14 resultados para Lung volume
em Repositório Científico do Instituto Politécnico de Lisboa - Portugal
Resumo:
Mestrado em Radioterapia
Resumo:
Introduction: Standard Uptake Value (SUV) is a measurement of the uptake in a tumour normalized on the basis of a distribution volume and is used to quantify 18F-Fluorodeoxiglucose (FDG) uptake in tumors, such as primary lung tumor. Several sources of error can affect its accuracy. Normalization can be based on body weight, body surface area (BSA) and lean body mass (LBM). The aim of this study is to compare the influence of 3 normalization volumes in the calculation of SUV: body weight (SUVW), BSA (SUVBSA) and LBM (SUVLBM), with and without glucose correction, in patients with known primary lung tumor. The correlation between SUV and weight, height, blood glucose level, injected activity and time between injection and image acquisition is evaluated. Methods: Sample included 30 subjects (8 female and 22 male) with primary lung tumor, with clinical indication for 18F-FDG Positron Emission Tomography (PET). Images were acquired on a Siemens Biography according to the department’s protocol. Maximum pixel SUVW was obtained for abnormal uptake focus through semiautomatic VOI with Quantification 3D isocontour (threshold 2.5). The concentration of radioactivity (kBq/ml) was obtained from SUVW, SUVBSA, SUVLBM and the glucose corrected SUV were mathematically obtained. Results: Statistically significant differences between SUVW, SUVBSA and SUVLBM and between SUVWgluc, SUVBSAgluc and SUVLBMgluc were observed (p=0.000<0.05). The blood glucose level showed significant positive correlations with SUVW (r=0.371; p=0.043) and SUVLBM (r=0.389; p=0.034). SUVBSA showed independence of variations with the blood glucose level. Conclusion: The measurement of a radiopharmaceutical tumor uptake normalized on the basis of different distribution volumes is still variable. Further investigation on this subject is recommended.
Resumo:
O principal objectivo do estudo é determinar uma fórmula de cálculo para o volume de ultrafiltrado a retirar, pela Ultrafiltração Modificada (UFM), a doentes adultos submetidos a cirurgia cardíaca. A população-alvo é constituída por 489 casos relativos às cirurgias cardíacas realizadas entre Janeiro de 2003 e Dezembro de 2005, que cumprem os critérios de inclusão e exclusão definidos. Trata-se de um estudo retrospectivo, do tipo correlacional quantitativo com abordagem dedutiva, em que as variáveis estudadas foram obtidas através da consulta dos relatórios de perfusão cardiovascular do serviço de Cirurgia Cardiotorácica do Hospital de Santa Marta, EPE. A relação entre as variáveis em estudo foi analisada através da correlação e modelos de regressão linear. O modelo obtido para definir a fórmula de cálculo desejada tem por base a correlação existente entre o volume a retirar por UFM e a superfície corporal do doente, sendo este o único dos três modelos estudados que demonstra uma dependência, ainda que fraca, entre as variáveis, e exprimindo-se através da fórmula Y=545,4.X3, em que Y é o volume a retirar por UFM e X é o valor da superfície corporal de cada doente, e sendo representativo apenas para 4% da população em estudo.” O aumento médio de hemoglobina pós-UFM é de 1,9±1,09g/ dl, o que traduz eficácia da técnica na obtenção de hemoconcentração.
Resumo:
Este estudo analisa o modo como se desenvolve a aprendizagem do conceito de volume nos alunos do 6º ano de escolaridade, no quadro de uma proposta pedagógica que dá ênfase a actividades que apelam à visualização e ao raciocínio espacial. O seu objectivo principal foi o de compreender as ideias que os alunos do 6.º ano têm sobre volume e perceber como se desenvolvem quando são envolvidos numa experiência de ensino, tendo por base uma cadeia de tarefas que apelam à visualização e ao raciocínio espacial. O estudo seguiu uma metodologia de investigação qualitativa baseada em estudos de caso. A proposta pedagógica foi desenvolvida em quatro aulas; três de noventa minutos e uma de quarenta e cinco minutos, durante os 2º e 3º períodos do ano lectivo de 2009/2010. A recolha de dados envolveu a realização de gravações áudio, em ambiente de sala de aula, dos alunos que constituíram os estudos de caso, registo de observações do desempenho dos alunos e os documentos produzidos por estes. Os resultados mostram que, ao longo da proposta pedagógica, os alunos adquiriram estratégias de contagem que lhes permitiram criar estruturas, para compreender a organização dos paralelepípedos e desenvolver o conceito de volume. iii ABSTRACT This study examines how 6th graders’ students develop the concept of volume in a learning experience context which emphasizes the visualization and spatial reasoning. The main objective of this study is to understand the ideas of 6th grade students about volume and see how they develop them when they are involved in a learning experience, based on a sequence of tasks that call for visualization and spatial reasoning. The study followed a qualitative research methodology based on case studies. The learning experience was developed in four classes, three ninety minutes period and one forty-five minutes, during the 2nd and 3rd terms of the school year 2009/2010. Data collection involved the use of audio recordings in the classroom environment, recording observations of student performance and the documents produced by them. The results showed that, over the learning experience, students acquired counting strategies that allowed them to create structures for understanding the organization of cubes arrays and develop the concept of volume.
