39 resultados para AIR CO2 ENRICHMENT
em Repositório Científico do Instituto Politécnico de Lisboa - Portugal
Resumo:
In this study, the results of chemical concentrations inside and outside of a Lisbon (Portugal) traffic tunnel were compared, during one week. They were obtained by Instrumental Neutron Activation Analysis (INAA). The tunnel values largely exceed the Air Ambient legislated values and the Pearson Correlations Coefficients point out to soil re-suspension/dispersed road dust (As, Ce, Eu, Hf, Fe, Mo, Sc, Zn), traffic-markers (Ba, Cr), tire wear (Cr, Zn), break wear (Fe, Zn, Ba, Cu, Sb), exhaust and motor oil (Zn) and sea-spray (Br, Na). On all days these elements inside the tunnel were more enriched than outside; significant statistical differences were found for Co (p=0.005), Br (p=0.008), Zn (p=0.01) and Sb (p=0.005), while enrichment factors of As and Sc are statistically identical. The highest values were found for As, Br, Zn and Sb, for both inside and outside the tunnel.
Resumo:
Indoor air quality recently entered legislation in Portugal. Several parameters must be evaluated and kept within limits in order to obtain a certification for air quality and energy consumption. Certification parameters were analyzed in two Portuguese archives in order to assess indoor air quality both for people attending or working on these premises and for maintenance of a written heritage that must be retained for future generations. Carbon monoxide (CO) and carbon dioxide (CO2), formaldehyde, and fungal counts were kept within stipulated limits. Relative humidity (RH), volatile organic compounds (VOC), particulate matter (PM10), and ozone (O3) showed values above legislated levels and justified the implementation of corrective measures. In terms of conservation, studies on the limit values are still needed, but according to the available international guidelines, some of the analyzed parameters such as PM10, O3, and RH were also above desirable values. Corrective measures were proposed to these institutions. Although this study was only of a short duration, it proved valuable in assessing potential eventual problems and constitutes the first Portuguese indoor air quality assessment taking into consideration both aspects of an archive such as human health and heritage safekeeping.
Resumo:
The mycelium and young fruiting bodies of Agaricus blazei were submitted to supercritical CO2 extraction, in a modified commercial flow apparatus, at temperatures from 40 to 80 ºC, pressures up to 600 bar and CO2 flow-rates from 2.0 to 9.0 g.min-1. The best extraction conditions of secondary metabolites, whereby the degree of solubilization (g extract/100 g of fungi) is the highest, was obtained with pure CO2 at 400 bar, 70 ºC and a CO2 flow rate of 5.7g.min-1. The extract in that conditions were analysed by GC-Ms. In order to increase the extraction yield of secondary metabolites, which are mostly present in glycolipid fractions, a polar compound (ethanol) was used as co-solvent in the proportions of 5 and 10 % (mol/mol). The presence of ethanol increased the yield when compared with the extraction with pure CO2. Moreover, a simple model was applied to the supercritical CO2 extraction of secondary metabolites from Agaricus blazei.
Resumo:
The modelling of the experimental data of the extraction of the volatile oil from six aromatic plants (coriander, fennel, savoury, winter savoury, cotton lavender and thyme) was performed using five mathematical models, based on differential mass balances. In all cases the extraction was internal diffusion controlled and the internal mass transfer coefficienty (k(s)) have been found to change with pressure, temperature and particle size. For fennel, savoury and cotton lavender, the external mass transfer and the equilibrium phase also influenced the second extraction period, since k(s) changed with the tested flow rates. In general, the axial dispersion coefficient could be neglected for the conditions studied, since Peclet numbers were high. On the other hand, the solute-matrix interaction had to be considered in order to ensure a satisfactory description of the experimental data.
Resumo:
Fungal contamination of air in 10 gymnasiums with swimming pools was monitored. Fifty air samples of 200 L each were collected, using a Millipore air tester, from the area surrounding the pool, in training studios, in showers and changing rooms for both sexes, and also, outside premises, since these are the places regarded as reference. Simultaneously, environmental parameters – temperature and humidity – were also monitored. Some 25 different species of fungi were identified. The six most commonly isolated genera were the following: Cladosporium sp. (36.6%), Penicillium sp. (19.0%), Aspergillus sp. (10.2%), Mucor sp. (7%), Phoma sp. and Chrysonilia sp. (3.3%). For yeasts, three different genera were identified, namely, Rhodotorula sp. (70%), Trichosporon mucoides and Cryptococcus uniguttulattus (10%).
