6 resultados para MEDICAL PATIENTS
em Repositório Científico do Instituto Politécnico de Lisboa - Portugal
Resumo:
Captopril, an inhibitor of angiotensin converting enzyme (ACE), is used to treat medical conditions like hypertension and heart failure, and it is usually administered in tablet form for adults. Since this dosage form is not recommended for infants and children up to 6 years, hospital pharmacies have to prepare liquid formulations for oral administration of captopril. Traditionally, concentration of captopril used in the formulations is 1mg/ml. The problem is that captopril is prone to oxidation, and its stability in solution is affected by pH, concentration of captopril, the presence of oxygen or metal ions. The influence of different formulation ingredients on the properties of physical and chemical stability of captopril in liquid preparations has been evaluated. Main of the study: to evaluate the stability of captopril for 30 days when formulated in a 1 mg/ml suspension adjuvanted with citric acid.
Resumo:
Background: Protein-energy wasting (PEW), associated with inflammation and overhydration, is common in haemodialysis (HD) patients and is associated with high morbidity and mortality. Objective: Assess the relationship between nutritional status, markers of inflammation and body composition through bioimpedance spectroscopy (BIS) in HD patients. Methods: This observational, cross-sectional, single centre study, carried out in an HD centre in Forte da Casa (Portugal), involved 75 patients on an HD programme. In all participating patients, the following laboratory tests were conducted: haemoglobin, albumin, C-reactive protein (CRP) and 25-hydroxyvitamin D3 [25(OH)D3]. The body mass index of all patients was calculated and a modified version of subjective global assessment (SGA) was produced for patients on dialysis. Intracellular water (ICW) and extracellular water (ECW) were measured by BIS (Body Composition Monitor®, Fresenius Medical Care®) after the HD session. In statistical analysis, Spearman’s correlation was used for the univariate analysis and linear regression for the multivariate analysis (SPSS 14.0). A P value of <.05 was considered statistically significant. Results: PEW, inversely assessed through the ICW/body weight (BW) ratio, was positively related to age (P<.001), presence of diabetes (P=.004), BMI (P=.01) and CRP (P=.008) and negatively related to albumin (p=.006) and 25(OH)D3 (P=.007). Overhydration, assessed directly through the ECW/BW ratio, was positively related with CRP (P=.009) and SGA (P=.03), and negatively with 25(OH)D3 (P=.006) and BMI (P=.01). In multivariate analysis, PEW was associated with older age (P<.001), the presence of diabetes (P=.003), lower 25(OH)D3 (P=.008), higher CRP (P=.001) and lower albumin levels (P=.004). Over-hydration was associated with higher CRP (P=.001) and lower levels of 25(OH)D3 (P=.003). Conclusions: Taking these results into account, the ICW/BW and ECW/BW ratios, assessed with BIS, have proven to be good markers of the nutritional and inflammatory status of HD patients. BIS may be a useful tool for regularly assessing the nutritional and hydration status in these patients and may allow nutritional advice to be improved and adjusted.
Resumo:
Background - Chronic illnesses are diseases of long duration and generally of slow progression. They cause significant quality of life impairment. The aim of this study was to analyse psychosocial predictors of quality of life and of subjective well-being in chronic Portuguese patients. Methods - Chronic disease patients (n = 774) were recruited from central Portuguese Hospitals. Participants completed self-reported questionnaires assessing socio-demographic, clinical, psychosocial and outcome variables: quality of life (HRQL) and subjective well-being (SWB). MANCOVA analyses were used to test psychosocial factors as determinants of HRQL and SWB. Results - After controlling for socio-demographic and clinical variables, results showed that dispositional optimism, positive affect, spirituality, social support and treatment adherence are significant predictors of HRQL and SWB. Similar predictors of quality of life, such as positive affect, treatment adherence and spirituality, were found for subgroups of disease classified by medical condition. Conclusions - The work identifies psychosocial factors associated with quality of life. The predictors for the entire group of different chronic diseases are similar to the ones found in different chronic disease subgroups: positive affect, social support, treatment adherence and spirituality. Patients with more positive affect, additional social support, an adequate treatment adherence and a feel-good spirituality, felt better with the disease conditions and consequently had a better quality of life. This study contributes to understanding and improving the processes associated with quality of life, which is relevant for health care providers and chronic diseases support.
