35 resultados para ELECTROCHEMILUMINESCENCE DETECTOR

em Repositório Científico do Instituto Politécnico de Lisboa - Portugal


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The characterization of physical properties of digital imaging systems requires the determination and measurement of detectors’ physical performance. Those measures such as modulation transfer function (MTF), noise power spectra (NPS), and detective quantum efficiency (DQE) provide objective evaluations of digital detectors’ performance. To provide an MTF, NPS, and DQE calculation from raw-data images it is necessary to implement a method that is undertaken by two major steps: (1) image acquisition and (2) quantitative measure determination method. In this chapter a comprehensive description about a method to provide the measure of performance of digital radiography detectors is provided.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Está hoje bem estabelecido que os antibióticos são constantemente libertados e introduzidos no meio ambiente em consequência da sua extensa utilização na medicina humana e veterinária. A presença destes compostos tem vindo a ser verificada, por diversos autores, em águas subterrâneas, águas de superfície e águas residuais. O impacto que deriva da acumulação destas substâncias a nível ambiental, nomeadamente, situações de toxicidade e/ou desenvolvimento de resistências bacterianas, impõe um controlo sobre a qualidade das águas no que respeita a estas substâncias. Este estudo pretende explorar a aplicabilidade da extracção por fase sólida (SPE) utilizando resinas de fase reversa C-18, para a determinação de tetraciclina (TC), cloranfenicol (CPA) e estreptomicina (STP) em amostras de água padronizadas. A separação cromatográfica foi elevada a cabo por cromatografia líquida de alta pressão com detector de fotodiodos (HPLC-DAD) empregando uma coluna C18 de fase reversa (30cm x 3.9mm, 5pm de tamanho partícula). A monitorização dos antibióticos foi realizada por um varrimento de comprimentos de onda específicos para cada um dos compostos (357, 277, e 257nm para TC, CPA e STP, respectivamente). O solvente de eluição constituiu um factor determinante na extracção dos antibióticos da resina utilizada, tendo sido conseguidas extracções máximas de 77,1% para a TC e de 15,3% para o CPA; não foi conseguida qualquer recuperação para a STP com a resina utilizada. Assim, o método revelou-se eficaz para a análise conjunta dos antibióticos CPA e TC, recomendando-se a análise da STP por um método separado, dada as suas elevadas características polares.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This article describes an experimental study on ash deposition during the co-firing of bituminous coal with pine sawdust and olive stones in a laboratory furnace. The main objective of this study was to relate the ash deposit rates with the type of biomass burned and its thermal percentage in the blend. The thermal percentage of biomass in the blend was varied between 10% and 50% for both sawdust and olive stones. For comparison purposes, tests have also been performed using only coal or only biomass. During the tests, deposits were collected with the aid of an air-cooled deposition probe placed far from the flame region, where the mean gas temperature was around 640 degrees C. A number of deposit samples were subsequently analyzed on a scanning electron microscope equipped with an energy dispersive X-ray detector. Results indicate that blending sawdust with coal decreases the deposition rate as compared with the firing of unblended coal due to both the sawdust low ash content and its low alkalis content. The co-firing of coal and sawdust yields deposits with high levels of silicon and aluminium which indicates the presence of ashes with high fusion temperature and, thus, with less capacity to adhere to the surfaces. In contrast, in the co-firing of coal with olive stones the deposition rate increases as compared with the firing of unblended coal and the deposits produced present high levels of potassium, which tend to increase their stickiness.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Esta tese pretende contribuir para o estudo e análise dos factores relacionados com as técnicas de aquisição de imagens radiológicas digitais, a qualidade diagnóstica e a gestão da dose de radiação em sistema de radiologia digital. A metodologia encontra-se organizada em duas componentes. A componente observacional, baseada num desenho do estudo de natureza retrospectiva e transversal. Os dados recolhidos a partir de sistemas CR e DR permitiram a avaliação dos parâmetros técnicos de exposição utilizados em radiologia digital, a avaliação da dose absorvida e o índice de exposição no detector. No contexto desta classificação metodológica (retrospectiva e transversal), também foi possível desenvolver estudos da qualidade diagnóstica em sistemas digitais: estudos de observadores a partir de imagens arquivadas no sistema PACS. A componente experimental da tese baseou-se na realização de experiências em fantomas para avaliar a relação entre dose e qualidade de imagem. As experiências efectuadas permitiram caracterizar as propriedades físicas dos sistemas de radiologia digital, através da manipulação das variáveis relacionadas com os parâmetros de exposição e a avaliação da influência destas na dose e na qualidade da imagem. Utilizando um fantoma contraste de detalhe, fantomas antropomórficos