29 resultados para 10 kV

em Repositório Científico do Instituto Politécnico de Lisboa - Portugal


Relevância:

60.00% 60.00%

Publicador:

Resumo:

A new circuit topology is proposed to replace the actual pulse transformer and thyratron based resonant modulator that supplies the 60 kV target potential for the ion acceleration of the On-Line Isotope Mass Separator accelerator, the stability of which is critical for the mass resolution downstream separator, at the European Organization for Nuclear Research. The improved modulator uses two solid-state switches working together, each one based on the Marx generator concept, operating as series and parallel switches, reducing the stress on the series stacked semiconductors, and also as auxiliary pulse generator in order to fulfill the target requirements. Preliminary results of a 10 kV prototype, using 1200 V insulated gate bipolar transistors and capacitors in the solid-state Marx circuits, ten stages each, with an electrical equivalent circuit of the target, are presented, demonstrating both the improved voltage stability and pulse flexibility potential wanted for this new modulator.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This paper describes the operation of a solid-state series stacked topology used as a serial and parallel switch in pulsed power applications. The proposed circuit, developed from the Marx generator concept, balances the voltage stress on each series stacked semiconductor, distributing the total voltage evenly. Experimental results from a 10 kV laboratory series stacked switch, using 1200 V semiconductors in a ten stages solid-state series stacked circuit, are reported and discussed, considering resistive, capacitive and inductive type loads for high and low duty factor voltage pulse operation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The preliminary results from a bipolar industrial solidstate based Marx generator, developed for the food industry, capable of delivering 25 kV/250 A positive and negative pulses with 12 kW average power, are presented and discussed. This modular topology uses only four controlled switches per cell, 27 cells in total that can be charged up to 1000V each, the two extra cells are used for droop compensation. The triggering signals for all the switches are generated by a FPGA. Considering that biomaterials are similar to resistive type loads, experimental results from this new bipolar 25 kV modulator into resistive loads are presented and discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Actualmente, é notável um interesse crescente relativamente ao estudo de insectos: interesses agrícolas (controlo de pragas) e interesses forenses (entomologia forense). A análise histológica destes organismos visa completar os conhecimentos já adquiridos. Objectivos gerais: obter lâminas histológicas de insectos. Objectivos específicos: determinar qual o fixador mais adequado, centrando as opções no Formol Tamponado a 10% (FT), Líquido de Bouin (LB) e Bouin Holland (BH); verificar se o processamento histológico de rotina se aplica ao estudo de insectos.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The intensive use of semiconductor devices enabled the development of a repetitive high-voltage pulse-generator topology from the dc voltage-multiplier (VM) concept. The proposed circuit is based on an odd VM-type circuit, where a number of dc capacitors share a common connection with different voltage ratings in each one, and the output voltage comes from a single capacitor. Standard VM rectifier and coupling diodes are used for charging the energy-storing capacitors, from an ac power supply, and two additional on/off semiconductors in each stage, to switch from the typical charging VM mode to a pulse mode with the dc energy-storing capacitors connected in series with the load. Results from a 2-kV experimental prototype with three stages, delivering a 10-mu s pulse with a 5-kHz repetition rate into a resistive load, are discussed. Additionally, the proposed circuit is compared against the solid-state Marx generator topology for the same peak input and output voltages.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An experimental and theoretical study of the electro-rheological effects observed in the nematic phase of 4-n-heptyl-4'-cyanobiphenyl has been conducted. This liquid crystal appears to be a model system, in which the observed rheological behaviour can be interpreted by the Leslie-Ericksen continuum theory for low molecular weight liquid crystals. Flow curves are illustrated at different temperatures and under the influence of an external electric field ranging from 0 to 3 kV mm-1, applied perpendicular to the direction of flow. Also presented is the apparent viscosity as a function of temperature, over similar values of electric field, obtained at different shear rates. A master flow curve has been constructed for each temperature by dividing the shear rate by the square of the electric field and multiplying by the square of a reference value of electric field. In a log-log plot, two Newtonian plateaux are found to appear at low and high shear rates, connected by a shear-thinning region. We have applied the Leslie-Ericksen continuum theory, in which the director alignment angle is a function of the electric field and the flow field boundary conditions are neglected, to determine viscoelastic parameters and the dielectric anisotropy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper addresses the voltage droop compensation associated with long pulses generated by solid-stated based high-voltage Marx topologies. In particular a novel design scheme for voltage droop compensation in solid-state based bipolar Marx generators, using low-cost circuitry design and control, is described. The compensation consists of adding one auxiliary PWM stage to the existing Marx stages, without changing the modularity and topology of the circuit, which controls the output voltage and a LC filter that smoothes the voltage droop in both the positive and negative output pulses. Simulation results are presented for 5 stages Marx circuit using 1 kV per stage, with 1 kHz repetition rate and 10% duty cycle.