12 resultados para COLLAGENASE-2 MMP-8
em Repositório Científico do Instituto Politécnico de Lisboa - Portugal
Resumo:
Digital X-ray detector technologies provide several advantages when compared with screen-film (SF) systems: better diagnostic quality of the radiographic image, increased dose efficiency, better dynamic range and possible reduction of radiation exposure to the patient. The transition from traditional SF systems to digital technology-based systems highlights the importance of the discussion around technical factors such as image acquisition, themanagement of patient dose and diagnostic image quality. Radiographers should be aware of these aspects concerning their clinical practice regarding the advantages and limitations of digital detectors. Newdigital technologies require an up-to-date of scientific knowledge concerning their use in projection radiography. This is the second of a two-part review article focused on a technical overview of digital radiography detectors. This article provides a discussion about the issues related to the image acquisition requirements and advantages of digital technologies, the management of patient dose and the diagnostic image quality.
Resumo:
Trabalho de Projecto para obtenção do grau de Mestre em Engenharia Civil
Resumo:
Aim: Visual acuity outcome of amblyopia treatment depends on the compliance. This study aimed to determine parental predictors of poor visual outcome with occlusion treatment in unilateral amblyopia and identify the relationship between occlusion recommendations and the patient's actual dose of occlusion reported by the parents. Methods: This study comprised three phases: refractive adaptation for a period of 18 weeks after spectacle correction; occlusion of 3 to 6 hours per day during a period of 6 months; questionnaire administration and completion by parents. Visual acuity as assessed using the Sheridan-Gardiner singles or Snellen acuity chart was used as a measure of visual outcome. Correlation analysis was used to describe the strength and direction of two variables: prescribed occlusion reported by the doctor and actual dose reported by parents. A logistic binary model was adjusted using the following variables: severity, vulnerability, self-efficacy, behaviour intentions, perceived efficacy and treatment barriers, parents' and childrens' age, and parents' level of education. Results: The study included 100 parents (mean age 38.9 years, SD approx 9.2) of 100 children (mean age 6.3 years, SD approx 2.4) with amblyopia. Twenty-eight percent of children had no improvement in visual acuity. The results showed a positive mild correlation (kappa = 0.54) between the prescribed occlusion and actual dose reported by parents. Three predictors for poor visual outcome with occlusion were identified: parents' level of education (OR = 9.28; 95%CI 1.32-65.41); treatment barriers (OR = 2.75; 95%CI 1.22-6.20); interaction between severity and vulnerability (OR = 3.64; 95%CI 1.21-10.93). Severity (OR = 0.07; 95%CI 0.00-0.72) and vulnerability (OR = 0.06; 95%CI 0.05-0.74) when considered in isolation were identified as protective factors. Conclusions: Parents frequently do not use the correct dosage of occlusion as recommended. Parents' educational level and awareness of treatment barriers were predictors of poor visual outcome. Lower levels of education represented a 9-times higher risk of having a poor visual outcome with occlusion treatment.
Resumo:
O presente relatório descreve o trabalho desenvolvido ao longo de um estágio realizado na empresa Professor Edgar Cardoso - Engenharia e Laboratório de estruturas no período de Março de 2009 a Maio de 2010. Neste estágio foi desenvolvido o Projecto de Execução do Viaduto sobre os Ramais de Caminho de Ferro pertencentes à SAPEC e à EDP e sobre um SAPAL que lhes fica contíguo, em Praias do Sado, inseridas no 2º lanço da Estrada de Ligação Alto da Guerra - Mitrena. Este viaduto suporta uma faixa de rodagem com duas vias de trânsito em sentidos opostos, e é constituído por um tabuleiro contínuo de 15 vãos, dois extremos de 21,00m e treze intermédios de 35,00 m cada, medidos sobre o eixo longitudinal do tabuleiro, tendo um comprimento total de 497, 00m. A estrutura do viaduto é composta por betão armado e pré-esforçado, sendo o seu tabuleiro apoiado nos encontros e pilares de secção circular, sobre aparelhos móveis unidireccionais, aferrolhados por meio de elementos fusíveis aos dois grupos de pilares centrais. O dimensionamento respeitou os regulamentos nacionais em vigor, nomeadamente o Regulamento de Betão Armado e Pré-Esforçado (R.E.B.A.P.) e o Regulamento de Segurança e Acções para Edifícios e Pontes (R.S.A) e os Eurocódigos 2 e 8, nas situações onde os anteriores são omissos.
