32 resultados para Heart Parameters
em Repositório Científico do Instituto Politécnico de Lisboa - Portugal
Resumo:
A crucial method for investigating patients with coronary artery disease (CAD) is the calculation of the left ventricular ejection fraction (LVEF). It is, consequently, imperative to precisely estimate the value of LVEF--a process that can be done with myocardial perfusion scintigraphy. Therefore, the present study aimed to establish and compare the estimation performance of the quantitative parameters of the reconstruction methods filtered backprojection (FBP) and ordered-subset expectation maximization (OSEM). Methods: A beating-heart phantom with known values of end-diastolic volume, end-systolic volume, and LVEF was used. Quantitative gated SPECT/quantitative perfusion SPECT software was used to obtain these quantitative parameters in a semiautomatic mode. The Butterworth filter was used in FBP, with the cutoff frequencies between 0.2 and 0.8 cycles per pixel combined with the orders of 5, 10, 15, and 20. Sixty-three reconstructions were performed using 2, 4, 6, 8, 10, 12, and 16 OSEM subsets, combined with several iterations: 2, 4, 6, 8, 10, 12, 16, 32, and 64. Results: With FBP, the values of end-diastolic, end-systolic, and the stroke volumes rise as the cutoff frequency increases, whereas the value of LVEF diminishes. This same pattern is verified with the OSEM reconstruction. However, with OSEM there is a more precise estimation of the quantitative parameters, especially with the combinations 2 iterations × 10 subsets and 2 iterations × 12 subsets. Conclusion: The OSEM reconstruction presents better estimations of the quantitative parameters than does FBP. This study recommends the use of 2 iterations with 10 or 12 subsets for OSEM and a cutoff frequency of 0.5 cycles per pixel with the orders 5, 10, or 15 for FBP as the best estimations for the left ventricular volumes and ejection fraction quantification in myocardial perfusion scintigraphy.
Resumo:
The benefits of cardiac resynchronization therapy (CRT) in the health-related quality of life (HRQL) are largely demonstrated in selected patients with severe congestive heart failure (CHF). However, the differences between responders and non-responders, with regard to the effect of CRT in the various dimensions that constitute HRQL are still a matter of discussion. Objective: To evaluate the impact of CRT on the HRQL of patients with CHF refractory to optimal pharmacological therapy, within 6 months after CRT. Methods: 43 patients, submitted to successful implantation of CRT, were evaluated in hospital just before intervention and in the outpatient clinic within 6 months after CRT. HRQL was analyzed based on the Kansas City Cardiomyopathy Questionnaire (KCCQ). Patients were classified as super-responders (ejection fraction of left ventricle - LVEF - ≥45% post-CRT), n=15, responders (sustained improvement in functional class and LVEF increased by 15%), n=19, and non-responders (no clinical or LVEF improvement), n=9. Results: In the group of super-responders, CRT was associated with an improvement in HRQL for the various fields and sums assessed (ρ<0.05); in responders, CRT has been associated with an improvement of HRQL in the various fields and sums, except in the self-efficacy dimension (ρ<0.05); in non-responders, CRT was not associated with improvement of HRQL. Conclusion: In a population with severe CHF undergoing CRT, the patients with clinical and echocardiographic positive response, obtained a favorable impact in all dimensions of HRQL, while the group without response to CRT showed no improvement. These data reinforces the importance of HRQL as a multidimensional tool for assessment of benefits in clinical practice.
Resumo:
Esta tese pretende contribuir para o estudo e análise dos factores relacionados com as técnicas de aquisição de imagens radiológicas digitais, a qualidade diagnóstica e a gestão da dose de radiação em sistema de radiologia digital. A metodologia encontra-se organizada em duas componentes. A componente observacional, baseada num desenho do estudo de natureza retrospectiva e transversal. Os dados recolhidos a partir de sistemas CR e DR permitiram a avaliação dos parâmetros técnicos de exposição utilizados em radiologia digital, a avaliação da dose absorvida e o índice de exposição no detector. No contexto desta classificação metodológica (retrospectiva e transversal), também foi possível desenvolver estudos da qualidade diagnóstica em sistemas digitais: estudos de observadores a partir de imagens arquivadas no sistema PACS. A componente experimental da tese baseou-se na realização de experiências em fantomas para avaliar a relação entre dose e qualidade de imagem. As experiências efectuadas permitiram caracterizar as propriedades físicas dos sistemas de radiologia digital, através da manipulação das variáveis relacionadas com os parâmetros de exposição e a avaliação da influência destas na dose e na qualidade da imagem. Utilizando um fantoma contraste de detalhe, fantomas antropomórficos e um fantoma de osso animal, foi possível objectivar medidas de quantificação da qualidade diagnóstica e medidas de detectabilidade de objectos. Da investigação efectuada, foi possível salientar algumas conclusões. As medidas quantitativas referentes à performance dos detectores são a base do processo de optimização, permitindo a medição e a determinação dos parâmetros físicos dos sistemas de radiologia digital. Os parâmetros de exposição utilizados na prática clínica mostram que a prática não está em conformidade com o referencial Europeu. Verifica-se a necessidade de avaliar, melhorar e implementar um padrão de referência para o processo de optimização, através de novos referenciais de boa prática ajustados aos sistemas digitais. Os parâmetros de exposição influenciam a dose no paciente, mas a percepção da qualidade de imagem digital não parece afectada com a variação da exposição. Os estudos que se realizaram envolvendo tanto imagens de fantomas como imagens de pacientes mostram que a sobreexposição é um risco potencial em radiologia digital. A avaliação da qualidade diagnóstica das imagens mostrou que com a variação da exposição não se observou degradação substancial da qualidade das imagens quando a redução de dose é efectuada. Propõe-se o estudo e a implementação de novos níveis de referência de diagnóstico ajustados aos sistemas de radiologia digital. Como contributo da tese, é proposto um modelo (STDI) para a optimização de sistemas de radiologia digital.
