8 resultados para Best Dominant
em Repositório Científico do Instituto Politécnico de Lisboa - Portugal
Resumo:
Knowledge on forced magma injection and magma flow in dykes is crucial for the understanding of how magmas migrate through the crust to the Earth's surface. Because many questions still persist, we used the long, thick, and deep-seated Foum Zguid dyke (Morocco) to investigate dyke emplacement and internal flow by means of magnetic methods, structural analysis, petrography, and scanning electron microscopy. We also investigated how the host rocks accommodated the intrusion. Regarding internal flow: 1. Important variations of the rock magnetic properties and magnetic fabric occur with distance from dyke wall; 2. anisotropy of anhysteretic remanent magnetization reveals that anisotropy of magnetic susceptibility (AMS) results mainly from the superposition of subfabrics with distinct coercivities and that the imbrication between magnetic foliation and dyke plane is more reliable to deduce flow than the orientation of the AMS maximum principal axis; and 3. a dominant upward flow near the margins can be inferred. The magnetic fabric closest to the dyke wall likely records magma flow best due to fast cooling, whereas in the core the magnetic properties have been affected by high-temperature exsolution and metasomatic effects due to slow cooling. Regarding dyke emplacement, this study shows that the thick forceful intrusion induced deformation by homogeneous flattening and/or folding of the host sedimentary strata. Dewatering related to heat, as recorded by thick quartz veins bordering the dyke in some localities, may have also helped accommodating dyke intrusion. The spatial arrangement of quartz veins and their geometrical relationship with the dyke indicate a preintrusive to synintrusive sinistral component of strike slip.
Resumo:
Introdução – Avaliar a força de preensão mostrou ser de primordial importância pela sua relação com a capacidade funcional dos indivíduos, permitindo determinar níveis de risco para incapacidade futura e, assim, estabelecer estratégias de prevenção. Grande parte dos estudos utiliza o dinamómetro hidráulico JAMAR que fornece o valor da força isométrica obtida durante a execução do movimento de preensão palmar. Contudo, existem outros dinamómetros disponíveis, como é o caso do dinamómetro portátil computorizado E‑Link (Biometrics) que fornece o valor da força máxima (peak force), para além de outras variáveis, como a taxa de fadiga. Não existem, contudo, estudos que nos permitam aceitar e comparar ou não os valores obtidos com os dois equipamentos e porventura utilizá‑los indistintamente. Objetivos – Avaliar a concordância entre as medições da força de preensão (força máxima ou peak force em Kg) obtida a partir de dois equipamentos diferentes (dinamómetros portáteis): um computorizado (E‑Link, Biometrics) e outro hidráulico (JAMAR). Metodologia – Foram avaliados 29 indivíduos (13H; 16M; 22±7 anos; 23,2±3,3 kg/m2) em 2 dias consecutivos, na mesma altura do dia. A posição de teste escolhida foi a recomendada pela Associação Americana de Terapeutas Ocupacionais e foi escolhido o melhor resultado de entre 3 tentativas para a mão dominante. Realizou‑se uma análise correlacional entre os valores obtidos na variável analisada em cada equipamento (coeficiente de Spearman) e uma análise de Bland & Altman para verificar a concordância entre as duas medições. Resultados – O coeficiente de correlação entre as duas medições foi elevado (rS= 0,956; p<0,001) e, pela análise de Bland & Altman, os valores obtidos encontram‑se todos dentro do intervalo da média±2SD. Conclusões – As duas medições mostraram ser concordantes, revelando que os dinamómetros testados podem ser comparáveis ou utilizados indistintamente em diferentes estudos e populações. ABSTRACT: Introduction – Assess grip strength has proved to be of vital importance because of its relationship with functional capacity of individuals, in order to determine levels of risk for future disability and thereby establish prevention strategies. Most studies use the JAMAR Hydraulic dynamometer that provides the value of isometric force obtained during the performance of grip movement. However, there are other dynamometers available, such as portable computerized dynamometer E‑Link (Biometrics), which provides the value of maximum force (peak force) in addition to other variables as the rate of fatigue. There are no studies that allow us to accept or not and compare values obtained with both devices and perhaps use them interchangeably. Purpose – To evaluate the agreement between the measurements of grip strength (peak force or maximum force in kg) obtained from two different devices (portable dynamometers): a computerized (E‑Link, Biometrics) and a hydraulic (JAMAR). Methodology – 29 subjects (13H, 16M, 22 ± 7 years, 23.2 ± 3.3 kg/m2) were assessed on two consecutive days at the same time of day. The test position chosen was recommended by the American Association of Occupational Therapists and was considered the best result from three attempts for the dominant hand. A correlation was studied between values obtained in the variable analyzed in each equipment (Spearman coefficient) and Bland‑Altman analysis to assess the agreement between the two measurements. Results – The correlation coefficient between the two measurements was high (rs = 0,956, p <0,001) and Bland & Altman analysis of the values obtained are all within the range of mean±2SD. Conclusions – The two measurements were shown to be concordant, revealing that the tested dynamometers can be comparable or used interchangeably in different studies and populations.
