4 resultados para 35th International Geological Congress 2016
em Repositório Científico do Instituto Politécnico de Lisboa - Portugal
Resumo:
Purpose: To describe orthoptic student satisfaction in a blended learning environment. Methods: Blended learning and teaching approaches that include a mix of sessions with elearning are being used since 2011/2012 involving final year (4th year) students from an orthoptic program. This approach is used in the module of research in orthoptics during the 1 semester. Students experienced different teaching approaches, which include seminars, tutorial group discussions and e-learning activities using the moodle platform. The Constructivist OnLine Learning Environment Survey (COLLES ) was applied at the end of the semester with 24 questions grouped in 6 dimensions with 4 items each: Relevance to professional practice, Reflection, Interactivity, Tutor support, Peer support and Interpretation. A 5-point Likert scale was used to score each individual item of the questionnaire (1 - almost never to 5 – almost always). The sum of items in each dimension ranged between 4 (negative perception) and 20 (positive perception). Results: Twenty-four students replied to the questionnaire. Positive points were related with Relevance (16.13±2.63), Reflection (16.46±2.45), Tutor support (16.29±2.10) and Interpretation (15.38±2.16). The majority of the students (n=18; 75%) think that the on-line learning is relevant to students’ professional practice. Critical reflections about learning contents were frequent (n=19; 79.17%). The tutor was able to stimulate critical thinking (n=21; 87.50%), encouraged students to participate (n=18; 75%) and understood well the student’s contributions (n=15; 62.50%). Less positive points were related with Interactivity (14.13±2.77) and Peer support (13.29±2.60). Response from the colleagues to ideas (n=11; 45.83%) and valorization of individual contributions (n=10; 41.67%) scored lower than other items. Conclusions: The flow back and forth between face-to-face and online learning situations helps the students to make critical reflections. The majority of the students are satisfied with a blended e-learning system environment. However, more work needs to be done to improve interactivity and peer support.
Resumo:
Purpose: The aims of this study were to compare angle of deviation, fusional vergence measurements and fusion reserve ratio between esophoria and exophoria. Methods: A cross-sectional study was performed in children with best-corrected visual acuity of 0.0 LogMAR in either eye, compensated heterophoria within 10 prism dioptres (PD), full ocular rotations, presence of fusional vergence and stereopsis (60 seconds of arc or better). Fusional amplitudes were compared between angle of deviation (2, 4, 6, 8 and 10 PD) in esophoria and exophoria. The fusion reserve ratio was calculated (to assess the effect of the underlying angle of deviation) as fusional convergence divided by prism alternating cover test measurements. Results: Two-hundred and eleven children (7.65±1.16 years) were recruited to this study. Exophoria was most common for near (n=181; 85.8%) and distance (n=20; 9.5%). Esophoria was present in 22 children for near (10.4%) and in 1 child for distance (0.5%). No significant differences were found between fusional amplitudes and angle of deviation for near (p>0.05). Children with exophoria of 10PD had a slight, but not, significant (p=0.264) increase in fusional convergence from 2PD (19.95±5.09) to 10PD (26.67±5.77). In esophoric children the variation of fusional convergence was smaller from 2P (25.00±0.00) to 10PD (22.50±3.54) and non significant (p=0.185). The fusion reserve ratio was significantly smaller in children with higher deviations (i.e. 10PD) for both esophoria (p=0.003) and exophoria (p>0.001). The fusion reserve ratio ranged between 12.50 (2PD) and 2.25±0.35 (10PD) for esophoria and between 9.98±2.55 (2PD) and 2.67±0.58 (10PD) for exophoria. Conclusions: Angle of deviation is not an efficient measure to predict fusional amplitudes. The fusion reserve ratio appears to be a better measurement to assess the effect of the underlying angle of deviation on fusional convergence. More studies are necessary to understand better the relationship between fusion amplitudes and angle of deviation.
