23 resultados para IRREGULAR GALAXY IC-10

em Repositório Científico do Instituto Politécnico de Lisboa - Portugal


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Actualmente, é notável um interesse crescente relativamente ao estudo de insectos: interesses agrícolas (controlo de pragas) e interesses forenses (entomologia forense). A análise histológica destes organismos visa completar os conhecimentos já adquiridos. Objectivos gerais: obter lâminas histológicas de insectos. Objectivos específicos: determinar qual o fixador mais adequado, centrando as opções no Formol Tamponado a 10% (FT), Líquido de Bouin (LB) e Bouin Holland (BH); verificar se o processamento histológico de rotina se aplica ao estudo de insectos.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Lisbon is the largest urban area in the Western European coast. Due to this geographical position the Atlantic Ocean serves as an important source of particles and plays an important role in many atmospheric processes. The main objectives of this study were to (1) perform a chemical characterization of particulate matter (PM2.5) sampled in Lisbon, (2) identify the main sources of particles, (3) determine PM contribution to this urban area, and (4) assess the impact of maritime air mass trajectories on concentration and composition of respirable PM sampled in Lisbon. During 2007, PM2.5 was collected on a daily basis in the center of Lisbon with a Partisol sampler. The exposed Teflon filters were measured by gravimetry and cut into two parts: one for analysis by instrumental neutron activation analysis (INAA) and the other by ion chromatography (IC). Principal component analysis (PCA) and multilinear regression analysis (MLRA) were used to identify possible sources of PM2.5 and determine mass contribution. Five main groups of sources were identified: secondary aerosols, traffic, calcium, soil, and sea. Four-day backtracking trajectories ending in Lisbon at the starting sampling time were calculated using the HYSPLIT model. Results showed that maritime transport scenarios were frequent. These episodes were characterized by a significant decrease of anthropogenic aerosol concentrations and exerted a significant role on air quality in this urban area.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

