15 resultados para Languages of signs of visual codes
em Repositório Científico do Instituto Politécnico de Lisboa - Portugal
Resumo:
This study aimed to determine and evaluate the diagnostic accuracy of visual screening tests for detecting vision loss in elderly. This study is defined as study of diagnostic performance. The diagnostic accuracy of 5 visual tests -near convergence point, near accommodation point, stereopsis, contrast sensibility and amsler grid—was evaluated by means of the ROC method (receiver operating characteristics curves), sensitivity, specificity, positive and negative likelihood ratios (LR+/LR−). Visual acuity was used as the reference standard. A sample of 44 elderly aged 76.7 years (±9.32), who were institutionalized, was collected. The curves of contrast sensitivity and stereopsis are the most accurate (area under the curves were 0.814−p = 0.001, C.I.95%[0.653;0.975]— and 0.713−p = 0.027, C.I.95%[0,540;0,887], respectively). The scores with the best diagnostic validity for the stereopsis test were 0.605 (sensitivity 0.87, specificity 0.54; LR+ 1.89, LR−0.24) and 0.610 (sensitivity 0.81, specificity 0.54; LR+1.75, LR−0.36). The scores with higher diagnostic validity for the contrast sensibility test were 0.530 (sensitivity 0.94, specificity 0.69; LR+ 3.04, LR−0.09). The contrast sensitivity and stereopsis test's proved to be clinically useful in detecting vision loss in the elderly.
Resumo:
The aging of Portuguese population is characterized by an increase of individuals aged older than 65 years. Preventable visual loss in older persons is an important public health problem. Tests used for vision screening should have a high degree of diagnostic validity confirmed by means of clinical trials. The primary aim of a screening program is the early detection of visual diseases. Between 20% and 50% of older people in the UK have undetected reduced vision and in most cases is correctable. Elderly patients do not receive a systematic eye examination unless a problem arises with their glasses or suspicion vision loss. This study aimed to determine and evaluate the diagnostic accuracy of visual screening tests for detecting vision loss in elderly. Furthermore, it pretends to define the ability to find the subjects affected with vision loss as positive and the subjects not affected with the same disease as negative. The ideal vision screening method should have high sensitivity and specificity for early detection of risk factors. It should be also low cost and easy to implement in all geographic and socioeconomic regions. Sensitivity is the ability of an examination to identify the presence of a given disease and specificity is the ability of the examination to identify the absence of a given disease. It was not an aim of this study to detect abnormalities that affect visual acuity. The aim of this study was to find out what´s the best test for the identification of any vision loss.
Resumo:
There are few professions in which visual acuity is as important as it is to radiologists. The diagnostic decision making process is composed of a number of events (detection or observation, interpretation and reporting), where the detection phase is subject to a number of physical and psychological phenomena that are critical to the process. Visual acuity is one phenomenon that has often been overlooked, and there is very little research assessing the impact of reduced visual acuity on diagnostic performance. The aim of this study was to investigate the impact of reduced visual acuity on an observer’s ability to detect simulated nodules in an anthropomorphic chest phantom.
Resumo:
Purpose: a) multiply handicapped children have a high incidence of disorders affecting the visual system; b) assessment and management of visual disorders in this group of children presents a complex challenge; c) this study describes the results of visual function assessment in two children with neurological disability over a one-year period.
Resumo:
The aim of this study is to evaluate lighting conditions and speleologists’ visual performance using optical filters when exposed to the lighting conditions of cave environments. A crosssectional study was conducted. Twenty-three speleologists were submitted to an evaluation of visual function in a clinical lab. An examination of visual acuity, contrast sensitivity, stereoacuity and flashlight illuminance levels was also performed in 16 of the 23 speleologists at two caves deprived of natural lightning. Two organic filters (450 nm and 550 nm) were used to compare visual function with and without filters. The mean age of the speleologists was 40.65 (± 10.93) years. We detected 26.1% participants with visual impairment of which refractive error (17.4%) was the major cause. In the cave environment the majority of the speleologists used a head flashlight with a mean illuminance of 451.0 ± 305.7 lux. Binocular visual acuity (BVA) was -0.05 ± 0.15 LogMAR (20/18). BVA for distance without filter was not statistically different from BVA with 550 nm or 450 nm filters (p = 0.093). Significant improved contrast sensitivity was observed with 450 nm filters for 6 cpd (p = 0.034) and 18 cpd (p = 0.026) spatial frequencies. There were no signs and symptoms of visual pathologies related to cave exposure. Illuminance levels were adequate to the majority of the activities performed. The enhancement in contrast sensitivity with filters could potentially improve tasks related with the activities performed in the cave.
