22 resultados para High-speed digital imaging

em Repositório Científico do Instituto Politécnico de Lisboa - Portugal


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Advances in digital technology led to the development of digital x-ray detectors that are currently in wide use for projection radiography, including Computed Radiography (CR) and Digital Radiography (DR). Digital Imaging Systems for Plain Radiography addresses the current technological methods available to medical imaging professionals to ensure the optimization of the radiological process concerning image quality and reduction of patient exposure. Based on extensive research by the authors and reference to the current literature, the book addresses how exposure parameters influence the diagnostic quality in digital systems, what the current acceptable radiation doses are for useful diagnostic images, and at what level the dose could be reduced to maintain an accurate diagnosis. The book is a valuable resource for both students learning the field and for imaging professionals to apply to their own practice while performing radiological examinations with digital systems.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The top velocity of high-speed trains is generally limited by the ability to supply the proper amount of energy through the pantograph-catenary interface. The deterioration of this interaction can lead to the loss of contact, which interrupts the energy supply and originates arcing between the pantograph and the catenary, or to excessive contact forces that promote wear between the contacting elements. Another important issue is assessing on how the front pantograph influences the dynamic performance of the rear one in trainsets with two pantographs. In this work, the track and environmental conditions influence on the pantograph-catenary is addressed, with particular emphasis in the multiple pantograph operations. These studies are performed for high speed trains running at 300 km/h with relation to the separation between pantographs. Such studies contribute to identify the service conditions and the external factors influencing the contact quality on the overhead system. (C) 2013 Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Considering that recent european high-speed railway system has a traction power system of kV 50 Hz, which causes electromagnetic emission for the outside world, it is important to dimension the railway system emissions, using a frequency/distance dependent propagation model. This paper presents an enhanced theoretical model for VLF to UHF propagation, railway system oriented. It introduces the near field approach (crucial in low frequency propagation) and also considers the source characteristics and type of measuring antenna. Simulations are presented, and comparisons are set with earlier far field models. Using the developed model, a real case study was performed in partnership with Refer Telecom (portuguese telecom operator for railways). The new propagation model was used in order to predict the future high-speed railway electromagnetic emissions in the Lisbon north track. The results show the model's prediction capabilities and also its applicability to realistic scenarios.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

O presente trabalho consiste na implementação em hardware de unidades funcionais dedicadas e optimizadas, para a realização das operações de codificação e descodificação, definidas na norma de codificação com perda Joint Photographic Experts Group (JPEG), ITU-T T.81 ISO/IEC 10918-1. Realiza-se um estudo sobre esta norma de forma a caracterizar os seus principais blocos funcionais. A finalidade deste estudo foca-se na pesquisa e na proposta de optimizações, de forma a minimizar o hardware necessário para a realização de cada bloco, de modo a que o sistema realizado obtenha taxas de compressão elevadas, minimizando a distorção obtida. A redução de hardware de cada sistema, codificador e descodificador, é conseguida à custa da manipulação das equações dos blocos Forward Discrete Cosine Transform (FDCT) e Quantificação (Q) e dos blocos Forward Discrete Cosine Transform (IDCT) e Quantificação Inversa (IQ). Com as conclusões retiradas do estudo e através da análise de estruturas conhecidas, descreveu-se cada bloco em Very-High-Speed Integrated Circuits (VHSIC) Hardware Description Language (VHDL) e fez-se a sua síntese em Field Programmable Gate Array (FPGA). Cada sistema implementado recorre à execução de cada bloco em paralelo de forma a optimizar a codificação/descodificação. Assim, para o sistema codificador, será realizada a operação da FDCT e Quantificação sobre duas matrizes diferentes e em simultâneo. O mesmo sucede para o sistema descodificador, composto pelos blocos Quantificação Inversa e IDCT. A validação de cada bloco sintetizado é executada com recurso a vectores de teste obtidos através do estudo efectuado. Após a integração de cada bloco, verificou-se que, para imagens greyscale de referência com resolução de 256 linhas por 256 colunas, é necessário 820,5 μs para a codificação de uma imagem e 830,5 μs para a descodificação da mesma. Considerando uma frequência de trabalho de 100 MHz, processam-se aproximadamente 1200 imagens por segundo.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Developments in digital detector technologies have been taking place and new digital technologies are available for clinical practice. This chapter is intended to give a technical state-of-the-art overview about computed radiography (CR) and digital radiography (DR) detectors. CR systems use storage-phosphor image plates with a separate image readout process and DR technology converts X-rays into electrical charges by means of a readout process using TFT arrays. Digital detectors offer several advantages when compared to analogue detectors. The knowledge about digital detector technology for use in plain radiograph examinations is thus a fundamental topic to be acquired by radiology professionals and students. In this chapter an overview of digital radiography systems (both CR and DR) currently available for clinical practice is provided.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The characterization of physical properties of digital imaging systems requires the determination and measurement of detectors’ physical performance. Those measures such as modulation transfer function (MTF), noise power spectra (NPS), and detective quantum efficiency (DQE) provide objective evaluations of digital detectors’ performance. To provide an MTF, NPS, and DQE calculation from raw-data images it is necessary to implement a method that is undertaken by two major steps: (1) image acquisition and (2) quantitative measure determination method. In this chapter a comprehensive description about a method to provide the measure of performance of digital radiography detectors is provided.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This chapter addresses technical issues concerning digital technologies. Radiological equipment and technique are briefly introduced together with a discussion about requirements and advantages of digital technologies. Digital technologies offer several advantages when compared to conventional analogical systems, or screen–film (SF) systems. While in clinical practice the practitioners should be aware of technical factors such as image acquisition, management of patient dose, and diagnostic image quality. Thus, digital technologies require an up-to-date scientific knowledge concerning their use in projection radiography. In this chapter, technical considerations concerning digital technologies are provided.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The assessment of patient dose has gained increased attention, still being an issue of concern that arises from the use of digital systems. The development of digital technology offers the possibility for a reduction of radiation dose around 50% without loss in image quality when compared to a conventional screen–film system. Digital systems give an equivalent or superior diagnostic performance and also several other advantages, but the risk of overexposure with no adverse effect on image quality could be present. This chapter refers to the management of patient dose and provides an explanation of dose-related concepts. In this chapter, exposure influence in dose and image representation and the effects of radiation exposure are also discussed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Digital radiography detectors—based on different technological solutions—are currently available for clinical applications and widespread in clinical practice. Computed radiography (CR) and digital radiology systems have been available for clinical applications and the trend over the last few years has become digital. Radiology departments have been changing from traditional screen–film technology to digital technology. This chapter is intended to give the reader a practical understanding about the key aspects concerning digital systems, related to the performance of different technologies, image quality, and dose and patient safety/protection. The discussion around an optimization framework for digital systems is provided.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Once in a digital form, a radiographic image may be processed in several ways in order to turn the visualization an act of improved diagnostic value. Practitioners should be aware that, depending on each clinical context, digital image processing techniques are available to help to unveil visual information that is, in fact, carried by the bare digital radiograph and may be otherwise neglected. The range of visual enhancement procedures includes simple techniques that deal with the usual brightness and contrast manipulation up to much more elaborate multi-scale processing that provides customized control over the emphasis given to the relevant finer anatomical details. This chapter is intended to give the reader a practical understanding of image enhancement techniques that might be helpful to improve the visual quality of the digital radiographs and thus to contribute to a more reliable and assertive reporting.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Plain radiography still accounts for the vast majority of imaging studies that are performed at multiple clinical instances. Digital detectors are now prominent in many imaging facilities and they are the main driving force towards filmless environments. There has been a working paradigm shift due to the functional separation of acquisition, visualization, and storage with deep impact in the imaging workflows. Moreover with direct digital detectors images are made available almost immediately. Digital radiology is now completely integrated in Picture Archiving and Communication System (PACS) environments governed by the Digital Imaging and Communications in Medicine (DICOM) standard. In this chapter a brief overview of PACS architectures and components is presented together with a necessarily brief account of the DICOM standard. Special focus is given to the DICOM digital radiology objects and how specific attributes may now be used to improve and increase the metadata repository associated with image data. Regular scrutiny of the metadata repository may serve as a valuable tool for improved, cost-effective, and multidimensional quality control procedures.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this paper, we present the results of mammography quality control tests related to the work with Portuguese mammography equipment, either in conventional or in digital mammography computed radiography, showing the main differences in the tested equipments. Quality control in mammography is a very special area of quality control in radiology, which demands relatively high knowledge on physics. Digital imaging is changing the standards of the radiographic imaging. Regarding mammography, this is yet a controversial issue owing to some limitations of the digital detectors, like the resolution for instance. A complete set of results regarding radiation protection of the patients submitted to mammography diagnosis is presented. A discussion of the quality image parameters and its interpretation in conventional and digital mammography is presented. In conclusion, we present a sample of results that can be considered as characteristics of mammography equipment in Portugal.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Trabalho de Projeto para obtenção do grau de Mestre em Engenharia de Eletrónica e Telecomunicações