Resumo:
A family of 9H-thioxanthen-9-one derivatives and two precursors, 2-[(4-bromophenyl) sulfanyl]-5-nitrobenzoic acid and 2-[(4-aminophenyl) sulfanyl]-5-nitrobenzoic acid, were synthesized and studied in order to assess the role of the different substituent groups in determining the supramolecular motifs. From our results we can conclude that Etter's rules are obeyed: whenever present the -COOH head to head strong hydrogen bonding dimer, R-2(2)(8) synthon, prevails as the dominant interaction. As for -NH2, the best donor when present also follows the expected hierarchy, an NH center dot center dot center dot O(COOH) was formed in the acid precursor (2) and an NH center dot center dot center dot O(C=O) in the thioxanthone (4). The main role played by weaker hydrogen bonds such as CH center dot center dot center dot O, and other intermolecular interactions, pi-pi and Br center dot center dot center dot O, as well as the geometric restraints of packing patterns shows the energetic interplay governing crystal packing. A common feature is the relation between the p-p stacking and the unit cell dimensions. A new synthon notation, R`, introduced in this paper, refers to the possibility of accounting for intra- and intermolecular interactions into recognizable and recurring aggregate patterns.
Resumo:
Trends between the Hammett's sigma(p) and related normal sigma(n)(p), inductive sigma(I), resonance sigma(R), negative sigma(-)(p) and positive sigma(+)(p) polar conjugation and Taft's sigma(o)(p) substituent constants and the N-H center dot center dot center dot O distance, delta(N-H) NMR chemical shift, oxidation potential (E-p/2(ox), measured in this study by cyclic voltammetry (CV)) and thermodynamic parameters (pK, Delta G(0), Delta H-0 and Delta S-0) of the dissociation process of unsubstituted 3-(phenylhydrazo)pentane-2,4-dione (HL1) and its para-substituted chloro (HL2), carboxy (HL3), fluoro (HL4) and nitro (HL5) derivatives were recognized. The best fits were found for sigma(p) and/or sigma(-)(p) in the cases of d(N center dot center dot center dot O), delta(N-H) and E-p/2(ox), showing the importance of resonance and conjugation effects in such properties, whereas for the above thermodynamic properties the inductive effects (sigma(I)) are dominant. HL2 exists in the hydrazo form in DMSO solution and in the solid state and contains an intramolecular H-bond with the N center dot center dot center dot O distance of 2.588(3)angstrom. It was also established that the dissociation process of HL1-5 is non-spontaneous, endothermic and entropically unfavourable, and that the increase in the inductive effect (sigma(I)) of para-substitutents (-H < -Cl < -COOH < -F < -NO2) leads to the corresponding growth of the N center dot center dot center dot O distance and decrease of the pK and of the changes of Gibbs free energy, of enthalpy and of entropy for the HL1-5 acid dissociation process. The electrochemical behaviour of HL1-5 was interpreted using theoretical calculations at the DFT/HF hybrid level, namely in terms of HOMO and LUMO compositions, and of reactivities induced by anodic and cathodic electron-transfers. Copyright (C) 2010 John Wiley & Sons, Ltd.
Expert opinion on best practice guidelines and competency framework for visual screening in children
Resumo:
PURPOSE: Screening programs to detect visual abnormalities in children vary among countries. The aim of this study is to describe experts' perception of best practice guidelines and competency framework for visual screening in children. METHODS: A qualitative focus group technique was applied during the Portuguese national orthoptic congress to obtain the perception of an expert panel of 5 orthoptists and 2 ophthalmologists with experience in visual screening for children (mean age 53.43 years, SD ± 9.40). The panel received in advance a script with the description of three tuning competencies dimensions (instrumental, systemic, and interpersonal) for visual screening. The session was recorded in video and audio. Qualitative data were analyzed using a categorical technique. RESULTS: According to experts' views, six tests (35.29%) have to be included in a visual screening: distance visual acuity test, cover test, bi-prism or 4/6(Δ) prism, fusion, ocular movements, and refraction. Screening should be performed according to the child age before and after 3 years of age (17.65%). The expert panel highlighted the influence of the professional experience in the application of a screening protocol (23.53%). They also showed concern about the false negatives control (23.53%). Instrumental competencies were the most cited (54.09%), followed by interpersonal (29.51%) and systemic (16.4%). CONCLUSIONS: Orthoptists should have professional experience before starting to apply a screening protocol. False negative results are a concern that has to be more thoroughly investigated. The proposed framework focuses on core competencies highlighted by the expert panel. Competencies programs could be important do develop better screening programs.
Resumo:
Electrocardiographic (ECG) signals are emerging as a recent trend in the field of biometrics. In this paper, we propose a novel ECG biometric system that combines clustering and classification methodologies. Our approach is based on dominant-set clustering, and provides a framework for outlier removal and template selection. It enhances the typical workflows, by making them better suited to new ECG acquisition paradigms that use fingers or hand palms, which lead to signals with lower signal to noise ratio, and more prone to noise artifacts. Preliminary results show the potential of the approach, helping to further validate the highly usable setups and ECG signals as a complementary biometric modality.
Resumo:
The aim of this study was to describe experts’ perception of best-practice guidelines and competency framework for visual screening in children. This study uses qualitative data and shows individual/ group conceptualization. The use of evidence from qualitative studies has traditionally been a fundamental source of knowledge in the clinical and social sciences.
Resumo:
The harmony between the stump and the prosthesis is critical to allow it to fulfill its function enabling an efficient gait. A well fitted socket, with an efficient and comfortable suspension, allows the amputee to continue their daily living activities, maintaining the stump functional, making this correlation between socket and suspension very important in the functionality of the prosthesis, mobility and overall satisfaction with the device. Of our knowledge, the quantitative correlation between all of these factors as not yet been assessed. Aim of study: Verify and confirm the process of decision-making for four different trans-tibial prostheses with suspension systems: Hypobaric(A), PIN(B), Classic Suction(C) and Vacuum Active –VASS(D) according data provided by gait efficiency (mlO2/kg/m) imagiology (pistonning) and amputee perception.