6 resultados para IMMUNOHISTOCHEMISTRY

em Repositório Científico do Instituto Politécnico de Lisboa - Portugal


Relevância:

20.00% 20.00%

Publicador:

Resumo:

There are several hazards in histopathology laboratories and its staff must ensure that their professional activity is set to the highest standards while complying with the best safety procedures. Formalin is one of the chemical hazards to which such professionals are routinely exposed. To decrease this contact, it is suggested that 10% neutral buffered liquid formalin (FL) is replaced by 10% formalin-gel (FG), given the later reduces the likelihood of spills and splashes, and decreased fume levels are released during its handling, proving itself less harmful. However, it is mandatory to assess the effectiveness of FG as a fixative and ensure that the subsequent complementary techniques, such as immunohistochemistry (IHC), are not compromised. Two groups of 30 samples from human placenta have been fixed with FG and FL fixatives during different periods of time (12, 24, and 48 hours) and, thereafter, processed, embedded, and sectioned. IHC for six different antibodies was performed and the results were scored (0–100) using an algorithm that took into account immunostaining intensity, percentage of staining structures, non-specific immunostaining, contrast, and morphological preservation. Parametric and non-parametric statistical tests were used (alpha = 0•05). All results were similar for both fixatives, with global score means of 95•36±6•65 for FL and 96•06±5•80 for FG, and without any statistical difference (P>0•05). The duration of the fixation had no statistical relevance also (P>0•05). So it is proved here FG could be an effective alternative to FL.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Immunohistochemistry (IHC) is the group of techniques that use antibodies as specific reagents to identify and demonstrate several cell and tissue components that are antigens. This linking allows locating and identifying the in situ presence of various substances by means of color that is associated with the formed antigen-antibody complexes. The practical value of this biotechnology area, widely used in Pathology and Oncology, in diagnostic, prognostic, theranostic and research context, results from the possibility of combining a colour marker with an antibody without causing any damage to specific binding established between antibody and antigen. This provides the microscopic observation of the target locations where the antibody and hence the antigen are present. IHC is presented as a powerful means for identification of several cellular and tissue structures that can be associated with pathologies, and of the consequences, at functional and morphological level, of these same elements action.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Quando aplicada no âmbito da Anatomia Patológica, a imuno-histoquímica tem constituído um poderoso meio de identificação/caracterização de várias estruturas histológicas, permitindo delinear prognóstico e terapêutica para várias patologias. Tendo em conta que as amostras histológicas analisadas podem ser conservadas ao longo de vários anos, interessa avaliar a manutenção da antigenicidade ao longo do tempo, de forma a garantir a qualidade final da técnica quando aplicada em material de arquivo. Assim, o principal objetivo deste trabalho foi comparar a imunorreatividade do material histológico arquivado durante um, quatro e sete anos. Foi utilizado material histológico de próstata, pulmão e mama, no qual se procedeu à imunomarcação de citoqueratinas (Clones AE1/AE3), CD34 e proteína p63, por método de multímero/HRP no sistema Ventana BenchMark Ultra®. Foi realizado um ensaio com recuperação antigênica por alta temperatura (RAAT) e outro sem esta etapa. As imunomarcações (n=162) foram classificadas por três avaliadores independentes num escore quantitativo final (escala 0-100). O par média/desvio-padrão do escore final para os casos com sete anos foi de 69,06/19,05, para os casos com quatro anos foi de 66,47/20,73 e para os casos com um ano foi de 69,08/19,35, não se tendo encontrado diferenças estatisticamente significativas. Os casos sem RAAT obtiveram um par média/desvio-padrão de 54,90/17,00, enquanto os casos com RAAT obtiveram 81,50/11,60, o que revelou diferenças estatisticamente significativas (p=0,000). Para os casos em estudo conclui-se que o fator “tempo de arquivo” não está associado a alterações da imunorreatividade. A importância da RAAT na obtenção de imunomarcação de qualidade sai fortemente realçada. ABSTRACT - When applied within the framework of Pathology, immunohistochemistry has been a powerful means of identification/characterization of various histological structures, allowing to outline prognosis and therapy for various diseases. Given that the analyzed histological samples can be preserved for several years, it is interesting to assess the retention of antigenicity over time in order to ensure the quality of the final technique, when applied to stored material. Thus, the main objective of this study was to compare the immunoreactivity of the histological material archived for one, four and seven years. It was used histological material from prostate, lung and breast, in which it was performed the immunostaining of cytokeratins (clones AE1/AE3), CD34 and p63 protein by the method of multimer/HRP system on a Ventana BenchMark Ultra®. It was conducted a test with heat induced epitope retrieval (HIER) and another one without this step. The stained slides (n=162) were classified by three independent assessors using a quantitative score (scale 0-100). The pair mean/standard deviation of the score for cases with seven years was 69,06/19,05, for cases with four years was 66,47/20,73 and for cases with one year was 69,08/19,35, which did not revealed any statistically significant differences. The cases without HIER had a couple mean/standard deviation of 54.90/17.00 while the cases with HIER obtained 81.50/11.60, which revealed statistically significant differences (p=0.000). For this case study it was concluded that the factor archive period is not associated with changes in immunoreactivity. The importance of HIER in obtaining high quality immunostaining comes out strongly highlighted.