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this paper is to present and discuss a general HV topology of the solid-state Marx modulator, for unipolar or bipolar generation connected with a step-up transformer to increase the output voltage applied to a resistive load. Due to the use of an output transformer, discussion about the reset of the transformer is made to guarantee zero average voltage applied to the primary. It is also discussed the transformer magnetizing energy recovering back to the energy storage capacitors. Simulation results for a circuit that generates 100 kV pulses using 1000 V semiconductors are presented and discussed regarding the voltage and current stress on the semiconductors and result obtained.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The compounds [mPTA][CoCl4] (1, mPTA = N-methyl-1,3,5-triaza-7-phosphaadamantane cation), [CoCl(H2O)(DION)(2)][BF4] (2, DION = 1,10-phenanthroline-5,6-dione), [Zn(DION)(2)]Cl-2 (3) and [ZnCl(O-PTA=O)(DION)][BF4] (4) were synthesized by reaction of CoCl2 with [mPTA]I or DION and ZnCl2 with DION or 1,3,5-triaza-7-phosphaadamantane-7-oxide (PTA=O) and DION, respectively. All complexes are water soluble and have been characterized by IR, far-IR, H-1, C-13 and P-31{H-1} NMR spectroscopy, ESI-MS, elemental analyses and single-crystal X-ray diffraction structural analysis (for 1). They were screened against the human tumour cell lines HCT116, HepG2 and MCF7. Complexes 2 and 3 exhibit the highest in vitro cytotoxicity and show lower cytotoxic activities in normal human fibroblast cell line than in HCT116 tumour cell line, which demonstrates their slight specificity for this type of tumour cell.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Polymorphisms located in genes involved in the metabolism of folate and some methyl-related nutrients are implicated in colorectal cancer (CRC). Objective: We evaluated the association of 3 genetic polymorphisms [C677T MTHFR (methylene tetrahydrofolate reductase), A2756G MTR (methionine synthase), and C1420T SHMT (serine hydroxymethyltransferase)] with the intake of methyl-donor nutrients in CRC risk. Design: Patients withCRC(n 196) and healthy controls (n 200) matched for age and sex were evaluated for intake of methyl-donor nutrients and the 3 polymorphisms. Results: Except for folate intake, which was significantly lower in patients (P 0.02), no differences were observed in the dietary intake of other methyl-donor nutrients between groups. High intake of folate ( 406.7 g/d) was associated with a significantly lower risk of CRC (odds ratio: 0.67; 95% CI: 0.45, 0.99). The A2756G MTR polymorphism was not associated with the risk of developing CRC. In contrast, homozygosity for the C677TMTHFRvariant (TT) presented a 3.0-fold increased risk of CRC (95% CI: 1.3, 6.7). Similarly, homozygosity for the C1420T SHMT polymorphism also had a 2.6-fold increased risk (95% CI: 1.1, 5.9) of developing CRC. When interactions between variables were studied, low intake of all methyl-donor nutrients was associated with an increased risk ofCRC in homozygous participants for the C677T MTHFR polymorphism, but a statistically significant interaction was only observed for folate (odds ratio: 14.0; 95% CI: 1.8, 108.5). No significant associations were seen for MTR or SHMT polymorphisms. Conclusion: These results show an association between the C677T MTHFR variant and different folate intakes on risk of CRC.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: Samples from different environmental sources were screened for the presence of Aspergillus, and the distribution of the different species-complexes was determined in order to understand differences among that distribution in the several environmental sources and which of these species complexes are present in specific environmental settings. Methods: Four distinct environments (beaches, poultries, swineries and hospital) were studied and analyzed for which Aspergillus complexes were present in each setting. After plate incubation and colony isolation, morphological identification was done using macro- and microscopic characteristics. The universal fungal primers ITS1 and ITS4 were used to amplify DNA from all Aspergillus isolates, which was sequenced for identification to species complex level. SPSS v15.0 for Windows was used to perform the statistical analysis. Results: Thirty-nine isolates of Aspergillus were recovered from both the sand beach and poultries, 31 isolates from swineries, and 80 isolates from hospital environments, for a total 189 isolates. Eleven species complexes were found total. Isolates belonging to the Aspergillus Versicolores species-complex were the most frequently found (23.8%), followed by Flavi (18.0%), Fumigati (15.3%) and Nigri (13.2%) complexes. A significant association was found between the different environmental sources and the distribution of the several species-complexes (p<0.001); the hospital environment had a greater variability of species-complexes than other environmental locations (10 in hospital environment, against nine in swine, eight in poultries and seven in sand beach). Isolates belonging to Nidulantes complex were detected only in the hospital environment, whereas the other complexes were identified in more than one setting. Conclusion: Because different Aspergillus complexes have different susceptibilities to antifungal drugs, and different abilities in producing mycotoxins, knowledge of the species-complex epidemiology for each setting may allow preventive or corrective measures to be taken toward decreasing professional workers or patient exposure to those agents.