Resumo:
Medical imaging is a powerful diagnostic tool. Consequently, the number of medical images taken has increased vastly over the past few decades. The most common medical imaging techniques use X-radiation as the primary investigative tool. The main limitation of using X-radiation is associated with the risk of developing cancers. Alongside this, technology has advanced and more centres now use CT scanners; these can incur significant radiation burdens compared with traditional X-ray imaging systems. The net effect is that the population radiation burden is rising steadily. Risk arising from X-radiation for diagnostic medical purposes needs minimising and one way to achieve this is through reducing radiation dose whilst optimising image quality. All ages are affected by risk from X-radiation however the increasing population age highlights the elderly as a new group that may require consideration. Of greatest concern are paediatric patients: firstly they are more sensitive to radiation; secondly their younger age means that the potential detriment to this group is greater. Containment of radiation exposure falls to a number of professionals within medical fields, from those who request imaging to those who produce the image. These staff are supported in their radiation protection role by engineers, physicists and technicians. It is important to realise that radiation protection is currently a major European focus of interest and minimum competence levels in radiation protection for radiographers have been defined through the integrated activities of the EU consortium called MEDRAPET. The outcomes of this project have been used by the European Federation of Radiographer Societies to describe the European Qualifications Framework levels for radiographers in radiation protection. Though variations exist between European countries radiographers and nuclear medicine technologists are normally the professional groups who are responsible for exposing screening populations and patients to X-radiation. As part of their training they learn fundamental principles of radiation protection and theoretical and practical approaches to dose minimisation. However dose minimisation is complex – it is not simply about reducing X-radiation without taking into account major contextual factors. These factors relate to the real world of clinical imaging and include the need to measure clinical image quality and lesion visibility when applying X-radiation dose reduction strategies. This requires the use of validated psychological and physics techniques to measure clinical image quality and lesion perceptibility.
Resumo:
Introduction: The purpose of this review is to gather and analyse current research publications to evaluate Sinogram-Affirmed Iterative Reconstruction (SAFIRE). The aim of this review is to investigate whether this algorithm is capable of reducing the dose delivered during CT imaging while maintaining image quality. Recent research shows that children have a greater risk per unit dose due to increased radiosensitivity and longer life expectancies, which means it is particularly important to reduce the radiation dose received by children. Discussion: Recent publications suggest that SAFIRE is capable of reducing image noise in CT images, thereby enabling the potential to reduce dose. Some publications suggest a decrease in dose, by up to 64% compared to filtered back projection, can be accomplished without a change in image quality. However, literature suggests that using a higher SAFIRE strength may alter the image texture, creating an overly ‘smoothed’ image that lacks contrast. Some literature reports SAFIRE gives decreased low contrast detectability as well as spatial resolution. Publications tend to agree that SAFIRE strength three is optimal for an acceptable level of visual image quality, but more research is required. The importance of creating a balance between dose reduction and image quality is stressed. In this literature review most of the publications were completed using adults or phantoms, and a distinct lack of literature for paediatric patients is noted. Conclusion: It is necessary to find an optimal way to balance dose reduction and image quality. More research relating to SAFIRE and paediatric patients is required to fully investigate dose reduction potential in this population, for a range of different SAFIRE strengths.
Resumo:
Patients scheduled for a magnetic resonance imaging (MRI) scan sometimes require screening for ferromagnetic Intra Orbital Foreign Bodies (IOFBs). To assess this, they are required to fill out a screening protocol questionnaire before their scan. If it is established that a patient is at high risk, radiographic imaging is necessary. This review examines literature to evaluate which imaging modality should be used to screen for IOFBs, considering that the eye is highly sensitive to ionising radiation and any dose should be minimised. Method: Several websites and books were searched for information, these were as follows: PubMed, Science Direct, Web of Knowledge and Google Scholar. The terms searched related to IOFB, Ionising radiation, Magnetic Resonance Imaging Safety, Image Quality, Effective Dose, Orbits and X-ray. Thirty five articles were found, several were rejected due to age or irrelevance; twenty eight were eventually accepted. Results: There are several imaging techniques that can be used. Some articles investigated the use of ultrasound for investigation of ferromagnetic IOFBs of the eye and others discussed using Computed Tomography (CT) and X-ray. Some gaps in the literature were identified, mainly that there are no articles which discuss the lowest effective dose while having adequate image quality for orbital imaging. Conclusion: X-ray is the best method to identify IOFBs. The only problem is that there is no research which highlights exposure factors that maintain sufficient image quality for viewing IOFBs and keep the effective dose to the eye As Low As Reasonably Achievable (ALARA).