20 resultados para Health Consequences
em Repositório Científico do Instituto Politécnico de Lisboa - Portugal
Resumo:
Although the adverse health consequences of ingestion of food contaminated with aflatoxin B1 (AFB1) are known, relatively few studies are available on the adverse effects of exposure in occupational settings. Taking this into consideration, our study was developed aiming to elucidate the possible effects of occupational exposure to AFB1 in Portuguese swine production facilities using a specific biomarker to assess exposure to AFB1. In total, 28 workers participated in this study, providing blood samples, and a control group (n = 30) was composed of subjects without any type of agricultural activity. Fungal contamination was also studied by conventional methods through air, surfaces, and new and used floor coverage. Twenty-one workers (75%) showed detectable levels of AFB1 with values ranging from <1 ng/ml to 8.94 ng/ml and with a mean value of 1.91 ± 1.68 ng/ml. In the control group, the AFB1 values were all below 1 ng/ml. Twelve different Aspergillus species were identified. Aspergillus versicolor presented the highest airborne spore counts (3210 CFU/m3) and was also detected in higher values in surfaces (>300 CFU/cm2). Data indicate that exposure to AFB1 occurs in swine barns, and this site serves as a contamination source in an occupational setting.
Resumo:
Introduction: Familial amyloidotic polyneuropathy (FAP) is a neurodegenerative disease that leads to sensory and motor polyneuropathies as well as functional limitations. So far, liver transplantation is the only treatment for FAP because the mutated protein causing the disease is mainly produced in the liver. With the increasing survival of transplant recipients, functional and cardiovascular problems as consequences of immunosuppressant side effects are increasing associated with sedentary lifestyles and/or retransplantation status. We sought to analyze the impact of exercise training programs on 1 FAP patient’s course long-term after liver transplantation. Methodology. A FAP patient (female; 49 years of age; body mass index 18.8 kg/m2) underwent a liver transplantation 133 months before assessment. She was assessed for body composition, isometric quadriceps muscle strength, functional capacity, fatigue, and levels of physical activity before and after a 6-month period of combined exercise training. Results: After the exercise training program, almost all variables were improved, namely, total body skeletal muscle mass, proximal femoral bone mineral density, quadriceps strength, maximal oxygen consumption on 6 minutes walk test (6mwt) or VO2peak, total ventilation on 6mwt, and fatigue. The improvement in distance on 6mwt (69.2 m) was clinically significant. Preintervention the levels of physical activity were below international recommendations for health; after the program they achieved the recommendations. Conclusion: The results showed an improvement in functional capacity with a decrease in future disability risk associated with a better lifestyle with respect to physical activity levels in 1 patient.
Resumo:
International statistics show that the problem of the accidents at work is far away to be solved (ILO estimates that every year about 270 million work accidents and 160 million occupational diseases resulting in the death of more than 2 million workers occurs in the world). That's why the EU global goal concerning the community' strategy for occupational health and safety for 2007-2012 is to reduce in 25% the incidence rate of occupational accidents and diseases. In this prospect it is presented a case study which justify the need to develop studies in Safety, Hygiene and Health at Work area as a way to encourage the managers to implement preventive actions and strategies, besides meeting the legal requirements, in order to reduce the occurrence of work accidents, improve the work conditions and therefore obtain benefits in added values and reinforced competition. The general objective of this study is to describe the work situations, identify the dangers and associate the potential risks and consequences; evaluate and value the risk. The study uses the Failure Table methodology and, in the business area of an organization which will be from now on designated as MANTEM that works in the electromechanical maintenance area. The results were, amongst others, some actions to be implemented to eliminate/minimize risks.