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose - This study aims to investigate the influence of tube potential (kVp) variation in relation to perceptual image quality and effective dose (E) for pelvis using automatic exposure control (AEC) and non-AEC in a Computed Radiography (CR) system. Methods and materials - To determine the effects of using AEC and non-AEC by applying the 10 kVp rule in two experiments using an anthropomorphic pelvis phantom. Images were acquired using 10 kVp increments (60–120 kVp) for both experiments. The first experiment, based on seven AEC combinations, produced 49 images. The mean mAs from each kVp increment were used as a baseline for the second experiment producing 35 images. A total of 84 images were produced and a panel of 5 experienced observers participated for the image scoring using the two alternative forced choice (2AFC) visual grading software. PCXMC software was used to estimate E. Results - A decrease in perceptual image quality as the kVp increases was observed both in non-AEC and AEC experiments, however no significant statistical differences (p > 0.05) were found. Image quality scores from all observers at 10 kVp increments for all mAs values using non-AEC mode demonstrates a better score up to 90 kVp. E results show a statistically significant decrease (p = 0.000) on the 75th quartile from 0.37 mSv at 60 kVp to 0.13 mSv at 120 kVp when applying the 10 kVp rule in non-AEC mode. Conclusion - Using the 10 kVp rule, no significant reduction in perceptual image quality is observed when increasing kVp whilst a marked and significant E reduction is observed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Clinical and environmental samples from Portugal were screened for the presence of Aspergillus and the distributions of the species complexes were determined in order to understand how their distributions differ based on their source. Fifty-seven Aspergillus isolates from clinical samples were collected from 10 health institutions. Six species complexes were detected by internal transcribed spacer sequencing; Fumigati, Flavi, and Nigri were found most frequently (50.9%, 21.0%, and 15.8%, respectively). β-tubulin and calmodulin sequencing resulted in seven cryptic species (A. awamorii, A. brasiliensis, A. fructus, A. lentulus, A. sydowii, A. tubingensis, Emericella echinulata) being identified among the 57 isolates. Thirty-nine isolates of Aspergillus were recovered from beach sand and poultry farms, 31 from swine farms, and 80 from hospital environments, for a total 189 isolates. Eleven species complexes were found in these 189 isolates, and those belonging to the Versicolores species complex were found most frequently (23.8%). There was a significant association between the different environmental sources and distribution of the species complexes; the hospital environment had greater variability of species complexes than other environmental locations. A high prevalence of cryptic species within the Circumdati complex was detected in several environments; from the isolates analyzed, at least four cryptic species were identified, most of them growing at 37ºC. Because Aspergillus species complexes have different susceptibilities to antifungals, knowing the species-complex epidemiology for each setting, as well as the identification of cryptic species among the collected clinical isolates, is important. This may allow preventive and corrective measures to be taken, which may result in decreased exposure to those organisms and a better prognosis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose - To compare the image quality and effective dose applying the 10 kVp rule with manual mode acquisition and AEC mode in PA chest X-ray. Method - 68 images (with and without lesions) were acquired using an anthropomorphic chest phantom using a Wolverson Arcoma X-ray unit. These images were compared against a reference image using the 2 alternative forced choice (2AFC) method. The effective dose (E) was calculated using PCXMC software using the exposure parameters and the DAP. The exposure index (lgM provided by Agfa systems) was recorded. Results - Exposure time decreases more when applying the 10 kVp rule with manual mode (50%–28%) when compared with automatic mode (36%–23%). Statistical differences for E between several ionization chambers' combinations for AEC mode were found (p = 0.002). E is lower when using only the right AEC ionization chamber. Considering the image quality there are no statistical differences (p = 0.348) between the different ionization chambers' combinations for AEC mode for images with no lesions. Considering lgM values, it was demonstrated that they were higher when the AEC mode was used compared to the manual mode. It was also observed that lgM values obtained with AEC mode increased as kVp value went up. The image quality scores did not demonstrate statistical significant differences (p = 0.343) for the images with lesions comparing manual with AEC mode. Conclusion - In general the E is lower when manual mode is used. By using the right AEC ionising chamber under the lung the E will be the lowest in comparison to other ionising chambers. The use of the 10 kVp rule did not affect the visibility of the lesions or image quality.