7 resultados para Basic operations

em Repositório Científico do Instituto Politécnico de Lisboa - Portugal


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Nowadays, most individuals spend about 80% of their time indoor and, consequently, the exposure to the indoor environment becomes more relevant than to the outdoor one. Children spend most of their time at home and at school and evaluations of their indoor environment are important for the time-weighted exposure. Due to their airways still in development, children are a sensitive group with higher risk than adults. Larger impact in health and educational performance of children demand indoor air quality studies of schools. The aim of this study was to assess the children exposure to bioaerosols. A methodology based upon passive sampling was applied to evaluate fungi, bacteria and pollens; its procedures and applicability was optimized. An indoor air study by passive sampling represents an easier and cheaper method when comparing with the use of automatic active samplers. Furthermore, it is possible to achieve important quality information without interfering in the classroom activities. The study was conducted in three schools, representative of different environments in the Lisbon urban area, at three different periods of the year to obtain a seasonal variation, to estimate the variability through the city and to understand the underneath causes. Fungi and bacteria were collected indoor and outdoor of the classrooms to determine the indoor/outdoor ratios and to assess the level of outdoor contamination upon the indoor environment. The children's exposure to pollen grains inside the classrooms was also assessed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study is to assess the levels of airborne ultrafine particles emitted in welding processes (tungsten inert gas [TIG], metal active gas [MAG] of carbon steel, and friction stir welding [FSW] of aluminum) in terms of deposited area in pulmonary alveolar tract using a nanoparticle surface area monitor (NSAM) analyzer. The obtained results showed the dependence of process parameters on emitted ultrafine particles and demonstrated the presence of ultrafine particles compared to background levels. Data indicated that the process that resulted in the lowest levels of alveolar deposited surface area (ADSA) was FSW, followed by TIG and MAG. However, all tested processes resulted in significant concentrations of ultrafine particles being deposited in humans lungs of exposed workers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Os Hospitais, equipamentos de interesse público, são edifícios cujos desempenho e disponibilidade das suas instalações e equipamentos podem comprometer a prestação de cuidados de saúde, pelo que nestes estabelecimentos, a Manutenção Preventiva assume um papel relevante. Nesse sentido, pretendeu-se nesta dissertação definir uma estratégia específica que permita efectuar o planeamento da manutenção preventiva de um edifício hospitalar, enquanto infraestrutura para desenvolvimento da actividade clínica. Para tal, foi efectuada uma pesquisa bibliográfica, com a qual se identificaram conceitos de manutenção e requisitos a serem tidos em conta na manutenção de edifícios hospitalares. Foi efectuada uma caracterização genérica do objecto de manutenção, limitada no âmbito desta dissertação às principais componentes dos sistemas de construção e das instalações de águas e esgotos, que podem integrar um edifício hospitalar actual, atendendo às especificações e recomendações técnicas vigentes para este tipo de edifícios. Foram identificados os objectivos e requisitos de manutenção nestes edifícios, estabelecidos pelas condições de funcionamento pretendidas, pelos critérios de durabilidade exigidos pelo Dono de Obra, pelo nível de desempenho funcional requerido para as suas componentes e pelo grau de operacionalidade imposto nas suas diferentes unidades funcionais. Tendo em consideração que a criticidade de uma componente não depende só do contexto operacional da área funcional em se insere mas também das consequências que o seu estado de funcionamento pode acarretar para a unidade funcional. Foi exemplificada a análise dos modos de falha, sua criticidade e seus efeitos para hierarquização do risco associado nas componentes estudadas. As fichas exemplificativas dos planos de manutenção preventiva, que se apresentam no âmbito desta dissertação para algumas componentes básicas, integram acções e procedimentos que derivam de uma análise aos seus modos de falha e seus efeitos, bem como de recomendações técnicas exigências da regulamentação em vigor.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective - To describe and validate the simulation of the basic features of GE Millennium MG gamma camera using the GATE Monte Carlo platform. Material and methods - Crystal size and thickness, parallel-hole collimation and a realistic energy acquisition window were simulated in the GATE platform. GATE results were compared to experimental data in the following imaging conditions: a point source of 99mTc at different positions during static imaging and tomographic acquisitions using two different energy windows. The accuracy between the events expected and detected by simulation was obtained with the Mann–Whitney–Wilcoxon test. Comparisons were made regarding the measurement of sensitivity and spatial resolution, static and tomographic. Simulated and experimental spatial resolutions for tomographic data were compared with the Kruskal–Wallis test to assess simulation accuracy for this parameter. Results - There was good agreement between simulated and experimental data. The number of decays expected when compared with the number of decays registered, showed small deviation (≤0.007%). The sensitivity comparisons between static acquisitions for different distances from source to collimator (1, 5, 10, 20, 30cm) with energy windows of 126–154 keV and 130–158 keV showed differences of 4.4%, 5.5%, 4.2%, 5.5%, 4.5% and 5.4%, 6.3%, 6.3%, 5.8%, 5.3%, respectively. For the tomographic acquisitions, the mean differences were 7.5% and 9.8% for the energy window 126–154 keV and 130–158 keV. Comparison of simulated and experimental spatial resolutions for tomographic data showed no statistically significant differences with 95% confidence interval. Conclusions - Adequate simulation of the system basic features using GATE Monte Carlo simulation platform was achieved and validated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study is to assess the levels of airborne ultrafine particles emitted in welding processes (tungsten inert gas [TIG], metal active gas [MAG] of carbon steel, and friction stir welding [FSW] of aluminum) in terms of deposited area in pulmonary alveolar tract using a nanoparticle surface area monitor (NSAM) analyzer. The obtained results showed the dependence of process parameters on emitted ultrafine particles and demonstrated the presence of ultrafine particles compared to background levels. Data indicated that the process that resulted in the lowest levels of alveolar deposited surface area (ADSA) was FSW, followed by TIG and MAG. However, all tested processes resulted in significant concentrations of ultrafine particles being deposited in humans lungs of exposed workers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Scope of study: welding operations result in harmful emissions of nanoparticles; the aim of emissions monitorisation is to evaluate exposure levels and to derive protection measures in order to protect exposed workers; however, the traditional approach of comparing measured concentrations with exposure limits cannot be used; but risk levels can be quantified by using Control Banding Strategies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper describes the use of a Control Banding Tool to assess and further control of exposure of nanoparticles emitted during welding operations. The tool was applied to Metal Active Gas (MAG) arc welding of mild and stainless steel, providing semi-quantitative data on the process, so that protection measures could be derived, e.g. exhaust gas ventilation by hoods, local ventilation devices and containment measures. This tool is quite useful to compare and evaluate the characteristics of arc welding procedures so that more eco-friendly processes could be preferred over the more potentially noxious ones.