17 resultados para Beginning number
em Repositório Científico do Instituto Politécnico de Lisboa - Portugal
Resumo:
This paper is part of the Project “Adaptive thinking and flexible computation: Critical issues”. In this paper we discuss different perspectives of flexibility and adaptive thinking in literature. We also discuss the idea of proceptual thinking and how this idea is important in our perspective of adaptive thinking. The paper analyses a situation developed with a first grade classroom and its teacher named the day number. It is a daily activity at the beginning of the school day. It consists on to look for the date number and to think about different ways of writing it using the four arithmetic operations. The analyzed activity was developed on March 19, so the challenge was to write 19 in several ways. The data show the pupils’ enthusiasm and their efforts to find different ways of writing the number. Some used large numbers and division, which they were just starting to learn. The pupils presented symbolic expressions of 19, decomposing and recomposing it in a flexible manner.
Resumo:
We have performed Surface Evolver simulations of two-dimensional hexagonal bubble clusters consisting of a central bubble of area lambda surrounded by s shells or layers of bubbles of unit area. Clusters of up to twenty layers have been simulated, with lambda varying between 0.01 and 100. In monodisperse clusters (i.e., for lambda = 1) [M.A. Fortes, F Morgan, M. Fatima Vaz, Philos. Mag. Lett. 87 (2007) 561] both the average pressure of the entire Cluster and the pressure in the central bubble are decreasing functions of s and approach 0.9306 for very large s, which is the pressure in a bubble of an infinite monodisperse honeycomb foam. Here we address the effect of changing the central bubble area lambda. For small lambda the pressure in the central bubble and the average pressure were both found to decrease with s, as in monodisperse clusters. However, for large,, the pressure in the central bubble and the average pressure increase with s. The average pressure of large clusters was found to be independent of lambda and to approach 0.9306 asymptotically. We have also determined the cluster surface energies given by the equation of equilibrium for the total energy in terms of the area and the pressure in each bubble. When the pressures in the bubbles are not available, an approximate equation derived by Vaz et al. [M. Fatima Vaz, M.A. Fortes, F. Graner, Philos. Mag. Lett. 82 (2002) 575] was shown to provide good estimations for the cluster energy provided the bubble area distribution is narrow. This approach does not take cluster topology into account. Using this approximate equation, we find a good correlation between Surface Evolver Simulations and the estimated Values of energies and pressures. (C) 2008 Elsevier B.V. All rights reserved.
Resumo:
Mestrado em Controlo e Gestão dos Negócios
Resumo:
Myocardial Perfusion Gated Single Photon Emission Tomography (Gated-SPET) imaging is used for the combined evaluation of myocardial perfusion and left ventricular (LV) function. But standard protocols of the Gated-SPECT studies require long acquisition times for each study. It is therefore important to reduce as much as possible the total duration of image acquisition. However, it is known that this reduction leads to decrease on counts statistics per projection and raises doubts about the validity of the functional parameters determined by Gated-SPECT. Considering that, it’s difficult to carry out this analysis in real patients. For ethical, logistical and economical matters, simulated studies could be required for this analysis. Objective: Evaluate the influence of the total number of counts acquired from myocardium, in the calculation of myocardial functional parameters (LVEF – left ventricular ejection fraction, EDV – end-diastolic volume, ESV – end-sistolic volume) using routine software procedures.
Resumo:
Relatório Final de Estágio apresentado à Escola Superior de Dança, com vista à obtenção do grau de Mestre em Ensino de Dança.
Resumo:
Relatório de Estágio apresentado à Escola Superior de Educação de Lisboa para obtenção de grau de mestre em Ensino do 1.º e do 2.º Ciclo do Ensino Básico
Resumo:
A maioria dos órgãos históricos portugueses data dos finais do século XVIII ou do princípio do século XIX. Durante este período foi construído um invulgar número de instrumentos em Lisboa e nas áreas circundantes por António Xavier Machado e Cerveira (1756-1828) e outros organeiros menos prolíficos. O estudo desses órgãos, muitos dos quais (restaurados ou não) se encontram próximos das condições originais, permite a identificação de um tipo de instrumento com uma morfologia específica, claramente emancipada do chamado «órgão ibérico». No entanto, até muito recentemente, não era conhecida música que se adaptasse às idiossincrasisas daqueles instrumentos. O recente estudo das obras para órgão de José Marques e Silva (1782-1837) permitiu clarificar esta situação. Bem conhecido durante a sua vida como organista e compositor, José Marques e Silva foi um dos ultimos mestres do Seminário Patriarcal. A importância da sua produção musical reside não só num substancial número de obras com autoria firmemente estabelecida – escritas, na maior parte, para coro misto com acompanhamento de órgão obbligato – mas também na íntima relação entre a sua escrita e a morfologia dos órgãos construídos em Portugal durante a sua vida. Este artigo enfatiza a importância de José Marques e Silva (indubitavelmente, o mais significativo compositor português para órgão do seu tempo) sublinhando a relevância das suas obras para órgão solo, cujo uso extensivo de escrita idiomática e indicações de registação fazem delas um dos mais importantes documentos só início do século XIX sobre a prática organística em Portugal.
