23 resultados para LIKELIHOOD RATIO TESTS

em Repositório Científico do Instituto Politécnico de Lisboa - Portugal


Relevância:

80.00% 80.00%

Publicador:

Resumo:

We propose a blind method to detect interference in GNSS signals whereby the algorithms do not require knowledge of the interference or channel noise features. A sample covariance matrix is constructed from the received signal and its eigenvalues are computed. The generalized likelihood ratio test (GLRT) and the condition number test (CNT) are developed and compared in the detection of sinusoidal and chirp jamming signals. A computationally-efficient decision threshold was proposed for the CNT.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study aimed to determine and evaluate the diagnostic accuracy of visual screening tests for detecting vision loss in elderly. This study is defined as study of diagnostic performance. The diagnostic accuracy of 5 visual tests -near convergence point, near accommodation point, stereopsis, contrast sensibility and amsler grid—was evaluated by means of the ROC method (receiver operating characteristics curves), sensitivity, specificity, positive and negative likelihood ratios (LR+/LR−). Visual acuity was used as the reference standard. A sample of 44 elderly aged 76.7 years (±9.32), who were institutionalized, was collected. The curves of contrast sensitivity and stereopsis are the most accurate (area under the curves were 0.814−p = 0.001, C.I.95%[0.653;0.975]— and 0.713−p = 0.027, C.I.95%[0,540;0,887], respectively). The scores with the best diagnostic validity for the stereopsis test were 0.605 (sensitivity 0.87, specificity 0.54; LR+ 1.89, LR−0.24) and 0.610 (sensitivity 0.81, specificity 0.54; LR+1.75, LR−0.36). The scores with higher diagnostic validity for the contrast sensibility test were 0.530 (sensitivity 0.94, specificity 0.69; LR+ 3.04, LR−0.09). The contrast sensitivity and stereopsis test's proved to be clinically useful in detecting vision loss in the elderly.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aging of Portuguese population is characterized by an increase of individuals aged older than 65 years. Preventable visual loss in older persons is an important public health problem. Tests used for vision screening should have a high degree of diagnostic validity confirmed by means of clinical trials. The primary aim of a screening program is the early detection of visual diseases. Between 20% and 50% of older people in the UK have undetected reduced vision and in most cases is correctable. Elderly patients do not receive a systematic eye examination unless a problem arises with their glasses or suspicion vision loss. This study aimed to determine and evaluate the diagnostic accuracy of visual screening tests for detecting vision loss in elderly. Furthermore, it pretends to define the ability to find the subjects affected with vision loss as positive and the subjects not affected with the same disease as negative. The ideal vision screening method should have high sensitivity and specificity for early detection of risk factors. It should be also low cost and easy to implement in all geographic and socioeconomic regions. Sensitivity is the ability of an examination to identify the presence of a given disease and specificity is the ability of the examination to identify the absence of a given disease. It was not an aim of this study to detect abnormalities that affect visual acuity. The aim of this study was to find out what´s the best test for the identification of any vision loss.