13 resultados para Code validation
em Repositório Científico do Instituto Politécnico de Lisboa - Portugal
Resumo:
Purpose: The most recent Varian® micro multileaf collimator(MLC), the High Definition (HD120) MLC, was modeled using the BEAMNRCMonte Carlo code. This model was incorporated into a Varian medical linear accelerator, for a 6 MV beam, in static and dynamic mode. The model was validated by comparing simulated profiles with measurements. Methods: The Varian® Trilogy® (2300C/D) accelerator model was accurately implemented using the state-of-the-art Monte Carlo simulation program BEAMNRC and validated against off-axis and depth dose profiles measured using ionization chambers, by adjusting the energy and the full width at half maximum (FWHM) of the initial electron beam. The HD120 MLC was modeled by developing a new BEAMNRC component module (CM), designated HDMLC, adapting the available DYNVMLC CM and incorporating the specific characteristics of this new micro MLC. The leaf dimensions were provided by the manufacturer. The geometry was visualized by tracing particles through the CM and recording their position when a leaf boundary is crossed. The leaf material density and abutting air gap between leaves were adjusted in order to obtain a good agreement between the simulated leakage profiles and EBT2 film measurements performed in a solid water phantom. To validate the HDMLC implementation, additional MLC static patterns were also simulated and compared to additional measurements. Furthermore, the ability to simulate dynamic MLC fields was implemented in the HDMLC CM. The simulation results of these fields were compared with EBT2 film measurements performed in a solid water phantom. Results: Overall, the discrepancies, with and without MLC, between the opened field simulations and the measurements using ionization chambers in a water phantom, for the off-axis profiles are below 2% and in depth-dose profiles are below 2% after the maximum dose depth and below 4% in the build-up region. On the conditions of these simulations, this tungsten-based MLC has a density of 18.7 g cm− 3 and an overall leakage of about 1.1 ± 0.03%. The discrepancies between the film measured and simulated closed and blocked fields are below 2% and 8%, respectively. Other measurements were performed for alternated leaf patterns and the agreement is satisfactory (to within 4%). The dynamic mode for this MLC was implemented and the discrepancies between film measurements and simulations are within 4%. Conclusions: The Varian® Trilogy® (2300 C/D) linear accelerator including the HD120 MLC was successfully modeled and simulated using the Monte CarloBEAMNRC code by developing an independent CM, the HDMLC CM, either in static and dynamic modes.
Resumo:
One of the major problems that prevents the spread of elections with the possibility of remote voting over electronic networks, also called Internet Voting, is the use of unreliable client platforms, such as the voter's computer and the Internet infrastructure connecting it to the election server. A computer connected to the Internet is exposed to viruses, worms, Trojans, spyware, malware and other threats that can compromise the election's integrity. For instance, it is possible to write a virus that changes the voter's vote to a predetermined vote on election's day. Another possible attack is the creation of a fake election web site where the voter uses a malicious vote program on the web site that manipulates the voter's vote (phishing/pharming attack). Such attacks may not disturb the election protocol, therefore can remain undetected in the eyes of the election auditors. We propose the use of Code Voting to overcome insecurity of the client platform. Code Voting consists in creating a secure communication channel to communicate the voter's vote between the voter and a trusted component attached to the voter's computer. Consequently, no one controlling the voter's computer can change the his/her's vote. The trusted component can then process the vote according to a cryptographic voting protocol to enable cryptographic verification at the server's side.
Resumo:
O objectivo deste trabalho passa pelo desenvolvimento de uma ferramenta de simulação dinâmica de recursos rádio em LTE no sentido descendente, com recurso à Framework OMNeT++. A ferramenta desenvolvida permite realizar o planeamento das estações base, simulação e análise de resultados. São descritos os principais aspectos da tecnologia de acesso rádio, designadamente a arquitectura da rede, a codificação, definição dos recursos rádio, os ritmos de transmissão suportados ao nível de canal e o mecanismo de controlo de admissão. Foi definido o cenário de utilização de recursos rádio que inclui a definição de modelos de tráfego e de serviços orientados a pacotes e circuitos. Foi ainda considerado um cenário de referência para a verificação e validação do modelo de simulação. A simulação efectua-se ao nível de sistema, suportada por um modelo dinâmico, estocástico e orientado por eventos discretos de modo a contemplar os diferentes mecanismos característicos da tecnologia OFDMA. Os resultados obtidos permitem a análise de desempenho dos serviços, estações base e sistema ao nível do throughput médio da rede, throughput médio por eNodeB e throughput médio por móvel para além de permitir analisar o contributo de outros parâmetros designadamente, largura de banda, raio de cobertura, perfil dos serviços, esquema de modulação, entre outros. Dos resultados obtidos foi possível verificar que, considerando um cenário com estações base com raio de cobertura de 100 m obteve-se um throughput ao nível do utilizador final igual a 4.69494 Mbps, ou seja, 7 vezes superior quando comparado a estações base com raios de cobertura de 200m.
