21 resultados para Medical technology
em Repositório Científico do Instituto Politécnico de Lisboa - Portugal
Resumo:
Medical imaging is a powerful diagnostic tool. Consequently, the number of medical images taken has increased vastly over the past few decades. The most common medical imaging techniques use X-radiation as the primary investigative tool. The main limitation of using X-radiation is associated with the risk of developing cancers. Alongside this, technology has advanced and more centres now use CT scanners; these can incur significant radiation burdens compared with traditional X-ray imaging systems. The net effect is that the population radiation burden is rising steadily. Risk arising from X-radiation for diagnostic medical purposes needs minimising and one way to achieve this is through reducing radiation dose whilst optimising image quality. All ages are affected by risk from X-radiation however the increasing population age highlights the elderly as a new group that may require consideration. Of greatest concern are paediatric patients: firstly they are more sensitive to radiation; secondly their younger age means that the potential detriment to this group is greater. Containment of radiation exposure falls to a number of professionals within medical fields, from those who request imaging to those who produce the image. These staff are supported in their radiation protection role by engineers, physicists and technicians. It is important to realise that radiation protection is currently a major European focus of interest and minimum competence levels in radiation protection for radiographers have been defined through the integrated activities of the EU consortium called MEDRAPET. The outcomes of this project have been used by the European Federation of Radiographer Societies to describe the European Qualifications Framework levels for radiographers in radiation protection. Though variations exist between European countries radiographers and nuclear medicine technologists are normally the professional groups who are responsible for exposing screening populations and patients to X-radiation. As part of their training they learn fundamental principles of radiation protection and theoretical and practical approaches to dose minimisation. However dose minimisation is complex – it is not simply about reducing X-radiation without taking into account major contextual factors. These factors relate to the real world of clinical imaging and include the need to measure clinical image quality and lesion visibility when applying X-radiation dose reduction strategies. This requires the use of validated psychological and physics techniques to measure clinical image quality and lesion perceptibility.
Resumo:
Formaldehyde (FA) had been considered to be carcinogenic by the International Agency for Research on Cancer (group1), on the basis of sufficient evidence both in humans and in experimental animals, making it a subject of major environmental concern, especially in the occupational context. Manifold in vitro studies clearly indicated that FA is genotoxic, inducing various genotoxic effects in proliferating cultured mammalian cells. Cytokinesis-blocked micronucleus (CBMN) assay is used extensively in molecular epidemiology, and the chromosomal alterations most reported and studied by the CBMN are: micronucleus (MN), nucleoplasmic bridges (NPB) and nuclear buds (NBUDs). The pathology anatomy laboratories are work places that manipulate routinely FA and pathology anatomy technologists and pathologists contact daily with this chemical compound particularly in the macroscopic exam and grossing procedures. The aim of this study was to identify genotoxicity biomarkers in the set workers groups, such as micronucleus (MN), nucleoplasmic bridges (NPB) and nuclear buds (NBUD) in peripheral blood lymphocytes.
Resumo:
Over the centuries there has been a growing trend of societies and it is possible to verify their economic growth. This growth has provided an increased pressure on natural resources, often over-reaching the boundaries of each country, which has called into question the level of environmental sustainability in different countries. Sustainability is understood as a complex concept involving ecological, social, economic dimensions and temporal urban processes. Therefore, Firmino (2009) suggests that the ecological footprint (EF) allows people to establish dependency relations between human activities and the natural resources required for such activities and for the absorption of waste generated. According to Bergh & Verbruggen (1999) the EF is an objective, impartial and one-dimensional indicator that enables people to assess the sustainability. The Superior Schools have a crucial role in building the vision of a sustainable future as a reality, because in transmitting values and environmental principles to his students, are providing that they, in exercising his professional activity, make decisions weighing the environmental values. This ensures improved quality of life. The present study aims to determine the level of environmental sustainability of the Academic Community of Lisbon College of Health Technology (ESTeSL), by calculating the EF, and describe whether a relation between Footprint and various socio-demographic characteristics of the subjects.