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fluorescent protein microscopy imaging is nowadays one of the most important tools in biomedical research. However, the resulting images present a low signal to noise ratio and a time intensity decay due to the photobleaching effect. This phenomenon is a consequence of the decreasing on the radiation emission efficiency of the tagging protein. This occurs because the fluorophore permanently loses its ability to fluoresce, due to photochemical reactions induced by the incident light. The Poisson multiplicative noise that corrupts these images, in addition with its quality degradation due to photobleaching, make long time biological observation processes very difficult. In this paper a denoising algorithm for Poisson data, where the photobleaching effect is explicitly taken into account, is described. The algorithm is designed in a Bayesian framework where the data fidelity term models the Poisson noise generation process as well as the exponential intensity decay caused by the photobleaching. The prior term is conceived with Gibbs priors and log-Euclidean potential functions, suitable to cope with the positivity constrained nature of the parameters to be estimated. Monte Carlo tests with synthetic data are presented to characterize the performance of the algorithm. One example with real data is included to illustrate its application.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Neste trabalho estudou-se a lixiviação em meio sulfúrico do zinco e outros metais de valor de um concentrado zinco, tendo-se realizado ensaios de lixiviação à pressão atmosférica e em autoclave. Nos estudos de lixiviação utilizou-se o ião férrico (sulfato férrico) como agente oxidante e avaliaram-se os efeitos de diversas variáveis como a razão sólido/líquido, concentração do ião Fe (III), temperatura, a pressão de oxigénio e a presença de enxofre elementar na eficiência da lixiviação. Os ensaios de lixiviação em autoclave sob pressão de oxigénio foram realizados para verificar o efeito da manutenção da quantidade de Fe (III) na lixívia, por oxidação do Fe(II) com oxigénio. Os resultados obtidos mostraram que à pressão atmosférica para uma razão sólido/líquido de 5% foi possível lixiviar no máximo 59% de zinco e 22% de cobre com solução de 0,25 M de Fe2(SO4)3 e 0,50 M de H2SO4 em 2 horas a 60ºC e com uma razão sólido/líquido de 5% foi possível lixiviar no máximo 65% de zinco e 23% de cobre com uma solução de 0,5 M de Fe2(SO4)3 e 0,25 M de H2SO4 em 2 horas a 80ºC. Efectuar a lixiviação do concentrado de zinco sobre pressão de oxigénio permitiu aumentar a cinética da reacção de lixiviação, tendo sido possível lixiviar 97% de zinco e 48% do cobre em 2 horas de lixiviação com uma solução de 0,25 M Fe2(SO4)3 e 0,5 M H2SO4 a 95 ºC e a 6 bar de pressão de oxigénio (à entrada do reactor) com uma razão sólido/líquido de 5%. Utilizando razão sólido/líquido de 10 % foi possível lixiviar 93% de zinco e 54% do cobre com uma solução de 0,50 M Fe2(SO4)3 e 1,25 M H2SO4 a 95 ºC e a 6 bar de pressão de oxigénio, e para uma razão sólido/líquido de 20 % foi possível lixiviar 84% de zinco e 39% do cobre com uma solução de 0,11 M Fe2(SO4)3 e 2,00 M H2SO4 a 95 ºC e a 10 bar de pressão. As análises de difracção de Raios X efectuados aos resíduos de lixiviação revelaram que o enxofre era maioritariamente oxidado a enxofre elementar. Assim, para um dos ensaios de lixiviação em autoclave, verificou-se que a remoção com tetracloreto de carbono do enxofre elementar formado num primeiro andar de lixiviação (s/l=20%, 0,11 M Fe2(SO4)3 e 2,00 M H2SO4 a 95 ºC e a 10 bar de pressão) permitia aumentar a percentagem de zinco no segundo andar de 42 para 68%. Por último, o estudo do efeito da temperatura permitiu calcular como base nas velocidades iniciais do zinco a energia de activação para a lixiviação do zinco que foi de 39 ± 1.40 kJ/mol para a lixiviação em autoclave e de 38 ± 1.40 kJ/mol para a lixiviação à pressão atmosférica, o que é indicativo do controlo reaccional.