18 resultados para Magnetic resonance images

em Repositório Científico do Instituto Politécnico de Lisboa - Portugal


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The amount of fat is a component that complicates the clinical evaluation and the differential diagnostic between benign and malign lesions in the breast MRI examinations. To overcome this problem, an effective erasing of the fat signal over the images acquisition process, is essentials. This study aims to compare three fat suppression techniques (STIR, SPIR, SPAIR) in the MR images of the breast and to evaluate the best image quality regarding its clinical usefulness. To mimic breast women, a breast phantom was constructed. First the exterior contour and, in second time, its content which was selected based on 7 samples with different components. Finally it was undergone to a MRI breast protocol with the three different fat saturation techniques. The examinations were performed on a 1.5 T MRI system (Philips®). A group of 5 experts evaluated 9 sequences, 3 of each with fat suppression techniques, in which the frequency offset and TI (Inversion Time) were the variables changed. This qualitative image analysis was performed according 4 parameters (saturation uniformity, saturation efficacy, detail of the anatomical structures and differentiation between the fibroglandular and adipose tissue), using a five-point Likert scale. The statistics analysis showed that anyone of the fat suppression techniques demonstrated significant differences compared to the others with (p > 0.05) and regarding each parameter independently. By Fleiss’ kappa coefficient there was a good agreement among observers P(e) = 0.68. When comparing STIR, SPIR and SPAIR techniques it was confirmed that all of them have advantages in the study of the breast MRI. For the studied parameters, the results through the Friedman Test showed that there are similar advantages applying anyone of these techniques.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Claustrophobia causes a huge discomfort to those who need to perform Magnetic Resonance examinations mainly due to the physical design of most equipment. This study aimed to maximize the success rate of Magnetic Resonance Imaging (MRI) clinical studies in claustrophobic patients by the identification of facilitative strategies.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Mestrado em Radiações Aplicadas às Tecnologias da Saúde

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The Fast Field-Cycling Nuclear Magnetic Resonance (FFC-NMR) is a technique used to study the molecular dynamics of different types of materials. The main elements of this equipment are a magnet and its power supply. The magnet used as reference in this work is basically a ferromagnetic core with two sets of coils and an air-gap where the materials' sample is placed. The power supply should supply the magnet being the magnet current controlled in order to perform cycles. One of the technical issues of this type of solution is the compensation of the non-linearities associated to the magnetic characteristic of the magnet and to parasitic magnetic fields. To overcome this problem, this paper describes and discusses a solution for the FFC-NMR power supply based on a four quadrant DC/DC converter.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Susceptibility Weighted Image (SWI) is a Magnetic Resonance Imaging (MRI) technique that combines high spatial resolution and sensitivity to provide magnetic susceptibility differences between tissues. It is extremely sensitive to venous blood due to its iron content of deoxyhemoglobin. The aim of this study was to evaluate, through the SWI technique, the differences in cerebral venous vasculature according to the variation of blood pressure values. 20 subjects divided in two groups (10 hypertensive and 10 normotensive patients) underwent a MRI system with a Siemens® scanner model Avanto of 1.5T using a synergy head coil (4 channels). The obtained sequences were T1w, T2w-FLAIR, T2* and SWI. The value of Contrast-to-Noise Ratio (CNR) was assessed in MinIP (Minimum Intensity Projection) and Magnitude images, through drawing free hand ROIs in venous structures: Superior Sagittal Sinus (SSS) Internal Cerebral Vein (ICV) and Sinus Confluence (SC). The obtained values were presented in descriptive statistics-quartiles and extremes diagrams. The results were compared between groups. CNR shown higher values for normotensive group in MinIP (108.89 ± 6.907) to ICV; (238.73 ± 18.556) to SC and (239.384 ± 52.303) to SSS. These values are bigger than images from Hypertensive group about 46 a.u. in average. Comparing the results of Magnitude and MinIP images, there were obtained lower CNR values for the hypertensive group. There were differences in the CNR values between both groups, being these values more expressive in the large vessels-SSS and SC. The SWI is a potential technique to evaluate and characterize the blood pressure variation in the studied vessels adding a physiological perspective to MRI and giving a new approach to the radiological vascular studies.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

O presente estudo avalia o efeito da cafeína no valor da razão contraste ruído (CNR) em imagens SWI. A população do estudo incluiu 24 voluntários saudáveis que estiveram pelo menos 24h privados da ingestão de cafeína. Adquiriram-se imagens SWI antes e após a ingestão de 100ml de café. Os voluntários foram divididos em 4 grupos de 6 indivíduos e avaliados sequencialmente (15, 25, 30 e 45 min pós-cafeína). ABSTRACT - The present study investigates the effect of caffeine on contrast-to-noise ratio (CNR) in SWI images. Twenty-four volunteers were enrolled in the study. All the volunteers were caffeine-free for 24h prior to the test. SWI images were acquired before caffeine ingestion and post-ingestion of 100ml of coffee. The volunteers were divided into four groups of subjects and evaluated sequentially (15, 25, 30 and 45 min after caffeine).

