7 resultados para Circuit City

em Repositório Científico do Instituto Politécnico de Lisboa - Portugal


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The intensive use of semiconductor devices enabled the development of a repetitive high-voltage pulse-generator topology from the dc voltage-multiplier (VM) concept. The proposed circuit is based on an odd VM-type circuit, where a number of dc capacitors share a common connection with different voltage ratings in each one, and the output voltage comes from a single capacitor. Standard VM rectifier and coupling diodes are used for charging the energy-storing capacitors, from an ac power supply, and two additional on/off semiconductors in each stage, to switch from the typical charging VM mode to a pulse mode with the dc energy-storing capacitors connected in series with the load. Results from a 2-kV experimental prototype with three stages, delivering a 10-mu s pulse with a 5-kHz repetition rate into a resistive load, are discussed. Additionally, the proposed circuit is compared against the solid-state Marx generator topology for the same peak input and output voltages.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Vários estudos demonstraram que os doentes com insuficiência cardíaca congestiva (ICC) têm um compromisso da qualidade de vida relacionada com a saúde (QVRS), tendo esta, nos últimos anos, vindo a tornar-se um endpoint primário quando se analisa o impacto do tratamento de situações crónicas como a ICC. Objectivos: Avaliar as propriedades psicométricas da versão portuguesa de um novo instrumento específico para medir a QVRS na ICC em doentes hospitalizados: o Kansas City Cardiomyopathy Questionnaire (KCCQ). População e Métodos: O KCCQ foi aplicado a uma amostra consecutiva de 193 doentes internados por ICC. Destes, 105 repetiram esta avaliação 3 meses após admissão hospitalar, não havendo eventos ocorridos durante este período de tempo. A idade era 64,4± 12,4 anos (entre 21 e 88), com 72,5% a pertencer ao sexo masculino, sendo a ICC de etiologia isquémica em 42%. Resultados: Esta versão do KCCQ foi sujeita a validação estatística semelhante à americana com a avaliação da fidelidade e validade. A fidelidade foi avaliada pela consistência interna dos domínios e dos somatórios, apresentando valores Alpha de Cronbach idênticos nos vários domínios e somatórios ( =0,50 a =0,94). A validade foi analisada pela convergência, pela sensibilidade às diferenças entre grupos e pela sensibilidade à alteração da condição clínica. Avaliou-se a validade convergente de todos os domínios relacionados com funcionalidade, pela relação verificada entre estes e uma medida de funcionalidade, a classificação da New York Heart Association (NYHA), tendo-se verificado correlações significativas (p<0,01), como medida para avaliar a funcionalidade em doentes com ICC. Efectuou-se uma análise de variância entre o domínio limitação física, os somatórios e as classes da NYHA, tendo-se encontrado diferenças estatisticamente significativas (F=23,4; F=36,4; F=37,4; p=0,0001), na capacidade de descriminação da gravidade da condição clínica. Foi realizada uma segunda avaliação em 105 doentes na consulta do 3º mês após a intervenção clínica, tendo-se observado alterações significativas nas médias dos domínios avaliados entre o internamento e a consulta (diferenças de 14,9 a 30,6 numa escala de 0-100), indicando que os domínios avaliados são sensíveis à mudança da condição clínica. A correlação interdimensões da qualidade de vida que compõe este instrumento é moderada, sugerindo dimensões independentes, apoiando a sua estrutura multifactorial e a adequabilidade desta medida para a sua avaliação. Conclusão: O KCCQ é um instrumento válido, sensível à mudança e específico para medir a QVRS numa população portuguesa com miocardiopatia dilatada e ICC. ABSTRACT - Several studies have shown that patients with congestive heart failure (CHF) have a compromised health-related quality of life (HRQL), and this, in recent years, has become a primary endpoint when considering the impact of treatment of chronic conditions such as CHF. Objectives: To evaluate the psychometric properties of the Portuguese version of a new specific instrument to measure HRQL in patients hospitalized for CHF: the Kansas City Cardiomyopathy Questionnaire (KCCQ). Methods: The KCCQ was applied to a sample of 193 consecutive patients hospitalized for CHF. Of these, 105 repeated the assessment 3 months after admission, with no events during this period. Mean age was 64.4±12.4 years (21-88), and 72.5% were 72.5% male. CHF was of ischemic etiology in 42% of cases. Results: This version of the KCCQ was subjected to statistical validation, with assessment of reliability and validity, similar to the American version. Reliability was assessed by the internal consistency of the domains and summary scores, which showed similar values of Cronbach alpha (0.50-0.94). Validity was assessed by convergence, sensitivity to differences between groups and sensitivity to changes in clinical condition. We evaluated the convergent validity of all domains related to functionality, through the relationship between them and a measure of functionality, the New York Heart Association (NYHA) classification. Significant correlations were found (p<0.01) for this measure of functionality in patients with CHF. Analysis of variance between the physical limitation domain, the summary scores and NYHA class was performed and statistically significant