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O principal objectivo desta tese é obter uma relação directa entre a composição dos gases liquefeitos de petróleo (GLP), propano, n-butano e isobutano, usados como aerossóis propulsores numa lata de poliuretano de um componente, com as propriedades das espumas produzidas por spray. As espumas obtidas, terão de ter como requisito principal, um bom desempenho a temperaturas baixas, -10ºC, sendo por isso designadas por espumas de Inverno. Uma espuma é considerada como tendo um bom desempenho se não apresentar a -10/-10ºC (temperatura lata/ spray) glass bubbles, base holes e cell collapse. As espumas deverão ainda ter densidades do spray no molde a +23/+23ºC abaixo dos 30 g/L, um rendimento superior a 30 L, boa estabilidade dimensional e um caudal de espuma a +5/+5ºC superior a 5 g/s. Os ensaios experimentais foram realizados a +23/+23ºC, +5/+5ºC e a -10/-10ºC. A cada temperatura, as espumas desenvolvidas, foram submetidas a testes que permitiram determinar a sua qualidade. Testes esses que incluem os designados por Quick Tests (QT): o spray no papel e no molde das espumas nas referidas temperaturas. As amostras do papel e no molde são especialmente analisadas, quanto, às glass bubbles, cell collapse, base holes, cell structur e, cutting shrinkage, para além de outras propriedades. Os QT também incluem a análise da densidade no molde (ODM) e o estudo do caudal de espumas. Além dos QT foram realizados os testes da estabilidade dimensional das espumas, testes físicos de compressão e adesão, testes de expansão das espumas após spray e do rendimento por lata de espuma. Em todos os ensaios foi utilizado um tubo adaptador colocado na válvula da lata como método de spray e ainda mantida constante a proporção das matérias-primas (excepto os gases, em estudo). As experiências iniciaram-se com o estudo de GLPs presentes no mercado de aerossóis. Estes resultaram que o GLP: propano/ n-butano/ isobutano: (30/ 0/ 70 w/w%), produz as melhores espumas de inverno a -10/-10ºC, reduzindo desta forma as glass bubbles, base holes e o cell collapse produzido pelos restantes GLP usados como aerossóis nas latas de poliuretano. Testes posteriores tiveram como objectivo estudar a influência directa de cada gás, propano, n-butano e isobutano nas espumas. Para tal, foram usadas duas referências do estudo com GLP comercializáveis, 7396 (30 /0 /70 w/w %) e 7442 (0/ 0/ 100 w/w %). Com estes resultados concluí-se que o n-butano produz más propriedades nas espumas a -10/- 10ºC, formando grandes quantidades de glass bubbles, base holes e cell collapse. Contudo, o uso de propano reduz essas glass bubbles, mas em contrapartida, forma cell collapse.Isobutano, porém diminui o cell collapse mas não as glass bubbles. Dos resultados experimentais podemos constatar que o caudal a +5/+5ºC e densidade das espumas a +23/+23ºC, são influenciados pela composição do GLP. O propano e n-butano aumentam o caudal de espuma das latas e a sua densidade, ao contrário com o que acontece com o isobutano. Todavia, pelos resultados obtidos, o isobutano proporciona os melhores rendimentos de espumas por lata. Podemos concluir que os GLPs que contivessem cerca de 30 w/w % de propano (bons caudais a +5/+5ºC e menos glass bubbles a -10/-10ºC), e cerca 70 w/w % de isobutano (bons rendimentos de espumas, bem como menos cell collapse a -10/-10ºC) produziam as melhores espumas. Também foram desenvolvidos testes sobre a influência da quantidade de gás GLP presente numa lata. A análise do volume de GLP usado, foi realizada com base na melhor espuma obtida nos estudos anteriores, 7396, com um GLP (30 / 0/ 70 w/w%), e foram feitas alterações ao seu volume gás GLP presente no pré-polímero. O estudo concluiu, que o aumento do volume pode diminuir a densidade das espumas, e o seu decréscimo, um aumento da densidade. Também indico u que um mau ajuste do volume poderá causar más propriedades nas espumas. A análise económica, concluiu que o custo das espumas com mais