5 resultados para Conventional methods
em Repositório Científico do Instituto Politécnico de Lisboa - Portugal
Resumo:
Cork oak is the second most dominant forest species in Portugal and makes this country the world leader in cork export. Occupational exposure to Chrysonilia sitophila and the Penicillium glabrum complex in cork industry is common, and the latter fungus is associated with suberosis. However, as conventional methods seem to underestimate its presence in occupational environments, the aim of our study was to see whether information obtained by polymerase chain reaction (PCR), a molecular-based method, can complement conventional findings and give a better insight into occupational exposure of cork industry workers. We assessed fungal contamination with the P. glabrum complex in three cork manufacturing plants in the outskirts of Lisbon using both conventional and molecular methods. Conventional culturing failed to detect the fungus at six sampling sites in which PCR did detect it. This confirms our assumption that the use of complementing methods can provide information for a more accurate assessment of occupational exposure to the P. glabrum complex in cork industry.
Resumo:
The presence of filamentous fungi was detected in wastewater and air collected at wastewater treatment plants (WWTP) from several European countries. The aim of the present study was to assess fungal contamination in two WWTP operating in Lisbon. In addition, particulate matter (PM) contamination data was analyzed. To apply conventional methods, air samples from the two plants were collected through impaction using an air sampler with a velocity air rate of 140 L/min. Surfaces samples were collected by swabbing the surfaces of the same indoor sites. All collected samples were incubated at 27°C for 5 to 7 d. After lab processing and incubation of collected samples, quantitative and qualitative results were obtained with identification of the isolated fungal species. For molecular methods, air samples of 250 L were also collected using the impinger method at 300 L/min airflow rate. Samples were collected into 10 ml sterile phosphate-buffered saline with 0.05% Triton X-100, and the collection liquid was subsequently used for DNA extraction. Molecular identification of Aspergillus fumigatus and Stachybotrys chartarum was achieved by real-time polymerase chain reaction (RT-PCR) using the Rotor-Gene 6000 qPCR Detection System (Corbett). Assessment of PM was also conducted with portable direct-reading equipment (Lighthouse, model 3016 IAQ). Particles concentration measurement was performed at five different sizes: PM0.5, PM1, PM2.5, PM5, and PM10. Sixteen different fungal species were detected in indoor air in a total of 5400 isolates in both plants. Penicillium sp. was the most frequently isolated fungal genus (58.9%), followed by Aspergillus sp. (21.2%) and Acremonium sp. (8.2%), in the total underground area. In a partially underground plant, Penicillium sp. (39.5%) was also the most frequently isolated, also followed by Aspergillus sp. (38.7%) and Acremonium sp. (9.7%). Using RT-PCR, only A. fumigatus was detected in air samples collected, and only from partial underground plant. Stachybotrys chartarum was not detected in any of the samples analyzed. The distribution of particle sizes showed the same tendency in both plants; however, the partially underground plant presented higher levels of contamination, except for PM2.5. Fungal contamination assessment is crucial to evaluating the potential health risks to exposed workers in these settings. In order to achieve an evaluation of potential health risks to exposed workers, it is essential to combine conventional and molecular methods for fungal detection. Protective measures to minimize worker exposure to fungi need to be adopted since wastewater is the predominant internal fungal source in this setting.
Resumo:
Dissertação para obtenção do grau de Mestre em Engenharia Electrotécnica Ramo de Energia
Resumo:
Although a clear correlation between levels of fungi in the air and health impacts has not been shown in epidemiological studies, fungi must be regarded as potential occupational health hazards. Fungi can have an impact on human health in four different ways: (1) they can infect humans, (2) they may act as allergens, (3) they can be toxigenic, or (4) they may cause inflammatory reactions. Fungi of concern in occupational hygiene are mostly non-pathogenic or facultative pathogenic (opportunistic) species, but are relevant as allergens and mycotoxins producers. It is known that the exclusive use of conventional methods for fungal quantification (fungal culture) may underestimate the results due to different reasons. The incubation temperature chosen will not be the most suitable for every fungal species, resulting in the inhibition of some species and the favouring of others. Differences in fungi growth rates may also result in data underestimation, since the fungal species with higher growth rates may inhibit others species’ growth. Finally, underestimated data can result from non-viable fungal particles that may have been collected or fungal species that do not grow in the culture media used, although these species may have clinical relevance in the context. Due to these constraints occupational exposure assessment, in setings with high fungal contamination levels, should follow these steps: Apply conventional methods to obtain fungal load information (air and surfaces) regarding the most critical scenario previously selected; Guideline comparation aplying or legal requirements or suggested limits by scientific and/or technical organizations. We should also compare our results with others from the same setting (if there is any); Select the most suitable indicators for each setting and apply conventional-culture methods and also molecular tools. These methodology will ensure a more real characterization of fungal burden in each setting and, consequently, permits to identify further measures regarding assessment of fungal metabolites, and also a more adequate workers health surveillance. The methodology applied to characterize fungal burden in several occupational environments, focused in Aspergillus spp. prevalence, will be present and discussed.
Resumo:
In Czech schools two teaching methods of reading are used: the analytic-synthetic (conventional) and genetic (created in the 1990s). They differ in theoretical foundations and in methodology. The aim of this paper is to describe the above mentioned theoretical approaches and present the results of study that followed the differences in the development of initial reading skills between these methods. A total of 452 first grade children (age 6-8) were assessed by a battery of reading tests at the beginning and at the end of the first grade and at the beginning of the second grade. 350 pupils participated all three times. Based on data analysis the developmental dynamics of reading skills in both methods and the main differences in several aspects of reading abilities (e.g. the speed of reading, reading technique, error rate in reading) are described. The main focus is on the reading comprehension development. Results show that pupils instructed using genetic approach scored significantly better on used reading comprehension tests, especially in the first grade. Statistically significant differences occurred between classes independently of each method. Therefore, other factors such as teacher´s role and class composition are discussed.