e um fantoma de osso animal, foi possível objectivar medidas de quantificação da qualidade diagnóstica e medidas de detectabilidade de objectos. Da investigação efectuada, foi possível salientar algumas conclusões. As medidas quantitativas referentes à performance dos detectores são a base do processo de optimização, permitindo a medição e a determinação dos parâmetros físicos dos sistemas de radiologia digital. Os parâmetros de exposição utilizados na prática clínica mostram que a prática não está em conformidade com o referencial Europeu. Verifica-se a necessidade de avaliar, melhorar e implementar um padrão de referência para o processo de optimização, através de novos referenciais de boa prática ajustados aos sistemas digitais. Os parâmetros de exposição influenciam a dose no paciente, mas a percepção da qualidade de imagem digital não parece afectada com a variação da exposição. Os estudos que se realizaram envolvendo tanto imagens de fantomas como imagens de pacientes mostram que a sobreexposição é um risco potencial em radiologia digital. A avaliação da qualidade diagnóstica das imagens mostrou que com a variação da exposição não se observou degradação substancial da qualidade das imagens quando a redução de dose é efectuada. Propõe-se o estudo e a implementação de novos níveis de referência de diagnóstico ajustados aos sistemas de radiologia digital. Como contributo da tese, é proposto um modelo (STDI) para a optimização de sistemas de radiologia digital.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Na análise forense de explosivos é comum a tarefa de análise química num cenário de pós-explosão com o objectivo de detectar/identificar resíduos do explosivo usado. A maior dificuldade desta análise está directamente relacionada com os baixos teores de resíduos de explosivos que se encontram. Assim, é necessário que os diferentes passos aos quais as amostras são sujeitas, desde a sua recolha, acondicionamento e transporte, passando pela extracção no laboratório, até serem analisadas, sejam realizados com o maior controlo possível. Todas as tarefas envolvidas em todas as etapas poderão contribuir com erros que afectarão o resultado final. Deste modo, é da maior importância elaborar um programa de controlo da qualidade para que as análises sejam efectuadas de modo correcto, reprodutível e eficaz. Este trabalho consistiu na optimização e validação do desempenho qualitativo de um método de ensaio para detecção e identificação de quinze explosivos orgânicos através de cromatografia líquida de alto desempenho com um detector de ultravioleta-visível (HPLC-UV-Vis). De seguida estabeleceu-se um programa de controlo de qualidade (CQ) para ensaios em rotina, baseado nos resultados obtidos através da validação. Por fim, foi testado o referido programa com análises a diferentes amostras reais. De acordo com os resultados obtidos, o novo método de ensaio desenvolvido demonstrou ser um método mais rápido na análise de explosivos quando comparado com o anterior método. Portanto, é possível concluir que, através de testes estatísticos, ficou provado que o método é adequado para o fim a que se destina, podendo substituir com vantagens o método anteriormente utilizado em ensaios de rotina. Contudo, este método apresenta como principal desvantagem a dificuldade em separar compostos que apresentam isómeros. Esta é uma limitação menor que poderá ser estudada em trabalhos futuros.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A presente tese teve por objectivo principal o desenvolvimento de métodos que permitissem quantificar alguns aditivos HALS (Hindered Amine Ligth Stabilizers - Aminas Estericamente Impedidas Estabilizadoras à luz), tais como, Tinuvin 622®, Chimassorb 944® e Chimassorb 2020® presentes em amostras de corda sintética. Os métodos de quantificação compreenderam a hidrólise básica para o Tinuvin 622® e a hidrólise ácida para ambos os Chimassorbs, e a separação e identificação por HPLC-MS/MS dos produtos da mesma. Procedendo à realização do método com o respectivo padrão de cada aditivo foi possível obter-se uma curva de calibração para o Tinuvin 622® (y = 899733 X - 96173; r = 0,9979) e para o Chimassorb 944® (y = 44177 X - 18248; r = 0,9965). Relativamente ao Chimassorb 2020® foram realizados alguns ensaios preliminares fundamentais para o desenvolvimento de um método de quantificação para este aditivo. Para o Tinuvin 622® foram realizados ainda ensaios de forma a desenvolver-se um método em que a quantificação ocorresse exclusivamente pela separação do hidrolisado no HPLC com detector UV. Dado que o Tinuvin 622® não apresenta absorção no UV optou-se por realizar a derivatização fluorescente deste através da esterificação com PyCOOH (ácido pirenobutírico) em meio ácido. Nas amostras de corda foram realizados ensaios de envelhecimento e tracção, ensaios de brilho, ensaios de absorção, bem como a quantificação do Tinuvin 622® nas cordas com e sem tratamento de irradiação (envelhecimento). Comprovou-se que as amostras de corda contêm cerca de 0,2% de Tinuvin 622® e que a corda preta não contém aditivo HALS. Verificou-se que em cordas sujeitas à radiação UV, a tensão de ruptura é influenciada pela quantidade de Tinuvin 622® e que esta por sua vez depende do tempo de exposição a que a corda foi sujeita. Por outro lado, concluiu-se que a cor (pigmentos) e o brilho não apresentam influência significativa na resistência das cordas quando expostas à radiação UV.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

