35 resultados para transit dosimetry


Relevância:

10.00% 10.00%

Publicador:

Resumo:

X-ray fluoroscopy is essential in both diagnosis and medical intervention, although it may contribute to significant radiation doses to patients that have to be optimised and justified. Therefore, it is crucial to the patient to be exposed to the lowest achievable dose without compromising the image quality. The purpose of this study was to perform an analysis of the quality control measurements, particularly dose rates, contrast and spatial resolution of Portuguese fluoroscopy equipment and also to provide a contribution to the establishment of reference levels for the equipment performance parameters. Measurements carried out between 2007 and 2013 on 143 fluoroscopy equipment distributed by 34 nationwide health units were analysed. The measurements suggest that image quality and dose rates of Portuguese equipment are congruent with other studies, and in general, they are as per the Portuguese law. However, there is still a possibility of improvements intending optimisation at a national level.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

TOD (Transit Oriented Development) is typically defined as a high density mixed area (residential and commercial) within easy walking distance of a high capacity public transport station (typically within an 800m buffer area). TOO is viewed as a set of strategies to increase the use of public transport, increasing walking activity, containing urban sprawl, and creating more liveable places. It is believed that this type of combined strategies will improve sustainable growth. This work is an exploratory work for evidence of TOD characteristics in train station areas in Azambuja train line, setting further methodologies to evaluate the success of TOD areas.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To compare image quality and effective dose when the 10 kVp rule is applied with manual and AEC mode in PA chest X-ray. Methods and Materials: A total of 68 images (with and without lesions) were acquired of an anthropomorphic chest phantom in a Wolverson Arcoma X-ray unit. The images were evaluated against a reference image using image quality criteria and the 2 alternative forced choice (2 AFC) method by five radiographers. The effective dose was calculated using PCXMC software using the exposure parameters and DAP. The exposure index (lgM) was recorded. Results: Exposure time decreases considerably when applying the 10 kVp rule in manual mode (50%-28%) compared to AEC mode (36%-23%). Statistical differences for effective dose between several AEC modes were found (p=0.002). The effective dose is lower when using only the right AEC ionization chamber. Considering image quality, there are no statistical differences (p=0.348) between the different AEC modes for images with no lesions. Using a higher kVp value the lgM values will also increase. The lgM values showed significant statistical differences (p=0.000). The image quality scores did not present statistically significant differences (p=0.043) for the images with lesions when comparing manual with AEC modes. Conclusion: In general, the dose is lower in the manual mode. By using the right AEC ionising chamber the effective dose will be the lowest in comparison to other ionising chambers. The use of the 10 kVp rule did not affect the detectability of the lesions.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction: multimodality environment; requirement for greater understanding of the imaging technologies used, the limitations of these technologies, and how to best interpret the results; dose optimization; introduction of new techniques; current practice and best practice; incidental findings, in low-dose CT images obtained as part of the hybrid imaging process, are an increasing phenomenon with advancing CT technology; resultant ethical and medico-legal dilemmas; understanding limitations of these procedures important when reporting images and recommending follow-up; free-response observer performance study was used to evaluate lesion detection in low-dose CT images obtained during attenuation correction acquisitions for myocardial perfusion imaging, on two hybrid imaging systems.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A TC é um valioso método diagnóstico radiológico. O exame TC pode expor o paciente a uma dose elevada de exposição à radiação, causando risco acrescido. Uma das possíveis soluções para a redução da dose é o uso de técnicas de reconstrução iterativa (IR) em vez das reconstruções tradicionais (FBP). Com base nas suas capacidades de redução de ruído na imagem, a IR pode ter o potencial de reduzir significativamente a dose em pacientes submetidos a TC sem prejudicar a qualidade de imagem. Manter a qualidade de imagem clínica com um nível de qualidade aceitável e expondo o paciente à menor dose possível.