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: To evaluate the influence of Everolimus (RAD001) on chemically induced urothelial lesions in mice and its influence on in vitro human bladder cancer cell lines. Methods: ICR male mice were given N-butyl-N-(4-hydroxybutyl) nitrosamine in drinking water for a period of 12 weeks. Subsequently, RAD001 was administered via oral gavage, for 6 weeks. At the end of the experiment, all the animals were sacrificed and tumor development was determined by means of histopathologic evaluation; mammalian target of rapamycin (mTOR) expressivity was evaluated by immunohistochemistry. Three human bladder cancer cell lines (T24, HT1376, and 5637) were treated using a range of RAD001 concentrations. MTT assay, terminal deoxynucleotidyl transferase dUTP nick end labeling (TUNEL), and flow cytometry were used to assess cell proliferation, apoptosis index, and cell cycle analysis, respectively. Immunoblotting analysis of 3 cell line extracts using mTOR and Akt antibodies was performed in order to study the expression of Akt and mTOR proteins and their phosphorylated forms. Results: The incidence of urothelial lesions in animals treated with RAD001 was similar to those animals not treated. RAD001 did not block T24 and HT1376 cell proliferation or induce apoptosis. A reduction in cell proliferation rate and therefore G0/G1 phase arrest, as well as a statistically significant induction of apoptosis (P 0.001), was only observed in the 5637 cell line. Conclusion: RAD001 seems not to have a significant effect on chemically induced murine bladder tumors. The effect of RAD001 on tumor proliferation and apoptosis was achieved only in superficial derived bladder cancer cell line, no effect was observed in invasive cell lines.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A glomerulonefrite membranosa faz parte das doenças glomerulares que provocam glomerulonefrite crônica, apresentando-se como uma das causas da doença renal terminal. As técnicas de imunofluorescência são o gold standard no estudo imunológico desta patologia em biópsia renal, através da deteção de imunocomplexos (e.g. IgG e C3) e do seu padrão de distribuição granular característico. No entanto, a imunofluorescência não permite uma contextualização histológica e os fluorocromos utilizados possuem um reduzido tempo de atividade, ao contrário das técnicas imunoenzimáticas que utilizam cromogénios coloridos precipitados que permitem a obtenção de uma marcação permanente e a sua contextualização histológica por via da utilização de eficientes colorações de contraste. Com a finalidade de contribuir para a qualidade do diagnóstico da glomerulonefrite membranosa, em biópsias renais, procurou-se, com esta pesquisa, identificar uma técnica imunoenzimática, através da conjugação entre diferentes cromogênios e colorações de contraste, que permita a deteção de depósitos de IgG e C3, com padrão granular. Foram constituídos diferentes binômios cromogênio + coloração, com os cromogênios 3,3›- Diaminobenzidine Tetrahydrochloride e 3-Amino-9-ethylcarbazole e as colorações Periodic Acid Schiff, Periodic Acid Methenamine Silver e Hematoxilina. Foram utilizadas 72 secções de tecido provenientes de seis de casos de biópsias renais com diagnóstico de glomerulonefrite membranosa, fixados em formalina a 10% e incluídos em parafina. A recolha de dados foi realizada por observação microscópica com preenchimento de uma grelha de classificação dos parâmetros: preservação da morfologia, intensidade da marcação específica, quantidade relativa de estruturas marcadas, marcação inespecífica/fundo, contraste e padrão da marcação, que permitiu a classificação dos binómios estudados num score quantitativo de 0-100 pontos. O binômio que apresentou melhores resultados foi 3-Amino-9-ethylcarbazole + Hematoxilina (score 71,81) e o binômio 3,3›- Diaminobenzidine Tetrahydrochloride+Periodic Acid Methenamine Silver (score 7,81), apresentou os piores resultados. O resultado do teste Kruskal-Wallis indica-nos a presença de diferenças estatísticas entre os binómios em estudo (p=0,000). A Hematoxilina pode ser considerada a coloração mais eficaz, pois cumpriu a sua função de auxiliar e facilitar a observação do tipo de padrão com os dois cromogênios utilizados. O cromogênio 3-Amino-9-ethylcarbazole apresentou resultados semelhantes aos produzidos pelo 3,3›-Diaminobenzidine Tetrahydrochloride, no entanto, permitiu identificar em todos os casos o padrão granular de imunomarcação, ao contrário do que aconteceu com este último.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Desde o início da utilização da imunohistoquímica em anatomia patológica, um dos objetivos tem sido detetar as quantidades mais ínfimas de antigénio, tornando-o visível ao microscópio ótico. Vários sistemas de amplificação têm sido aplicados de forma a concretizar este objetivo, tendo surgido um grupo genérico de métodos simples e que apresentam uma amplificação superior: são os denominados métodos do polímero indireto. Tendo em conta a variedade de métodos disponíveis, o autor propõe-se a comparar a qualidade de quatro sistemas de amplificação, que recorrem ao método do polímero indireto com horseradish peroxidase (HRP). Foram utilizadas lâminas de diferentes tecidos, fixados em formol e incluídos em parafina, nos quais se procedeu à identificação de 15 antigénios distintos. Na amplificação recorreu-se a quatro sistemas de polímero indireto (Dako EnVision+ System – K4006; LabVision UltraVision LP Detection System – TL-004-HD; Leica NovoLink – RE7140-k; Vector ImmPRESS Reagent Kit – MP-7402). A observação microscópica e classificação da imunomarcação obtida foram feitas com base num algoritmo que enquadra intensidade, marcação específica, marcação inespecífica e contraste, num score global que pode tomar valores entre 0 e 25. No tratamento dos dados, para além da estatística descritiva, foi utilizado o teste one-way ANOVA com posthoc de tukey (alfa=0.05). O melhor resultado obtido, em termos de par média/desvio-padrão, dos scores globais foi o do NovoLink (22,4/2,37) e o pior foi o do EnVision+ (17,43/3,86). Verificou-se ainda que existe diferença estatística entre os resultados obtidos pelo sistema NovoLink e os sistemas UltraVision (p=.004), ImmPRESS (p=.000) e EnVision+ (p=.000). Concluiu-se que o sistema que permitiu a obtenção de melhores resultados, neste estudo, foi o Leica NovoLink.