Resumo:
A descriptive study was developed to monitor air fungal contamination in two elementary schools in Lisbon, Portugal. Eight air samples of 250 litres through impaction method were collected in canteen, library, classrooms and also, outside premises as reference place. Simultaneously, were also monitored environmental parameters, including temperature, and humidity through the equipment Babouc, LSI Sistems and according to the International Standard ISO 7726 - 1998. Considering both schools, sixteen different species of fungi in air were identified, being the 2 most commonly isolated Cladosporium sp. (51,1%) and Penicillium sp. (27,5%). Besides these genera Trichoderma, Aspergillus, Alternaria, Chrysonilia, Botritys, Ulocladium, Athrium, Aureobasidium, Phoma, Scedosporium e Geotrichum were also isolated. Regarding yeasts, Candida sp., Cryptococcus sp. and Rhodotorula sp. were isolated. The youngest school, as well canteens in each school, presented the worst results concerning the air fungal contamination, maybe due to the higher number of occupants. There was no significant relationship (p>0,05) between fungal contamination and temperature and humidity.
Resumo:
Este trabalho visa, como objectivo principal, contribuir para o estudo da absorção de CO2 em gases de combustão, utilizando MEA. Tem também, como objectivo secundário, o dimensionamento de uma unidade de absorção assim como uma avaliação económica do respectivo projecto. Assim, esta tese divide-se em duas partes: a primeira parte refere-se ao projecto da instalação piloto para captura de CO2 utilizando a tecnologia de absorção gasosa e de modo a ser possível a utilização de soluções de aminas. A segunda parte desta tese descreve a simulação da operação da instalação de absorção de CO2 em HYSYS, e a respectiva avaliação económica do projecto, na impossibilidade prática de realizar ensaios laboratoriais, considerando o espaço de tempo que medeia entre a especificação do equipamento a adquirir e a recepção desses mesmos equipamentos, incompatível com o tempo disponível para a realização desta tese de Mestrado. Na primeira parte do trabalho foi realizada a avaliação de uma unidade já existente no IST permitindo, dessa forma, verificar o estado da mesma assim como o material que é necessário adquirir de forma a conseguir a sua conversão numa unidade de absorção de CO2 em contínuo. Após a conclusão deste estudo, pode concluir-se que a instalação piloto terá um custo, com bases nos orçamentos, de 7.262€. Na segunda parte do projecto foi realizada uma simulação em HYSYS da operação de captura de CO2. Esta simulação tinha como principal objecto poder determinar as melhores condições operatórias a utilizar na unidade, para posterior comparação com os resultados que irão, posteriormente, ser obtidos em laboratório, ficando-se na captura de CO2 a partir dos efluentes gasosos da Central Termoeléctrica de Sines que é uma unidade do sistema gerador nacional candidata a fazer-se a captura de CO2 recorrendo a esta tecnologia. Desta forma, a simulação apresentou os seguintes resultados principais: uma percentagem de CO2 capturado de 90,61%. A unidade apresenta um custo de 82€/ton CO2 e um custo operacional de 28 M€/ano. Por fim, os resultados obtidos pelo simulador HYSYS foram comparados com outros resultados obtidos em ASPEN PLUS, tendo sido possível concluir que o HYSYS é o simulador mais fiável devido a fiabilidade do pacote de propriedades, e mais simples de trabalhar em comparação como o ASPEN PLUS, quando aplicado a esta situação. Este trabalho resultou na apresentação de uma comunicação em painel no 2º Encontro do IBB, em Braga em Outubro de 2010 e, ainda na elaboração de um artigo submetido a uma revista internacional.
Resumo:
Formaldehyde was the first air pollutant, which already in the 1970s emerged as a specifically non-industrial indoor air quality problem. Yet formaldehyde remained an indoor air quality issue and the formaldehyde level in residential indoor air is among the highest of any indoor air contaminant. Formaldehyde concentrations in 4 different indoor settings (schools, office buildings, new dwellings and occupied dwellings) in Portugal were measured using Photo Ionization Detection (PID) equipment (11,7 eV lamps). All the settings presented results higher than the reference value proposed by Portuguese legislation. Furthermore, occupied dwellings showed 3 units with results above the reference. We could conclude that formaldehyde presence is a reality in monitored indoor settings. Concentration levels are higher than the Portuguese reference value for indoor settings and these can indicate health problems for occupants.