Resumo:
The benefits of cardiac resynchronization therapy (CRT) in the health-related quality of life (HRQL) are largely demonstrated in selected patients with severe congestive heart failure (CHF). However, the differences between responders and non-responders, with regard to the effect of CRT in the various dimensions that constitute HRQL are still a matter of discussion. Objective: To evaluate the impact of CRT on the HRQL of patients with CHF refractory to optimal pharmacological therapy, within 6 months after CRT. Methods: 43 patients, submitted to successful implantation of CRT, were evaluated in hospital just before intervention and in the outpatient clinic within 6 months after CRT. HRQL was analyzed based on the Kansas City Cardiomyopathy Questionnaire (KCCQ). Patients were classified as super-responders (ejection fraction of left ventricle - LVEF - ≥45% post-CRT), n=15, responders (sustained improvement in functional class and LVEF increased by 15%), n=19, and non-responders (no clinical or LVEF improvement), n=9. Results: In the group of super-responders, CRT was associated with an improvement in HRQL for the various fields and sums assessed (ρ<0.05); in responders, CRT has been associated with an improvement of HRQL in the various fields and sums, except in the self-efficacy dimension (ρ<0.05); in non-responders, CRT was not associated with improvement of HRQL. Conclusion: In a population with severe CHF undergoing CRT, the patients with clinical and echocardiographic positive response, obtained a favorable impact in all dimensions of HRQL, while the group without response to CRT showed no improvement. These data reinforces the importance of HRQL as a multidimensional tool for assessment of benefits in clinical practice.
Resumo:
Introdução – Apesar de em Portugal se verificar o aumento da indústria da produção de aves para consumo humano, apenas alguns estudos incidem sobre a qualidade do ar interior e as implicações da sua degradação. Objectivos – Descrever a contaminação fúngica num aviário, analisar possíveis associações com a temperatura ambiente e a humidade relativa e o possível impacto na saúde dos consumidores e trabalhadores desta unidade. Métodos – Foi desenvolvido um estudo descritivo para avaliar a contaminação fúngica num aviário. Colheram‑se 5 amostras de ar de 100 litros através do método de compactação e 4 amostras de superfícies, utilizando a técnica da zaragatoa e um quadrado de 10 cm de lado de metal. Simultaneamente, os parâmetros ambientais – temperatura ambiente e humidade relativa – também foram medidos. Resultados – Foram identificadas vinte espécies de fungos no ar, sendo os seguintes os quatro géneros mais comummente isolados: Cladosporium (40,5%), Alternaria (10,8%), Chrysosporium e Aspergillus (6,8%). Nas superfícies, 21 espécies de fungos foram identificadas, sendo os 4 géneros mais identificados Penicillium (51,8%), Cladosporium (25,4%), Alternaria (6,1%) e Aspergillus (4,2%). Importa referir o facto de Aspergillus flavus, também isolado no ar, ser reconhecido como produtor de micotoxinas (aflatoxina) e Aspergillus fumigatus, uma das espécies isoladas no ar e superfícies, ser capaz de causar aspergilose grave ou fatal. Não se verificou relação significativa (p> 0,05) entre a contaminação fúngica e as variáveis ambientais. Conclusão – Caracterizou‑se a distribuição fúngica no ar e superfícies do aviário e analisou‑se a possível influência das variáveis ambientais. Foi reconhecido um potencial problema de Saúde Pública devido à contaminação fúngica e à possível produção de micotoxinas com a eventual contaminação dos produtos alimentares. A contaminação fúngica, particularmente causada pelo Aspergillus fumigatus, e a possível presença de micotoxinas no ar, devem ser encaradas também como fatores de risco neste contexto ocupacional. ABSTRACT - Background – Although there is an increasingly industry that produce whole chickens for domestic consumption in Portugal, only few investigations have reported on the indoor air of these plants and the consequences of their degradation. Objectives – Describe one poultry environmental fungal contamination analyse possible associations between temperature and relative humidity and its possible impact on the health of consumers and of the poultry workers. Methods – A descriptive study was developed to monitor one poultry fungal contamination. Five air samples of 100 litres through impaction method were collected and 4 swab samples from surfaces were also collected using a 10 cm square of metal. Simultaneously, environmental parameters – temperature and relative humidity – were also measured. Results – Twenty species of fungi in air were identified, being the 4 most commonly isolated the following genera: Cladosporium (40.5%), Alternaria (10.8%), Chrysosporium and Aspergillus (6.8%). In surfaces, 21 species of fungi were identified, being the 4 genera more identified Penicillium (51.8%), Cladosporium (25.4%), Alternaria (6.1%) and Aspergillus (4.2%). In addition, Aspergillus flavus also isolated in the poultry air is a well‑known producer of potent mycotoxins (aflatoxin), and Aspergillus fumigatus, one of the species isolated in air and surfaces, is capable of causing severe or fatal aspergillosis. There was no significant relationship (p>0,05) between fungal contamination and environmental variables. Conclusions – Was characterized fungal distribution in poultry air and surfaces and analyzed the association of environmental variables. It was recognized the Public Health problem because of fungal contamination and also due to probable mycotoxins production with the possible contamination of food products. Fungal contamination, particularly due to the presence of Aspergillus fumigatus and also the possible presence of mycotoxins in the air, should be seen as risk factor in this occupational setting.
