129 resultados para Occupational exposure limits
Resumo:
Indoor air quality recently entered legislation in Portugal. Several parameters must be evaluated and kept within limits in order to obtain a certification for air quality and energy consumption. Certification parameters were analyzed in two Portuguese archives in order to assess indoor air quality both for people attending or working on these premises and for maintenance of a written heritage that must be retained for future generations. Carbon monoxide (CO) and carbon dioxide (CO2), formaldehyde, and fungal counts were kept within stipulated limits. Relative humidity (RH), volatile organic compounds (VOC), particulate matter (PM10), and ozone (O3) showed values above legislated levels and justified the implementation of corrective measures. In terms of conservation, studies on the limit values are still needed, but according to the available international guidelines, some of the analyzed parameters such as PM10, O3, and RH were also above desirable values. Corrective measures were proposed to these institutions. Although this study was only of a short duration, it proved valuable in assessing potential eventual problems and constitutes the first Portuguese indoor air quality assessment taking into consideration both aspects of an archive such as human health and heritage safekeeping.
Resumo:
The production of MVOC by fungi has been taken into account especially from the viewpoint of indoor pollution with microorganisms but the relevance of fungal metabolites in working environments has not been sufficiently studied. The purpose of this study was to assess exposure to MVOCs in a waste-handling unit. It was used Multirae equipment (RAE Systems) to measured MVOCs concentration with a 10.6 eV lamps. The measurements were done near workers nose and during the normal activities. All measurements were done continuously and had the duration of 5 minutes at least. It was consider the higher value obtained in each measurement. In addition, for knowing fungi contamination, five air samples of 50 litres were collected through impaction method at 140 L/minute, at one meter tall, on to malt extract agar with the antibiotic chloramphenicol (MEA). MVOCs results range between 4.7 ppm and 8.9 ppm in the 6 locations consider. These results are eight times higher than normally obtained in indoor settings. Considering fungi results, two species were identified in air, being the genera Penicillium found in all the samples in uncountable colonies and Rhizopus only in one sample (40 UFC/m3). These fungi are known as MVOCs producers, namely terpenoids, ketones, alcohols and others. Until now, there has been no evidence that MVOCs are toxicologically relevant, but further epidemiological research is necessary to elucidate their role on human’s health, particularly in occupational settings where microbiological contamination is common. Additionally, further research should concentrate on quantitative analyses of specific MVOCs.
Resumo:
Dust is a complex mixture of particles of organic and inorganic origin and different gases absorbed in aerosol droplets. In a poultry unit include dried faecal matter and urine, skin flakes, ammonia, carbon dioxide, pollens, feed and litter particles, feathers, grain mites, fungi spores, bacteria, viruses and their constituents. Dust particles vary in size and differentiation between particle size fractions is important in health studies in order to quantify penetration within the respiratory system. A descriptive study was developed in order to assess exposure to particles in a poultry unit during different operations, namely routine examination and floor turn over. Direct-reading equipment was used (Lighthouse, model 3016 IAQ). Particle measurement was performed in 5 different sizes (PM0.5; PM1.0; PM2.5; PM5.0; PM10). The chemical composition of poultry litter was also determined by neutron activation analysis. Normally, the litter of poultry pavilions is turned over weekly and it was during this operation that the higher exposure of particles was observed. In all the tasks considered PM5.0 and PM10.0 were the sizes with higher concentrations values. PM10 is what turns out to have higher values and PM0.5 the lowest values. The chemical element with the highest concentration was Mg (5.7E6 mg.kg-1), followed by K (1.5E4 mg.kg-1), Ca (4.8E3 mg.kg-1), Na (1.7E3 mg.kg-1), Fe (2.1E2 mg.kg-1) and Zn (4.2E1 mg.kg-1). This high presence of particles in the respirable range (<5–7μm) means that poultry dust particles can penetrate into the gas exchange region of the lung. Larger particles (PM10) present a range of concentrations from 5.3E5 and 3.0E6 mg/m3.
