7 resultados para Gambling expenditure
em Repositório Científico do Instituto Politécnico de Lisboa - Portugal
Resumo:
Introduction - Knowledge on the metabolic changes and nutritional needs during the postsurgical anabolic phase in infants is scarce. This analysis explores the associations of resting energy expenditure (REE) and macronutrient utilization with body composition of full-term infants, during catch-up growth after corrective surgery of major congenital anomalies. Methods - A cohort of full-term appropriate for-gestational-age neonates subjected to corrective surgery of major congenital anomalies were recruited after gaining weight for at least one week. REE and macronutrient utilization, measured by respiratory quotient (RQ), were assessed by indirect calorimetry using the Deltatrac II Metabolic Monitor ®. Body composition, expressed as fat-free mass (FFM), fat mass (FM) and adiposity defined as percentage of FM (% FM), was measured by air displacement plethysmography using the Pea Pod ®. Results - Four infants were included at 3 to 5 postnatal weeks. Recommended energy and macronutrient intakes for healthy term infants were provided. Through the study, the median (min-max) REE (Kcal/Kg FFM/d) was 70.8 (60.6-96.1) and RQ was 0.99 (0.72-1.20). Steady increases in both body weight and FFM were associated with initial decrease in FM and adiposity followed by their increase. Low RQ preceded decrease in adiposity. Conclusion - The marked adiposity depletion, not expected during steady weight gain in the postsurgical period, prompts us to report this finding. The subsequent adiposity catch-up was associated with relatively high REE and RQ, suggesting preferential oxidation of carbohydrates and preservation of lipids for fat storage.
Resumo:
Introdução – Os componentes protésicos têm um papel fundamental na eficiência energética da marcha dos indivíduos amputados. Esta é uma área de conhecimento ainda em desenvolvimento, onde a investigação desempenha um papel central. Objectivos – Comparar e analisar o efeito de dois joelhos protésicos, 3R34, monocêntrico modular, de fricção constante, com auxiliar de extensão incorporado (A) e 3R92, monocêntrico modular, com travão de fricção e controlo pneumático da fase de balanço (B) no consumo energético e eficiência da marcha. Metodologia – Um indivíduo do sexo masculino de 27 anos, com amputação transfemural longa, foi sujeito a um protocolo submáximo de avaliação da resposta ao exercício em passadeira rolante (H/P/Cosmos(R) Mercury), através de um sistema de análise de gases breath‑by‑breath (Cosmed Quark PFT Ergo). Foi efetuado o mesmo protocolo com intervalo de dois dias, primeiro utilizando o joelho A e depois o B. As variáveis analisadas foram o consumo de O2 (VO2), o equivalente metabólico (MET) e a eficiência energética da marcha (Quociente de VO2 esperado de um individuo saudável e o VO2 do individuo em estudo). O esforço percecionado foi medido com a escala RPE de Borg. Resultados – O consumo energético com o joelho A (24,2 ml O2/kg/min; 6,9 MET) foi inferior ao obtido com o joelho B (28,68 ml O2/kg/min; 8,2 MET). A eficiência energética da marcha foi mais elevada para o joelho A (43%) do que para o joelho B (39%). Conclusão – A utilização do joelho A na prótese do indivíduo em estudo resulta numa marcha de menor consumo energético e maior eficiência. No entanto, este valor poderá estar influenciado pelo curto período de adaptação ao joelho B, sendo necessários mais estudos para confirmar os resultados do estudo e a influência deste fator. ABSTRACT - Background – Prosthetic components have a crucial role in the energy efficiency of amputee’s gait. This is an area of knowledge still in development, where research plays a central role. Objective – The purpose of this case study is to compare the impact in energy consumption of two prosthetic knees, titanium single‑axis constant friction knee joint with internal extension assist, 3R34 (A) and a single‑axis pneumatic swing phase control, 3R92 (B). Methodology – The participant was a transtibial amputee, male, with 27 years old, with no other clinical or functional impairments. To measure the energy expenditure a submaximal treadmill (H/P/Cosmos(R) Mercury) exercise stress test combined with a breath‑by‑breath analysis system (Cosmed Quark PFT Ergo) was used. The same test was applied to both knees, separated by two days. The analyzed variables were O2 consumption (VO2), metabolic equivalent (MET) and gait efficiency (VO2 ratio expected from a healthy individual and the studied individual). A rate of perceived exertion (Borg’s Scale) was used. Results – The results were favorable to knee A (24.2 ml O2/kg/min; 6.9 MET, 43% efficiency) compared with knee B (28.68 ml O2/kg/min; 8.2 MET, 39% efficiency). Conclusion – In this case, a less energy consumption gait corresponds to the prosthesis with knee A. These values may be influenced by the short adaptation period with knee B, so it’s necessary to perform more studies to confirm the previous results and to understand the truly impact of correct adaptation factor to the best prosthetics components for different patients.
Impacto dos benefícios fiscais, em sede de IRS, em Portugal e a sua evolução no período de 2001-2010
Resumo:
Mestrado em Contabilidade
Resumo:
Trabalho Final de Mestrado para obtenção do grau de Mestre em Engenharia de Electrónica e Telecomunicações
Resumo:
Mestrado em Contabilidade e Análise Financeira
Resumo:
Background: Brown adipose tissue (BAT) plays an important role in whole body metabolism and could potentially mediate weight gain and insulin sensitivity. Although some imaging techniques allow BAT detection, there are currently no viable methods for continuous acquisition of BAT energy expenditure. We present a non-invasive technique for long term monitoring of BAT metabolism using microwave radiometry. Methods: A multilayer 3D computational model was created in HFSS™ with 1.5 mm skin, 3-10 mm subcutaneous fat, 200 mm muscle and a BAT region (2-6 cm3) located between fat and muscle. Based on this model, a log-spiral antenna was designed and optimized to maximize reception of thermal emissions from the target (BAT). The power absorption patterns calculated in HFSS™ were combined with simulated thermal distributions computed in COMSOL® to predict radiometric signal measured from an ultra-low-noise microwave radiometer. The power received by the antenna was characterized as a function of different levels of BAT metabolism under cold and noradrenergic stimulation. Results: The optimized frequency band was 1.5-2.2 GHz, with averaged antenna efficiency of 19%. The simulated power received by the radiometric antenna increased 2-9 mdBm (noradrenergic stimulus) and 4-15 mdBm (cold stimulus) corresponding to increased 15-fold BAT metabolism. Conclusions: Results demonstrated the ability to detect thermal radiation from small volumes (2-6 cm3) of BAT located up to 12 mm deep and to monitor small changes (0.5°C) in BAT metabolism. As such, the developed miniature radiometric antenna sensor appears suitable for non-invasive long term monitoring of BAT metabolism.
Resumo:
Trabalho Final de Mestrado para obtenção do grau de Mestre em Engenharia de Eletrónica e Telecomunicações