8 resultados para Intensity Difference Fluctuations

em Repositório Científico do Instituto Politécnico de Lisboa - Portugal


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Portugal is a culture grounded in strong traditions and family. Yet, social changes like women returning to the workforce and a decreas ed national birth rate are impacting the traditional family structure and care giving environments of children. Female employment has been increasing steadily in P ortugal over the last three decades (Galego & Pereira, 2006) and the total fert ility rate decreasing from 4.1 to 2.8 (INE, 2006). Furthermore, extended family me mbers, like grandparents, no longer reside close by to their children and grandc hildren as in the past, because of a changing labor market. Many of the younger gen eration are leaving their rural communities to flock to urban areas because o f job opportunities, leaving behind older relatives who would have otherwise par ticipated in the daily care of children. Given these social and economic changes, children are spending more time in out-of-home care with non-familial caregive rs. Yet, government regulations and guidelines in early care and educat ion (ECCE) and early intervention (EI) are only just emerging; it contin ues to be a work in progress.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: A common task in analyzing microarray data is to determine which genes are differentially expressed across two (or more) kind of tissue samples or samples submitted under experimental conditions. Several statistical methods have been proposed to accomplish this goal, generally based on measures of distance between classes. It is well known that biological samples are heterogeneous because of factors such as molecular subtypes or genetic background that are often unknown to the experimenter. For instance, in experiments which involve molecular classification of tumors it is important to identify significant subtypes of cancer. Bimodal or multimodal distributions often reflect the presence of subsamples mixtures. Consequently, there can be genes differentially expressed on sample subgroups which are missed if usual statistical approaches are used. In this paper we propose a new graphical tool which not only identifies genes with up and down regulations, but also genes with differential expression in different subclasses, that are usually missed if current statistical methods are used. This tool is based on two measures of distance between samples, namely the overlapping coefficient (OVL) between two densities and the area under the receiver operating characteristic (ROC) curve. The methodology proposed here was implemented in the open-source R software. Results: This method was applied to a publicly available dataset, as well as to a simulated dataset. We compared our results with the ones obtained using some of the standard methods for detecting differentially expressed genes, namely Welch t-statistic, fold change (FC), rank products (RP), average difference (AD), weighted average difference (WAD), moderated t-statistic (modT), intensity-based moderated t-statistic (ibmT), significance analysis of microarrays (samT) and area under the ROC curve (AUC). On both datasets all differentially expressed genes with bimodal or multimodal distributions were not selected by all standard selection procedures. We also compared our results with (i) area between ROC curve and rising area (ABCR) and (ii) the test for not proper ROC curves (TNRC). We found our methodology more comprehensive, because it detects both bimodal and multimodal distributions and different variances can be considered on both samples. Another advantage of our method is that we can analyze graphically the behavior of different kinds of differentially expressed genes. Conclusion: Our results indicate that the arrow plot represents a new flexible and useful tool for the analysis of gene expression profiles from microarrays.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mestrado em Radiações Aplicadas às Tecnologias da Saúde.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A glomerulonefrite membranosa faz parte das doenças glomerulares que provocam glomerulonefrite crônica, apresentando-se como uma das causas da doença renal terminal. As técnicas de imunofluorescência são o gold standard no estudo imunológico desta patologia em biópsia renal, através da deteção de imunocomplexos (e.g. IgG e C3) e do seu padrão de distribuição granular característico. No entanto, a imunofluorescência não permite uma contextualização histológica e os fluorocromos utilizados possuem um reduzido tempo de atividade, ao contrário das técnicas imunoenzimáticas que utilizam cromogénios coloridos precipitados que permitem a obtenção de uma marcação permanente e a sua contextualização histológica por via da utilização de eficientes colorações de contraste. Com a finalidade de contribuir para a qualidade do diagnóstico da glomerulonefrite membranosa, em biópsias renais, procurou-se, com esta pesquisa, identificar uma técnica imunoenzimática, através da conjugação entre diferentes cromogênios e colorações de contraste, que permita a deteção de depósitos de IgG e C3, com padrão granular. Foram constituídos diferentes binômios cromogênio + coloração, com os cromogênios 3,3›- Diaminobenzidine Tetrahydrochloride e 3-Amino-9-ethylcarbazole e as colorações Periodic Acid Schiff, Periodic Acid Methenamine Silver e Hematoxilina. Foram utilizadas 72 secções de tecido provenientes de seis de casos de biópsias renais com diagnóstico de glomerulonefrite membranosa, fixados em formalina a 10% e incluídos em parafina. A recolha de dados foi realizada por observação microscópica com preenchimento de uma grelha de classificação dos parâmetros: preservação da morfologia, intensidade da marcação específica, quantidade relativa de estruturas marcadas, marcação inespecífica/fundo, contraste e padrão da marcação, que permitiu a classificação dos binómios estudados num score quantitativo de 0-100 pontos. O binômio que apresentou melhores resultados foi 3-Amino-9-ethylcarbazole + Hematoxilina (score 71,81) e o binômio 3,3›- Diaminobenzidine Tetrahydrochloride+Periodic Acid Methenamine Silver (score 7,81), apresentou os piores resultados. O resultado do teste Kruskal-Wallis indica-nos a presença de diferenças estatísticas entre os binómios em estudo (p=0,000). A Hematoxilina pode ser considerada a coloração mais eficaz, pois cumpriu a sua função de auxiliar e facilitar a observação do tipo de padrão com os dois cromogênios utilizados. O cromogênio 3-Amino-9-ethylcarbazole apresentou resultados semelhantes aos produzidos pelo 3,3›-Diaminobenzidine Tetrahydrochloride, no entanto, permitiu identificar em todos os casos o padrão granular de imunomarcação, ao contrário do que aconteceu com este último.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Monte Carlo (MC) dose calculation algorithms have been widely used to verify the accuracy of intensity-modulated radiotherapy (IMRT) dose distributions computed by conventional algorithms due to the ability to precisely account for the effects of tissue inhomogeneities and multileaf collimator characteristics. Both algorithms present, however, a particular difference in terms of dose calculation and report. Whereas dose from conventional methods is traditionally computed and reported as the water-equivalent dose (Dw), MC dose algorithms calculate and report dose to medium (Dm). In order to compare consistently both methods, the conversion of MC Dm into Dw is therefore necessary. This study aims to assess the effect of applying the conversion of MC-based Dm distributions to Dw for prostate IMRT plans generated for 6 MV photon beams. MC phantoms were created from the patient CT images using three different ramps to convert CT numbers into material and mass density: a conventional four material ramp (CTCREATE) and two simplified CT conversion ramps: (1) air and water with variable densities and (2) air and water with unit density. MC simulations were performed using the BEAMnrc code for the treatment head simulation and the DOSXYZnrc code for the patient dose calculation. The conversion of Dm to Dw by scaling with the stopping power ratios of water to medium was also performed in a post-MC calculation process. The comparison of MC dose distributions calculated in conventional and simplified (water with variable densities) phantoms showed that the effect of material composition on dose-volume histograms (DVH) was less than 1% for soft tissue and about 2.5% near and inside bone structures. The effect of material density on DVH was less than 1% for all tissues through the comparison of MC distributions performed in the two simplified phantoms considering water. Additionally, MC dose distributions were compared with the predictions from an Eclipse treatment planning system (TPS), which employed a pencil beam convolution (PBC) algorithm with Modified Batho Power Law heterogeneity correction. Eclipse PBC and MC calculations (conventional and simplified phantoms) agreed well (<1%) for soft tissues. For femoral heads, differences up to 3% were observed between the DVH for Eclipse PBC and MC calculated in conventional phantoms. The use of the CT conversion ramp of water with variable densities for MC simulations showed no dose discrepancies (0.5%) with the PBC algorithm. Moreover, converting Dm to Dw using mass stopping power ratios resulted in a significant shift (up to 6%) in the DVH for the femoral heads compared to the Eclipse PBC one. Our results show that, for prostate IMRT plans delivered with 6 MV photon beams, no conversion of MC dose from medium to water using stopping power ratio is needed. In contrast, MC dose calculations using water with variable density may be a simple way to solve the problem found using the dose conversion method based on the stopping power ratio.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