Resumo:
Cluster analysis for categorical data has been an active area of research. A well-known problem in this area is the determination of the number of clusters, which is unknown and must be inferred from the data. In order to estimate the number of clusters, one often resorts to information criteria, such as BIC (Bayesian information criterion), MML (minimum message length, proposed by Wallace and Boulton, 1968), and ICL (integrated classification likelihood). In this work, we adopt the approach developed by Figueiredo and Jain (2002) for clustering continuous data. They use an MML criterion to select the number of clusters and a variant of the EM algorithm to estimate the model parameters. This EM variant seamlessly integrates model estimation and selection in a single algorithm. For clustering categorical data, we assume a finite mixture of multinomial distributions and implement a new EM algorithm, following a previous version (Silvestre et al., 2008). Results obtained with synthetic datasets are encouraging. The main advantage of the proposed approach, when compared to the above referred criteria, is the speed of execution, which is especially relevant when dealing with large data sets.
Resumo:
Myocardial Perfusion Gated Single Photon Emission Tomography (Gated-SPET) imaging is used for the combined evaluation of myocardial perfusion and left ventricular (LV). The purpose of this study is to evaluate the influence of the total number of counts acquired from myocardium, in the calculation of myocardial functional parameters using routine software procedures. Methods: Gated-SPET studies were simulated using Monte Carlo GATE package and NURBS phantom. Simulated data were reconstructed and processed using the commercial software package Quantitative Gated-SPECT. The Bland-Altman and Mann-Whitney-Wilcoxon tests were used to analyze the influence of the number of total counts in the calculation of LV myocardium functional parameters. Results: In studies simulated with 3MBq in the myocardium there were significant differences in the functional parameters: Left ventricular ejection fraction (LVEF), end-systolic volume (ESV), Motility and Thickness; between studies acquired with 15s/projection and 30s/projection. Simulations with 4.2MBq show significant differences in LVEF, end-diastolic volume (EDV) and Thickness. Meanwhile in the simulations with 5.4MBq and 8.4MBq the differences were statistically significant for Motility and Thickness. Conclusion: The total number of counts per simulation doesn't significantly interfere with the determination of Gated-SPET functional parameters using the administered average activity of 450MBq to 5.4MBq in myocardium.
Resumo:
Trabalho Final de Mestrado para obtenção do grau de Mestre em Engenharia Mecânica
Resumo:
Devido ao acréscimo significativo de viaturas e peões nas grandes cidades foi necessário recorrer aos mecanismos existentes para coordenar o tráfego. Nesta perspectiva surge a implementação de semáforos com o objectivo de ordenar o tráfego nas vias rodoviárias. A gestão de tráfego, tem sido sujeita a inovações tanto ao nível dos equipamentos, do software usado, gestão centralizada, monitorização das vias e na sincronização semafórica, sendo possível a criação de programas ajustados às diferentes exigências de tráfego verificadas durante as vinte e quatro horas para pontos distintos da cidade. Conceptualmente foram elaborados estudos, com o objectivo de identificar a relação entre a velocidade o fluxo e o intervalo num determinado intervalo de tempo, bem como a relação entre a velocidade e a sinistralidade. Até 1995 Portugal era um dos países com maior número de sinistros rodoviários Na sequência desta evolução foram instalados radares de controlo de velocidade no final de 2006 com o objectivo de obrigar ao cumprimento dos limites de velocidade impostos pelo código da estrada e reduzir a sinistralidade automóvel na cidade de Lisboa. Passados alguns anos sobre o investimento realizadoanteriormente, constatamos que existe a necessidade de implementar novas tecnologias na detecção das infracções, sejam estas de excesso de velocidade ou violação do semáforo vermelho (VSV), optimizar a informação disponibilizada aos automobilistas e aos peões, coordenar a interacção entre os veículos prioritários e os restantes presentes na via, dinamizar a gestão interna das contra ordenações, agilizar os procedimentos informatizar a recolha deinformação de modo a tornar os processos mais céleres.
