28 resultados para Lung volume measurement

em Repositório Científico do Instituto Politécnico de Lisboa - Portugal


Relevância:

50.00% 50.00%

Publicador:

Resumo:

Introduction: Standard Uptake Value (SUV) is a measurement of the uptake in a tumour normalized on the basis of a distribution volume and is used to quantify 18F-Fluorodeoxiglucose (FDG) uptake in tumors, such as primary lung tumor. Several sources of error can affect its accuracy. Normalization can be based on body weight, body surface area (BSA) and lean body mass (LBM). The aim of this study is to compare the influence of 3 normalization volumes in the calculation of SUV: body weight (SUVW), BSA (SUVBSA) and LBM (SUVLBM), with and without glucose correction, in patients with known primary lung tumor. The correlation between SUV and weight, height, blood glucose level, injected activity and time between injection and image acquisition is evaluated. Methods: Sample included 30 subjects (8 female and 22 male) with primary lung tumor, with clinical indication for 18F-FDG Positron Emission Tomography (PET). Images were acquired on a Siemens Biography according to the department’s protocol. Maximum pixel SUVW was obtained for abnormal uptake focus through semiautomatic VOI with Quantification 3D isocontour (threshold 2.5). The concentration of radioactivity (kBq/ml) was obtained from SUVW, SUVBSA, SUVLBM and the glucose corrected SUV were mathematically obtained. Results: Statistically significant differences between SUVW, SUVBSA and SUVLBM and between SUVWgluc, SUVBSAgluc and SUVLBMgluc were observed (p=0.000<0.05). The blood glucose level showed significant positive correlations with SUVW (r=0.371; p=0.043) and SUVLBM (r=0.389; p=0.034). SUVBSA showed independence of variations with the blood glucose level. Conclusion: The measurement of a radiopharmaceutical tumor uptake normalized on the basis of different distribution volumes is still variable. Further investigation on this subject is recommended.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A crucial method for investigating patients with coronary artery disease (CAD) is the calculation of the left ventricular ejection fraction (LVEF). It is, consequently, imperative to precisely estimate the value of LVEF--a process that can be done with myocardial perfusion scintigraphy. Therefore, the present study aimed to establish and compare the estimation performance of the quantitative parameters of the reconstruction methods filtered backprojection (FBP) and ordered-subset expectation maximization (OSEM). Methods: A beating-heart phantom with known values of end-diastolic volume, end-systolic volume, and LVEF was used. Quantitative gated SPECT/quantitative perfusion SPECT software was used to obtain these quantitative parameters in a semiautomatic mode. The Butterworth filter was used in FBP, with the cutoff frequencies between 0.2 and 0.8 cycles per pixel combined with the orders of 5, 10, 15, and 20. Sixty-three reconstructions were performed using 2, 4, 6, 8, 10, 12, and 16 OSEM subsets, combined with several iterations: 2, 4, 6, 8, 10, 12, 16, 32, and 64. Results: With FBP, the values of end-diastolic, end-systolic, and the stroke volumes rise as the cutoff frequency increases, whereas the value of LVEF diminishes. This same pattern is verified with the OSEM reconstruction. However, with OSEM there is a more precise estimation of the quantitative parameters, especially with the combinations 2 iterations × 10 subsets and 2 iterations × 12 subsets. Conclusion: The OSEM reconstruction presents better estimations of the quantitative parameters than does FBP. This study recommends the use of 2 iterations with 10 or 12 subsets for OSEM and a cutoff frequency of 0.5 cycles per pixel with the orders 5, 10, or 15 for FBP as the best estimations for the left ventricular volumes and ejection fraction quantification in myocardial perfusion scintigraphy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O principal objectivo do estudo é determinar uma fórmula de cálculo para o volume de ultrafiltrado a retirar, pela Ultrafiltração Modificada (UFM), a doentes adultos submetidos a cirurgia cardíaca. A população-alvo é constituída por 489 casos relativos às cirurgias cardíacas realizadas entre Janeiro de 2003 e Dezembro de 2005, que cumprem os critérios de inclusão e exclusão definidos. Trata-se de um estudo retrospectivo, do tipo correlacional quantitativo com abordagem dedutiva, em que as variáveis estudadas foram obtidas através da consulta dos relatórios de perfusão cardiovascular do serviço de Cirurgia Cardiotorácica do Hospital de Santa Marta, EPE. A relação entre as variáveis em estudo foi analisada através da correlação e modelos de regressão linear. O modelo obtido para definir a fórmula de cálculo desejada tem por base a correlação existente entre o volume a retirar por UFM e a superfície corporal do doente, sendo este o único dos três modelos estudados que demonstra uma dependência, ainda que fraca, entre as variáveis, e exprimindo-se através da fórmula Y=545,4.X3, em que Y é o volume a retirar por UFM e X é o valor da superfície corporal de cada doente, e sendo representativo apenas para 4% da população em estudo.” O aumento médio de hemoglobina pós-UFM é de 1,9±1,09g/ dl, o que traduz eficácia da técnica na obtenção de hemoconcentração.