13 resultados para LOW DOSE-RATE BRACHYTHERAPY
em Repositório Científico do Instituto Politécnico de Lisboa - Portugal
Resumo:
Purpose/Objective: The purpose of this work was to determine biologically equivalent alternative regimens for the treatment of prostate cancer using External Beam Radiotherapy (EBRT) and Low Dose-Rate Brachytherapy (LDRBT) with 125I implants and to evaluate the sensitivity of these regimens to different sets of radiobiological parameters of the Linear-Quadratic (LQ) model.
Resumo:
Aim - To use Monte Carlo (MC) together with voxel phantoms to analyze the tissue heterogeneity effect in the dose distributions and equivalent uniform dose (EUD) for (125)I prostate implants. Background - Dose distribution calculations in low dose-rate brachytherapy are based on the dose deposition around a single source in a water phantom. This formalism does not take into account tissue heterogeneities, interseed attenuation, or finite patient dimensions effects. Tissue composition is especially important due to the photoelectric effect. Materials and Methods - The computed tomographies (CT) of two patients with prostate cancer were used to create voxel phantoms for the MC simulations. An elemental composition and density were assigned to each structure. Densities of the prostate, vesicles, rectum and bladder were determined through the CT electronic densities of 100 patients. The same simulations were performed considering the same phantom as pure water. Results were compared via dose-volume histograms and EUD for the prostate and rectum. Results - The mean absorbed doses presented deviations of 3.3-4.0% for the prostate and of 2.3-4.9% for the rectum, when comparing calculations in water with calculations in the heterogeneous phantom. In the calculations in water, the prostate D 90 was overestimated by 2.8-3.9% and the rectum D 0.1cc resulted in dose differences of 6-8%. The EUD resulted in an overestimation of 3.5-3.7% for the prostate and of 7.7-8.3% for the rectum. Conclusions - The deposited dose was consistently overestimated for the simulation in water. In order to increase the accuracy in the determination of dose distributions, especially around the rectum, the introduction of the model-based algorithms is recommended.
Resumo:
Introduction: multimodality environment; requirement for greater understanding of the imaging technologies used, the limitations of these technologies, and how to best interpret the results; dose optimization; introduction of new techniques; current practice and best practice; incidental findings, in low-dose CT images obtained as part of the hybrid imaging process, are an increasing phenomenon with advancing CT technology; resultant ethical and medico-legal dilemmas; understanding limitations of these procedures important when reporting images and recommending follow-up; free-response observer performance study was used to evaluate lesion detection in low-dose CT images obtained during attenuation correction acquisitions for myocardial perfusion imaging, on two hybrid imaging systems.
Resumo:
Purpose: To evaluate if physical measures of noise predict image quality at high and low noise levels. Method: Twenty-four images were acquired on a DR system using a Pehamed DIGRAD phantom at three kVp settings (60, 70 and 81) across a range of mAs values. The image acquisition setup consisted of 14 cm of PMMA slabs with the phantom placed in the middle at 120 cm SID. Signal-to-noise ratio (SNR) and Contrast-tonoise ratio (CNR) were calculated for each of the images using ImageJ software and 14 observers performed image scoring. Images were scored according to the observer`s evaluation of objects visualized within the phantom. Results: The R2 values of the non-linear relationship between objective visibility score and CNR (60kVp R2 = 0.902; 70Kvp R2 = 0.913; 80kVp R2 = 0.757) demonstrate a better fit for all 3 kVp settings than the linear R2 values. As CNR increases for all kVp settings the Object Visibility also increases. The largest increase for SNR at low exposure values (up to 2 mGy) is observed at 60kVp, when compared with 70 or 81kVp.CNR response to exposure is similar. Pearson r was calculated to assess the correlation between Score, OV, SNR and CNR. None of the correlations reached a level of statistical significance (p>0.01). Conclusion: For object visibility and SNR, tube potential variations may play a role in object visibility. Higher energy X-ray beam settings give lower SNR but higher object visibility. Object visibility and CNR at all three tube potentials are similar, resulting in a strong positive relationship between CNR and object visibility score. At low doses the impact of radiographic noise does not have a strong influence on object visibility scores because in noisy images objects could still be identified.