During the last two decades screen-film (SF) systems have been replaced by digital X-ray systems. The advent of digital technologies brought a number of digital solutions based on different detector and readout technologies. Improvements in technology allowed the development of new digital technologies for projection radiography such as computed radiography (CR) and digital radiography (DR). The large number of scientific papers concerning digital X-ray systems that have been published over the last 25 years indicates the relevance of these technologies in healthcare. There are important differences among different detector technologies that may affect system performance and image quality for diagnostic purposes. Radiographers are expected to have an effective understanding of digital X-ray technologies and a high level of knowledge and awareness concerning the capabilities of these systems. Patient safety and reliable diagnostic information are intrinsically linked to these factors. In this review article - which is the first of two parts - a global overview of the digital radiography systems (both CR and DR) currently available for clinical practice is provided.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Digital X-ray detector technologies provide several advantages when compared with screen-film (SF) systems: better diagnostic quality of the radiographic image, increased dose efficiency, better dynamic range and possible reduction of radiation exposure to the patient. The transition from traditional SF systems to digital technology-based systems highlights the importance of the discussion around technical factors such as image acquisition, themanagement of patient dose and diagnostic image quality. Radiographers should be aware of these aspects concerning their clinical practice regarding the advantages and limitations of digital detectors. Newdigital technologies require an up-to-date of scientific knowledge concerning their use in projection radiography. This is the second of a two-part review article focused on a technical overview of digital radiography detectors. This article provides a discussion about the issues related to the image acquisition requirements and advantages of digital technologies, the management of patient dose and the diagnostic image quality.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The spectral response and the photocurrent delivered by entirely microcrystalline p-i-n-Si:H detectors an analysed under different applied bias and light illumination conditions. The spectral response and the internal collection depend not only on the energy range but also on the illumination side. Under [p]- and [n]-side irradiation, the internal collection characteristics have an atypical shape. It is high for applied bias and lower than the open circuit voltage, shows a steep decrease near the open circuit voltage (higher under [n]-side illumination) and levels off for higher voltages. Additionally, the numerical modeling of the VIS/NIR detector, based on the band discontinuities near the grain boundaries and interfaces, complements the study and gives insight into the internal physical process.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

An optimized ZnO:Al/a-pin SixCl1-x:H/Al configuration for the laser scanned photodiode (LSP) imaging detector is proposed. The LSP utilizes light induced depletion layers as detector and a laser beam for readout. The effect of the sensing element structure, cell configuration and light source flux are investigated and correlated with the sensor output characteristics. Experimental data reveal that the large optical gap and the low conductivity of the doped a-SixC1-x:H layers are responsible by an induced inversion layer at the illuminated interfaces which blocks the carrier collection. These insulator-like layers act as MIS gates preventing image smearing. The physical background of the LSP is discussed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

An optimized ZnO:Al/a-pin SixC1-x:H/Al configuration for the laser scanned photodiode (LSP) imaging detector is proposed and the read-out parameters improved. The effect of the sensing element structure, cell configuration and light source flux are investigated and correlated with the sensor output characteristics. Data reveals that for sensors with wide band gap doped layers an increase on the image signal optimized to the blue is achieved with a dynamic range of two orders of magnitude, a responsivity of 6 mA W-1 and a sensitivity of 17 muW cm(-2) at 530 nm. The main output characteristics such as image responsivity, resolution, linearity and dynamic range were analyzed under reverse, forward and short circuit modes. The results show that the sensor performance can be optimized in short circuit mode. A trade-off between the scan time and the required resolution is needed since the spot size limits the resolution due to the cross-talk between dark and illuminated regions leading to blurring effects.