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Este estudo analisa o modo como se desenvolve a aprendizagem do conceito de volume nos alunos do 6º ano de escolaridade, no quadro de uma proposta pedagógica que dá ênfase a actividades que apelam à visualização e ao raciocínio espacial. O seu objectivo principal foi o de compreender as ideias que os alunos do 6.º ano têm sobre volume e perceber como se desenvolvem quando são envolvidos numa experiência de ensino, tendo por base uma cadeia de tarefas que apelam à visualização e ao raciocínio espacial. O estudo seguiu uma metodologia de investigação qualitativa baseada em estudos de caso. A proposta pedagógica foi desenvolvida em quatro aulas; três de noventa minutos e uma de quarenta e cinco minutos, durante os 2º e 3º períodos do ano lectivo de 2009/2010. A recolha de dados envolveu a realização de gravações áudio, em ambiente de sala de aula, dos alunos que constituíram os estudos de caso, registo de observações do desempenho dos alunos e os documentos produzidos por estes. Os resultados mostram que, ao longo da proposta pedagógica, os alunos adquiriram estratégias de contagem que lhes permitiram criar estruturas, para compreender a organização dos paralelepípedos e desenvolver o conceito de volume. iii ABSTRACT This study examines how 6th graders’ students develop the concept of volume in a learning experience context which emphasizes the visualization and spatial reasoning. The main objective of this study is to understand the ideas of 6th grade students about volume and see how they develop them when they are involved in a learning experience, based on a sequence of tasks that call for visualization and spatial reasoning. The study followed a qualitative research methodology based on case studies. The learning experience was developed in four classes, three ninety minutes period and one forty-five minutes, during the 2nd and 3rd terms of the school year 2009/2010. Data collection involved the use of audio recordings in the classroom environment, recording observations of student performance and the documents produced by them. The results showed that, over the learning experience, students acquired counting strategies that allowed them to create structures for understanding the organization of cubes arrays and develop the concept of volume.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O presente trabalho incide sobre a análise da eficiência energética dos elevadores. Para se poder entender esta questão, são apresentadas diversas informações que permitem conhecer os factores associados aos consumos de energia activa, procurando-se perceber qual o rendimento destes equipamentos. Inicialmente são analisados os diversos componentes, que fazem parte de um elevador e os locais em que esses componentes são instalados. Abordam-se as diferentes soluções de accionamento, os diversos tipos de utilização e as diferentes tecnologias que podem ser aplicadas. O estudo dos consumos de energia eléctrica dos elevadores, foi efectuado com base na metodologia desenvolvida pelo grupo E4, do programa Utilização Eficiente da Energia, da Comunidade Europeia, cujo suporte foi o DRAFT ISSO/DIS 25745 - 1 Energy Performance of Lifts and Escalators - Part 1: Energy Measurement and Conformance. Os consumos de energia eléctrica serão caracterizados com os elevadores a serem monitorizados individualmente e sem carga na cabina. A apresentação de resultados obtidos terá em linha de conta: a energia eléctrica consumida com o equipamento em modo de funcionamento, ou seja, com este a realizar ciclos completos, e a potência eléctrica consumida com a instalação em modo de standby, ou seja em não operação. No presente trabalho, são divulgados estudos do grupo E4, em que foram monitorizados elevadores em quatro países da Europa: Portugal, Alemanha, Itália e Polónia. Estes estudos permitem estimar os consumos anuais de energia eléctrica, a nível de funcionamento e a nível de standby e estimar o consumo total, seguindo como base a metodologia anteriormente referida. Para se caracterizar o parque Europeu de