RESUMO: Introdução – A insuficiência de convergência (IC) pode desencadear alterações da atenção visual. Pretende-se investigar se existem alterações na atenção visual em estudantes do ensino superior com IC. Metodologia – Estudo quantitativo, comparativo e correlacional. Participaram 44 estudantes com idades compreendidas entre os 18 e os 24 anos. Formaram-se dois grupos, um com Visão Binocular Normal (VBN) e outro com IC. O grupo com IC incluiu os indivíduos que apresentaram alterações no ponto próximo de convergência (PPC) e/ou na convergência para perto (C’). Para avaliar a atenção visual utilizou-se o teste de cancelamento de sinos. Resultados – O grupo com VBN foi composto por 32 indivíduos (23 do género feminino) e o grupo com IC por 12 indivíduos (11 do género feminino). No teste de atenção visual verificou-se que o número médio de sinos identificados foi de 34,6 para o grupo com VBN e de 34,3 no grupo com IC. O tempo médio de realização do teste foi de 167,9s e de 198,3s para os grupos de VBN e IC, respetivamente. Observou-se uma correlação moderada positiva entre o PPC e o tempo médio de realização do teste (r≈0,63) e uma correlação fraca positiva entre o número médio de sinos identificados e a C’ (r≈0,16). Por outro lado, a correlação entre o PPC e o número médio de sinos identificados (r≈-0,48) foi fraca negativa e entre a C’ e o tempo médio (r≈-0,05) foi ínfima negativa. Discussão/Conclusões – O grupo com VBN apresenta um número médio de sinos identificados superior ao grupo com IC. Verifica-se ainda que o grupo com IC demorou mais tempo na realização do teste, comparativamente com o grupo com VBN. Estes resultados apontam para uma possível relação entre a IC e a diminuição da atenção visual.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A presente dissertação tem como objetivo efetuar a análise comparativa de soluções adotadas de reabilitação de pavimentos flexíveis que integram a rede rodoviária nacional. No âmbito desta análise apresenta-se o estado da arte respeitante à reabilitação de pavimentos flexíveis, nomeadamente: mecanismos de degradação, famílias de degradações, avaliação da capacidade de carga dos pavimentos, metodologia utilizada no dimensionamento do reforço de pavimentos, sendo também efetuada uma análise comparativa de técnicas de reforço de pavimentos e dos tratamentos antifendas. Neste contexto, apresenta-se um caso de estudo no qual é efetuada uma análise de três soluções possíveis para a reabilitação estrutural do pavimento do IC 20 entre Almada e a Costa de Caparica. É feita a descrição da solução projetada pela EP, SA patenteada em concurso público lançado em 2007, a qual é de certa forma inovadora ao nível do tratamento retardador da reflexão de fendas. Aquela solução técnica é constituída pela aplicação de grelhas de fibra de vidro e grelhas de fibra de carbono, seguidas da colocação de uma camada de desgaste em mistura betuminosa rugosa com betume modificado com baixa percentagem de borracha reciclada de pneus usados (BBr - BBB). Complementarmente, é efetuada a análise da solução do projeto de reabilitação do IC 20, patenteado pela Subconcessionária do Baixo Tejo, que contemplou a aplicação de misturas betuminosas rugosas com betume modificado com média percentagem de borracha reciclada de pneus usados (BBr - BBM). Para além da solução patenteada pela subconcessionária, é analisada a solução do projeto de alterações (variante) apresentado pelo agrupamento de empresas construtoras, que foi adotado na execução da obra realizada no IC 20. A intervenção de reabilitação estrutural contemplou a utilização de uma camada de ligação em AC 16 10/20 (MBAM) e uma camada de desgaste em mistura betuminosa rugosa com betume modificado com média percentagem de borracha reciclada de pneus usados (BBr - BBM). Adicionalmente à caracterização de diferentes soluções de reabilitação de pavimentos flexíveis adotados em Portugal, é efetuada uma análise comparativa dos custos de ciclo de vida (construção, manutenção e conservação) de cada tipo de solução de reabilitação.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The compounds [mPTA][CoCl4] (1, mPTA = N-methyl-1,3,5-triaza-7-phosphaadamantane cation), [CoCl(H2O)(DION)(2)][BF4] (2, DION = 1,10-phenanthroline-5,6-dione), [Zn(DION)(2)]Cl-2 (3) and [ZnCl(O-PTA=O)(DION)][BF4] (4) were synthesized by reaction of CoCl2 with [mPTA]I or DION and ZnCl2 with DION or 1,3,5-triaza-7-phosphaadamantane-7-oxide (PTA=O) and DION, respectively. All complexes are water soluble and have been characterized by IR, far-IR, H-1, C-13 and P-31{H-1} NMR spectroscopy, ESI-MS, elemental analyses and single-crystal X-ray diffraction structural analysis (for 1). They were screened against the human tumour cell lines HCT116, HepG2 and MCF7. Complexes 2 and 3 exhibit the highest in vitro cytotoxicity and show lower cytotoxic activities in normal human fibroblast cell line than in HCT116 tumour cell line, which demonstrates their slight specificity for this type of tumour cell.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Polymorphisms located in genes involved in the metabolism of folate and some methyl-related nutrients are implicated in colorectal cancer (CRC). Objective: We evaluated the association of 3 genetic polymorphisms [C677T MTHFR (methylene tetrahydrofolate reductase), A2756G MTR (methionine synthase), and C1420T SHMT (serine hydroxymethyltransferase)] with the intake of methyl-donor nutrients in CRC risk. Design: Patients withCRC(n 196) and healthy controls (n 200) matched for age and sex were evaluated for intake of methyl-donor nutrients and the 3 polymorphisms. Results: Except for folate intake, which was significantly lower in patients (P 0.02), no differences were observed in the dietary intake of other methyl-donor nutrients between groups. High intake of folate ( 406.7 g/d) was associated with a significantly lower risk of CRC (odds ratio: 0.67; 95% CI: 0.45, 0.99). The A2756G MTR polymorphism was not associated with the risk of developing CRC. In contrast, homozygosity for the C677TMTHFRvariant (TT) presented a 3.0-fold increased risk of CRC (95% CI: 1.3, 6.7). Similarly, homozygosity for the C1420T SHMT polymorphism also had a 2.6-fold increased risk (95% CI: 1.1, 5.9) of developing CRC. When interactions between variables were studied, low intake of all methyl-donor nutrients was associated with an increased risk ofCRC in homozygous participants for the C677T MTHFR polymorphism, but a statistically significant interaction was only observed for folate (odds ratio: 14.0; 95% CI: 1.8, 108.5). No significant associations were seen for MTR or SHMT polymorphisms. Conclusion: These results show an association between the C677T MTHFR variant and different folate intakes on risk of CRC.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Trabalho Final de Mestrado para obtenção do grau de Mestre em Engenharia Electrónica e Telecomunicações