Resumo:
Aim: Visual acuity outcome of amblyopia treatment depends on the compliance. This study aimed to determine parental predictors of poor visual outcome with occlusion treatment in unilateral amblyopia and identify the relationship between occlusion recommendations and the patient's actual dose of occlusion reported by the parents. Methods: This study comprised three phases: refractive adaptation for a period of 18 weeks after spectacle correction; occlusion of 3 to 6 hours per day during a period of 6 months; questionnaire administration and completion by parents. Visual acuity as assessed using the Sheridan-Gardiner singles or Snellen acuity chart was used as a measure of visual outcome. Correlation analysis was used to describe the strength and direction of two variables: prescribed occlusion reported by the doctor and actual dose reported by parents. A logistic binary model was adjusted using the following variables: severity, vulnerability, self-efficacy, behaviour intentions, perceived efficacy and treatment barriers, parents' and childrens' age, and parents' level of education. Results: The study included 100 parents (mean age 38.9 years, SD approx 9.2) of 100 children (mean age 6.3 years, SD approx 2.4) with amblyopia. Twenty-eight percent of children had no improvement in visual acuity. The results showed a positive mild correlation (kappa = 0.54) between the prescribed occlusion and actual dose reported by parents. Three predictors for poor visual outcome with occlusion were identified: parents' level of education (OR = 9.28; 95%CI 1.32-65.41); treatment barriers (OR = 2.75; 95%CI 1.22-6.20); interaction between severity and vulnerability (OR = 3.64; 95%CI 1.21-10.93). Severity (OR = 0.07; 95%CI 0.00-0.72) and vulnerability (OR = 0.06; 95%CI 0.05-0.74) when considered in isolation were identified as protective factors. Conclusions: Parents frequently do not use the correct dosage of occlusion as recommended. Parents' educational level and awareness of treatment barriers were predictors of poor visual outcome. Lower levels of education represented a 9-times higher risk of having a poor visual outcome with occlusion treatment.
Resumo:
Purpose - In this study we aim to validate a method to assess the impact of reduced visual function and observer performance concurrently with a nodule detection task. Materials and methods - Three consultant radiologists completed a nodule detection task under three conditions: without visual defocus (0.00 Dioptres; D), and with two different magnitudes of visual defocus (−1.00 D and −2.00 D). Defocus was applied with lenses and visual function was assessed prior to each image evaluation. Observers evaluated the same cases on each occasion; this comprised of 50 abnormal cases containing 1–4 simulated nodules (5, 8, 10 and 12 mm spherical diameter, 100 HU) placed within a phantom, and 25 normal cases (images containing no nodules). Data was collected under the free-response paradigm and analysed using Rjafroc. A difference in nodule detection performance would be considered significant at p < 0.05. Results - All observers had acceptable visual function prior to beginning the nodule detection task. Visual acuity was reduced to an unacceptable level for two observers when defocussed to −1.00 D and for one observer when defocussed to −2.00 D. Stereoacuity was unacceptable for one observer when defocussed to −2.00 D. Despite unsatisfactory visual function in the presence of defocus we were unable to find a statistically significant difference in nodule detection performance (F(2,4) = 3.55, p = 0.130). Conclusion - A method to assess visual function and observer performance is proposed. In this pilot evaluation we were unable to detect any difference in nodule detection performance when using lenses to reduce visual function.