Resumo:
Although leadership investigation has become for the last years an election topic with major relevance on organizational studies and accepting peacefully the general idea that organizations are freeland for politics, all these acceptances run against a kind of “fear” from the academy scholars on approaching the political leaderships’ singularities on organizations. Indeed, when we cross over both phenomena we verify that the absence and weaknesses towards the unique characteristics of political leadership on work scenarios are becoming sharped regarding to their predictors, their workers and their organizations, even if we left aside its moderator variables.
Resumo:
Formaldehyde was the first air pollutant, which already in the 1970s emerged as a specifically non-industrial indoor air quality problem. Yet formaldehyde remained an indoor air quality issue and the formaldehyde level in residential indoor air is among the highest of any indoor air contaminant. Formaldehyde concentrations in 4 different indoor settings (schools, office buildings, new dwellings and occupied dwellings) in Portugal were measured using Photo Ionization Detection (PID) equipment (11,7 eV lamps). All the settings presented results higher than the reference value proposed by Portuguese legislation. Furthermore, occupied dwellings showed 3 units with results above the reference. We could conclude that formaldehyde presence is a reality in monitored indoor settings. Concentration levels are higher than the Portuguese reference value for indoor settings and these can indicate health problems for occupants.
Resumo:
Introduction - Microscopic filamentous fungi, under suitable environmental conditions, can lead to the production of highly toxic chemical substances, commonly known as mycotoxins. The most widespread and studied mycotoxins are metabolites of some genera of moulds such as Aspergillus, Penicillium and Fusarium. Quite peculiar conditions may influence mycotoxin biosynthesis, such as climate, geographical location, cultivation practices, storage and type of substrate. Toxicity has been extensively investigated for the most important mycotoxins, such as aflatoxins, ochratoxin A and Fusarium toxins, and much information derived from toxicokinetics in animal models has also been obtained. The adverse effects are mainly related to genotoxicity, carcinogenicity, mutagenicity, teratogenicity and immunotoxicity. Aim of the study - To identify fungal species able to produce important mycotoxins in different Portuguese settings.
Resumo:
Exposure to certain fungi can cause human illness. Fungi cause adverse human health effects through three specific mechanisms: generation of a harmful immune response (e.g., allergy or hypersensitivity pneumonitis); direct infection by the fungal organism; by toxic-irritant effects from mold byproducts, such as mycotoxins. In Portugal there is an increasingly industry of large facilities that produce whole chickens for domestic consumption and only few investigations have reported on fungal contamination of the poultry litter. The material used for poultry litter is varied but normally can be constitute by: pine shavings; sawdust of eucalyptus; other types of wood; peanut; coffee; sugar cane; straw; hay; grass; paper processed. Litter is one of the most contributive factors to fungal contamination in poultries. Spreading litter is one of the tasks that normally involve higher exposure of the poultry workers to dust, fungi and their metabolites, such as VOC’s and mycotoxins. After being used and removed from poultries, litter is ploughed into agricultural soils, being this practice potentially dangerous for the soil environment, as well for both humans and animals. The goal of this study was to characterize litter’s fungal contamination and also to report the incidence of keratinophilic and toxigenic fungi.