Evaluation of exposure parameters in plain radiography: a comparative study with european guidelines
Resumo:
Typical distribution of exposure parameters in plain radiography is unknown in Portugal. This study aims to identify exposure parameters that are being used in plain radiography in the Lisbon area and to compare the collected data with European references [Commission of European Communities (CEC) guidelines]. The results show that in four examinations (skull, chest, lumbar spine and pelvis), there is a strong tendency of using exposure times above the European recommendation. The X-ray tube potential values (in kV) are below the recommended values from CEC guidelines. This study shows that at a local level (Lisbon region), radiographic practice does not comply with CEC guidelines concerning exposure techniques. Further national/local studies are recommended with the objective to improve exposure optimisation and technical procedures in plain radiography. This study also suggests the need to establish national/local diagnostic reference levels and to proceed to effective measurements for exposure optimisation.
Resumo:
The benefits of cardiac resynchronization therapy (CRT) in the quality of life have been largely demonstrated in selected patients with severe congestive heart failure (CHF). However, the differences between responders and non-responders, with regard to the effect of CRT in the various dimensions of quality of life is still a matter of discussion. Objective: to evaluate the impact of CRT on the quality of life of patients with CHF refractory to optimal pharmacological therapy, within 6 months after CRT.
Resumo:
Introduction: Meeting the actual role of positive psychology, begins to be recognized the relation of positive variables with health. Objective: To know the relation of happiness, hope and affection with quality of life in individuals with heart failure. Population and Methodology: 128 individuals with heart failure, 98 men and 30 women, 61.9±12,1 years of age, 6,6±3,9 years in school and 74,2% retired because of this disease. 56,3% were in Class III of New York Heart Association, with poor left ventricular ejection fraction (25,3±6,2%). The clinical history was of 9,4±8,5 years for this heart disease and had at least one hospitalization due to heart failure with 51,6% having ischemic heart disease.
Resumo:
Introduction: Meeting the actual role of positive psychology, begins to be recognized the contribution of positive variables in health outcomes. Objective: To know the contribution of happiness, hope and affection individually and as a whole in the quality of life and functionality of individuals with heart failure. Population and Methodology: 128 individuals with heart failure, 98 men and 30 women, 61.9±12,1 years of age, 6,6±3,9 years of school and 74,2% retired because of this disease. 56,3% were in Class III of New York Heart Association, with poor left ventricular ejection fraction (25,3±6,2%). The clinical history was of 9,4±8,5 years for this heart disease and had at least one hospitalization due to heart failure with 51,6% having ischemic heart disease.
Resumo:
Heart failure is the final stage of most of cardiac diseases. It is a complex syndrome in which the patients should have the following features: symptoms of heart failure, typically shortness of breath at rest or during exertion, and/or fatigue; signs of fluid retention such as pulmonary congestion or ankle swelling; and objective evidence of an abnormality of the structure or function of the heart at rest. This progressive syndrome as a high incidence and prevalence and poor prognosis: four-year mortality is around 50% with 40% of the patients admitted to hospital dying or readmitted within a year. With ageing, many patients will develop chronic heart failure, which, because of its symptoms, patient’s awareness of their risk of dying, and the effects of therapy, together with frequent hospitalizations, has considerable impact on patient’s health-related quality of life.
Resumo:
Mestrado em Tecnologia de Diagnóstico e Intervenção Cardiovascular. Área de especialização: Intervenção Cardiovascular.
Resumo:
Mestrado em Tecnologia de Diagnóstico e Intervenção Cardiovascular. Área de especialização: Intervenção Cardiovascular.
Resumo:
Mestrado em Tecnologia de Diagnóstico e Intervenção Cardiovascular. Área de especialização - Ultrassonografia Cardiovascular
Resumo:
Mestrado em Tecnologia de Diagnóstico e Intervenção Cardiovascular. Área de Especialização: Ultrassonografia Cardiovascular
Resumo:
Mestrado em Tecnologia de Diagnóstico e Intervenção Cardiovascular - Área de especialização: Ultrassonografia Cardiovascular.
Resumo:
This work reports on the synthesis of CrO2 thin films by atmospheric pressure CVD using chromium trioxide (CrO3) and oxygen. Highly oriented (100) CrO2 films containing highly oriented (0001) Cr2O3 were grown onto Al2O3(0001) substrates. Films display a sharp magnetic transition at 375 K and a saturation magnetization of 1.92 mu(B)/f.u., close to the bulk value of 2 mu(B)/f.u. for the CrO2.
Resumo:
Myocardial Perfusion Gated Single Photon Emission Tomography (Gated-SPET) imaging is used for the combined evaluation of myocardial perfusion and left ventricular (LV) function. But standard protocols of the Gated-SPECT studies require long acquisition times for each study. It is therefore important to reduce as much as possible the total duration of image acquisition. However, it is known that this reduction leads to decrease on counts statistics per projection and raises doubts about the validity of the functional parameters determined by Gated-SPECT. Considering that, it’s difficult to carry out this analysis in real patients. For ethical, logistical and economical matters, simulated studies could be required for this analysis. Objective: Evaluate the influence of the total number of counts acquired from myocardium, in the calculation of myocardial functional parameters (LVEF – left ventricular ejection fraction, EDV – end-diastolic volume, ESV – end-sistolic volume) using routine software procedures.