Resumo:
O presente relatório tem como objectivo descrever o trabalho desenvolvido ao longo de um estágio, realizado na empresa Professor Edgar Cardoso - Engenharia e Laboratório de Estruturas, durante o período de Fevereiro de 2009 a Maio de 2010. Durante este período, foi realizado um projecto de execução de um viaduto situado no Pinhal Novo. Este possui um comprimento total de 233,0 metros, suporta duas vias de trânsito em sentidos opostos e é constituído por 7 vãos com a seguinte distribuição: 20,0 m – 30,0 m – 35,0 m – 58,0 m – 40,0 m – 30,0 m – 20,0 m Além de compreender um vão central de 58,0 metros, existe ainda a particularidade de o viaduto atravessar um complexo feixe de linhas férreas e a sua directriz ser completamente curva. O tabuleiro é composto por betão armado, pré-esforçado na direcção longitudinal, encontra-se apoiado sobre os encontros e rigidamente ligado a 6 pilares de secção circular. A secção transversal do tabuleiro é constituída por uma nervura de secção trapezoidal, com 12 metros de largura, espessura variável e vazada no 2º, 4º e 6º vão. O dimensionamento respeitou os regulamentos nacionais em vigor, nomeadamente o Regulamento de Estruturas de Betão Armado e Pré-Esforçado (REBAP), o Regulamento de Segurança e Acções para Edifícios e Pontes (RSA) e o Eurocódigo 1, 2 e 8.
Resumo:
Objetivo: O presente estudo tem como objetivo verificar a relação existente entre autonomia funcional e otimismo. Método: Os participantes são 280 indivíduos portadores de esclerose múltipla (EM) diagnosticada há mais de um ano em que a maioria são mulheres, com nível elevado de escolaridade, maioritariamente casados, e a trabalhar em regime de tempo integral. A funcionalidade foi avaliada com a Escala de Impacto de Participação e Autonomia – IPA, e o otimismo com o Life Orientation Test – Revised (LOT-R). A recolha de dados realizou-se em unidades de saúde de Lisboa e cumpriu as regras conforme a Declaração de Helsínquia. Conclusão: Os resultados mostram que existem valores de correlação estatisticamente significativos, mas moderados entre as dimensões da LOT-R e IPA, sugerindo que o otimismo é um fator importante para a autonomia funcional dos indivíduos portadores de EM. ABSTRACT - Aim: The present study aims at identifying the relationship between optimism and functional autonomy in individuals with Multiple Sclerosis (MS). Method: The participants are 280 individuals diagnosed with MS for more than one year; the majority are women, with high levels of education, mostly married and employed on full time. To access functionality we used the Impact on Participation and Autonomy Scale – IPA, and to assess optimism the Life Orientation Test - Revised (LOT-R). Data was collected in Lisbon health settings. Data collection follows the rules of the Helsinki Declaration. Conclusion: Results show that correlations between the two main variables are statistically significant, but moderate, suggesting that the perception of optimism is an important factor for functional autonomy in individuals with MS.
Resumo:
In order to evaluate the capacity of laser scanning cytometry (LSC) to detect acid-fast bacilli directly on clinical samples, a comparison between Kinyoun-stained smears analyzed under light microscopy and propidium iodide-auramine-stained smears analyzed by LSC was performed. The results were compared with those for culture on BACTEC MGIT 960. LSC is a new, reliable methodology to detect Mycobacteria.
Resumo:
Purpose: The most recent Varian® micro multileaf collimator(MLC), the High Definition (HD120) MLC, was modeled using the BEAMNRCMonte Carlo code. This model was incorporated into a Varian medical linear accelerator, for a 6 MV beam, in static and dynamic mode. The model was validated by comparing simulated profiles with measurements. Methods: The Varian® Trilogy® (2300C/D) accelerator model was accurately implemented using the state-of-the-art Monte Carlo simulation program BEAMNRC and validated against off-axis and depth dose profiles measured using ionization chambers, by adjusting the energy and the full width at half maximum (FWHM) of the initial electron beam. The HD120 MLC was modeled by developing a new BEAMNRC component module (CM), designated HDMLC, adapting the available DYNVMLC CM and incorporating the specific characteristics of this new micro MLC. The leaf dimensions were provided by the manufacturer. The geometry was visualized by tracing particles through the CM and recording their position when a leaf boundary is crossed. The leaf material density and abutting air gap between leaves were adjusted in order to obtain a good agreement between the simulated leakage profiles and EBT2 film measurements performed in a solid water phantom. To validate the HDMLC implementation, additional MLC static patterns were also simulated and compared to additional measurements. Furthermore, the ability to simulate dynamic MLC fields was implemented in the HDMLC CM. The simulation results of these fields were compared with EBT2 film measurements performed in a solid water phantom. Results: Overall, the discrepancies, with and without MLC, between the opened field simulations and the measurements using ionization chambers in a water phantom, for the off-axis profiles are below 2% and in depth-dose profiles are below 2% after the maximum dose depth and below 4% in the build-up region. On the conditions of these simulations, this tungsten-based MLC has a density of 18.7 g cm− 3 and an overall leakage of about 1.1 ± 0.03%. The discrepancies between the film measured and simulated closed and blocked fields are below 2% and 8%, respectively. Other measurements were performed for alternated leaf patterns and the agreement is satisfactory (to within 4%). The dynamic mode for this MLC was implemented and the discrepancies between film measurements and simulations are within 4%. Conclusions: The Varian® Trilogy® (2300 C/D) linear accelerator including the HD120 MLC was successfully modeled and simulated using the Monte CarloBEAMNRC code by developing an independent CM, the HDMLC CM, either in static and dynamic modes.
