51 resultados para Digital communication systems
em Repositório Científico do Instituto Politécnico de Lisboa - Portugal
Resumo:
Advances in digital technology led to the development of digital x-ray detectors that are currently in wide use for projection radiography, including Computed Radiography (CR) and Digital Radiography (DR). Digital Imaging Systems for Plain Radiography addresses the current technological methods available to medical imaging professionals to ensure the optimization of the radiological process concerning image quality and reduction of patient exposure. Based on extensive research by the authors and reference to the current literature, the book addresses how exposure parameters influence the diagnostic quality in digital systems, what the current acceptable radiation doses are for useful diagnostic images, and at what level the dose could be reduced to maintain an accurate diagnosis. The book is a valuable resource for both students learning the field and for imaging professionals to apply to their own practice while performing radiological examinations with digital systems.
Resumo:
Plain radiography still accounts for the vast majority of imaging studies that are performed at multiple clinical instances. Digital detectors are now prominent in many imaging facilities and they are the main driving force towards filmless environments. There has been a working paradigm shift due to the functional separation of acquisition, visualization, and storage with deep impact in the imaging workflows. Moreover with direct digital detectors images are made available almost immediately. Digital radiology is now completely integrated in Picture Archiving and Communication System (PACS) environments governed by the Digital Imaging and Communications in Medicine (DICOM) standard. In this chapter a brief overview of PACS architectures and components is presented together with a necessarily brief account of the DICOM standard. Special focus is given to the DICOM digital radiology objects and how specific attributes may now be used to improve and increase the metadata repository associated with image data. Regular scrutiny of the metadata repository may serve as a valuable tool for improved, cost-effective, and multidimensional quality control procedures.
Resumo:
Esta tese pretende contribuir para o estudo e análise dos factores relacionados com as técnicas de aquisição de imagens radiológicas digitais, a qualidade diagnóstica e a gestão da dose de radiação em sistema de radiologia digital. A metodologia encontra-se organizada em duas componentes. A componente observacional, baseada num desenho do estudo de natureza retrospectiva e transversal. Os dados recolhidos a partir de sistemas CR e DR permitiram a avaliação dos parâmetros técnicos de exposição utilizados em radiologia digital, a avaliação da dose absorvida e o índice de exposição no detector. No contexto desta classificação metodológica (retrospectiva e transversal), também foi possível desenvolver estudos da qualidade diagnóstica em sistemas digitais: estudos de observadores a partir de imagens arquivadas no sistema PACS. A componente experimental da tese baseou-se na realização de experiências em fantomas para avaliar a relação entre dose e qualidade de imagem. As experiências efectuadas permitiram caracterizar as propriedades físicas dos sistemas de radiologia digital, através da manipulação das variáveis relacionadas com os parâmetros de exposição e a avaliação da influência destas na dose e na qualidade da imagem. Utilizando um fantoma contraste de detalhe, fantomas antropomórficos e um fantoma de osso animal, foi possível objectivar medidas de quantificação da qualidade diagnóstica e medidas de detectabilidade de objectos. Da investigação efectuada, foi possível salientar algumas conclusões. As medidas quantitativas referentes à performance dos detectores são a base do processo de optimização, permitindo a medição e a determinação dos parâmetros físicos dos sistemas de radiologia digital. Os parâmetros de exposição utilizados na prática clínica mostram que a prática não está em conformidade com o referencial Europeu. Verifica-se a necessidade de avaliar, melhorar e implementar um padrão de referência para o processo de optimização, através de novos referenciais de boa prática ajustados aos sistemas digitais. Os parâmetros de exposição influenciam a dose no paciente, mas a percepção da qualidade de imagem digital não parece afectada com a variação da exposição. Os estudos que se realizaram envolvendo tanto imagens de fantomas como imagens de pacientes mostram que a sobreexposição é um risco potencial em radiologia digital. A avaliação da qualidade diagnóstica das imagens mostrou que com a variação da exposição não se observou degradação substancial da qualidade das imagens quando a redução de dose é efectuada. Propõe-se o estudo e a implementação de novos níveis de referência de diagnóstico ajustados aos sistemas de radiologia digital. Como contributo da tese, é proposto um modelo (STDI) para a optimização de sistemas de radiologia digital.