There are several hazards in histopathology laboratories and its staff must ensure that their professional activity is set to the highest standards while complying with the best safety procedures. Formalin is one of the chemical hazards to which such professionals are routinely exposed. To decrease this contact, it is suggested that 10% neutral buffered liquid formalin (FL) is replaced by 10% formalin-gel (FG), given the later reduces the likelihood of spills and splashes, and decreased fume levels are released during its handling, proving itself less harmful. However, it is mandatory to assess the effectiveness of FG as a fixative and ensure that the subsequent complementary techniques, such as immunohistochemistry (IHC), are not compromised. Two groups of 30 samples from human placenta have been fixed with FG and FL fixatives during different periods of time (12, 24, and 48 hours) and, thereafter, processed, embedded, and sectioned. IHC for six different antibodies was performed and the results were scored (0–100) using an algorithm that took into account immunostaining intensity, percentage of staining structures, non-specific immunostaining, contrast, and morphological preservation. Parametric and non-parametric statistical tests were used (alpha = 0•05). All results were similar for both fixatives, with global score means of 95•36±6•65 for FL and 96•06±5•80 for FG, and without any statistical difference (P>0•05). The duration of the fixation had no statistical relevance also (P>0•05). So it is proved here FG could be an effective alternative to FL.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Desde o início da utilização da imunohistoquímica em anatomia patológica, um dos objetivos tem sido detetar as quantidades mais ínfimas de antigénio, tornando-o visível ao microscópio ótico. Vários sistemas de amplificação têm sido aplicados de forma a concretizar este objetivo, tendo surgido um grupo genérico de métodos simples e que apresentam uma amplificação superior: são os denominados métodos do polímero indireto. Tendo em conta a variedade de métodos disponíveis, o autor propõe-se a comparar a qualidade de quatro sistemas de amplificação, que recorrem ao método do polímero indireto com horseradish peroxidase (HRP). Foram utilizadas lâminas de diferentes tecidos, fixados em formol e incluídos em parafina, nos quais se procedeu à identificação de 15 antigénios distintos. Na amplificação recorreu-se a quatro sistemas de polímero indireto (Dako EnVision+ System – K4006; LabVision UltraVision LP Detection System – TL-004-HD; Leica NovoLink – RE7140-k; Vector ImmPRESS Reagent Kit – MP-7402). A observação microscópica e classificação da imunomarcação obtida foram feitas com base num algoritmo que enquadra intensidade, marcação específica, marcação inespecífica e contraste, num score global que pode tomar valores entre 0 e 25. No tratamento dos dados, para além da estatística descritiva, foi utilizado o teste one-way ANOVA com posthoc de tukey (alfa=0.05). O melhor resultado obtido, em termos de par média/desvio-padrão, dos scores globais foi o do NovoLink (22,4/2,37) e o pior foi o do EnVision+ (17,43/3,86). Verificou-se ainda que existe diferença estatística entre os resultados obtidos pelo sistema NovoLink e os sistemas UltraVision (p=.004), ImmPRESS (p=.000) e EnVision+ (p=.000). Concluiu-se que o sistema que permitiu a obtenção de melhores resultados, neste estudo, foi o Leica NovoLink.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Trabalho Final de Mestrado para a obtenção do grau de Mestre em Engenharia Mecânica /Energia