GLP nas suas formulações, reduz-se em cerca de 3%, a quando de um aumento do volume de GLP no pré-polímero de cerca de 8 %. Esta diminuição de custos deveu-se ao facto, de um aumento de volume de gás, implicar uma diminuição na quantidade das restantes matérias-primas, com custos superiores, já que o volume útil total da lata terá de ser sempre mantido nos 750 mL. Com o objectivo de melhorar a qualidade da espuma 7396 (30/0/70 w/w %) obtida nos ensaios anteriores adicionou-se à formulação 7396 o HFC-152a (1,1-di fluoroetano). Os resultados demonstram que se formam espumas com más propriedades, especialmente a -10/-10ºC, contudo proporcionou excelentes shaking rate da lata. Através de uma pequena análise de custos não é aconselhável o seu uso pelos resultados obtidos, não proporcionando um balanço custo/benefício favorável. As três melhores espumas obtidas de todos os estudos foram comparadas com uma espuma de inverno presente no mercado. 7396 e 7638 com um volume de 27 % no prépolímero e uma composição de GLP (30/ 0 / 70 w/w%) e (13,7/ 0/ 86,3 w/w%), respectivamente, e 7690, com 37 % de volume no pré-polímero e GLP (30/ 0 / 70 w/w%), apresentaram em geral melhores resultados, comparando com a espuma benchmark . Contudo, os seus shaking rate a -10/-10ºC, de cada espuma, apresentaram valores bastante inferiores à composição benchmarking.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study explores a large set of OC and EC measurements in PM(10) and PM(2.5) aerosol samples, undertaken with a long term constant analytical methodology, to evaluate the capability of the OC/EC minimum ratio to represent the ratio between the OC and EC aerosol components resulting from fossil fuel combustion (OC(ff)/EC(ff)). The data set covers a wide geographical area in Europe, but with a particular focus upon Portugal, Spain and the United Kingdom, and includes a great variety of sites: urban (background, kerbside and tunnel), industrial, rural and remote. The highest minimum ratios were found in samples from remote and rural sites. Urban background sites have shown spatially and temporally consistent minimum ratios, of around 1.0 for PM(10) and 0.7 for PM(2.5).The consistency of results has suggested that the method could be used as a tool to derive the ratio between OC and EC from fossil fuel combustion and consequently to differentiate OC from primary and secondary sources. To explore this capability, OC and EC measurements were performed in a busy roadway tunnel in central Lisbon. The OC/EC ratio, which reflected the composition of vehicle combustion emissions, was in the range of 03-0.4. Ratios of OC/EC in roadside increment air (roadside minus urban background) in Birmingham, UK also lie within the range 03-0.4. Additional measurements were performed under heavy traffic conditions at two double kerbside sites located in the centre of Lisbon and Madrid. The OC/EC minimum ratios observed at both sites were found to be between those of the tunnel and those of urban background air, suggesting that minimum values commonly obtained for this parameter in open urban atmospheres over-predict the direct emissions of OC(ff) from road transport. Possible reasons for this discrepancy are explored. (C) 2011 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Protein-energy wasting (PEW), associated with inflammation and overhydration, is common in haemodialysis (HD) patients and is associated with high morbidity and mortality. Objective: Assess the relationship between nutritional status, markers of inflammation and body composition through bioimpedance spectroscopy (BIS) in HD patients. Methods: This observational, cross-sectional, single centre study, carried out in an HD centre in Forte da Casa (Portugal), involved 75 patients on an HD programme. In all participating patients, the following laboratory tests were conducted: