5 resultados para 1 sigma standard deviation for the average
em Repositório Científico do Instituto Politécnico de Lisboa - Portugal
Resumo:
We present a palaeomagnetic study on 38 lava flows and 20 dykes encompassing the past 1.3 Myr on S. Jorge Island (Azores ArchipelagoNorth Atlantic Ocean). The sections sampled in the southeastern and central/western parts of the island record reversed and normal polarities, respectively. They indicate a mean palaeomagnetic pole (81.3 degrees N, 160.7 degrees E, K= 33 and A95= 3.4 degrees) with a latitude shallower than that expected from Geocentric Axial Dipole assumption, suggesting an effect of non-dipolar components of the Earth magnetic field. Virtual Geomagnetic Poles of eight flows and two dykes closely follow the contemporaneous records of the Cobb Mountain Subchron (ODP/DSDP programs) and constrain the age transition from reversed to normal polarity at ca. 1.207 +/- 0.017 Ma. Volcano flank instabilities, probably related to dyke emplacement along an NNWSSE direction, led to southwestward tilting of the lava pile towards the sea. Two spatially and temporally distinct dyke systems have been recognized on the island. The eastern is dominated by NNWSSE trending dykes emplaced before the end of the Matuyama Chron, whereas in the central/western parts the eruptive fissures oriented WNWESE controlled the westward growth of the S. Jorge Island during the Brunhes Chron. Both directions are consistent with the present-day regional stress conditions deduced from plate kinematics and tectonomorphology and suggest the emplacement of dykes along pre-existing fractures. The distinct timing and location of each dyke system likely results from a slight shift of the magmatic source.
Resumo:
We propose a low complexity technique to generate amplitude correlated time-series with Nakagami-m distribution and phase correlated Gaussian-distributed time-series, which is useful for the simulation of ionospheric scintillation effects in GNSS signals. To generate a complex scintillation process, the technique requires solely the knowledge of parameters Sa (scintillation index) and σφ (phase standard deviation) besides the definition of models for the amplitude and phase power spectra. The concatenation of two nonlinear memoryless transformations is used to produce a Nakagami-distributed amplitude signal from a Gaussian autoregressive process.
Resumo:
We propose a low complexity technique to generate amplitude correlated time-series with Nakagami-m distribution and phase correlated Gaussian-distributed time-series, which is useful in the simulation of ionospheric scintillation effects during the transmission of GNSS signals. The method requires only the knowledge of parameters S4 (scintillation index) and σΦ (phase standard deviation) besides the definition of models for the amplitude and phase power spectra. The Zhang algorithm is used to produce Nakagami-distributed signals from a set of Gaussian autoregressive processes.
Resumo:
Quando aplicada no âmbito da Anatomia Patológica, a imuno-histoquímica tem constituído um poderoso meio de identificação/caracterização de várias estruturas histológicas, permitindo delinear prognóstico e terapêutica para várias patologias. Tendo em conta que as amostras histológicas analisadas podem ser conservadas ao longo de vários anos, interessa avaliar a manutenção da antigenicidade ao longo do tempo, de forma a garantir a qualidade final da técnica quando aplicada em material de arquivo. Assim, o principal objetivo deste trabalho foi comparar a imunorreatividade do material histológico arquivado durante um, quatro e sete anos. Foi utilizado material histológico de próstata, pulmão e mama, no qual se procedeu à imunomarcação de citoqueratinas (Clones AE1/AE3), CD34 e proteína p63, por método de multímero/HRP no sistema Ventana BenchMark Ultra®. Foi realizado um ensaio com recuperação antigênica por alta temperatura (RAAT) e outro sem esta etapa. As imunomarcações (n=162) foram classificadas por três avaliadores independentes num escore quantitativo final (escala 0-100). O par média/desvio-padrão do escore final para os casos com sete anos foi de 69,06/19,05, para os casos com quatro anos foi de 66,47/20,73 e para os casos com um ano foi de 69,08/19,35, não se tendo encontrado diferenças estatisticamente significativas. Os casos sem RAAT obtiveram um par média/desvio-padrão de 54,90/17,00, enquanto os casos com RAAT obtiveram 81,50/11,60, o que revelou diferenças estatisticamente significativas (p=0,000). Para os casos em estudo conclui-se que o fator “tempo de arquivo” não está associado a alterações da imunorreatividade. A importância da RAAT na obtenção de imunomarcação de qualidade sai fortemente realçada. ABSTRACT - When applied within the framework of Pathology, immunohistochemistry has been a powerful means of identification/characterization of various histological structures, allowing to outline prognosis and therapy for various diseases. Given that the analyzed histological samples can be preserved for several years, it is interesting to assess the retention of antigenicity over time in order to ensure the quality of the final technique, when applied to stored material. Thus, the main objective of this study was to compare the immunoreactivity of the histological material archived for one, four and seven years. It was used histological material from prostate, lung and breast, in which it was performed the immunostaining of cytokeratins (clones AE1/AE3), CD34 and p63 protein by the method of multimer/HRP system on a Ventana BenchMark Ultra®. It was conducted a test with heat induced epitope retrieval (HIER) and another one without this step. The stained slides (n=162) were classified by three independent assessors using a quantitative score (scale 0-100). The pair mean/standard deviation of the score for cases with seven years was 69,06/19,05, for cases with four years was 66,47/20,73 and for cases with one year was 69,08/19,35, which did not revealed any statistically significant differences. The cases without HIER had a couple mean/standard deviation of 54.90/17.00 while the cases with HIER obtained 81.50/11.60, which revealed statistically significant differences (p=0.000). For this case study it was concluded that the factor archive period is not associated with changes in immunoreactivity. The importance of HIER in obtaining high quality immunostaining comes out strongly highlighted.
Resumo:
Desde o início da utilização da imunohistoquímica em anatomia patológica, um dos objetivos tem sido detetar as quantidades mais ínfimas de antigénio, tornando-o visível ao microscópio ótico. Vários sistemas de amplificação têm sido aplicados de forma a concretizar este objetivo, tendo surgido um grupo genérico de métodos simples e que apresentam uma amplificação superior: são os denominados métodos do polímero indireto. Tendo em conta a variedade de métodos disponíveis, o autor propõe-se a comparar a qualidade de quatro sistemas de amplificação, que recorrem ao método do polímero indireto com horseradish peroxidase (HRP). Foram utilizadas lâminas de diferentes tecidos, fixados em formol e incluídos em parafina, nos quais se procedeu à identificação de 15 antigénios distintos. Na amplificação recorreu-se a quatro sistemas de polímero indireto (Dako EnVision+ System – K4006; LabVision UltraVision LP Detection System – TL-004-HD; Leica NovoLink – RE7140-k; Vector ImmPRESS Reagent Kit – MP-7402). A observação microscópica e classificação da imunomarcação obtida foram feitas com base num algoritmo que enquadra intensidade, marcação específica, marcação inespecífica e contraste, num score global que pode tomar valores entre 0 e 25. No tratamento dos dados, para além da estatística descritiva, foi utilizado o teste one-way ANOVA com posthoc de tukey (alfa=0.05). O melhor resultado obtido, em termos de par média/desvio-padrão, dos scores globais foi o do NovoLink (22,4/2,37) e o pior foi o do EnVision+ (17,43/3,86). Verificou-se ainda que existe diferença estatística entre os resultados obtidos pelo sistema NovoLink e os sistemas UltraVision (p=.004), ImmPRESS (p=.000) e EnVision+ (p=.000). Concluiu-se que o sistema que permitiu a obtenção de melhores resultados, neste estudo, foi o Leica NovoLink.