Resumo:
Purpose: It is important to establish a differential diagnosis between the different types of nystagmus, in order to give the appropriate clinical approach to every situation and to improve visual acuity. The nystagmus is normally blocked when the eyes are positioned in a particular way. This makes the child adopt a posture of ocular torticollis that reduces the nistagmiformes movements, improving the vision in this position. A way to promote the blocking of the nystagmic movements is by using prismatic lenses with opposite bases, to block or minimize the oscillatory movements. This results in a vision improvement and it reduces the anomalous head position. There is limited research on the visual results in children with nystagmus after using prisms with opposing bases. Our aim is to describe the impact on the visual acuity (VA ) of theprescription prism lenses in a nystagmus patient starting at 3 months of age. Methods: Case report on thirty month old caucasian male infant, with normal growth and development for their age, with an early onset of horizontal nystagmus at 3 months of age. Ophthalmic examination included slit lamp examination, fundus, refractive study, electrophysiological and magnetic resonance tests, measurement of VA over time with the Teller Acuity Cards (TAC ) in the distance agreed for the age. At age ten months, the mother noted a persistent turn to the right of the child’s head, which became increasingly more severe along the months. There’s no oscillopcia. At 24 months, an atropine refraction showed the following refractive error: 0D.: -1,50, OS: -0,50 and prismatic lens adapting OD 8 Δ nasal base and OE 8 Δ temporal base. Results: Thirty month old child, with adequate development for their age, with onset of idiopatic horizontal nystagmus, at 3 months of age. Normal ocular fundus and magnetic ressoance without alterations, sub-normal results in electrophysiological tests and VA with values below normal for age. At 6 months OD 20/300; OE 20/400; OU 20/300. At 9 months OD 20/250; OE 20/300; OU 20/150 (TAC a 38 cm). At 18 months OD 20/200; OE 20/100; OU 20/80 (TAC at 38 cm), when the head is turned to the right and the eyes in levoversão, the nystagmus decreases in a “neutral” area. At 24 month, with the prismatic glasses, OD 20/200 OE 20/100, OU20/80 (TAC at 54 cm, reference value is 20/30 – 20/100 para OU e 20/40 – 20/100 monocular), there was an increase in the visual acuity. The child did visual stimulation with multimedia devices and using glasses. After adaptation of prisms: at 30 months VA (with Cambridge cards) OD e OE = 6/18. The child improved the VA and reduced the anomalous head position. There is also improvement in mobility and fine motricity. Conclusion: Prisms with opposing bases., were used in the treatment of idiopathic nystagmus. Said prisms were adapted to reduce the skewed position of the head, and to improve VA and binocular function. Monitoring of visual acuity and visual stimulation was done using electronic devices. Following the use of prismatic, the patient improved significantly VA and the anomalous head position was reduced.
Resumo:
Introduction: The purpose of this review is to gather and analyse current research publications to evaluate Sinogram-Affirmed Iterative Reconstruction (SAFIRE). The aim of this review is to investigate whether this algorithm is capable of reducing the dose delivered during CT imaging while maintaining image quality. Recent research shows that children have a greater risk per unit dose due to increased radiosensitivity and longer life expectancies, which means it is particularly important to reduce the radiation dose received by children. Discussion: Recent publications suggest that SAFIRE is capable of reducing image noise in CT images, thereby enabling the potential to reduce dose. Some publications suggest a decrease in dose, by up to 64% compared to filtered back projection, can be accomplished without a change in image quality. However, literature suggests that using a higher SAFIRE strength may alter the image texture, creating an overly ‘smoothed’ image that lacks contrast. Some literature reports SAFIRE gives decreased low contrast detectability as well as spatial resolution. Publications tend to agree that SAFIRE strength three is optimal for an acceptable level of visual image quality, but more research is required. The importance of creating a balance between dose reduction and image quality is stressed. In this literature review most of the publications were completed using adults or phantoms, and a distinct lack of literature for paediatric patients is noted. Conclusion: It is necessary to find an optimal way to balance dose reduction and image quality. More research relating to SAFIRE and paediatric patients is required to fully investigate dose reduction potential in this population, for a range of different SAFIRE strengths.