Resumo:
Over the centuries there has been a growing trend of societies and it is possible to verify their economic growth. This growth has provided an increased pressure on natural resources, often over-reaching the boundaries of each country, which has called into question the level of environmental sustainability in different countries. Sustainability is understood as a complex concept involving ecological, social, economic dimensions and temporal urban processes. Therefore, Firmino (2009) suggests that the ecological footprint (EF) allows people to establish dependency relations between human activities and the natural resources required for such activities and for the absorption of waste generated. According to Bergh & Verbruggen (1999) the EF is an objective, impartial and one-dimensional indicator that enables people to assess the sustainability. The Superior Schools have a crucial role in building the vision of a sustainable future as a reality, because in transmitting values and environmental principles to his students, are providing that they, in exercising his professional activity, make decisions weighing the environmental values. This ensures improved quality of life. The present study aims to determine the level of environmental sustainability of the Academic Community of Lisbon College of Health Technology (ESTeSL), by calculating the EF, and describe whether a relation between Footprint and various socio-demographic characteristics of the subjects.
Resumo:
Since industrialization and the formation of larger urban centers in the nineteenth century, pollution of the environment was always present in daily life in various ways, namely in the form of light. Light pollution can cause various consequences, both for humans and for their ecosystem, producing effects on environmental, social, economic and scientific level. In Portugal, the lighting is responsible for 3% of total electricity consumption, energy costs are in some cases more than 50% towards the costs incurred by municipalities with energy, checking-in recent years a trend similar to that improvement of illumination levels in the region (about 4 to 5% per year). Proper use of lighting brings many benefits both to the citizen and environment, since greater energy efficiency can contribute to reducing CO2 emissions, energy costs, as well as to decrease the use of resources not-renewable and/or contamination of renewable resources, which can occurs in the process of obtaining electricity. The present study has a main goal to analyze the illuminance levels associated to the public lighting of the village of Vialonga, Vila Franca de Xira (Portugal), to verify if it is efficient. The aim is also to relate the efficiency of street lighting with the existence of light pollution.
Resumo:
Although numerous studies have been conducted on microbial contaminants associated with various stages related to poultry and meat products processing, only a few reported on fungal contamination of poultry litter. The goals of this study were to (1) characterize litter fungal contamination and (2) report the incidence of keratinophilic and toxigenic fungi presence. Seven fresh and 14 aged litter samples were collected from 7 poultry farms. In addition, 27 air samples of 25 litters were also collected through impaction method, and after laboratory processing and incubation of collected samples, quantitative colony-forming units (CFU/m3) and qualitative results were obtained. Twelve different fungal species were detected in fresh litter and Penicillium was the most frequent genus found (59.9%), followed by Alternaria (17.8%), Cladosporium (7.1%), and Aspergillus (5.7%). With respect to aged litter, 19 different fungal species were detected, with Penicillium sp. the most frequently isolated (42.3%), followed by Scopulariopsis sp. (38.3%), Trichosporon sp. (8.8%), and Aspergillus sp. (5.5%). A significant positive correlation was found between litter fungal contamination (CFU/g) and air fungal contamination (CFU/m3). Litter fungal quantification and species identification have important implications in the evaluation of potential adverse health risks to exposed workers and animals. Spreading of poultry litter in agricultural fields is a potential public health concern, since keratinophilic (Scopulariopsis and Fusarium genus) as well as toxigenic fungi (Aspergillus, Fusarium, and Penicillium genus) were isolated.