elevadores, o grupo E4 recorreu à ELA, Associação Europeia de Elevadores, tendo assim sido possível estimar o consumo anual numa Europa a 27, acrescido do parque da Suíça e da Noruega. Pretende-se com isso poder estimar o potencial de redução no consumo energético no parque analisado, com a aplicação das Melhores Tecnologias Disponíveis (MTD) e com a aplicação de tecnologias que ainda estão em fase de desenvolvimento. (MTND). Paralelamente o autor irá apresentar as monitorizações que efectuou a três elevadores, para os quais procurou validar as leituras efectuadas, comparando os consumos obtidos, com os consumos registados pelas monitorizações do grupo E4 e respectivas estimativas de consumos anuais de energia. As monitorizações do autor, serão utilizadas na catalogação desses três equipamentos a nível de classes de eficiência energética, tendo por base a VDI 4707/Part 1 - Lifts - Energy Efficiency - VDI manual Building Services - Volume 5: Transportation Systems. Procura-se, também, criar um método de apoio na tomada de decisão nas diversas fases de um ciclo do elevador, nomeadamente: desde a especificação, a selecção do sistema de accionamento, a selecção dos sistemas auxiliares, a instalação e a operação do elevador, com vista à melhoria da eficiência energética, e á instalação futura ou à modernização dos equipamentos existentes. Abordam-se as barreiras existentes que inibem a mudança no sector de elevação, para a implementação das MTD no parque de elevadores existente ou no desenvolvimento de novas tecnologias que possibilitem a melhoria da eficiência energética, MTND. Por ultimo, aborda-se de forma simples a temática da supervisão técnica nos elevadores, através da monitorização e supervisão dos diversos componentes, com vista à optimização da gestão da manutenção e procurando interligar esta gestão à melhoria da eficiência energética. Consegue-se concluir que apenas com a aplicação das MTD, podem ser obtidos ganhos de eficiência energética, e também que este tema não tem tido a importância que merece, pois, na análise da eficiência energética de um edifício, a eficiência dos elevadores não é tida em consideração. A ausência de legislação específica, que torne a análise da eficiência energética dos elevadores obrigatória, será um dos problemas referidos. Reforça-se que, a potencialidade de poupança energética na Europa não deve ser desprezada.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A evolução dos acidentes graves envolvendo substâncias perigosas ocorridos no Sector Químico, não deixa dúvidas de que as características intrínsecas da própria actividade industrial podem estimular a ocorrência dos acidentes graves, proporcionando sérias consequências à Comunidade envolvente, à própria Propriedade e ao meio ambiente, cujas responsabilidades estão inseridas na Gestão Empresarial. Desta forma torna-se fundamental o desenvolvimento e implementação de um Sistema de Gestão de Segurança para a Prevenção de Acidentes Graves num Estabelecimento de Nível Superior de Perigosidade. O objectivo global deste trabalho, baseia-se no estabelecimento de um Quadro Metodológico de aplicação do Regime de Prevenção de Acidentes Graves ao Sector Químico, suportado num Sistema de Gestão de Segurança para a Prevenção de Acidentes Graves (SGSPAG) e no respectivo Manual de Implementação. Para tal foi realizado um enquadramento teórico, técnico-científico, e legal da prevenção de acidentes graves que envolvam substâncias perigosas, a concepção de um SGSPAG e elaboração do Manual de Implementação e a aplicação a um Caso de Estudo Industrial do SGSPAG com a correspondente análise crítica. O contexto específico foi o da Refinaria de Sines - Instalação de Dessulfuração de Gasóleo. A pesquisa foi acompanhada por um conjunto de métodos que permitiram uma visão mais actual do assunto no contexto seleccionado (dados adquiridos através de referências bibliográficas, da observação in-loco de auditorias de SGSPAG, da consulta de documentação relativa a auditorias SGSPAG e do estudo da legislação vigente e passada). Os resultados obtidos no Caso de Estudo Industrial, demonstraram que uma visão mais integradora e global podem contribuir para um melhor entendimento dos acidentes graves envolvendo substâncias perigosas e a sua prevenção, possibilitando um envolvimento maior e o comprometimento efectivo de todos, sejam eles trabalhadores (internos ou serviços subcontratados), Chefes de Secção, Responsáveis de Área, fornecedores, profissionais de outras áreas, Direcção da Empresa, representantes sindicais ou governamentais ou a própria Comunidade envolvente, estando o SGSPAG da Refinaria de Sines globalmente concebido, implementado e a demonstrar aptidão para, de uma forma consistente, cumprir os requisitos aplicáveis no DL nº 254/2007 e atingir os objectivos da Politica de Prevenção de Acidentes Graves.