haemoglobin, albumin, C-reactive protein (CRP) and 25-hydroxyvitamin D3 [25(OH)D3]. The body mass index of all patients was calculated and a modified version of subjective global assessment (SGA) was produced for patients on dialysis. Intracellular water (ICW) and extracellular water (ECW) were measured by BIS (Body Composition Monitor®, Fresenius Medical Care®) after the HD session. In statistical analysis, Spearman’s correlation was used for the univariate analysis and linear regression for the multivariate analysis (SPSS 14.0). A P value of <.05 was considered statistically significant. Results: PEW, inversely assessed through the ICW/body weight (BW) ratio, was positively related to age (P<.001), presence of diabetes (P=.004), BMI (P=.01) and CRP (P=.008) and negatively related to albumin (p=.006) and 25(OH)D3 (P=.007). Overhydration, assessed directly through the ECW/BW ratio, was positively related with CRP (P=.009) and SGA (P=.03), and negatively with 25(OH)D3 (P=.006) and BMI (P=.01). In multivariate analysis, PEW was associated with older age (P<.001), the presence of diabetes (P=.003), lower 25(OH)D3 (P=.008), higher CRP (P=.001) and lower albumin levels (P=.004). Over-hydration was associated with higher CRP (P=.001) and lower levels of 25(OH)D3 (P=.003). Conclusions: Taking these results into account, the ICW/BW and ECW/BW ratios, assessed with BIS, have proven to be good markers of the nutritional and inflammatory status of HD patients. BIS may be a useful tool for regularly assessing the nutritional and hydration status in these patients and may allow nutritional advice to be improved and adjusted.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The fatty acid profile of erythrocyte membranes has been considered a good biomarker for several pathologic situations. Dietary intake, digestion, absorption, metabolism, storage and exchange amongst compartments, greatly influence the fatty acids composition of different cells and tissues. Lipoprotein and hepatic lipases were also involved in fatty acid availability. In the present work we examined the correlations between fatty acid in Red Blood Cells (RBCs) membranes, the fatty acid desaturase and elongase activities, glycaemia, blood lipids, lipoproteins and apoproteins, and the endothelial lipase (EL) mass in plasma. Twenty one individuals were considered in the present study, with age >18 y. RBCs membranes were obtained and analysed for fatty acid composition by gas chromatography. The amount of fatty acids (as percentage) were analysed, and the ratios between fatty acid 16:1/16:0; 18:1/18:0; 18:0/16:0; 22:6 n-3/20:5 n-3 and 20:4 n-6/18:2 n-6 were calculated. Bivariate analysis (rs) and partial correlations were determined. SCD16 estimation activity correlated positively with BMI (rs=0.466, p=0.043) and triacylglycerols (TAG) (rs=0.483, p=0.026), and negatively with the ratio ApoA1/ApoB (rs=-0.566, p=0.007). Endothelial lipase (EL) correlated positively with the EPA/AA ratio in RBCs membranes (rs=0.524, p=0.045). After multi-adjustment for BMI, age, hs-CRP and dietary n3/n6 ratio, the correlations remained significant between EL and EPA/AA ratio. At the best of our knowledge this is the first report that correlated EL with the fatty acid profile of RBCs plasma membranes. The association found here can suggest that the enzyme may be involved in the bioavailability and distribution of n-3/n-6 fatty acids, suggesting a major role for EL in the pathophysiological mechanisms involving biomembranes’ fatty acids, such as in inflammatory response and eicosanoids metabolites pathways.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação elaborada no Laboratório Nacional de Engenharia Civil (LNEC) para obtenção do grau de Mestre em Engenharia Civil na Área de Especialização de Edificações no âmbito do protocolo de cooperação entre o ISEL e o LNEC