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Mestrado em Radiações Aplicadas às Tecnologias da Saúde. Área de especialização: Ressonância Magnética

Relevância:

90.00% 90.00%

Publicador:

Resumo:

RESUMO: Objetivos – Determinar a sensibilidade e especificidade das ponderações Difusão (DWI) e T2 Fluid-Attenuated Inversion Recovery (FLAIR) na avaliação de lesões da substância branca (SB) e verificar em que medida se complementam, por forma a criar um conjunto de boas práticas na RM cranioencefálica de rotina. Metodologia – Recorrendo-se a uma metodologia quantitativa, efetuou-se uma análise retrospetiva da qual foram selecionados 30 pacientes, 10 sem patologia e 20 com patologia (2 com EM, 7 com Leucoencefalopatia, 6 com doença microangiopática e 5 com patologia da substância branca indefinida). Obteve-se uma amostra de 60 imagens, nomeadamente: 30 imagens ponderadas em DWI e 30 em T2 FLAIR. Recorrendo ao programa Viewdex®, três observadores avaliaram um conjunto de imagens segundo sete critérios: visibilidade, deteção, homogeneidade, localização, margens e dimensões da lesão e capacidade de diagnóstico. Com os resultados obtidos recorreu-se ao cálculo de sensibilidade e especificidade pelas Curvas ROC, bem como à análise estatística, nomeadamente, Teste-T, Índice de Concordância Kappa e coeficiente de correlação de Pearson entre as variáveis em estudo. Resultados – Os resultados de sensibilidade e de especificidade obtidos para a ponderação T2 FLAIR foram superiores (0,915 e 0,038, respetivamente) aos da ponderação DWI (0,08 e 0,100, respetivamente). Não se verificaram variâncias populacionais significativas. Obteve-se uma elevada correlação linear entre as variáveis com um valor r situado entre 0,8 e 0,99. Verificou-se também uma variabilidade considerável entre os observadores. Conclusões – Dados os baixos valores de sensibilidade e especificidade obtidos para a DWI, sugere-se que esta deva ser incluída no protocolo de rotina de crânio como auxiliar no diagnóstico diferencial com outras patologias.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

This paper is a contribution for the assessment and comparison of magnet properties based on magnetic field characteristics particularly concerning the magnetic induction uniformity in the air gaps. For this aim, a solver was developed and implemented to determine the magnetic field of a magnetic core to be used in Fast Field Cycling (FFC) Nuclear Magnetic Resonance (NMR) relaxometry. The electromagnetic field computation is based on a 2D finite-element method (FEM) using both the scalar and the vector potential formulation. Results for the magnetic field lines and the magnetic induction vector in the air gap are presented. The target magnetic induction is 0.2 T, which is a typical requirement of the FFC NMR technique, which can be achieved with a magnetic core based on permanent magnets or coils. In addition, this application requires high magnetic induction uniformity. To achieve this goal, a solution including superconducting pieces is analyzed. Results are compared with a different FEM program.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