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Lossless compression algorithms of the Lempel-Ziv (LZ) family are widely used nowadays. Regarding time and memory requirements, LZ encoding is much more demanding than decoding. In order to speed up the encoding process, efficient data structures, like suffix trees, have been used. In this paper, we explore the use of suffix arrays to hold the dictionary of the LZ encoder, and propose an algorithm to search over it. We show that the resulting encoder attains roughly the same compression ratios as those based on suffix trees. However, the amount of memory required by the suffix array is fixed, and much lower than the variable amount of memory used by encoders based on suffix trees (which depends on the text to encode). We conclude that suffix arrays, when compared to suffix trees in terms of the trade-off among time, memory, and compression ratio, may be preferable in scenarios (e.g., embedded systems) where memory is at a premium and high speed is not critical.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A recente norma IEEE 802.11n oferece um elevado débito em redes locais sem fios sendo por isso esperado uma adopção massiva desta tecnologia substituindo progressivamente as redes 802.11b/g. Devido à sua elevada capacidade esta recente geração de redes sem fios 802.11n permite um crescimento acentuado de serviços audiovisuais. Neste contexto esta dissertação procura estudar a rede 802.11n, caracterizando o desempenho e a qualidade associada a um serviço de transmissão de vídeo, recorrendo para o efeito a uma arquitectura de simulação da rede 802.11n. Desta forma é caracterizado o impacto das novas funcionalidades da camada MAC introduzidas na norma 801.11n, como é o caso da agregação A-MSDU e A-MPDU, bem como o impacto das novas funcionalidades da camada física como é o caso do MIMO; em ambos os casos uma optimização da parametrização é realizada. Também se verifica que as principais técnicas de codificação de vídeo H.264/AVC para optimizar o processo de distribuição de vídeo, permitem optimizar o desempenho global do sistema de transmissão. Aliando a optimização e parametrização da camada MAC, da camada física, e do processo de codificação, é possível propor um conjunto de configurações que permitem obter o melhor desempenho na qualidade de serviço da transmissão de conteúdos de vídeo numa rede 802.11n. A arquitectura de simulação construída nesta dissertação é especificamente adaptada para suportar as técnicas de agregação da camada MAC, bem como para suportar o encapsulamento em protocolos de rede que permitem a transmissão dos pacotes de vídeo RTP, codificados em H.264/AVC.