Resumo:
Introduction - Microscopic filamentous fungi, under suitable environmental conditions, can lead to the production of highly toxic chemical substances, commonly known as mycotoxins. The most widespread and studied mycotoxins are metabolites of some genera of moulds such as Aspergillus, Penicillium and Fusarium. Quite peculiar conditions may influence mycotoxin biosynthesis, such as climate, geographical location, cultivation practices, storage and type of substrate. Toxicity has been extensively investigated for the most important mycotoxins, such as aflatoxins, ochratoxin A and Fusarium toxins, and much information derived from toxicokinetics in animal models has also been obtained. The adverse effects are mainly related to genotoxicity, carcinogenicity, mutagenicity, teratogenicity and immunotoxicity. Aim of the study - To identify fungal species able to produce important mycotoxins in different Portuguese settings.
Resumo:
A biomonitoring study, using transplanted lichens Flavoparmelia caperata, was conducted to assess the indoor air quality in primary schools in urban (Lisbon) and rural (Ponte de Sor) Portuguese sites. The lichens exposure period occurred between April and June 2010 and two types of environments of the primary schools were studied: classrooms and outdoor/courtyard. Afterwards, the lichen samples were processed and analyzed by instrumental neutron activation analysis (INAA) to assess a total of 20 chemical elements. Accumulated elements in the exposed lichens were assessed and enrichment factors (EF) were determined. Indoor and outdoor biomonitoring results were compared to evaluate how biomonitors (as lichens) react at indoor environments and to assess the type of pollutants that are prevalent in those environments.
Resumo:
One Plus Sequential Air Sampler—Partisol was placed in a small village (Foros de Arrão) in central Portugal to collect PM10 (particles with an aerodynamic diameter below 10 μm), during the winter period for 3 months (December 2009–March 2010). Particles masses were gravimetrically determined and the filters were analyzed by instrumental neutron activation analysis to assess their chemical composition. The water-soluble ion compositions of the collected particles were determined by Ion-exchange Chromatography. Principal component analysis was applied to the data set of chemical elements and soluble ions to assess the main sources of the air pollutants. The use of both analytical techniques provided information about elemental solubility, such as for potassium, which was important to differentiate sources.
Resumo:
A descriptive study was developed to monitor air fungal contamination in ten food units from hospitals. Fifty air samples of 250 litres were collected through impaction method. Samples were collected in food storage facilities, kitchen, food plating, canteen and also, outside premises, since this is the place regarded as reference. Simultaneously, environmental parameters were also monitored, including temperature and relative humidity through the equipment Babouc, LSI Sistems and according to the International Standard ISO 7726.
Resumo:
Clean air is a basic requirement of life. The Indoor Air Quality (IAQ) has been the object of several studies due to an increasing concern within the scientific community on the effects of indoor air quality upon health, especially as people tend to spend more time indoors than outdoors. The quality of air inside homes, offices, schools or other private and public buildings is an essential determinant of healthy life and people’s well-being. People can be exposed to contaminants by inhalation, ingestion and dermal contact. In the past, scientists have paid much attention to the study of exposure to outdoor air contaminants, because they have realised the seriousness of outdoor air pollution problems. However, each indoor microenvironment has unique characteristics, determined by the local outdoor air, specific building characteristics and indoor activities. Indeed, hazardous substances are emitted from buildings, construction materials and indoor equipment or due to human activities indoors.
Resumo:
As ameaças à segurança da informação, (INFOSEC) atentam contra a perda da respectiva confidencialidade, integridade e disponibilidade, pelo que as organizações são impelidas a implementar políticas de segurança, quer ao nível físico quer ao nível lógico, utilizando mecanismos específicos de defesa. O projecto Network Air Gap Controller (NAGC) foi concebido no sentido de contribuir para as questões da segurança, designadamente daquelas que se relacionam directamente com a transferência de informação entre redes de classificação de segurança diferenciadas ou de sensibilidades distintas, sem requisitos de comunicação em tempo real, e que mereçam um maior empenho nas condições de robustez, de disponibilidade e de controlo. Os organismos que, em razão das atribuições e competências cometidas, necessitam de fazer fluir informação entre este tipo de redes, são por vezes obrigados a realizar a transferência de dados com recurso a um processo manual, efectuado pelo homem e não pela máquina, que envolve dispositivos amovivéis, como sejam o CD, DVD, PEN, discos externos ou