Resumo:
Background - For dose reduction actions, the principle of “image quality as good as possible” to “image quality as good as needed” requires to know whether the physical measures and visual image quality relate. Visual evaluation and objective physical measures of image quality can appear to be different. If there is no noticeable effect on the visual image quality with a low dose but there is a objective physical measure impact, then the overall dose may be reduced without compromising the diagnostic image quality. Low dose imaging can be used for certain types of observations, e.g. thoracic scoliosis, control after metal implantation for osteosynthesis, reviewing pneumonia and tuberculosis. Aim of the study - To determine whether physical measures of noise predict visual (clinical) image quality at low dose levels.
Resumo:
Incidental findings on low-dose CT images obtained during hybrid imaging are an increasing phenomenon as CT technology advances. Understanding the diagnostic value of incidental findings along with the technical limitations is important when reporting image results and recommending follow-up, which may result in an additional radiation dose from further diagnostic imaging and an increase in patient anxiety. This study assessed lesions incidentally detected on CT images acquired for attenuation correction on two SPECT/CT systems. Methods: An anthropomorphic chest phantom containing simulated lesions of varying size and density was imaged on an Infinia Hawkeye 4 and a Symbia T6 using the low-dose CT settings applied for attenuation correction acquisitions in myocardial perfusion imaging. Twenty-two interpreters assessed 46 images from each SPECT/CT system (15 normal images and 31 abnormal images; 41 lesions). Data were evaluated using a jackknife alternative free-response receiver-operating-characteristic analysis (JAFROC). Results: JAFROC analysis showed a significant difference (P < 0.0001) in lesion detection, with the figures of merit being 0.599 (95% confidence interval, 0.568, 0.631) and 0.810 (95% confidence interval, 0.781, 0.839) for the Infinia Hawkeye 4 and Symbia T6, respectively. Lesion detection on the Infinia Hawkeye 4 was generally limited to larger, higher-density lesions. The Symbia T6 allowed improved detection rates for midsized lesions and some lower-density lesions. However, interpreters struggled to detect small (5 mm) lesions on both image sets, irrespective of density. Conclusion: Lesion detection is more reliable on low-dose CT images from the Symbia T6 than from the Infinia Hawkeye 4. This phantom-based study gives an indication of potential lesion detection in the clinical context as shown by two commonly used SPECT/CT systems, which may assist the clinician in determining whether further diagnostic imaging is justified.
Resumo:
Frame rate upconversion (FRUC) is an important post-processing technique to enhance the visual quality of low frame rate video. A major, recent advance in this area is FRUC based on trilateral filtering which novelty mainly derives from the combination of an edge-based motion estimation block matching criterion with the trilateral filter. However, there is still room for improvement, notably towards reducing the size of the uncovered regions in the initial estimated frame, this means the estimated frame before trilateral filtering. In this context, proposed is an improved motion estimation block matching criterion where a combined luminance and edge error metric is weighted according to the motion vector components, notably to regularise the motion field. Experimental results confirm that significant improvements are achieved for the final interpolated frames, reaching PSNR gains up to 2.73 dB, on average, regarding recent alternative solutions, for video content with varied motion characteristics.
Resumo:
Objective: Summarize all relevant findings in published literature regarding the potential dose reduction related to image quality using Sinogram-Affirmed Iterative Reconstruction (SAFIRE) compared to Filtered Back Projection (FBP). Background: Computed Tomography (CT) is one of the most used radiographic modalities in clinical practice providing high spatial and contrast resolution. However it also delivers a relatively high radiation dose to the patient. Reconstructing raw-data using Iterative Reconstruction (IR) algorithms has the potential to iteratively reduce image noise while maintaining or improving image quality of low dose standard FBP reconstructions. Nevertheless, long reconstruction times made IR unpractical for clinical use until recently. Siemens Medical developed a new IR algorithm called SAFIRE, which uses up to 5 different strength levels, and poses an alternative to the conventional IR with a significant reconstruction time reduction. Methods: MEDLINE, ScienceDirect and CINAHL databases were used for gathering literature. Eleven articles were included in this review (from 2012 to July 2014). Discussion: This narrative review summarizes the results of eleven articles (using studies on both patients and phantoms) and describes SAFIRE strengths for noise reduction in low dose acquisitions while providing acceptable image quality. Conclusion: Even though the results differ slightly, the literature gathered for this review suggests that the dose in current CT protocols can be reduced at least 50% while maintaining or improving image quality. There is however a lack of literature concerning paediatric population (with increased radiation sensitivity). Further studies should also assess the impact of SAFIRE on diagnostic accuracy.