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose - This study aims to investigate the influence of tube potential (kVp) variation in relation to perceptual image quality and effective dose (E) for pelvis using automatic exposure control (AEC) and non-AEC in a Computed Radiography (CR) system. Methods and materials - To determine the effects of using AEC and non-AEC by applying the 10 kVp rule in two experiments using an anthropomorphic pelvis phantom. Images were acquired using 10 kVp increments (60–120 kVp) for both experiments. The first experiment, based on seven AEC combinations, produced 49 images. The mean mAs from each kVp increment were used as a baseline for the second experiment producing 35 images. A total of 84 images were produced and a panel of 5 experienced observers participated for the image scoring using the two alternative forced choice (2AFC) visual grading software. PCXMC software was used to estimate E. Results - A decrease in perceptual image quality as the kVp increases was observed both in non-AEC and AEC experiments, however no significant statistical differences (p > 0.05) were found. Image quality scores from all observers at 10 kVp increments for all mAs values using non-AEC mode demonstrates a better score up to 90 kVp. E results show a statistically significant decrease (p = 0.000) on the 75th quartile from 0.37 mSv at 60 kVp to 0.13 mSv at 120 kVp when applying the 10 kVp rule in non-AEC mode. Conclusion - Using the 10 kVp rule, no significant reduction in perceptual image quality is observed when increasing kVp whilst a marked and significant E reduction is observed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose - To compare the image quality and effective dose applying the 10 kVp rule with manual mode acquisition and AEC mode in PA chest X-ray. Method - 68 images (with and without lesions) were acquired using an anthropomorphic chest phantom using a Wolverson Arcoma X-ray unit. These images were compared against a reference image using the 2 alternative forced choice (2AFC) method. The effective dose (E) was calculated using PCXMC software using the exposure parameters and the DAP. The exposure index (lgM provided by Agfa systems) was recorded. Results - Exposure time decreases more when applying the 10 kVp rule with manual mode (50%–28%) when compared with automatic mode (36%–23%). Statistical differences for E between several ionization chambers' combinations for AEC mode were found (p = 0.002). E is lower when using only the right AEC ionization chamber. Considering the image quality there are no statistical differences (p = 0.348) between the different ionization chambers' combinations for AEC mode for images with no lesions. Considering lgM values, it was demonstrated that they were higher when the AEC mode was used compared to the manual mode. It was also observed that lgM values obtained with AEC mode increased as kVp value went up. The image quality scores did not demonstrate statistical significant differences (p = 0.343) for the images with lesions comparing manual with AEC mode. Conclusion - In general the E is lower when manual mode is used. By using the right AEC ionising chamber under the lung the E will be the lowest in comparison to other ionising chambers. The use of the 10 kVp rule did not affect the visibility of the lesions or image quality.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background - Pelvis and hip radiography are consistently found to be amongst the highest contributors to the collective effective dose (E) in all ten DOSE DATAMED countries in Europe, representing 2.8 to 9.4% of total collective dose (S) in the TOP 20 exams list. The level of image quality should provide all the diagnostic information in order not to jeopardise the diagnosis, but being able to provide the needed clinical information with the minimum dose. A recent study suggests further research to determine whether the “10 kVp rule” would have value for a range of examinations using Computed Radiography (CR) systems. As a “rule of thumb” increasing the kVp by 10 whilst halving the mAs is suggested to give a similar perceptual image quality when compared to the original exposure factors. Aims - In light of the 10kVp rule, this study aims to investigate the influence of tube potential (kVp) variation in relation to perceptual image quality and E for pelvis imaging using automatic exposure control (AEC) and non-AEC in a Computed Radiography (CR) system. Research questions - Does the 10kVp rule works for the pelvis in relation to image quality in a CR system? Does the image quality differs when the AEC is used instead of manual mode using the 10kVp rule and how this impacts on E?

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Trabalho de Projecto para obtenção do grau de Mestre em Engenharia Civil

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mestrado em Tecnologia de Diagnóstico e Intervenção Cardiovascular - Ramo de especialização: Ultrassonografia Cardiovascular

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To compare image quality and effective dose when the 10 kVp rule is applied with manual and AEC mode in PA chest X-ray. Methods and Materials: A total of 68 images (with and without lesions) were acquired of an anthropomorphic chest phantom in a Wolverson Arcoma X-ray unit. The images were evaluated against a reference image using image quality criteria and the 2 alternative forced choice (2 AFC) method by five radiographers. The effective dose was calculated using PCXMC software using the exposure parameters and DAP. The exposure index (lgM) was recorded. Results: Exposure time decreases considerably when applying the 10 kVp rule in manual mode (50%-28%) compared to AEC mode (36%-23%). Statistical differences for effective dose between several AEC modes were found (p=0.002). The effective dose is lower when using only the right AEC ionization chamber. Considering image quality, there are no statistical differences (p=0.348) between the different AEC modes for images with no lesions. Using a higher kVp value the lgM values will also increase. The lgM values showed significant statistical differences (p=0.000). The image quality scores did not present statistically significant differences (p=0.043) for the images with lesions when comparing manual with AEC modes. Conclusion: In general, the dose is lower in the manual mode. By using the right AEC ionising chamber the effective dose will be the lowest in comparison to other ionising chambers. The use of the 10 kVp rule did not affect the detectability of the lesions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Floating-point computing with more than one TFLOP of peak performance is already a reality in recent Field-Programmable Gate Arrays (FPGA). General-Purpose Graphics Processing Units (GPGPU) and recent many-core CPUs have also taken advantage of the recent technological innovations in integrated circuit (IC) design and had also dramatically improved their peak performances. In this paper, we compare the trends of these computing architectures for high-performance computing and survey these platforms in the execution of algorithms belonging to different scientific application domains. Trends in peak performance, power consumption and sustained performances, for particular applications, show that FPGAs are increasing the gap to GPUs and many-core CPUs moving them away from high-performance computing with intensive floating-point calculations. FPGAs become competitive for custom floating-point or fixed-point representations, for smaller input sizes of certain algorithms, for combinational logic problems and parallel map-reduce problems. © 2014 Technical University of Munich (TUM).