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The importance of Social Responsibility (SR) is higher if this business variable is related with other ones of strategic nature in business activity (competitive success that the company achieved, performance that the firms develop and innovations that they carries out). The hypothesis is that organizations that focus on SR are those who get higher outputs and innovate more, achieving greater competitive success. A scale for measuring the orientation to SR has defined in order to determine the degree of relationship between above elements. This instrument is original because previous scales do not exist in the literature which could measure, on the one hand, the three classics sub-constructs theoretically accepted that SR is made up and, on the other hand, the relationship between SR and the other variables. As a result of causal relationships analysis we conclude with a scale of 21 indicators, validated scale with a sample of firms belonging to the Autonomous Community of Extremadura and it is the first empirical validation of these dimensions we know so far, in this context.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O presente trabalho teve como objectivos avaliar a influência de diversas grandezas e parâmetros de ensaio no índice de fluidez de termoplásticos e calcular a incerteza associada às determinações. Numa primeira fase, procedeu-se à identificação dos principais parâmetros que influenciam a determinação do índice de fluidez, tendo sido seleccionados a temperatura do plastómetro, o peso de carga, o diâmetro da fieira, o comprimento da medição, o tipo de corte e o número de provetes. Para avaliar a influência destes parâmetros na medição do índice de fluidez, optou-se pela realização de um planeamento de experiências, o qual foi dividido em três etapas. Para o tratamento dos resultados obtidos utilizou-se como ferramenta a análise de variância. Após a completa análise dos desenhos factoriais, verificou-se que os efeitos dos factores temperatura do plastómetro, peso de carga e diâmetro da fieira apresentam um importante significado estatístico na medição do índice de fluidez. Na segunda fase, procedeu-se ao cálculo da incerteza associada às medições. Para tal seleccionou-se um dos métodos mais usuais, referido no Guia para a Expressão da Incerteza da Medição, conhecido como método GUM, e pela utilização da abordagem “passo a passo”. Inicialmente, foi necessária a construção de um modelo matemático para a medição do índice de fluidez que relacionasse os diferentes parâmetros utilizados. Foi estudado o comportamento de cada um dos parâmetros através da utilização de duas funções, recorrendo-se novamente à análise de variância. Através da lei de propagação das incertezas foi possível determinar a incerteza padrão combinada,e após estimativa do número de graus de liberdade, foi possível determinar o valor do coeficiente de expansão. Finalmente determinou-se a incerteza expandida da medição, relativa à determinação do índice de fluidez em volume.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mestrado em Tecnologia de Diagnóstico e Intervenção. Área de especialização: Ultrassonografia Cardiovascular.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was the assessment of exposure to ultrafine in the urban environment of Lisbon, Portugal, due to automobile traffic, and consisted of the determination of deposited alveolar surface area in an avenue leading to the town center during late spring. This study revealed differentiated patterns for weekdays and weekends, which could be related with the fluxes of automobile traffic. During a typical week, ultrafine particles alveolar deposited surface area varied between 35.0 and 89.2 μm2/cm3, which is comparable with levels reported for other towns such in Germany and the United States. These measurements were also complemented by measuring the electrical mobility diameter (varying from 18.3 to 128.3 nm) and number of particles that showed higher values than those previously reported for Madrid and Brisbane. Also, electron microscopy showed that the collected particles were composed of carbonaceous agglomerates, typical of particles emitted by the exhaustion of diesel vehicles. Implications: The approach of this study considers the measurement of surface deposited alveolar area of particles in the outdoor urban environment of Lisbon, Portugal. This type of measurements has not been done so far. Only particulate matter with aerodynamic diameters <2.5 (PM2.5) and >10 (PM10) μm have been measured in