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mestrado em Contabilidade e Análise Financeira

Relevância:

20.00% 20.00%

Publicador:

Resumo:

There are several hazards in histopathology laboratories and its staff must ensure that their professional activity is set to the highest standards while complying with the best safety procedures. Formalin is one of the chemical hazards to which such professionals are routinely exposed. To decrease this contact, it is suggested that 10% neutral buffered liquid formalin (FL) is replaced by 10% formalin-gel (FG), given the later reduces the likelihood of spills and splashes, and decreased fume levels are released during its handling, proving itself less harmful. However, it is mandatory to assess the effectiveness of FG as a fixative and ensure that the subsequent complementary techniques, such as immunohistochemistry (IHC), are not compromised. Two groups of 30 samples from human placenta have been fixed with FG and FL fixatives during different periods of time (12, 24, and 48 hours) and, thereafter, processed, embedded, and sectioned. IHC for six different antibodies was performed and the results were scored (0–100) using an algorithm that took into account immunostaining intensity, percentage of staining structures, non-specific immunostaining, contrast, and morphological preservation. Parametric and non-parametric statistical tests were used (alpha = 0•05). All results were similar for both fixatives, with global score means of 95•36±6•65 for FL and 96•06±5•80 for FG, and without any statistical difference (P>0•05). The duration of the fixation had no statistical relevance also (P>0•05). So it is proved here FG could be an effective alternative to FL.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Independent component analysis (ICA) has recently been proposed as a tool to unmix hyperspectral data. ICA is founded on two assumptions: 1) the observed spectrum vector is a linear mixture of the constituent spectra (endmember spectra) weighted by the correspondent abundance fractions (sources); 2)sources are statistically independent. Independent factor analysis (IFA) extends ICA to linear mixtures of independent sources immersed in noise. Concerning hyperspectral data, the first assumption is valid whenever the multiple scattering among the distinct constituent substances (endmembers) is negligible, and the surface is partitioned according to the fractional abundances. The second assumption, however, is violated, since the sum of abundance fractions associated to each pixel is constant due to physical constraints in the data acquisition process. Thus, sources cannot be statistically independent, this compromising the performance of ICA/IFA algorithms in hyperspectral unmixing. This paper studies the impact of hyperspectral source statistical dependence on ICA and IFA performances. We conclude that the accuracy of these methods tends to improve with the increase of the signature variability, of the number of endmembers, and of the signal-to-noise ratio. In any case, there are always endmembers incorrectly unmixed. We arrive to this conclusion by minimizing the mutual information of simulated and real hyperspectral mixtures. The computation of mutual information is based on fitting mixtures of Gaussians to the observed data. A method to sort ICA and IFA estimates in terms of the likelihood of being correctly unmixed is proposed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objetivos – Demonstrar o potencial da espetroscopia (1H) por ressonância magnética na doença degenerativa discal lombar e defender a integração desta técnica na rotina clínico‑imagiológica para a precisa classificação da involução vs degenerescência dos discos L4‑L5 e L5‑S1 em doentes com lombalgia não relacionável com causa mecânica. Material e métodos – O estudo incluiu 102 discos intervertebrais lombares de 123 doentes. Foram estudados 61 discos de L4‑L5, 41 discos de L5‑S1 e 34 discos de D12‑L1. Utilizou‑se um sistema de ressonância magnética de 1,5 T e técnica monovoxel. Obtiveram‑se os rácios [Lac/Nacetyl] e [Nacetyl/(Lac+Lípidos)] e aplicou‑se a ressonância de lípidos para avaliar a bioquímica do disco com o fim de conhecer o estado de involução vs degenerescência que o suscetibilizam para a instabilidade e sobrecarga. Avaliou‑se o comportamento dos rácios e do teor lipídico dos discos L4‑L5‑S1 e as diferenças apresentadas em relação a D12‑L1. Foi também realizada a comparação entre os discos L4‑L5, L5‑S1 e D12‑L1 na ponderação T2 (T2W), segundo a classificação ajustada (1‑4) de Pfirrmann. Resultados – Verificou‑se que os rácios e o valor dos lípidos dos discos L4‑L5‑S1 apresentaram diferenças estatisticamente significativas quando relacionados com os discos D12‑L1. O rácio [Lac/Nacetyl] em L4‑L5‑S1 mostrou‑se aumentado em relação a D12‑L1 (p=0,033 para os discos com grau de involução [1+2] e p=0,004 para os discos com grau [3+4]). Estes resultados sugerem que a involução vs degenerescência dos discos nos graus mais elevados condiciona um decréscimo do pico do Lactato. O rácio [Nacetyl/(Lac+Lip)] discrimina os graus de involução [1+2] do [3+4] no nível L4‑L5, apresentando os valores dos rácios (média 0,65 e 0,5 respetivamente com p=0,04). O rácio médio de [Nacetyl/(Lac+Lip)] dos discos L4‑L5 foi 1,8 vezes mais elevado do que em D12‑L1. O espetro lipídico em L4‑L5‑S1 nos graus mais elevados não mostrou ter uma prevalência constante quanto às frequências de ressonância. Conclusão – A espetroscopia (1H) dos discos intervertebrais poderá ter aplicação na discriminação dos graus de involução vs degenerescência e representar um contributo semiológico importante em suplemento à ponderação T2 convencional. As ressonâncias de lípidos dos discos L4‑L5 e L5‑S1, involuídos ou degenerados, devem ser avaliadas em relação a D12‑L1, utilizando este valor como referência, pois este último é o nível considerado estável e com baixa probabilidade de degenerescência.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Trabalho Final de Mestrado para obtenção do grau de Mestre em Engenharia Química e Biológica