Resumo:
Cyanobacteria are prokaryotic, plantlike organisms present in lakes, recreational waters, and reservoirs, and often dominate phytoplankton communities in warm, nutrient-enriched hard waters. A stable water column rich in certain nutrients, especially nitrogen and phosphorus, is associated with favorable environmental conditions that support development of cyanobacterial population maxima or "blooms." Under specific conditions, cyanobacteria produce toxins that are responsible for acute poisoning and death of animals and humans. The main aim of this study was to correlate the presence of cyanobacteria blooms with potential toxicity to humans as a public health issue. In Portugal, seven reservoirs located in the southern region were selected and studied between 2000 and 2008. Reservoirs were characterized by physical and chemical aspects, and identification of phytoplankton communities. In the case of cyanobacterial blooms, toxins that affected the liver, nervous system, and skin were detected, namely, Microcystis aeruginosa, Aphanizomenon spp., and Oscillatoria. These findings suggest the presence of a potential risk for public health, and indicate the need to implement mitigation measures in all studied reservoirs. These measures may involve (1) water eutrophication control to avoid blooms, (2) appropriate treatment of water for human consumption, and (3) public warnings or information to those individuals that use these reservoirs for several recreational activities.
Resumo:
Poor air quality in a pig-confinement building may potentially place farmers at higher health risk than other workers for exposure to airborne pollutants that may reach infectious levels. The aim of this study was to assess worker exposure to fungi in indoor environments in Portuguese swine buildings. Air samples from 7 swine farms were collected at a flow rate of 140 L/min, at 1 m height, onto malt extract agar supplemented with chloramphenicol (MEA). Surfaces samples of the same indoor sites were obtained by swabbing the surfaces. Samples from the floor covering were also collected from four of seven swine farms. All collected samples were incubated at 27°C for 5-7 days. After lab processing and incubation of obtained samples, quantitative colony-forming units (CFU)/m(3), CFU/cm(2), and CFU/g and qualitative results were determined with identification of isolated fungal species. Aspergillus versicolor was the most frequent species found in air (21%), followed by Scopulariopsis brevicaulis (17%) and Penicillium sp. (14%). Aspergillus versicolor was also the most frequent species noted on surfaces (26.6%), followed by Cladosporium sp. (22.4%) and Scopulariopsis brevicaulis (17.5%). Chrysosporium was the most frequently found genera in the new floor covering (38.5%), while Mucor was the most prevalent genera (25.1%) in used floor covering. Our findings corroborate a potential occupational health threat due to fungi exposure and suggest the need for a preventive strategy.
Resumo:
Os Hospitais, equipamentos de interesse público, são edifícios cujos desempenho e disponibilidade das suas instalações e equipamentos podem comprometer a prestação de cuidados de saúde, pelo que nestes estabelecimentos, a Manutenção Preventiva assume um papel relevante. Nesse sentido, pretendeu-se nesta dissertação definir uma estratégia específica que permita efectuar o planeamento da manutenção preventiva de um edifício hospitalar, enquanto infraestrutura para desenvolvimento da actividade clínica. Para tal, foi efectuada uma pesquisa bibliográfica, com a qual se identificaram conceitos de manutenção e requisitos a serem tidos em conta na manutenção de edifícios hospitalares. Foi efectuada uma caracterização genérica do objecto de manutenção, limitada no âmbito desta dissertação às principais componentes dos sistemas de construção e das instalações de águas e esgotos, que podem integrar um edifício hospitalar actual, atendendo às especificações e recomendações técnicas vigentes para este tipo de edifícios. Foram identificados os objectivos e requisitos de manutenção nestes edifícios, estabelecidos pelas condições de funcionamento pretendidas, pelos critérios de durabilidade exigidos pelo Dono de Obra, pelo nível de desempenho funcional requerido para as suas componentes e pelo grau de operacionalidade imposto nas suas diferentes unidades funcionais. Tendo em consideração que a criticidade de uma componente não depende só do contexto operacional da área funcional em se insere mas também das consequências que o seu estado de funcionamento pode acarretar para a unidade funcional. Foi exemplificada a análise dos modos de falha, sua criticidade e seus efeitos para hierarquização do risco associado nas componentes estudadas. As fichas exemplificativas dos planos de manutenção preventiva, que se apresentam no âmbito desta dissertação para algumas componentes básicas, integram acções e procedimentos que derivam de uma análise aos seus modos de falha e seus efeitos, bem como de recomendações técnicas exigências da regulamentação em vigor.