biomass of C. versicolor as well as the cell-free extract containing glucose 2-oxidase activity were also useful for bioconversion of D-glucose at moderate pressures. The enzyme was apparently stable at moderate pressures since such pressures did not affect significantly the enzyme activity.
Resumo:
Real structures can be thought as an assembly of components, as for instances plates, shells and beams. This later type of component is very commonly found in structures like frames which can involve a significant degree of complexity or as a reinforcement element of plates or shells. To obtain the desired mechanical behavior of these components or to improve their operating conditions when rehabilitating structures, one of the eventual parameters to consider for that purpose, when possible, is the location of the supports. In the present work, a beam-type structure is considered, and for a set of cases concerning different number and types of supports, as well as different load cases, the authors optimize the location of the supports in order to obtain minimum values of the maximum transverse deflection. The optimization processes are carried out using genetic algorithms. The results obtained, clearly show a good performance of the approach proposed. © 2014 IEEE.
Resumo:
Self-compacting concrete (SCC) can soon be expected to replace conventional concrete due to its many advantages. Its main characteristics in the fresh state are achieved essentially by a higher volume of mortar (more ultrafine material) and a decrease of the coarse-aggregates. The use of over-large volumes of additions such as fly ash (FA) and/or limestone filler (LF) can substantially affect the concrete's pore structure and consequently its durability. In this context, an experimental programme was conducted to evaluate the effect on the concrete's porosity and microstructure of incorporating FA and LF in binary and ternary mixes of SCC. For this, a total of 11 SIX mixes were produced; 1 with cement only (C); 3 with C + FA in 30%, 60% and 70% substitution (fad); 3 with C + LF in 30%, 60% and 70% fad; 4 with C + FA + LF in combinations of 10-20%, 20-10%, 20-40% and 40-20% f(ad), respectively. The results enabled conclusions to be established regarding the SCC's durability, based on its permeability and the microstructure of its pore structure. The properties studied are strongly affected by the type and quantity of additions. The use of ternary mixes also proves to be extremely favourable, confirming the beneficial effect of the synergy between these additions. (C) 2015 Elsevier Ltd. All rights reserved.
Resumo:
Abstract Self-compacting concrete (SCC) can soon be expected to replace conventional concrete due to its many advantages. Its main characteristics in the fresh state are achieved essentially by a higher volume of mortar (more ultrafine material) and a decrease of the coarse-aggregates. The use of over-large volumes of additions such as fly ash (FA) and/or limestone filler (LF) can substantially affect the concrete's pore structure and consequently its durability. In this context, an experimental programme was conducted to evaluate the effect on the concrete's porosity and microstructure of incorporating FA and LF in binary and ternary mixes of SCC. For this, a total of 11 SCC mixes were produced: 1 with cement only (C); 3 with C + FA in 30%, 60% and 70% substitution (fad); 3 with C + LF in 30%, 60% and 70% fad; 4 with C + FA + LF in combinations of 10-20%, 20-10%, 20-40% and 40-20% fad, respectively. The results enabled conclusions to be established regarding the SCC's durability, based on its permeability and the microstructure of its pore structure. The properties studied are strongly affected by the type and quantity of additions. The use of ternary mixes also proves to be extremely favourable, confirming the beneficial effect of the synergy between these additions. © 2015 Elsevier Ltd. All rights reserved.