Resumo:
The importance of Social Responsibility (SR) is higher if this business variable is related with other ones of strategic nature in business activity (competitive success that the company achieved, performance that the firms develop and innovations that they carries out). The hypothesis is that organizations that focus on SR are those who get higher outputs and innovate more, achieving greater competitive success. A scale for measuring the orientation to SR has defined in order to determine the degree of relationship between above elements. This instrument is original because previous scales do not exist in the literature which could measure, on the one hand, the three classics sub-constructs theoretically accepted that SR is made up and, on the other hand, the relationship between SR and the other variables. As a result of causal relationships analysis we conclude with a scale of 21 indicators, validated scale with a sample of firms belonging to the Autonomous Community of Extremadura and it is the first empirical validation of these dimensions we know so far, in this context.
Resumo:
Screening programs, particularly the inclusion of specific orthoptic tests to detect visual abnormalities, varies among countries. This study aims to: 1) describes expert perception of issues related with children visual screening; 2) identify specific orthoptic tests to detect visual abnormalities in children visual screening.
Resumo:
Low-density parity-check (LDPC) codes are nowadays one of the hottest topics in coding theory, notably due to their advantages in terms of bit error rate performance and low complexity. In order to exploit the potential of the Wyner-Ziv coding paradigm, practical distributed video coding (DVC) schemes should use powerful error correcting codes with near-capacity performance. In this paper, new ways to design LDPC codes for the DVC paradigm are proposed and studied. The new LDPC solutions rely on merging parity-check nodes, which corresponds to reduce the number of rows in the parity-check matrix. This allows to change gracefully the compression ratio of the source (DCT coefficient bitplane) according to the correlation between the original and the side information. The proposed LDPC codes reach a good performance for a wide range of source correlations and achieve a better RD performance when compared to the popular turbo codes.
Resumo:
GimC/Prefoldin is a hetero-oligomeric complex involved in cytoskeleton biogenesis. In order to identify by two-hybrid system targets that directly interact with Gims and support the stress phenotypes, this work aimed the functional validation of all Gims in saccharomyces cerevisiae.
Resumo:
Dissertação de natureza científica para obtenção do grau de Mestre em Engenharia Informática e de Computadores
Resumo:
Purpose - To develop and validate a psychometric scale for assessing image quality perception for chest X-ray images. Methods - Bandura's theory was used to guide scale development. A review of the literature was undertaken to identify items/factors which could be used to evaluate image quality using a perceptual approach. A draft scale was then created (22 items) and presented to a focus group (student and qualified radiographers). Within the focus group the draft scale was discussed and modified. A series of seven postero-anterior chest images were generated using a phantom with a range of image qualities. Image quality perception was confirmed for the seven images using signal-to-noise ratio (SNR 17.2–36.5). Participants (student and qualified radiographers and radiology trainees) were then invited to independently score each of the seven images using the draft image quality perception scale. Cronbach alpha was used to test interval reliability. Results - Fifty three participants used the scale to grade image quality perception on each of the seven images. Aggregated mean scale score increased with increasing SNR from 42.1 to 87.7 (r = 0.98, P < 0.001). For each of the 22 individual scale items there was clear differentiation of low, mid and high quality images. A Cronbach alpha coefficient of >0.7 was obtained across each of the seven images. Conclusion - This study represents the first development of a chest image quality perception scale based on Bandura's theory. There was excellent correlation between the image quality perception scores derived using the scale and the SNR. Further research will involve a more detailed item and factor analysis.
Resumo:
The DatScanTM and its Semiquantification (SQ) can provide advantages in the diagnosis of Parkinsonian Syndromes (PS). To improve the SQ is recommended the creation of adapted database (DB) with reference values for the Nuclear Medicine Departments. Previously to this work was created a adapted database (DBRV) to Nuclear Medicine Department's protocol and population of Infanta Cristina's Hospital located in Badajoz, for patients between the ages of 60 and 75, and reference values of the SQ were calculated. Aim: To evaluate the discrimination capacity of a department's adapted DB reference's values of healthy controls for DatScanTM.
Resumo:
Purpose - To develop and validate a psychometric scale for assessing image quality for chest radiographs.
Resumo:
Trabalho de Projeto para obtenção do grau de Mestre em Engenharia Civil
Resumo:
This paper proposes the concept of multi-asynchronous-channel for Petri nets. Petri nets extended with multi-asynchronous-channels and time-domains support the specification of distributed controllers, where each controller has a synchronous execution but the global system is asynchronous (globally-asynchronous locally-synchronous systems). Each multi-asynchronous-channel specify the interaction between two or more distributed controllers. These channels, together with the time-domain concept, ensure the creation of network-independent models to support implementations using heterogeneous communication networks. The created models support not only the systems documentation but also their validation and implementation through simulation tools, verification tools, and automatic code generators. An application example illustrates the use of a Petri net class extended with the proposed channels. © 2015 IEEE.