Resumo:
Purpose: It is important to establish a differential diagnosis between the different types of nystagmus, in order to give the appropriate clinical approach to every situation and to improve visual acuity. The nystagmus is normally blocked when the eyes are positioned in a particular way. This makes the child adopt a posture of ocular torticollis that reduces the nistagmiformes movements, improving the vision in this position. A way to promote the blocking of the nystagmic movements is by using prismatic lenses with opposite bases, to block or minimize the oscillatory movements. This results in a vision improvement and it reduces the anomalous head position. There is limited research on the visual results in children with nystagmus after using prisms with opposing bases. Our aim is to describe the impact on the visual acuity (VA ) of theprescription prism lenses in a nystagmus patient starting at 3 months of age. Methods: Case report on thirty month old caucasian male infant, with normal growth and development for their age, with an early onset of horizontal nystagmus at 3 months of age. Ophthalmic examination included slit lamp examination, fundus, refractive study, electrophysiological and magnetic resonance tests, measurement of VA over time with the Teller Acuity Cards (TAC ) in the distance agreed for the age. At age ten months, the mother noted a persistent turn to the right of the child’s head, which became increasingly more severe along the months. There’s no oscillopcia. At 24 months, an atropine refraction showed the following refractive error: 0D.: -1,50, OS: -0,50 and prismatic lens adapting OD 8 Δ nasal base and OE 8 Δ temporal base. Results: Thirty month old child, with adequate development for their age, with onset of idiopatic horizontal nystagmus, at 3 months of age. Normal ocular fundus and magnetic ressoance without alterations, sub-normal results in electrophysiological tests and VA with values below normal for age. At 6 months OD 20/300; OE 20/400; OU 20/300. At 9 months OD 20/250; OE 20/300; OU 20/150 (TAC a 38 cm). At 18 months OD 20/200; OE 20/100; OU 20/80 (TAC at 38 cm), when the head is turned to the right and the eyes in levoversão, the nystagmus decreases in a “neutral” area. At 24 month, with the prismatic glasses, OD 20/200 OE 20/100, OU20/80 (TAC at 54 cm, reference value is 20/30 – 20/100 para OU e 20/40 – 20/100 monocular), there was an increase in the visual acuity. The child did visual stimulation with multimedia devices and using glasses. After adaptation of prisms: at 30 months VA (with Cambridge cards) OD e OE = 6/18. The child improved the VA and reduced the anomalous head position. There is also improvement in mobility and fine motricity. Conclusion: Prisms with opposing bases., were used in the treatment of idiopathic nystagmus. Said prisms were adapted to reduce the skewed position of the head, and to improve VA and binocular function. Monitoring of visual acuity and visual stimulation was done using electronic devices. Following the use of prismatic, the patient improved significantly VA and the anomalous head position was reduced.
Resumo:
Purpose: Stereopsis is the perception of depth based on retinal disparity. Global stereopsis depends on the process of random dot stimuli and local stereopsis depends on contour perception. The aim of this study was to correlate 3 stereopsis tests: TNO®, StereoTA B®, and Fly Stereo Acuity Test® and to study the sensitivity and correlation between them, using TNO® as the gold standard. Other variables as near convergence point, vergences, symptoms and optical correction were correlated with the 3 tests. Materials and Methods: Forty-nine students from Escola Superior de Tecnologia da Saúde de Lisboa (ESTeSL), aged 18-26 years old were included. Results: The stereopsis mean (standard-deviation-SD) values in each test were: TNO® = 87.04” ±84.09”; FlyTest® = 38.18” ±34.59”; StereoTA B® = 124.89’’ ±137.38’’. About the coefficient of determination: TNO® and StereoTA B® with R2 = 0.6 e TNO® and FlyTest® with R2 =0.2. Pearson correlation coefficient shows a positive correlation between TNO® and StereoTA B® (r = 0.784 with α = 0.01). Phi coefficient shows a strong and positive association between TNO® and StereoTA B® (Φ = 0.848 with α = 0.01). In the ROC Curve, the StereoTA B® has an area under the curve bigger than the FlyTest® with a sensivity of 92.3% for 94.4% of specificity, so it means that the test is sensitive with a good discriminative power. Conclusion: We conclude that the use of Stereopsis tests to study global Stereopsis are an asset for clinical use. This type of test is more sensitive, revealing changes in Stereopsis when it is actually changed, unlike the test Stereopsis, which often indicates normal Stereopsis, camouflaging a Stereopsis change. We noted also that the StereoTA B ® is very sensitive and despite being a digital application, possessed good correlation with the TNO®.