Resumo:
Introdução – A monitorização da exposição ocupacional a doses de radiação ionizante pode ser complementada por dosímetros eletrónicos individuais que permitem uma leitura direta da dose de radiação recebida. Dada a dependência energética e de débito de dose já reportada para estes dosímetros, este trabalho pretende determinar a linearidade da resposta de um dosímetro eletrónico individual e estudar o comportamento da sua resposta em função da energia de radiação e do débito de dose. Metodologia – Para estudar a dependência da energia da radiação do dosímetro eletrónico pessoal Vertec Bleeper Sv procedeu‑se à sua irradiação com um equivalente de dose individual, Hp(10), de 500 μSv de radiação gama do Cobalto – 60 (60C) e Césio – 137 (137Cs) e das qualidades de radiação X da série Narrow (N): N‑30, N‑40, N‑60, N‑80, N‑100 e N‑120. Para investigar a dependência da resposta em função do débito de dose aplicaram‑se à ampola de raios X as intensidades de corrente elétrica de 1 mA, 5 mA, 10 mA, 15 mA e 20 mA. Resultados – Não existe uma relação entre a resposta do detetor e a energia de radiação a que este é exposto. Ocorre uma subestimação superior a 50% na grandeza medida para energias inferiores a 33 keV, mas ostenta uma medida relativamente linear da grandeza Hp(10) para doses inferiores a 100 μSv. Também se constata que, à medida que o débito de dose aumenta, existe uma diminuição na resposta do dosímetro. O menor decréscimo na resposta deste dosímetro eletrónico individual dá‑se para as qualidades de radiação N‑30 (1,1%), N‑40 (4,1%) e N‑120 (20,0%). Conclusão – Verifica‑se que a resposta do dosímetro individual Vertec Bleeper Sv depende fortemente da energia da radiação e do débito de dose. ABSTRACT: Introduction – The measurement of occupational exposure to radiation doses can be completed with an electronic personal dosemeter that allows a direct reading and alarm function of the received radiation dose. Due to the energy and dose rate dependence already reported for this type of dosemeter, it is intended, with this work, to determine the response linearity of an Electronic Personal Dosemeter and to study its response behavior to the dose rate and radiation energy. Methodology – The electronic personal dosemeter Vertec Bleeper Sv energy dependency was evaluated by its irradiation with 500 μSv from the radionuclides Cobalt – 60 (60C) and Cesium – 137 (137Cs) as well as by the radiation qualities of the Narrow (N) series: N‑30, N‑40, N‑60, N‑80, N‑100 e N‑120. To investigate the dose rate dependency, the intensities of electric current of 1 mA, 5 mA, 10 mA, 15 mA and 20 mA were applied to the X‑ray tube. Results – There is no relationship between the response of the detector and the radiation energy. For energies below 33 keV there is an underestimation over 50% of the radiation dose measured but the detector presents a linear response for energies under 100 μSv. A dependency on the dose rate is perceived since as the dose rate increases, the response of the individual monitor decreases. There is a smaller decrease for the radiation qualities of N‑30 (1.1%), N‑40 (4.1%) and N‑120 (20.0%). Conclusion – It is concluded that there is a strong dependence of radiation energy and dose rate on the response of an electronic personal dosemeter.
Resumo:
Mestrado em Medicina Nuclear.