switches manuais. Neste processo, vulgarmente designado por Network Air Gap (NAG), o responsável pela transferência de dados deverá assumir de forma infalível, como atribuições intrínsecas e inalienáveis da função exercida, as garantias do cumprimento de um vasto conjunto de normas regulamentares. As regras estabelecidas desdobram-se em ferramentas e procedimentos que se destinam, por exemplo, à guarda em arquivo de todas as transferências efectuadas; à utilização de ferramentas de segurança (ex: antivírus) antes da colocação da informação na rede de classificação mais elevada; ao não consentimento de transferência de determinados tipos de ficheiro (ex: executáveis) e à garantia de que, em consonância com a autonomia que normalmente é delegada no elemento responsável pela operação das comunicações, apenas se efectuam transferências de informação no sentido da rede de classificação inferior para a rede de classificação mais elevada. Face ao valor da informação e do impacto na imagem deste tipo de organizações, o operador de comunicações que não cumpra escrupulosamente o determinado é inexoravelmente afastado dessas funções, sendo que o processo de apuramento de responsabilidades nem sempre poderá determinar de forma inequívoca se as razões apontam para um acto deliberado ou para factores não intencionais, como a inépcia, o descuido ou a fadiga. Na realidade, as actividades periódicas e rotineiras, tornam o homem propenso à falha e poderão ser incontornavelmente asseguradas, sem qualquer tipo de constrangimentos ou diminuição de garantias, por soluções tecnológicas, desde que devidamente parametrizadas, adaptadas, testadas e amadurecidas, libertando os recursos humanos para tarefas de manutenção, gestão, controlo e inspecção. Acresce que, para este tipo de organizações, onde se multiplicam o número de redes de entrada de informação, com diferentes classificações e actores distintos, e com destinatários específicos, a utilização deste tipo de mecanismos assume uma importância capital. Devido a este factor multiplicativo, impõe-se que o NAGC represente uma opção válida em termos de oferta tecnológica, designadamente para uma gama de produtos de baixíssimo custo e que possa desenvolver-se por camadas de contributo complementar, em função das reais necessidades de cada cenário.
Resumo:
Para a diminuição da dependência energética de Portugal face às importações de energia, a Estratégia Nacional para a Energia 2020 (ENE 2020) define uma aposta na produção de energia a partir de fontes renováveis, na promoção da eficiência energética tanto nos edifícios como nos transportes com vista a reduzir as emissões de gases com efeito de estufa. No campo da eficiência energética, o ENE 2020 pretende obter uma poupança energética de 9,8% face a valores de 2008, traduzindo-se em perto de 1800 milhões de tep já em 2015. Uma das medidas passa pela aposta na mobilidade eléctrica, onde se prevê que os veículos eléctricos possam contribuir significativamente para a redução do consumo de combustível e por conseguinte, para a redução das emissões de CO2 para a atmosfera. No entanto, esta redução está condicionada pelas fontes de energia utilizadas para o abastecimento das baterias. Neste estudo foram determinados os consumos de combustível e as emissões de CO2 de um veículo de combustão interna adimensional representativo do parque automóvel. É também estimada a previsão de crescimento do parque automóvel num cenário "Business-as-Usual", através dos métodos de previsão tecnológica para o horizonte 2010-2030, bem como cenários de penetração de veículos eléctricos para o mesmo período com base no método de Fisher- Pry. É ainda analisado o impacto que a introdução dos veículos eléctricos tem ao nível dos consumos de combustível, das emissões de dióxido de carbono e qual o impacto que tal medida terá na rede eléctrica, nomeadamente no diagrama de carga e no nível de emissões de CO2 do Sistema Electroprodutor Nacional. Por fim, é avaliado o impacto dos veículos eléctricos no diagrama de carga diário português, com base em vários perfis de carga das baterias. A introdução de veículos eléctricos em Portugal terá pouca expressão dado que, no melhor dos cenários haverão somente cerca de 85 mil unidades em circulação, no ano de 2030. Ao nível do consumo de combustíveis rodoviários, os veículos eléctricos poderão vir a reduzir o consumo de gasolina até 0,52% e até 0,27% no consumo de diesel, entre 2010 e 2030, contribuindo ligeiramente uma menor dependência energética externa. Ao nível do consumo eléctrico, o abastecimento das baterias dos veículos eléctricos representará até 0,5% do consumo eléctrico total, sendo que parte desse abastecimento será garantido através de centrais de ciclo combinado a gás natural. Apesar da maior utilização deste tipo de centrais térmicas para produção de energia, tanto para abastecimento das viaturas eléctricas, como para o consumo em geral, verifica-se que em 2030, o nível de emissões do sistema electroprodutor será cerca de 46% inferior aos níveis registados em 2010, prevendo-se que atinja as 0,163gCO2/kWh produzido pelo Sistema Electroprodutor Nacional devido à maior quota de produção das fontes de energia renovável, como o vento, a hídrica ou a solar.