Resumo:
Introdução – A mamografia é o principal método de diagnóstico por imagem utilizado no rastreio e diagnóstico do cancro da mama, sendo a modalidade de imagem recomendada em vários países da Europa e Estados Unidos para utilização em programas de rastreio. A implementação da tecnologia digital causou alterações na prática da mamografia, nomeadamente a necessidade de adaptar os programas de controlo de qualidade. Objetivos – Caracterizar a tecnologia instalada para mamografia em Portugal e as práticas adotadas na sua utilização pelos profissionais de saúde envolvidos. Concluir sobre o nível de harmonização das práticas em mamografia em Portugal e a conformidade com as recomendações internacionais. Identificar oportunidades para otimização que permitam assegurar a utilização eficaz e segura da tecnologia. Metodologia – Pesquisa e recolha de dados sobre a tecnologia instalada, fornecidos por fontes governamentais, prestadores de serviços de mamografia e indústria. Construção de três questionários, orientados ao perfil do médico radiologista, técnico de radiologia com atividade em mamografia digital e técnico de radiologia coordenador. Os questionários foram aplicados em 65 prestadores de serviços de mamografia selecionados com base em critérios de localização geográfica, tipo de tecnologia instalada e perfil da instituição. Resultados – Foram identificados 441 sistemas para mamografia em Portugal. A tecnologia mais frequente (62%) e vulgarmente conhecida por radiografia computorizada (computed radiography) é constituída por um detector (image plate) de material fotoestimulável inserido numa cassete de suporte e por um sistema de processamento ótico. A maioria destes sistemas (78%) está instalada em prestadores privados. Aproximadamente 12% dos equipamentos instalados são sistemas para radiografia digital direta (Direct Digital Radiography – DDR). Os critérios para seleção dos parâmetros técnicos de exposição variam, observando-se que em 65% das instituições são adotadas as recomendações dos fabricantes do equipamento. As ferramentas de pós-processamento mais usadas pelos médicos radiologistas são o ajuste do contraste e brilho e magnificação total e/ou localizada da imagem. Quinze instituições (em 19) têm implementado um programa de controlo de qualidade. Conclusões – Portugal apresenta um parque de equipamentos heterogéneo que inclui tecnologia obsoleta e tecnologia “topo de gama”. As recomendações/guidelines (europeias ou americanas) não são adotadas formalmente na maioria das instituições como guia para fundamentação das práticas em mamografia, dominando as recomendações dos fabricantes do equipamento. Foram identificadas, pelos técnicos de radiologia e médicos radiologistas, carências de formação especializada, nomeadamente nas temáticas da intervenção mamária, otimização da dose e controlo da qualidade. A maioria dos inquiridos concorda com a necessidade de certificação da prática da mamografia em Portugal e participaria num programa voluntário. ABSTRACT - Introduction – Mammography is the gold standard for screening and imaging diagnosis of breast disease. It is the imaging modality recommended by screening programs in various countries in Europe and the United States. The implementation of the digital technology promoted changes in mammography practice and triggered the need to adjust quality control programs. Aims –Characterize the technology for mammography installed in Portugal. Assess practice in use in mammography and its harmonization and compliance to international guidelines. Identify optimization needs to promote an effective and efficient use of digital mammography to full potential. Methodology – Literature review was performed. Data was collected from official sources (governmental bodies, mammography healthcare providers and medical imaging industry) regarding the number and specifications of mammography equipment installed in Portugal. Three questionnaires targeted at radiologists, breast radiographers and the chief-radiographer were designed for data collection on the technical and clinical practices in mammography. The questionnaires were delivered in a sample of 65 mammography providers selected according to geographical criteria, type of technology and institution profile. Results – Results revealed 441 mammography systems installed in Portugal. The most frequent (62%) technology type are computerized systems (CR) mostly installed in the private sector (78%). 12% are direct radiography systems (DDR). The criteria for selection of the exposure parameters differ between the institutions with the majority (65%) following the recommendations from the manufacturers. The use of available tools for post-processing is limited being the most frequently reported tools used the contrast/ brightness and Zoom or Pan Magnification tools. Fifteen participant institutions (out of 19) have implemented a quality control programme. Conclusions – The technology for mammography in Portugal is heterogeneous and includes both obsolete and state of the art equipment. International guidelines (European or American) are not formally implemented and the manufacturer recommendations are the most frequently used guidance. Education and training needs were identified amongst the healthcare professionals (radiologists and radiographers) with focus in the areas of mammography intervention, patient dose optimization and quality control. The majority of the participants agree with the certification of mammography in Portugal.
Resumo:
Advances in digital technology led to the development of digital x-ray detectors that are currently in wide use for projection radiography, including Computed Radiography (CR) and Digital Radiography (DR). Digital Imaging Systems for Plain Radiography addresses the current technological methods available to medical imaging professionals to ensure the optimization of the radiological process concerning image quality and reduction of patient exposure. Based on extensive research by the authors and reference to the current literature, the book addresses how exposure parameters influence the diagnostic quality in digital systems, what the current acceptable radiation doses are for useful diagnostic images, and at what level the dose could be reduced to maintain an accurate diagnosis. The book is a valuable resource for both students learning the field and for imaging professionals to apply to their own practice while performing radiological examinations with digital systems.
Resumo:
The increasing use of ionizing radiation for medical purposes emphasizes the concern about safety and justification of using ionizing radiation. This is linked with the use of new and high-dose X-ray technology (particularly CT). According to the UNSCEAR 2010 Report the total number of diagnostic medical examinations (both medical and dental) is estimated to have risen from 2.4 billion (period 1991–1996) to 3.6 billion (period 1997– 2008) - a marked increase in collective doses. An appropriate use of technology aiming diagnostic or therapy and respecting the ALARA principle is a mandatory requisite to safely perform any radiological procedure. Radiation protection is thus, a concern of all specialists in the radiology field ( radiologists, radiographers, medical physicists, among other professional groups). The importance of education and training of these professionals in reducing patients’ doses while maintaining the desired level of quality in medical exposures, as well as precise therapeutic treatments is well recognized. Education, training and continuing professional development (CPD) constitute a triad pointing towards the radiographers’ development of competences in the radiation protection field. This presentation excludes the radiographer role and competences in the fields of ultrasonography and MRI.