Resumo:
A evolução dos acidentes graves envolvendo substâncias perigosas ocorridos no Sector Químico, não deixa dúvidas de que as características intrínsecas da própria actividade industrial podem estimular a ocorrência dos acidentes graves, proporcionando sérias consequências à Comunidade envolvente, à própria Propriedade e ao meio ambiente, cujas responsabilidades estão inseridas na Gestão Empresarial. Desta forma torna-se fundamental o desenvolvimento e implementação de um Sistema de Gestão de Segurança para a Prevenção de Acidentes Graves num Estabelecimento de Nível Superior de Perigosidade. O objectivo global deste trabalho, baseia-se no estabelecimento de um Quadro Metodológico de aplicação do Regime de Prevenção de Acidentes Graves ao Sector Químico, suportado num Sistema de Gestão de Segurança para a Prevenção de Acidentes Graves (SGSPAG) e no respectivo Manual de Implementação. Para tal foi realizado um enquadramento teórico, técnico-científico, e legal da prevenção de acidentes graves que envolvam substâncias perigosas, a concepção de um SGSPAG e elaboração do Manual de Implementação e a aplicação a um Caso de Estudo Industrial do SGSPAG com a correspondente análise crítica. O contexto específico foi o da Refinaria de Sines - Instalação de Dessulfuração de Gasóleo. A pesquisa foi acompanhada por um conjunto de métodos que permitiram uma visão mais actual do assunto no contexto seleccionado (dados adquiridos através de referências bibliográficas, da observação in-loco de auditorias de SGSPAG, da consulta de documentação relativa a auditorias SGSPAG e do estudo da legislação vigente e passada). Os resultados obtidos no Caso de Estudo Industrial, demonstraram que uma visão mais integradora e global podem contribuir para um melhor entendimento dos acidentes graves envolvendo substâncias perigosas e a sua prevenção, possibilitando um envolvimento maior e o comprometimento efectivo de todos, sejam eles trabalhadores (internos ou serviços subcontratados), Chefes de Secção, Responsáveis de Área, fornecedores, profissionais de outras áreas, Direcção da Empresa, representantes sindicais ou governamentais ou a própria Comunidade envolvente, estando o SGSPAG da Refinaria de Sines globalmente concebido, implementado e a demonstrar aptidão para, de uma forma consistente, cumprir os requisitos aplicáveis no DL nº 254/2007 e atingir os objectivos da Politica de Prevenção de Acidentes Graves.
Resumo:
Mestrado em Tecnologia de Diagnóstico e Intervenção. Área de especialização: Ultrassonografia Cardiovascular.