Resumo:
The assessment of patient dose has gained increased attention, still being an issue of concern that arises from the use of digital systems. The development of digital technology offers the possibility for a reduction of radiation dose around 50% without loss in image quality when compared to a conventional screen–film system. Digital systems give an equivalent or superior diagnostic performance and also several other advantages, but the risk of overexposure with no adverse effect on image quality could be present. This chapter refers to the management of patient dose and provides an explanation of dose-related concepts. In this chapter, exposure influence in dose and image representation and the effects of radiation exposure are also discussed.
Resumo:
During the last two decades screen-film (SF) systems have been replaced by digital X-ray systems. The advent of digital technologies brought a number of digital solutions based on different detector and readout technologies. Improvements in technology allowed the development of new digital technologies for projection radiography such as computed radiography (CR) and digital radiography (DR). The large number of scientific papers concerning digital X-ray systems that have been published over the last 25 years indicates the relevance of these technologies in healthcare. There are important differences among different detector technologies that may affect system performance and image quality for diagnostic purposes. Radiographers are expected to have an effective understanding of digital X-ray technologies and a high level of knowledge and awareness concerning the capabilities of these systems. Patient safety and reliable diagnostic information are intrinsically linked to these factors. In this review article - which is the first of two parts - a global overview of the digital radiography systems (both CR and DR) currently available for clinical practice is provided.
Resumo:
Developments in digital detector technologies have been taking place and new digital technologies are available for clinical practice. This chapter is intended to give a technical state-of-the-art overview about computed radiography (CR) and digital radiography (DR) detectors. CR systems use storage-phosphor image plates with a separate image readout process and DR technology converts X-rays into electrical charges by means of a readout process using TFT arrays. Digital detectors offer several advantages when compared to analogue detectors. The knowledge about digital detector technology for use in plain radiograph examinations is thus a fundamental topic to be acquired by radiology professionals and students. In this chapter an overview of digital radiography systems (both CR and DR) currently available for clinical practice is provided.
Resumo:
The characterization of physical properties of digital imaging systems requires the determination and measurement of detectors’ physical performance. Those measures such as modulation transfer function (MTF), noise power spectra (NPS), and detective quantum efficiency (DQE) provide objective evaluations of digital detectors’ performance. To provide an MTF, NPS, and DQE calculation from raw-data images it is necessary to implement a method that is undertaken by two major steps: (1) image acquisition and (2) quantitative measure determination method. In this chapter a comprehensive description about a method to provide the measure of performance of digital radiography detectors is provided.
Resumo:
This chapter addresses technical issues concerning digital technologies. Radiological equipment and technique are briefly introduced together with a discussion about requirements and advantages of digital technologies. Digital technologies offer several advantages when compared to conventional analogical systems, or screen–film (SF) systems. While in clinical practice the practitioners should be aware of technical factors such as image acquisition, management of patient dose, and diagnostic image quality. Thus, digital technologies require an up-to-date scientific knowledge concerning their use in projection radiography. In this chapter, technical considerations concerning digital technologies are provided.
Resumo:
Digital radiography detectors—based on different technological solutions—are currently available for clinical applications and widespread in clinical practice. Computed radiography (CR) and digital radiology systems have been available for clinical applications and the trend over the last few years has become digital. Radiology departments have been changing from traditional screen–film technology to digital technology. This chapter is intended to give the reader a practical understanding about the key aspects concerning digital systems, related to the performance of different technologies, image quality, and dose and patient safety/protection. The discussion around an optimization framework for digital systems is provided.
Resumo:
Once in a digital form, a radiographic image may be processed in several ways in order to turn the visualization an act of improved diagnostic value. Practitioners should be aware that, depending on each clinical context, digital image processing techniques are available to help to unveil visual information that is, in fact, carried by the bare digital radiograph and may be otherwise neglected. The range of visual enhancement procedures includes simple techniques that deal with the usual brightness and contrast manipulation up to much more elaborate multi-scale processing that provides customized control over the emphasis given to the relevant finer anatomical details. This chapter is intended to give the reader a practical understanding of image enhancement techniques that might be helpful to improve the visual quality of the digital radiographs and thus to contribute to a more reliable and assertive reporting.
Resumo:
Dissertação apresentada à Escola Superior de Comunicação Social como parte dos requisitos para obtenção de grau de mestre em Gestão Estratégica das Relações Públicas.