In this work, we present a neural network (NN) based method designed for 3D rigid-body registration of FMRI time series, which relies on a limited number of Fourier coefficients of the images to be aligned. These coefficients, which are comprised in a small cubic neighborhood located at the first octant of a 3D Fourier space (including the DC component), are then fed into six NN during the learning stage. Each NN yields the estimates of a registration parameter. The proposed method was assessed for 3D rigid-body transformations, using DC neighborhoods of different sizes. The mean absolute registration errors are of approximately 0.030 mm in translations and 0.030 deg in rotations, for the typical motion amplitudes encountered in FMRI studies. The construction of the training set and the learning stage are fast requiring, respectively, 90 s and 1 to 12 s, depending on the number of input and hidden units of the NN. We believe that NN-based approaches to the problem of FMRI registration can be of great interest in the future. For instance, NN relying on limited K-space data (possibly in navigation echoes) can be a valid solution to the problem of prospective (in frame) FMRI registration.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Introdução – A ressonância magnética (RM) mamária com injeção de contraste é uma ferramenta indispensável para a caracterização de lesões mamárias. Para tal, é fulcral uma boa capacidade de saturação de gordura de forma a delimitar as lesões observadas. Este trabalho tem como objetivo analisar quantitativa e qualitativamente as técnicas de saturação de gordura em RM mamária, nomeadamente as técnicas SPAIR e Dixon. Metodologia – Utilizou-se um equipamento de RM de 1,5T com bobina específica para a mama. Aplicou-se, durante o exame, uma sequência adicional em que a técnica de saturação de gordura utilizada foi a Dixon. Posteriormente foram analisadas as imagens obtidas com as técnicas SPAIR e Dixon e colocadas regiões de interesse (ROI) na lesão, na glândula mamária, no tecido adiposo e no ar. Estes valores de sinal obtidos foram registados e calcularam-se as relações sinal-ruído (SNR), contraste-ruído (CNR) e uniformidade de saturação de gordura para as mesmas estruturas a analisar e nas distintas sequências. Resultados – Verificou-se que a técnica de supressão de gordura Dixon apresenta resultados quantitativos e qualitativos superiores à técnica SPAIR. Conclusões – Recomenda-se a utilização da técnica Dixon para saturação de gordura nas sequências de estudo dinâmico com agente de contraste, especificamente nos estudos de RM mamária.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Perceber a rede estrutural formada pelos neurónios no cérebro a nível da macro escala é um desafio atual na área das neurociências. Neste estudo analisou-se a conectividade estrutural do cérebro em 22 indivíduos saudáveis e em dois doentes com epilepsia pós-traumática. Avaliaram-se as diferenças entre estes dois grupos. Também se pesquisaram diferenças a nível do género e idade no grupo de indivíduos saudáveis e os que têm valores médios mais elevados nas métricas de caracterização da rede. Para tal, desenvolveu-se um protocolo de análise recorrendo a diversos softwares especializados e usaram-se métricas da Teoria dos Grafos para a caracterização da conectividade estrutural entre 118 regiões encefálicas distintas. Dentro do grupo dos indivíduos saudáveis concluiu-se que os homens, no geral, são os que têm média mais alta para as métricas de caracterização da rede estrutural. Contudo, não se observaram diferenças significativas em relação ao género nas métricas de caracterização global do cérebro. Relativamente à idade, esta correlaciona-se negativamente, no geral, com as métricas de caracterização da rede estrutural. As regiões onde se observaram as diferenças mais importantes entre indivíduos saudáveis e doentes são: o sulco rolândico, o hipocampo, o pré-cuneus, o tálamo e o cerebelo bilateralmente. Estas diferenças são consistentes com as imagens radiológicas dos doentes e com a literatura estudada sobre a epilepsia pós-traumática. Preveem-se desenvolvimentos para o estudo da conectividade estrutural do cérebro humano, uma vez que a sua potencialidade pode ser combinada com outros métodos de modo a caracterizar as alterações dos circuitos cerebrais.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Introdução – O presente estudo avaliou o efeito da cafeína no valor da razão contraste ruído (CNR) em imagens SWI. Objetivos – Avaliar o efeito da cafeína qualitativamente e quantificado pelo cálculo do valor CNR em imagens de magnitude e MIP para as estruturas: veia cerebral interna, seio sagital superior, tórcula e artéria cerebral média. Metodologia – A população do estudo incluiu 24 voluntários saudáveis que estiveram pelo menos 24h privados da ingestão de cafeína. Adquiriram-se imagens SWI antes e após a ingestão de 100ml de café. Os voluntários foram subdivididos em quatro grupos de seis indivíduos/grupo e avaliados separadamente após decorrido um intervalo de tempo diferente para cada grupo (15, 25, 30 ou 45min pós-cafeína). Utilizou-se um scanner Siemens Avanto 1,5 T com bobine standard de crânio e os parâmetros: T2* GRE 3D de alta resolução no plano axial, TR=49; TE=40; FA=15; FOV=187x230; matriz=221x320. O processamento de imagem foi efetuado no software OsiriX® e a análise estatística no GraphPadPrism®. Resultados e Discussão – As alterações de sinal e diferenças de contraste predominaram nas estruturas venosas e não foram significantes na substância branca, LCR e artéria cerebral média. Os valores CNR pré-cafeína diferiram significativamente do pós-cafeína nas imagens de magnitude e MIP na veia cerebral interna e nas imagens de magnitude do seio sagital superior e da tórcula (p<0,0001). Não se verificaram diferenças significativas entre os grupos avaliados nos diferentes tempos pós-cafeína. Conclusões – Especulamos que a cafeína possa vir a ser usada como agente de contraste nas imagens SWI barato, eficaz e de fácil administração.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Objetivos – Um dos principais objetivos da neurociência tem sido, desde sempre, compreender as funcionalidades do cérebro. A introdução da ressonância magnética funcional contribuiu em grande escala para o desenvolvimento do estudo cerebral. Assim, esta investigação tem como principal objetivo identificar e desenhar os diferentes perfis de localizações cerebrais, a nível do córtex motor, numa população jovem saudável, permitindo, assim, um maior conhecimento nesta área e dando um contributo à área da neurologia. Material e métodos – Foi realizado um estudo de ressonância magnética funcional em 30 indivíduos saudáveis numa clínica de imagiologia médica. Para tal recorreu-se a equipamento adequado para a recolha de dados. O paradigma motor utilizado foi o movimento dos dedos das mãos. Através das imagens obtidas foi medida a área de cada região ativa. Com o suporte do programa SPSS (versão 19) todos os valores foram tratados estatisticamente. Conclusão – Após todo este processo concluiu-se que a área do cérebro maioritariamente ativa, no momento do paradigma motor, encontra-se no hemisfério esquerdo.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Mestrado em Radiações aplicadas às Tecnologias da Saúde - Ramo de Ressonância Magnética