outdoor environments and the levels found cannot be found responsible for all the observed health effects. Therefore, the exposure to nano- and ultrafine particles has not been assessed systematically, and several authors consider this as a real knowledge gap and claim for data such as these that will allow for deriving better and more comprehensive epidemiologic studies. Nanoparticle surface area monitor (NSAM) equipments are recent ones and their use has been limited to indoor atmospheres. However, as this study shows, NSAM is a very powerful tool for outdoor environments also. As most lung diseases are, in fact, related to deposition of the alveolar region of the lung, the metric used in this study is the ideal one.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objetivo – Comparar a técnica convencional, a técnica de energias mistas e a técnica field-in-field com energias mistas, verificando a dose recebida nos órgãos de risco e no volume alvo. Metodologia – Quinze doentes com carcinoma da mama esquerda classificadas de T1-T3N0M0 foram tratadas com cirurgia conservadora da mama, seguida de radioterapia pós-operatória. Para cada doente realizaram-se 3 planeamentos dosimétricos, sendo que cada um deles diz respeito a uma das diferentes técnicas em estudo. Através dos HDV gerados avaliaram-se a Dmáx, Dmed, Dmín, D95%, D3% e a homogeneidade da dose no volume alvo, bem como a dose nos órgãos de risco. Utilizou-se o teste de Friedman para verificar a significância do estudo, com um intervalo de confiança de 95%. Resultados – Relativamente ao pulmão esquerdo e ao coração obtiveram-se, com a técnica field-in-field com energias mistas, doses inferiores em comparação com as outras duas técnicas. Para a Dmáx e a homogeneidade de dose no PTV, a técnica field-in-field com energias mistas revelou-se mais eficaz, comparativamente às outras técnicas. No entanto, verificou-se uma melhor cobertura de dose no PTV com a técnica convencional. Considerações finais – A técnica field-in-field com energias mistas permite uma redução da dose nos órgãos de risco, uma redução significativa da Dmáx no PTV e melhora a homogeneidade da dose, comparativamente com as outras técnicas. Os resultados obtidos com a técnica field-in-field com energias mistas apontam para a redução dos efeitos secundários provocados pelo tratamento. ABSTRACT - Purpose – To compare the conventional technique, the technique of mixed energies and the technique field-in-field with mixed energies, checking the received dose in organs at risk and target volume. Methods – Fifteen patients with carcinoma of the left breast classified as T1-T3N0M0 were treated with breast-conserving surgery, followed by postoperative radiotherapy. For each patient were carried out three dosimetric plannings, each one of them concerns the different techniques under study. Through the DVH generated to evaluate Dmax, Dmed, Dmin, D95%, D3% and the homogeneity of the target volume dose, well as the dose in organs at risk. We used the Friedman test to assess the significance of the study, with a confidence interval of 95%. Results – For the left lung and heart were obtained with the technique field-in-field with mixed energies, lower doses compared with the other two techniques. For the Dmax and the homogeneity of the PTV dose, the technique field-in-field with mixed energies was more effective compared to other techniques. However, there was a better coverage of the PTV dose with conventional technique. Conclusions – The technique field-in-field with mixed energy allows a reduction in dose for organs at risk, a significant reduction Dmax in PTV and improves the homogeneity of the dose compared with other techniques. The results obtained with the technique field-in-field with mixed energy indicate to reduce the side effects caused by the treatment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dust is a complex mixture of particles of organic and inorganic origin and different gases absorbed in aerosol droplets. In a poultry unit include dried faecal matter and urine, skin flakes, ammonia, carbon dioxide, pollens, feed and litter particles, feathers, grain mites, fungi spores, bacteria, viruses and their constituents. Dust particles vary in size and differentiation between particle size fractions is important in health studies in order to quantify penetration within the respiratory system. A descriptive study was developed in order to assess exposure to particles in a poultry unit during different operations, namely routine examination and floor turn over. Direct-reading equipment was used (Lighthouse, model 3016 IAQ). Particle measurement was performed in 5 different sizes (PM0.5; PM1.0; PM2.5; PM5.0; PM10). The