Resumo:
Amorphous SiC heterostructures built as a double pin device has a non linear spectral gain which is a function of the signal wavelength that impinges on its front or back surface. Illuminating the device with several single wavelength data channels in the visible spectrum allows for Wavelength Division Multiplexing (WDM) digital communication. Using fixed ultra-violet illumination at the front or back surfaces enables the recovery of the multiplexed channels. Five channels, each using a single wavelength which is modulated by a Manchester coded signal at 12,000 bps, form a frame with 1024 bits with a preamble for signal intensity and synchronisation purposes. Results show that the clustering of the received signal enables the successful recovery of the five channel data using the front and back illumination of the surfaces of the double pin photo device. (C) 2015 Elsevier B.V. All rights reserved.
Resumo:
The big proliferation of mobile communication systems has caused an increased concern about the interaction between the human body and the antennas of mobile handsets. In order to study the problem, a multiband antenna was designed, fabricated and measured to operate over two frequency sub bands 900 and 1800 MHz. After that, we simulated the same antenna, but now, in the presence of a human head model to analyze the head's influence. First, the influence of the human head on the radiation efficiency of the antenna has been investigated as a function of the distance between the head and the antenna and with the inclination of the antenna. Furthermore, the relative amount of the electromagnetic power absorbed in the head has been obtained.
Resumo:
The big proliferation of mobile communication systems has caused an increased concern about the interaction between the human body and the antennas of mobile handsets. In order to study the problem, a multiband antenna was designed, fabricated and measured to operate over two frequency sub bands 900 and 1800 MHz. After that, we simulated the same antenna, but now, in the presence of a human head model to analyze the head's influence. First, the influence of the human head on the radiation efficiency of the antenna has been investigated as a function of the distance between the head and the antenna and with the inclination of the antenna. Furthermore, the relative amount of the electromagnetic power absorbed in the head has been obtained. In this study the electromagnetic analysis has been performed via FDTD (Finite Difference Time Domain).
Resumo:
Este estudo tem por objectivos determinar a Dose Glandular Média - Mean Glandular Dose (MGD) - em 3 sistemas de Mamografia e comparar os valores obtidos com os referenciais internacionais. O estudo foi realizado num sistema analógico de Écran-Película (EP) e em dois sistemas de imagem digital (CR e DR). Foi efectuado o cálculo da Entrance Surface Air Kerma (ESAK) e da MGD em três equipamentos a partir de uma amostra de dados referentes a 30 mulheres assintomáticas, com idades compreendidas entre os 40 e 64 anos. Em cada equipamento objecto de análise, foram recolhidos os dados referentes a 10 mulheres. Foram consideradas as projecções crânio-caudal (CC) e oblíqua médio-lateral (MLO). A análise de resultados revelou que o valor de MGD varia quando se compara os três sistemas. Nas incidências CC os valores de MGD obtidos foram de 1,54 mGy (EP), 1,78 mGy (CR) e 0,82 mGy (DR). Nas incidências MLO o valor de MGD foi de 1,53 mGy no sistema EP, de 1,78 mGy no CR e 0,87 mGy no sistema DR. Constata-se que o valor de MGD na incidência de CC é inferior ao valor de MGD na incidência MLO, excepto para o sistema EP. Verifica-se também que o sistema EP apresenta maior variabilidade nos dados de MGD comparativamente com os restantes sistemas. O sistema DR é o que apresenta a menor variabilidade de valores MGD e também valores de MGD mais baixos. Comparando os resultados deste estudo com as referências internacionais, verifica-se que a MGD se encontra abaixo do limite de 2 mGy recomendado. ABSTRACT - This study aims to estimate the Mean Glandular Dose (MGD) associated with three different mammographic systems and compare the results with recommended international reference values. The systems included in the study included a conventional Screen-Film (SF) system and two digital mammography systems (CR and DR). Entrance Surface Air Kerma (ESAK) and MGD associated with each equipment were calculated. A sample of 30 healthy women (age ranging from 40 to 64 years old) undertaking screening mammography was considered in this study. The mammographic exam includes two projections, cranio-caudal (CC) and medio-lateral oblique (MLO). The MGD results obtained for CC projection were 1,54 mGy (SF), 1,78 mGy (CR) and 0,82 mGy (DR). MGD values for the MLO projection were 1,53 mGy (SF), 1,78 mGy (CR) and 0,87 mGy (DR). Results show that MGD value is slightly lower in the CC projection than in MLO, except for the SF system (1,54 mGy; 1,53 mGy). In addition the MGD for the SF system varied more than that associated with the digital systems. The DR system allows a narrow variation of MGD values and also lower MGD values. Comparing this study results with the international references we concluded that MGD values are below the 2 mGy recommended value for the three systems evaluated.