Resumo:
Poor air quality in a pig-confinement building may potentially place farmers at higher health risk than other workers for exposure to airborne pollutants that may reach infectious levels. The aim of this study was to assess worker exposure to fungi in indoor environments in Portuguese swine buildings. Air samples from 7 swine farms were collected at a flow rate of 140 L/min, at 1 m height, onto malt extract agar supplemented with chloramphenicol (MEA). Surfaces samples of the same indoor sites were obtained by swabbing the surfaces. Samples from the floor covering were also collected from four of seven swine farms. All collected samples were incubated at 27°C for 5-7 days. After lab processing and incubation of obtained samples, quantitative colony-forming units (CFU)/m(3), CFU/cm(2), and CFU/g and qualitative results were determined with identification of isolated fungal species. Aspergillus versicolor was the most frequent species found in air (21%), followed by Scopulariopsis brevicaulis (17%) and Penicillium sp. (14%). Aspergillus versicolor was also the most frequent species noted on surfaces (26.6%), followed by Cladosporium sp. (22.4%) and Scopulariopsis brevicaulis (17.5%). Chrysosporium was the most frequently found genera in the new floor covering (38.5%), while Mucor was the most prevalent genera (25.1%) in used floor covering. Our findings corroborate a potential occupational health threat due to fungi exposure and suggest the need for a preventive strategy.
Resumo:
Several studies have shown that human exposures to airbome dust and microorganisms, such as bacteria and fungi, can cause respiratory diseases. Agricultural workers have been found to be at high risk of exposures to airborne particles. From a human health perspective dust exposure in pig farming is the most important risk because of the large number of workers needed in pig production and the increasing number of working hours inside enclosed buildings. In the pig buildings, particulate matters like dust play a role in not only deteriorating indoor air quality but also can cause an adverse health effect on workers. Generally, dust is recognized to adsorb and transport odorous compounds and biological agents. The aim of this study was to determine particles contamination in 7 swine farms located in Lisbon district, Portugal.
Resumo:
Agricultural workers especially poultry farmers are at increased risk of occupational respiratory diseases. Epidemiological studies showed increased prevalence of respiratory symptoms and adverse changes in pulmonary function parameters in poultry workers. In poultry production volatile organic compounds (VOCs) presence can be due to some compounds produced by molds that are volatile and are released directly into the air. These are known as microbial volatile organic compounds (MVOCs). Because these compounds often have strong and/or unpleasant odors, they can be the source of odors associated with molds. MVOC's are products of the microorganisms primary and secondary metabolism and are composed of low molecular weight alcohols, aldehydes, amines, ketones, terpenes, aromatic and chlorinated hydrocarbons, and sulfur-based compounds, all of which are variations of carbon-based molecules.
Resumo:
Composting is an important process of solid waste management and it can be used for treatment of a variety of different wastes (green waste, household waste, sewage sludge and more). This process aims to: 1. Reduce the volumes of waste and; 2. Create a valuable product which can be recycled as a soil amendment in agriculture and gardening. A natural self-heating process involving the biological degradation of organic matter under aerobic conditions. The handling of waste and compost is responsible for the release of airborne microorganisms and their compounds in the air. Possible contaminants: a) Dust; b) Mesophilic and thermophilic microorganisms; c) Volatile organic compounds; d) Endotoxins and mycotoxins…. Aim: assess exposure/contamination to: a) Volatile organic compounds (VOCs); b) Particulate matter (PM); c) Fungi. In a composting plant located in Lisbon. An additional goal was to identify the workplace with higher level of contamination. In a totally indoor composting plant. The composting operations consisted: 1º Waste already sorted is unloaded in a reception area; 2º Pretreatment - remove undesirable materials from the process (glass, rocks, plastics, metals…); 3º Anaerobic digestion; 4º Dehydration; 5º Open composting with forced aeration. All the process takes thirteen weeks.
Resumo:
Conferência: 9th International Symposium on Occupational Safety and Hygiene (SHO) Guimaraes, Portugal - FEB 14-15, 2013
Resumo:
Antioneoplastic drugs are widely used in treatment of cancer, and several studies suggest acute and long-term effects associated to antineoplastic drug exposures, namely associating workplace exposure with health effects. Cytokinesis blocked micronucleus (CBMN) assay is one promising short-term genotoxicity assays for human risk assessment and their combination is recommended to monitor populations chronically exposed to genotoxic agents. The aim of this investigation is the genotoxicity assessment in different professionals that handle cytostatics drugs. This research is case-control blinded study constituted by 46 non-exposed subjects and 44 workers that handle antineoplastic drugs, such as pharmacists, pharmacy technicians, and nurses. It was found statistically significant increases in the genotoxicity biomarkers in exposed comparising with controls (p<0.05). The findings address the need for regular biomonitoring of personnel occupationally exposed to these drugs, confirming to an enhanced health risk assessment.