Resumo:
Objetivo – Comparar a técnica convencional, a técnica de energias mistas e a técnica field-in-field com energias mistas, verificando a dose recebida nos órgãos de risco e no volume alvo. Metodologia – Quinze doentes com carcinoma da mama esquerda classificadas de T1-T3N0M0 foram tratadas com cirurgia conservadora da mama, seguida de radioterapia pós-operatória. Para cada doente realizaram-se 3 planeamentos dosimétricos, sendo que cada um deles diz respeito a uma das diferentes técnicas em estudo. Através dos HDV gerados avaliaram-se a Dmáx, Dmed, Dmín, D95%, D3% e a homogeneidade da dose no volume alvo, bem como a dose nos órgãos de risco. Utilizou-se o teste de Friedman para verificar a significância do estudo, com um intervalo de confiança de 95%. Resultados – Relativamente ao pulmão esquerdo e ao coração obtiveram-se, com a técnica field-in-field com energias mistas, doses inferiores em comparação com as outras duas técnicas. Para a Dmáx e a homogeneidade de dose no PTV, a técnica field-in-field com energias mistas revelou-se mais eficaz, comparativamente às outras técnicas. No entanto, verificou-se uma melhor cobertura de dose no PTV com a técnica convencional. Considerações finais – A técnica field-in-field com energias mistas permite uma redução da dose nos órgãos de risco, uma redução significativa da Dmáx no PTV e melhora a homogeneidade da dose, comparativamente com as outras técnicas. Os resultados obtidos com a técnica field-in-field com energias mistas apontam para a redução dos efeitos secundários provocados pelo tratamento. ABSTRACT - Purpose – To compare the conventional technique, the technique of mixed energies and the technique field-in-field with mixed energies, checking the received dose in organs at risk and target volume. Methods – Fifteen patients with carcinoma of the left breast classified as T1-T3N0M0 were treated with breast-conserving surgery, followed by postoperative radiotherapy. For each patient were carried out three dosimetric plannings, each one of them concerns the different techniques under study. Through the DVH generated to evaluate Dmax, Dmed, Dmin, D95%, D3% and the homogeneity of the target volume dose, well as the dose in organs at risk. We used the Friedman test to assess the significance of the study, with a confidence interval of 95%. Results – For the left lung and heart were obtained with the technique field-in-field with mixed energies, lower doses compared with the other two techniques. For the Dmax and the homogeneity of the PTV dose, the technique field-in-field with mixed energies was more effective compared to other techniques. However, there was a better coverage of the PTV dose with conventional technique. Conclusions – The technique field-in-field with mixed energy allows a reduction in dose for organs at risk, a significant reduction Dmax in PTV and improves the homogeneity of the dose compared with other techniques. The results obtained with the technique field-in-field with mixed energy indicate to reduce the side effects caused by the treatment.
Resumo:
Introdução: O cancro retal continua a ser um dos principais problemas de saúde a nível mundial, sendo a toxicidade gastro-intestinal e génito-urinária os efeitos tardios da radioterapia mais reportados. A utilização da Belly-Board para minimizar essa toxicidade, reduzindo o volume de bexiga e intestino delgado irradiados é recomendada. No entanto, o protocolo mais adequado para o volume vesical nestes doentes é ainda tema de controvérsia. Objetivo: Avaliar a influência do volume vesical na dose recebida na bexiga e no PTV, em doentes com tumor de reto, posicionados em decúbito ventral, com belly-board. Materiais e Métodos: 38 doentes com tumor de reto tratados no CHBM, agrupados em dois grupos: o 1º grupo, com 19 doentes que realizaram tratamento com bexiga cheia e o 2º grupo, com 19 doentes que realizaram tratamento com bexiga vazia. Os dados foram obtidos através dos HDV’s e foram comparadas as doses máximas no PTV e a percentagem de volume de bexiga que recebe 50Gy. Foi utilizado o teste estatístico U-Mann Whitney com um nível de significância de 0,05. A hipótese de pesquisa deste estudo propõe que os dois grupos diferem significativamente entre si e a hipótese nula propõe que os dois grupos não diferem significativamente entre si, para ambas as variáveis. Resultados: Não se observaram diferenças estatisticamente significativas entre os grupos no que diz respeito à dose máxima no PTV. No que se refere à percentagem de volume de bexiga que recebe 50Gy verificaram-se diferenças estatisticamente significativas, tendo o grupo de doentes que realizaram tratamento com bexiga cheia apresentado valores mais baixos. Conclusões: Este estudo demonstrou o benefício da utilização do protocolo de bexiga cheia em doentes com tumor de reto tratados com belly-board, na diminuição da percentagem de volume de bexiga que recebe 50Gy.