Resumo:
Environment monitoring has an important role in occupational exposure assessment. However, due to several factors is done with insufficient frequency and normally don´t give the necessary information to choose the most adequate safety measures to avoid or control exposure. Identifying all the tasks developed in each workplace and conducting a task-based exposure assessment help to refine the exposure characterization and reduce assessment errors. A task-based assessment can provide also a better evaluation of exposure variability, instead of assessing personal exposures using continuous 8-hour time weighted average measurements. Health effects related with exposure to particles have mainly been investigated with mass-measuring instruments or gravimetric analysis. However, more recently, there are some studies that support that size distribution and particle number concentration may have advantages over particle mass concentration for assessing the health effects of airborne particles. Several exposure assessments were performed in different occupational settings (bakery, grill house, cork industry and horse stable) and were applied these two resources: task-based exposure assessment and particle number concentration by size. The results showed interesting results: task-based approach applied permitted to identify the tasks with higher exposure to the smaller particles (0.3 μm) in the different occupational settings. The data obtained allow more concrete and effective risk assessment and the identification of priorities for safety investments.
Resumo:
Myocardial perfusion gated-single photon emission computed tomography (gated-SPECT) imaging is used for the combined evaluation of myocardial perfusion and left ventricular (LV) function. The aim of this study is to analyze the influence of counts/pixel and concomitantly the total counts in the myocardium for the calculation of myocardial functional parameters. Material and methods: Gated-SPECT studies were performed using a Monte Carlo GATE simulation package and the NCAT phantom. The simulations of these studies use the radiopharmaceutical 99mTc-labeled tracers (250, 350, 450 and 680MBq) for standard patient types, effectively corresponding to the following activities of myocardium: 3, 4.2, 5.4-8.2MBq. All studies were simulated using 15 and 30s/projection. The simulated data were reconstructed and processed by quantitative-gated-SPECT software, and the analysis of functional parameters in gated-SPECT images was done by using Bland-Altman test and Mann-Whitney-Wilcoxon test. Results: In studies simulated using different times (15 and 30s/projection), it was noted that for the activities for full body: 250 and 350MBq, there were statistically significant differences in parameters Motility and Thickness. For the left ventricular ejection fraction (LVEF), end-systolic volume (ESV) it was only for 250MBq, and 350MBq in the end-diastolic volume (EDV), while the simulated studies with 450 and 680MBq showed no statistically significant differences for global functional parameters: LVEF, EDV and ESV. Conclusion: The number of counts/pixel and, concomitantly, the total counts per simulation do not significantly interfere with the determination of gated-SPECT functional parameters, when using the administered average activity of 450MBq, corresponding to the 5.4MBq of the myocardium, for standard patient types.
Resumo:
Invariant integrals are derived for nematic liquid crystals and applied to materials with small Ericksen number and topological defects. The nematic material is confined between two infinite plates located at y = -h and y = h (h is an element of R+) with a semi-infinite plate at y = 0 and x < 0. Planar and homeotropic strong anchoring boundary conditions to the director field are assumed at these two infinite and semi-infinite plates, respectively. Thus, a line disclination appears in the system which coincides with the z-axis. Analytical solutions to the director field in the neighbourhood of the singularity are obtained. However, these solutions depend on an arbitrary parameter. The nematic elastic force is thus evaluated from an invariant integral of the energy-momentum tensor around a closed surface which does not contain the singularity. This allows one to determine this parameter which is a function of the nematic cell thickness and the strength of the disclination. Analytical solutions are also deduced for the director field in the whole region using the conformal mapping method. (C) 2013 Elsevier Ltd. All rights reserved.
Resumo:
Our aim was to analyse the impact of the characteristics of words used in spelling programmes and the nature of instructional guidelines on the evolution from grapho-perceptive writing to phonetic writing in preschool children. The participants were 50 5-year-old children, divided in five equivalent groups in intelligence, phonological skills and spelling. All the children knew the vowels and the consonants B, D, P, R, T, V, F, M and C, but didn’t use them on spelling. Their spelling was evaluated in a pre and post-test with 36 words beginning with the consonants known. In-between they underwent a writing programme designed to lead them to use the letters P and T to represent the initial phonemes of words. The groups differed on the kind of words used on training (words whose initial syllable matches the name of the initial letter—Exp. G1 and Exp. G2—versus words whose initial syllable is similar to the sound of the initial letter—Exp. G3 and Exp. G4). They also differed on the instruction used in order to lead them to think about the relations between the initial phoneme of words and the initial consonant (instructions designed to make the children think about letter names—Exp. G1 and Exp. G3 —versus instructions designed to make the children think about letter sounds—Exp. G2 and Exp. G4). The 5th was a control group. All the children evolved to syllabic phonetisations spellings. There are no differences between groups at the number of total phonetisations but we found some differences between groups at the quality of the phonetisations.