Resumo:
Objective - The study evaluated the effect of a canned sardine supplement in C-reactive protein (CRP) in patients on hemodialysis (HD) and the compliance and adherence to this supplement. Design - This was a quasi-experimental study: Participants with a serum CRP of 5 mg/dL or less volunteered to consume a sardine supplement or were maintained on the usual cheese/ham sandwich supplement. Setting - The study took place in two outpatient dialysis units in Lisbon, Portugal. Patients - The study comprised 63 patients receiving maintenance HD three times per week for at least 6 months and an initial CRP concentration of 5 mg/dL or less. Exclusion criteria included the presence of graft vascular access or history of cancer. Intervention - After a 4-week washout period, the nutritional intervention included a canned sardine sandwich for the case group (n = 31) and a cheese or ham sandwich for the control group (n = 32), to be ingested during each routine HD session, 3 times per week, for 8 weeks. Main outcome measure - Serum levels of high-sensitivity CRP were the outcome measure. Results - Only 65 patients from the invited 186 patients met the inclusion criteria and agreed to eat the sardine sandwich supplement three times per week and were involved in the study. A significant proportion of 48% (n = 31, case group) consumed the sardine sandwich supplement three times per week for 8 weeks, fulfilling the requirements and completing the study. The present investigation showed that a sardine sandwich supplement had no effect on CRP levels among patients on HD. However, when participants were stratified according to tertiles of CRP distribution values at baseline, a reduction in CRP levels was found for those in the higher tertile, being higher for the case group (P = .047). Although diabetic patients were excluded from the analysis (eight in the sardine supplementation group and seven in the control group) a significant CRP reduction was found (P = .034). Conclusion - Although a supplement of low-dose n-3 long-chain polyunsaturated fatty acids had no effect on the plasma high-sensitivity CRP of the supplemented group, a reduction in CRP levels was found when patients were stratified for tertiles of CRP (for the upper tertile) and diabetic status (for nondiabetic patients). These findings need to be further confirmed. This canned sardine supplement was accepted by an important proportion of patients, enhancing diet variety and contributing for a greater n-3 long-chain polyunsaturated fatty acids eicosapentaenoic acid and docosahexaenoic acid intake.
Resumo:
The consumption of natural products has become a public health problem, since these medicinal teas are prepared using natural plants without an effective hygienic and sanitary control. The aim of this study was to assess the effects of gamma radiation, on the microbial burden of two medicinal plants: Melissa officinalis and Lippia citriodora. Dried samples of the two plants were irradiated at a Co-60 experimental equipment. The applied gamma radiation doses were 1, 3, and 5 kGy at a dose rate of 1.34 kGy/h. Non-irradiated samples followed all the experiments. Bacterial and fungal counts were assessed before and after irradiation by membrane filtration method. Challenging tests with Escherichia coli were performed in order to evaluate the disinfection efficiency of gamma radiation treatment. Characterization of M. officinalis and L. citriadora microbiota indicated an average bioburden value of 102CFU/g. The inactivation studies of the bacterial mesophilic population of both dried plants pointed out to a one log reduction of microbial load after irradiation at 5 kGy. Regarding the fungal population, the initial load of 30 CFU/g was only reduced by 0.5 log by an irradiation dose of 5 kGy. The dynamics with radiation doses of plants microbial population’s phenotypes indicated the prevalence of gram-positive rods for M. officinalis before and after irradiation, and the increase of the frequency of gram-negative rods with irradiation for L. citriadora. Among fungal population of both plants, Mucor, Neoscytalidium, Aspergillus and Alternaria were the most isolated genera. The results obtained in the challenging tests with E. coli on plants pointed out to an inactivation efficiency of 99.5% and 99.9% to a dose of 2 kGy, for M.officinalis and L. citriadora, respectively. The gamma radiation treatment can be a significant tool for the microbial control in medicinal plants.
Resumo:
Since long ago cellulosic lyotropic liquid crystals were thought as potential materials to produce fibers competitive with spidersilk or Kevlar, yet the processing of high modulus materials from cellulose-based precursors was hampered by their complex rheological behavior. In this work, by using the Rheo-NMR technique, which combines deuterium NMR with rheology, we investigate the high shear rate regimes that may be of interest to the industrial processing of these materials. Whereas the low shear rate regimes were already investigated by this technique in different works [1-4], the high shear rates range is still lacking a detailed study. This work focuses on the orientational order in the system both under shear and subsequent relaxation process arising after shear cessation through the analysis of deuterium spectra from the deuterated solvent water. At the analyzed shear rates the cholesteric order is suppressed and a flow-aligned nematic is observed which for the higher shear rates develops after certain time periodic perturbations that transiently annihilate the order in the system. During relaxation the flow aligned nematic starts losing order due to the onset of the cholesteric helices leading to a period of very low order where cholesteric helices with different orientations are forming from the aligned nematic, followed in the final stage by an increase in order at long relaxation times corresponding to the development of aligned cholesteric domains. This study sheds light on the complex rheological behavior of chiral nematic cellulose-based systems and opens ways to improve its processing. (C) 2015 Elsevier Ltd. All rights reserved.