Resumo:
Glucose sensing is an issue with great interest in medical and biological applications. One possible approach to glucose detection takes advantage of measuring changes in fluorescence resonance energy transfer (FRET) between a fluorescent donor and an acceptor within a protein which undergoes glucose-induced changes in conformation. This demands the detection of fluorescent signals in the visible spectrum. In this paper we analyzed the emission spectrum obtained from fluorescent labels attached to a protein which changes its conformation in the presence of glucose using a commercial spectrofluorometer. Different glucose nanosensors were used to measure the output spectra with fluorescent signals located at the cyan and yellow bands of the spectrum. A new device is presented based on multilayered a-SiC:H heterostructures to detect identical transient visible signals. The transducer consists of a p-i'(a-SiC:H)-n/p-i(a-Si:H)-n heterostructure optimized for the detection of the fluorescence resonance energy transfer between fluorophores with excitation in the violet (400 nm) and emissions in the cyan (470 nm) and yellow (588 nm) range of the spectrum. Results show that the device photocurrent signal measured under reverse bias and using appropriate steady state optical bias, allows the separate detection of the cyan and yellow fluorescence signals presented.
Resumo:
Higher education institutions, has an active role in the development of a sustainable future and for this reason, it is essential that they became environmentally sustainable institutions, applying methods such as the Ecological Footprint analysis. This study intent is to strengthen the potential of the ecological footprint as an indicator of the sustainability of students of Lisbon School of Health Technology, and identify the relationship between the ecological footprint and the different socio-demographic variables.
Resumo:
According to the Intergovernmental Panel on Climate Change, the average temperature of the Earth's surface has risen about 1º C in the last 100 years and will increase, depending on the scenario emissions of Greenhouse Gases. The rising temperatures could trigger environmental effects like rising sea levels, floods, droughts, heat waves, hurricanes. With growing concerns about different environmental issues and the need to address climate change, institutions of higher education should create knowledge and integrate sustainability into teaching programs and research programs, as well as promoting environmental issues for society. The aim of this study is to determine the carbon footprint of the academic community of Lisbon School of Health Technology (ESTeSL) in 2013, identifying possible links between the Carbon Footprint and the different socio-demographic variables.
Resumo:
Mestrado em Medicina Nuclear - Ramo de especialização: Tomografia por Emissão de Positrões
Resumo:
In this paper we demonstrate an add/drop filter based on SiC technology. Tailoring of the channel bandwidth and wavelength is experimentally demonstrated. The concept is extended to implement a 1 by 4 wavelength division multiplexer with channel separation in the visible range. The device consists of a p-i'(a-SiC:H)-n/p-i(a-Si: H)-n heterostructure. Several monochromatic pulsed lights, separately or in a polychromatic mixture illuminated the device. Independent tuning of each channel is performed by steady state violet bias superimposed either from the front and back sides. Results show that, front background enhances the light-to-dark sensitivity of the long and medium wavelength channels and quench strongly the others. Back violet background has the opposite behaviour. This nonlinearity provides the possibility for selective removal or addition of wavelengths. An optoelectronic model is presented and explains the light filtering properties of the add/drop filter, under different optical bias conditions.
Resumo:
This paper discusses the technology of smart floors as a enabler of smart cities. The discussion will be based on technology that is embedded into the environment that enable location, navigation but also wireless power transmission for powering up elements siting on it, typically mobile devices. One of those examples is the smart floor, this implementation follows two paths, one where the floor is passive, and normally passive RFID's are embedded into the floor, they are used to provide intelligence into the surrounding space, this is normally complemented with a battery powered mobile unit that scans the floor for the sensors and communicates the information to a database which locates the mobile device in the environment. The other path for the smart city enabler is where the floor is active and delivers energy for the objects standing on top of it. In this paper these two approaches will be presented, by discussing the technology behind it. © 2014 IEEE.
Resumo:
This paper presents a layered Smart Grid architecture enhancing security and reliability, having the ability to act in order to maintain and correct infrastructure components without affecting the client service. The architecture presented is based in the core of well design software engineering, standing upon standards developed over the years. The layered Smart Grid offers a base tool to ease new standards and energy policies implementation. The ZigBee technology implementation test methodology for the Smart Grid is presented, and provides field tests using ZigBee technology to control the new Smart Grid architecture approach. (C) 2014 Elsevier Ltd. All rights reserved.
Resumo:
Aims of study: 1) Describe the importance of human visual system on lesion detection in medical imaging perception research; 2) Discuss the relevance of research in medical imaging addressing visual function analysis; 3) Identify visual function tests which could be conducted on observers prior to participation in medical imaging perception research.
Resumo:
Objetivos do estudo: definir o conceito de Avaliação de Tecnologias em Saúde (ATS); identificar métodos de pesquisa para ATS no âmbito da imagem médica; entender o valor de revisões sistemáticas e metaanálise em ATS; compreender a influência da ATS na imagem médica.