Resumo:
Introdução – Na avaliação diagnóstica em mamografia, o desempenho do radiologista pode estar sujeito a erros de diagnóstico. Objetivo – Descrever a importância da perceção visual na análise da mamografia, identificando os principais fatores que contribuem para a perceção visual do radiologista e que condicionam a acuidade diagnóstica. Metodologia – Estudo descritivo baseado numa revisão sistemática de literatura através da PubMed e da Science Direct. Foram incluídos 42 artigos que respeitavam, pelo menos, um dos critérios de inclusão no estudo. Para a seleção das referências foi utilizada a metodologia PRISMA, constituída por 4 fases: identificação, seleção preliminar, elegibilidade e estudos incluídos. Resultados – Na avaliação diagnóstica em mamografia, a perceção visual está intimamente relacionada com: 1) diferentes parâmetros visuais e da motilidade ocular (acuidade visual, sensibilidade ao contraste e à luminância e movimentos oculares); 2) com condições de visualização de uma imagem (iluminância da sala e luminância do monitor); e 3) fadiga ocular provocada pela observação diária consecutiva de imagens. Conclusões – A perceção visual pode ser influenciada por 3 categorias de erros observados: erros de pesquisa (lesões não são fixadas pela fóvea), erros de reconhecimento (lesões fixadas, mas não durante o tempo suficiente) e erros de decisão (lesões fixadas, mas não identificadas como suspeitas). Os estudos analisados sobre perceção visual, atenção visual e estratégia visual, bem como os estudos sobre condições de visualização não caracterizam a função visual dos observadores. Para uma avaliação correta da perceção visual em mamografia deverão ser efetuados estudos que correlacionem a função visual com a qualidade diagnóstica. ABSTRACT - Introduction – Diagnostic evaluation in mammography could be influenced by the radiologist performance that could be under diagnostic errors. Aims – To describe the importance of radiologist visual perception in mammographic diagnostic evaluation and to identify the main factors that contribute to diagnostic accuracy. Methods – In this systematic review 42 references were included based on inclusion criteria (PubMed and Science Direct). PRISMA method was used to select the references following 4 steps: identification, screening, eligibility and included references. Results – Visual perception in mammography diagnostic evaluation is related with: 1) visual parameters and ocular motility (visual acuity, contrast sensitivity and luminance and ocular movements); 2) image visualization environment (room iluminance and monitor luminance); and 3) eyestrain caused by image daily consecutive observation. Conclusions – Visual perception can be influenced by three errors categories: search errors (lesions are never looked at with high-resolution foveal vision), recognition errors (lesions are looked at, but not long enough to detect or recognize) and decision errors (lesions are looked at for long periods of time but are still missed). The reviewed studies concerning visual perception, visual attention, visual strategies and image visualization environment do not describe observer’s visual function. An accurate evaluation of visual perception in mammography must include visual function analysis.
Insuficiência de convergência e atenção visual: estudo exploratório em estudantes do ensino superior
Resumo:
RESUMO: Introdução – A insuficiência de convergência (IC) pode desencadear alterações da atenção visual. Pretende-se investigar se existem alterações na atenção visual em estudantes do ensino superior com IC. Metodologia – Estudo quantitativo, comparativo e correlacional. Participaram 44 estudantes com idades compreendidas entre os 18 e os 24 anos. Formaram-se dois grupos, um com Visão Binocular Normal (VBN) e outro com IC. O grupo com IC incluiu os indivíduos que apresentaram alterações no ponto próximo de convergência (PPC) e/ou na convergência para perto (C’). Para avaliar a atenção visual utilizou-se o teste de cancelamento de sinos. Resultados – O grupo com VBN foi composto por 32 indivíduos (23 do género feminino) e o grupo com IC por 12 indivíduos (11 do género feminino). No teste de atenção visual verificou-se que o número médio de sinos identificados foi de 34,6 para o grupo com VBN e de 34,3 no grupo com IC. O tempo médio de realização do teste foi de 167,9s e de 198,3s para os grupos de VBN e IC, respetivamente. Observou-se uma correlação moderada positiva entre o PPC e o tempo médio de realização do teste (r≈0,63) e uma correlação fraca positiva entre o número médio de sinos identificados e a C’ (r≈0,16). Por outro lado, a correlação entre o PPC e o número médio de sinos identificados (r≈-0,48) foi fraca negativa e entre a C’ e o tempo médio (r≈-0,05) foi ínfima negativa. Discussão/Conclusões – O grupo com VBN apresenta um número médio de sinos identificados superior ao grupo com IC. Verifica-se ainda que o grupo com IC demorou mais tempo na realização do teste, comparativamente com o grupo com VBN. Estes resultados apontam para uma possível relação entre a IC e a diminuição da atenção visual.
Resumo:
To become an open to outer space, the "museum" acquired new forms and new expressions. The complexity of museological activity thus leads to new representations that alter the initial image of the museum as a building with objects. Their 'boundaries' are now less sharp, not only in relation to the spatial relationship, but also to its temporal dimension, creating an additional challenge which is the recognition of the museum itself. The design, while transdisciplinary activity, thereby assumes a key role in the communication of the museums in its visual representation and recognition of their action. The present study results from a survey conducted in 2010 to 364 Portuguese museums (from a universe of 849 museums), presenting an analysis to its base elements of visual expression of identity (name, logo, symbol, and color).