Resumo:
Introduction - Obesity became a major public health problem as a result of its increasing prevalence worldwide. Paraoxonase-1 (PON1) is an esterase able to protect membranes and lipoproteins from oxidative modifications. At the PON1 gene, several polymorphisms in the promoter and coding regions have been identified. The aims of this study were i) to assess PON1 L55M and Q192R polymorphisms as a risk factor for obesity in women; ii) to compare PON1 activity according to the expression of each allele in L55M and Q192R polymorphisms; iii) to compare PON1 activity between obese and normal-weight women. Materials and methods - We studied 75 healthy (35.9±8.2 years) and 81 obese women (34.3±8.2 years). Inclusion criteria for obese subjects were body mass index ≥30 kg/m2 and absence of inflammatory/neoplasic conditions or kidney/hepatic dysfunction. The two PON1 polymorphisms were assessed by real-time PCR with TaqMan probes. PON1 enzymatic activity was assessed by spectrophotometric methods, using paraoxon as a substrate. Results - No significant differences were found for PON1 activity between normal and obese women. Nevertheless, PON1 activity was greater (P<0.01) for the RR genotype (in Q192R polymorphism) and for the LL genotype (in L55M polymorphism). The frequency of allele R of Q192R polymorphism was significantly higher in obese women (P<0.05) and was associated with an increased risk of obesity (odds ratio=2.0 – 95% confidence interval (1.04; 3.87)). Conclusion - 55M and Q192R polymorphisms influence PON1 activity. The allele R of the Q192R polymorphism is associated with an increased risk for development of obesity among Portuguese Caucasian premenopausal women.
Resumo:
A 5-unit polyubiquitin gene, TTU3, was isolated from a T. thermophila genomic library and sequenced. This gene presents an extra triplet coding for Phe, a AGAGA motif and a putative HSE element in its 5'-non-coding region. The ubiquitin gene expression in this ciliate was investigated by Northern blot hybridization in conjugating cells or cells under stress conditions. Exponentially growing cells express two ubiquitin mRNAs of 0.75 and 1.8 kb and a new species of 1.4 kb is induced under hyperthermic stress. During sexual reproduction of the cells (conjugation) the 1.8-kb mRNA is still transcribed whereas the steady-state population of the 0.75 mRNA transcripts is strongly diminished. Southern blot analysis suggests that ubiquitin in T. thermophila constitutes a large family of about ten members.
Resumo:
Background: Addition of energy supplements to preterm formulas is an optional strategy to increase the energy intake in infants requiring fluid restriction, in conditions like bronchopulmonary dysplasia. This strategy may lead to an undesirable increase in osmolality of feeds, the maximum recommended safe limit being 400 mOsm/kg. The aim of the study was to measure the changes in osmolality of several commercialized preterm formulas after addition of glucose polymers and medium-chain triglycerides. Methods: Osmolality was measured by the freezing point depression method. Six powdered formulas with concentrations of 14 g/100 ml and 16 g/100 ml, and five ready-to-feed liquid formulas were analyzed. All formulas, were supplemented with 10% (low supplementation) or 20% (high supplementation) of additional calories, respectively, in the form of glucose polymers and medium chain triglycerides, maintaining a 1:1 glucose:lipid calorie ratio. Inter-analysis and intra-analysis coefficients of variation of the measurements were always < 3.9%. Results: The mean osmolality (mOsm/kg) of the non-supplemented formulas varied between 268.5 and 315.3 mOsm/kg, increasing by 3–5% in low supplemented formulas, and by 6–10% in high supplemented formulas. None of the formulas analyzed exceeded 352.8 mOsm/kg. Conclusion: The supplementation of preterm formulas with nonprotein energy supplements with up to 20% additional calories did not exceed the maximum recommended osmolality for neonatal feedings.
Resumo:
Dissertação de natureza Científica para obtenção do grau de Mestre na Área de Especialização de Estruturas