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Large area n-i-p-n-i-p a-SiC:H heterostructures are used as sensing element in a double colour laser scanned photodiode image sensor (D/CLSP). This work aims to clarify possible improvements, physical limits and performance of CLSP image sensor when used as non-pixel image reader. Here, the image capture device and the scanning reader are optimized and the effects of the sensor structure on the output characteristics discussed. The role of the design of the sensing element, the doped layer composition and thickness, the read-out parameters (applied voltage and scanner frequency) on the image acquisition and the colour detection process are analysed. A physical model is presented and supported by a numerical simulation of the output characteristics of the sensor.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Large area n-i-p-n-i-p a-SiC:H heterostructures are used as sensing element in a Double Color Laser Scanned Photodiode image sensor (D/CLSP). This work aims to clarify possible improvements, physical limits and performance of CLSP image sensor when used as non-pixel image reader. Here, the image capture device and the scanning reader are optimized and the effects of the sensor structure on the output characteristics discussed. The role of the design of the sensing element, the doped layer composition and thickness, the read-out parameters (applied voltage and scanner frequency) on the image acquisition and the color detection process are analyzed. A physical model is presented and supported by a numerical simulation of the output characteristics of the sensor.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We discuss the operation of a new type of optical sensor (MISCam) based on a metal-insulator-semiconductor (MIS) structure. The operation principle relies on light-induced changes of the band bending and barrier height at the interface between semiconductor and insulator. An image is obtained from the quenching of the ac signal in analogy to the principle of the laser-scanned photodiode (LSP). Lateral resolution depends on the semiconductor material chosen. We have characterised the MIS structures by C-V, I-V, and spectral response measurements testing different types of insulators like a-Si3N4, SiO2, and AlN. The presence of slow interface charges allows for image memory. Colour sensors can be realised by controlling sign and magnitude of the electric fields in the base and the interface region.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introdução – A monitorização da exposição ocupacional a doses de radiação ionizante pode ser complementada por dosímetros eletrónicos individuais que permitem uma leitura direta da dose de radiação recebida. Dada a dependência energética e de débito de dose já reportada para estes dosímetros, este trabalho pretende determinar a linearidade da resposta de um dosímetro eletrónico individual e estudar o comportamento da sua resposta em função da energia de radiação e do débito de dose. Metodologia – Para estudar a dependência da energia da radiação do dosímetro eletrónico pessoal Vertec Bleeper Sv procedeu‑se à sua irradiação com um equivalente de dose individual, Hp(10), de 500 μSv de radiação gama do Cobalto – 60 (60C) e Césio – 137 (137Cs) e das qualidades de radiação X da série Narrow (N): N‑30, N‑40, N‑60, N‑80, N‑100 e N‑120. Para investigar a dependência da resposta em função do débito de dose aplicaram‑se à ampola de raios X as intensidades de corrente elétrica de 1 mA, 5 mA, 10 mA, 15 mA e 20 mA. Resultados – Não existe uma relação entre a resposta do detetor e a energia de radiação a que este é exposto. Ocorre uma subestimação superior a 50% na grandeza medida para energias inferiores a 33 keV, mas ostenta uma medida relativamente linear da grandeza Hp(10) para doses inferiores a 100 μSv. Também se constata que, à medida que o débito de dose aumenta, existe uma diminuição na resposta do dosímetro. O menor decréscimo na resposta deste dosímetro eletrónico individual dá‑se para as qualidades de radiação N‑30 (1,1%), N‑40 (4,1%) e N‑120 (20,0%). Conclusão – Verifica‑se que a resposta do dosímetro individual Vertec Bleeper Sv depende fortemente da energia da radiação e do débito de dose. ABSTRACT: Introduction – The measurement of occupational exposure to radiation doses can be completed with an electronic personal dosemeter that allows a direct reading and alarm function of the received radiation dose. Due to the energy and dose rate dependence already reported for this type of dosemeter, it is intended, with this work, to determine the response linearity of an Electronic Personal Dosemeter and to study its response behavior to the dose rate and radiation energy. Methodology – The electronic personal dosemeter Vertec Bleeper Sv energy dependency was evaluated by its irradiation with 500 μSv from the radionuclides Cobalt – 60 (60C) and Cesium – 137 (137Cs) as well as by the radiation qualities of the Narrow (N) series: N‑30, N‑40, N‑60, N‑80, N‑100 e N‑120. To investigate the dose rate dependency, the intensities of electric current of 1 mA, 5 mA, 10 mA, 15 mA and 20 mA were applied to the X‑ray tube. Results – There is no relationship between the response of the detector and the radiation energy. For energies below 33 keV there is an underestimation over 50% of the radiation dose measured but the detector presents a linear response for energies under 100 μSv. A dependency on the dose rate is perceived since as the dose rate increases, the response of the individual monitor decreases. There is a smaller decrease for the radiation qualities of N‑30 (1.1%), N‑40 (4.1%) and N‑120 (20.0%). Conclusion – It is concluded that there is a strong dependence of radiation energy and dose rate on the response of an electronic personal dosemeter.