Resumo:
Introdução - A prevalência da doença pulmonar obstrutiva crónica (DPOC) apresenta valores muito heterogéneos em todo o mundo. A iniciativa Burden of Obstructive Lung Disease (BOLD) foi desenvolvida para que a prevalência da DPOC possa ser avaliada com metodologia uniformizada. O objetivo deste estudo foi estimar a prevalência da DPOC em adultos com 40 ou mais anos numa população alvo de 2 700 000 habitantes na região de Lisboa, de acordo com o protocolo BOLD. Métodos - A amostra foi estratificada de forma aleatória multifaseada selecionando-se 12 freguesias. O inquérito compreendia um questionário com informação sobre fatores de risco para a DPOC e doença respiratória autoreportada; adicionalmente, foi efetuada espirometria com prova de broncodilatação. Resultados - Foram incluídos 710 participantes com questionário e espirometria aceitáveis. A prevalência estimada da DPOC na população no estadio GOLD I+ foi de 14,2% (IC 95%: 11,1; 18,1) e de 7,3% no estadio ii+ (IC 95%: 4,7; 11,3). A prevalência não ajustada foi de 20,2% (IC 95%: 17,4; 23,3) no estadio i+ e de 9,5% (IC 95%: 7,6; 11,9) no estadio ii+. A prevalência da DPOC no estadio GOLD II+ aumentou com a idade, sendo mais elevada no sexo masculino. A prevalência estimada da DPOC no estadio GOLD I+ foi de 9,2% (IC 95%: 5,9; 14,0) nos não fumadores versus 27,4% (IC 95%: 18,5; 38,5) nos fumadores com carga tabágica de ≥ 20 Unidades Maço Ano. Detetou-se uma fraca concordância entre a referência a diagnóstico médico prévio e o diagnóstico espirométrico, com 86,8% de subdiagnósticos. Conclusões - O achado de uma prevalência estimada da DPOC de 14,2% sugere que esta é uma doença comum na região de Lisboa, contudo com uma elevada proporção de subdiagnósticos. Estes dados apontam para a necessidade de aumentar o grau de conhecimento dos profissionais de saúde sobre a DPOC, bem como a necessidade de maior utilização da espirometria nos cuidados de saúde primários.
Resumo:
Mestrado em Radioterapia
Resumo:
This work aims at investigating the impact of treating breast cancer using different radiation therapy (RT) techniques – forwardly-planned intensity-modulated, f-IMRT, inversely-planned IMRT and dynamic conformal arc (DCART) RT – and their effects on the whole-breast irradiation and in the undesirable irradiation of the surrounding healthy tissues. Two algorithms of iPlan BrainLAB treatment planning system were compared: Pencil Beam Convolution (PBC) and commercial Monte Carlo (iMC). Seven left-sided breast patients submitted to breast-conserving surgery were enrolled in the study. For each patient, four RT techniques – f-IMRT, IMRT using 2-fields and 5-fields (IMRT2 and IMRT5, respectively) and DCART – were applied. The dose distributions in the planned target volume (PTV) and the dose to the organs at risk (OAR) were compared analyzing dose–volume histograms; further statistical analysis was performed using IBM SPSS v20 software. For PBC, all techniques provided adequate coverage of the PTV. However, statistically significant dose differences were observed between the techniques, in the PTV, OAR and also in the pattern of dose distribution spreading into normal tissues. IMRT5 and DCART spread low doses into greater volumes of normal tissue, right breast, right lung and heart than tangential techniques. However, IMRT5 plans improved distributions for the PTV, exhibiting better conformity and homogeneity in target and reduced high dose percentages in ipsilateral OAR. DCART did not present advantages over any of the techniques investigated. Differences were also found comparing the calculation algorithms: PBC estimated higher doses for the PTV, ipsilateral lung and heart than the iMC algorithm predicted.
Resumo:
The calculation of the dose is one of the key steps in radiotherapy planning1-5. This calculation should be as accurate as possible, and over the years it became feasible through the implementation of new algorithms to calculate the dose on the treatment planning systems applied in radiotherapy. When a breast tumour is irradiated, it is fundamental a precise dose distribution to ensure the planning target volume (PTV) coverage and prevent skin complications. Some investigations, using breast cases, showed that the pencil beam convolution algorithm (PBC) overestimates the dose in the PTV and in the proximal region of the ipsilateral lung. However, underestimates the dose in the distal region of the ipsilateral lung, when compared with analytical anisotropic algorithm (AAA). With this study we aim to compare the performance in breast tumors of the PBC and AAA algorithms.
Resumo:
Mestrado em Tecnologia de Diagnóstico e Intervenção Cardiovascular - Ramo de especialização: Ultrassonografia Cardiovascular
Resumo:
Introduction - Poultry workers can be at an increased risk of occupational respiratory diseases, like asthma, chronic obstructive pulmonary disease and extrinsic allergic alveolitis. Spirometry screening is fundamental to early diagnosis trough the identification of related ventilatory defects. Purpose - We aimed to assess the prevalence of lung function abnormalities in poultry workers.