chemical composition of poultry litter was also determined by neutron activation analysis. Normally, the litter of poultry pavilions is turned over weekly and it was during this operation that the higher exposure of particles was observed. In all the tasks considered PM5.0 and PM10.0 were the sizes with higher concentrations values. PM10 is what turns out to have higher values and PM0.5 the lowest values. The chemical element with the highest concentration was Mg (5.7E6 mg.kg-1), followed by K (1.5E4 mg.kg-1), Ca (4.8E3 mg.kg-1), Na (1.7E3 mg.kg-1), Fe (2.1E2 mg.kg-1) and Zn (4.2E1 mg.kg-1). This high presence of particles in the respirable range (<5–7μm) means that poultry dust particles can penetrate into the gas exchange region of the lung. Larger particles (PM10) present a range of concentrations from 5.3E5 and 3.0E6 mg/m3.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introdução: O cancro retal continua a ser um dos principais problemas de saúde a nível mundial, sendo a toxicidade gastro-intestinal e génito-urinária os efeitos tardios da radioterapia mais reportados. A utilização da Belly-Board para minimizar essa toxicidade, reduzindo o volume de bexiga e intestino delgado irradiados é recomendada. No entanto, o protocolo mais adequado para o volume vesical nestes doentes é ainda tema de controvérsia. Objetivo: Avaliar a influência do volume vesical na dose recebida na bexiga e no PTV, em doentes com tumor de reto, posicionados em decúbito ventral, com belly-board. Materiais e Métodos: 38 doentes com tumor de reto tratados no CHBM, agrupados em dois grupos: o 1º grupo, com 19 doentes que realizaram tratamento com bexiga cheia e o 2º grupo, com 19 doentes que realizaram tratamento com bexiga vazia. Os dados foram obtidos através dos HDV’s e foram comparadas as doses máximas no PTV e a percentagem de volume de bexiga que recebe 50Gy. Foi utilizado o teste estatístico U-Mann Whitney com um nível de significância de 0,05. A hipótese de pesquisa deste estudo propõe que os dois grupos diferem significativamente entre si e a hipótese nula propõe que os dois grupos não diferem significativamente entre si, para ambas as variáveis. Resultados: Não se observaram diferenças estatisticamente significativas entre os grupos no que diz respeito à dose máxima no PTV. No que se refere à percentagem de volume de bexiga que recebe 50Gy verificaram-se diferenças estatisticamente significativas, tendo o grupo de doentes que realizaram tratamento com bexiga cheia apresentado valores mais baixos. Conclusões: Este estudo demonstrou o benefício da utilização do protocolo de bexiga cheia em doentes com tumor de reto tratados com belly-board, na diminuição da percentagem de volume de bexiga que recebe 50Gy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introdução - A prevalência da doença pulmonar obstrutiva crónica (DPOC) apresenta valores muito heterogéneos em todo o mundo. A iniciativa Burden of Obstructive Lung Disease (BOLD) foi desenvolvida para que a prevalência da DPOC possa ser avaliada com metodologia uniformizada. O objetivo deste estudo foi estimar a prevalência da DPOC em adultos com 40 ou mais anos numa população alvo de 2 700 000 habitantes na região de Lisboa, de acordo com o protocolo BOLD. Métodos - A amostra foi estratificada de forma aleatória multifaseada selecionando-se 12 freguesias. O inquérito compreendia um questionário com informação sobre fatores de risco para a DPOC e doença respiratória autoreportada; adicionalmente, foi efetuada espirometria com prova de broncodilatação. Resultados - Foram incluídos 710 participantes com questionário e espirometria aceitáveis. A prevalência estimada da DPOC na população no estadio GOLD I+ foi de 14,2% (IC 95%: 11,1; 18,1) e de 7,3% no estadio ii+ (IC 95%: 4,7; 11,3). A prevalência não ajustada foi de 20,2% (IC 95%: 17,4; 23,3) no estadio i+ e de 9,5% (IC 95%: 7,6; 11,9) no estadio ii+. A prevalência da DPOC no estadio GOLD II+ aumentou com a idade, sendo mais elevada no sexo masculino. A prevalência estimada da DPOC no estadio GOLD I+ foi de 9,2% (IC 95%: 5,9; 14,0) nos não fumadores versus 27,4% (IC 95%: 18,5; 38,5) nos fumadores com carga tabágica de ≥ 20 Unidades Maço Ano. Detetou-se uma fraca concordância entre a referência a diagnóstico médico prévio e o diagnóstico espirométrico, com 86,8% de subdiagnósticos. Conclusões - O achado de uma prevalência estimada da DPOC de 14,2% sugere que esta é uma doença comum na região de Lisboa, contudo com uma elevada proporção de subdiagnósticos. Estes dados apontam para a necessidade de aumentar o grau de conhecimento dos profissionais de saúde sobre a DPOC, bem como a necessidade de maior utilização da espirometria nos cuidados de saúde primários.