differences were found (F=23.4; F=36.4; F=37.4, p=0.0001) in the ability to discriminate severity of clinical condition. A second evaluation was performed on 105 patients at the 3-month follow-up outpatient appointment, and significant changes were observed in the mean scores of the domains assessed between hospital admission and the clinic appointment (differences from 14.9 to 30.6 on a scale of 0-100), indicating that the domains assessed are sensitive to changes in clinical condition. The correlation between dimensions of quality of life in the KCCQ is moderate, suggesting that the dimensions are independent, supporting the multifactorial nature of HRQL and the suitability of this measure for its evaluation. Conclusion: The KCCQ is a valid instrument, sensitive to change and a specific measure of HRQL in a population with dilated cardiomyopathy and CHF.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Characteristics of tunable wavelength filters based on a-SiC:H multi-layered stacked cells are studied both theoretically and experimentally. Results show that the light-activated photonic device combines the demultiplexing operation with the simultaneous photodetection and self amplification of an optical signal. The sensor is a bias wavelength current-controlled device that make use of changes in the wavelength of the background to control the power delivered to the load, acting a photonic active filter. Its gain depends on the background wavelength that controls the electrical field profile across the device.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A DC-DC step-up micro power converter for solar energy harvesting applications is presented. The circuit is based on a switched-capacitorvoltage tripler architecture with MOSFET capacitors, which results in an, area approximately eight times smaller than using MiM capacitors for the 0.131mu m CMOS technology. In order to compensate for the loss of efficiency, due to the larger parasitic capacitances, a charge reutilization scheme is employed. The circuit is self-clocked, using a phase controller designed specifically to work with an amorphous silicon solar cell, in order to obtain themaximum available power from the cell. This will be done by tracking its maximum power point (MPPT) using the fractional open circuit voltage method. Electrical simulations of the circuit, together with an equivalent electrical model of an amorphous silicon solar cell, show that the circuit can deliver apower of 1132 mu W to the load, corresponding to a maximum efficiency of 66.81%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A voltage limiter circuit for indoor light energy harvesting applications is presented. This circuit is a part of a bigger system, whose function is to harvest indoor light energy, process it and store it, so that it can be used at a later time. This processing consists on maximum power point tracking (MPPT) and stepping-up, of the voltage from the photovoltaic (PV) harvester cell. The circuit here described, ensures that even under strong illumination, the generated voltage will not exceed the limit allowed by the technology, avoiding the degradation, or destruction, of the integrated die. A prototype of the limiter circuit was designed in a 130 nm CMOS technology. The layout of the circuit has a total area of 23414 mu m(2). Simulation results, using Spectre, are presented.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A start-up circuit, used in a micro-power indoor light energy harvesting system, is described. This start-up circuit achieves two goals: first, to produce a reset signal, power-on-reset (POR), for the energy harvesting system, and secondly, to temporarily shunt the output of the photovoltaic (PV) cells, to the output node of the system, which is connected to a capacitor. This capacitor is charged to a suitable value, so that a voltage step-up converter starts operating, thus increasing the output voltage to a larger value than the one provided by the PV cells. A prototype of the circuit was manufactured in a 130 nm CMOS technology, occupying an area of only 0.019 mm(2). Experimental results demonstrate the correct operation of the circuit, being able to correctly start-up the system, even when having an input as low as 390 mV using, in this case, an estimated energy of only 5.3 pJ to produce the start-up.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The main objective of this work was to evaluate the hypothesis that the greater transfer stability leads also to less volume of fumes. Using an Ar + 25%CO2 blend as shielding gas and maintaining constant the average current, wire feed speed and welding speed, bead-on-plate welds were carried out with plain carbon steel solid wire. The welding voltage was scanned to progressively vary the transfer stability. Using two conditions of low stability and one with high stability, fume generation was evaluated by means of the AWS F1.2:2006 standard. The influence of these conditions on fume morphology and composition was also verified. A condition with greater transfer stability does not generate less fume quantity, despite the fact that this condition produces fewer spatters. Other factors such as short-circuit current, arcing time, droplet diameters and arc length are the likely governing factors, but in an interrelated way. Metal transfer stability does not influence either the composition or the size/morphology of fume particulates. (c) 2014 Elsevier B.V. All rights reserved.