Resumo:
Preventable visual loss in children is an important public health problem. The critical period of susceptibility to deprivation or abnormal visual experience has been identified since the early 1970s. Preventable visual loss caused by amblyopia (0.3%–4%) and its risk factors such as strabismus (2.1%–4.6%) and uncorrected refractive errors (5%–7.7%) represent an important public health problem. Thus the primary justification for preschool vision screening is the detection of amblyopia or amblyogenic refractive, strabismic, or ocular disease conditions. However in Portugal there has been little investigation regarding prevalence of visual anomalies among school-age children. Data on the prevalence are lacking but are needed for planning vision services. Aims: 1) Determine the prevalence of strabismus; 2) Determine the prevalence of decreased visual acuity; 3) Determine the prevalence of uncorrected refractive error.
Resumo:
Speleologist’s perform their activity in demanding visual conditions of very low luminance - many visual tasks involve resolution of detail under conditions of low contrast. Work related conditions in a cave as exposure to heat, chemicals, dust and poor lighting conditions could influence the integrity of the visual system and predispose the eye to diseases that eventually affect vision. Poor lighting conditions cause a variety of symptoms of visual discomfort and may increase the risk of accidents. Good visual acuity is crucial for several and has an important role for safety purposes. The aim of this study was to evaluate lighting conditions and optical filters effects on visual performance in speleologists exposed to cave environments.
Resumo:
Introdução – A cintigrafia de perfusão do miocárdio (CPM) desempenha um importante papel no diagnóstico, avaliação e seguimento de pacientes com doença arterial coronária, sendo o seu processamento realizado maioritariamente de forma semiautomática. Uma vez que o desempenho dos técnicos de medicina nuclear (TMN) pode ser afetado por fatores individuais e ambientais, diferentes profissionais que processem os mesmos dados poderão obter diferentes estimativas dos parâmetros quantitativos (PQ). Objetivo – Avaliar a influência da experiência profissional e da função visual no processamento semiautomático da CPM. Analisar a variabilidade intra e interoperador na determinação dos PQ funcionais e de perfusão. Metodologia – Selecionou-se uma amostra de 20 TMN divididos em dois grupos, de acordo com a sua experiência no software Quantitative Gated SPECTTM: Grupo A (GA) – TMN ≥600h de experiência e Grupo B (GB) – TMN sem experiência. Submeteram-se os TMN a uma avaliação ortóptica e ao processamento de 21 CPM, cinco vezes, não consecutivas. Considerou-se uma visão alterada quando pelo menos um parâmetro da função visual se encontrava anormal. Para avaliar a repetibilidade e a reprodutibilidade recorreu-se à determinação dos coeficientes de variação, %. Na comparação dos PQ entre operadores, e para a análise do desempenho entre o GA e GB, aplicou-se o Teste de Friedman e de Wilcoxon, respetivamente, considerando o processamento das mesmas CPM. Para a comparação de TMN com visão normal e alterada na determinação dos PQ utilizou-se o Teste Mann-Whitney e para avaliar a influência da visão para cada PQ recorreu-se ao coeficiente de associação ETA. Diferenças estatisticamente significativas foram assumidas ao nível de significância de 5%. Resultados e Discussão – Verificou-se uma reduzida variabilidade intra (<6,59%) e inter (<5,07%) operador. O GB demonstrou ser o mais discrepante na determinação dos PQ, sendo a parede septal (PS) o único PQ que apresentou diferenças estatisticamente significativas (zw=-2,051, p=0,040), em detrimento do GA. No que se refere à influência da função visual foram detetadas diferenças estatisticamente significativas apenas na fração de ejeção do ventrículo esquerdo (FEVE) (U=11,5, p=0,012) entre TMN com visão normal e alterada, contribuindo a visão em 33,99% para a sua variação. Denotaram-se mais diferenças nos PQ obtidos em TMN que apresentam uma maior incidência de sintomatologia ocular e uma visão binocular diminuída. A FEVE demonstrou ser o parâmetro mais consistente entre operadores (1,86%). Conclusão – A CPM apresenta-se como uma técnica repetível e reprodutível, independente do operador. Verificou-se influência da experiência profissional e da função visual no processamento semiautomático da CPM, nos PQ PS e FEVE, respetivamente.