55 resultados para political control


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The legacy of nineteenth century social theory followed a “nationalist” model of society, assuming that analysis of social realities depends upon national boundaries, taking the nation-state as the primary unit of analysis, and developing the concept of methodological nationalism. This perspective regarded the nation-state as the natural - and even necessary - form of society in modernity. Thus, the constitution of large cities, at the end of the 19th century, through the intense flows of immigrants coming from diverse political and linguistic communities posed an enormous challenge to all social research. One of the most significant studies responding to this set of issues was The Immigrant Press and its Control, by Robert E. Park, one of the most prominent American sociologists of the first half of the 20th century. The Immigrant Press and its Control was part of a larger project entitled Americanization Studies: The Acculturation of Immigrant Group into American Society, funded by the Carnagie Corporation following World War I, taking as its goal to study the so-called “Americanization methods” during the 1920s. This paper revisits that particular work by Park to reveal how his detailed analysis of the role of the immigrant press overcame the limitations of methodological nationalism. By granting importance to language as a tool uniting each community and by showing how the strength of foreign languages expressed itself through the immigrant press, Park demonstrated that the latter produces a more ambivalent phenomenon than simply the assimilation of immigrants. On the one hand, the immigrant press served as a connecting force, driven by the desire to preserve the mother tongue and culture while at the same time awakening national sentiments that had, until then, remained diffuse. Yet, on the other hand, it facilitated the adjustment of immigrants to the American context. As a result, Park’s work contributes to our understanding of a particular liminal moment inherent within many intercultural contexts, the space between emigrant identity (emphasizing the country of origin) and immigrant identity (emphasizing the newly adopted country). His focus on the role played by media in the socialization of immigrant groups presaged later work on this subject by communication scholars. Focusing attention on Park’s research leads to other studies of the immigrant experience from the same period (e.g., Thomas & Znaniecki, The Polish Peasant in Europe and America), and also to insights on multi-presence and interculturality as significant but often overlooked phenomena in the study of immigrant socialization.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Workplace aggression is a factor that shapes the interaction between individuals and their work environment and produces many undesirable outcomes, sometimes introducing heavy costs for organizations. Only through a comprehensive understanding of the genesis of workplace aggression is possible to develop strategies and interventions to minimize its nefarious effects. The existent body of knowledge has already identified several individual, situational and contextual antecedents of workplace aggression, although this is a research area where significant gaps occur and many issues were still not addressed Dupré and Barling (2006). According to Baron and Neuman (1998) one of these predictors is organizational change, since certain changes in the work environment (e.g., changes in management) can lead to increased aggression. This paper intends to contribute to workplace aggression research by studying its relationship with organizational change, considering a moderating role of political behaviors and organizational cynicism (Ammeter et al., 2002, Ferris et al., 2002). The literature review suggests that mediators and moderators that intervene in the relationships between workplace aggression and its antecedents are understudied topics. James (2005) sustains that organizational politics is related to cynicism and the empirical research of Miranda (2008) has identified leadership political behavior as an antecedent of cynicism but these two variables were not yet investigated regarding their relationship with workplace aggression. This investigation was operationalized using several scales including the Organizational Change Questionnaire-climate of change, processes, and readiness (Bouckenooghe, Devos and Broeck, 2009), a Workplace Aggression Scale (Vicente and D’Oliveira, 2008, 2009, 2010), an Organizational Cynicism Scale (Wanous, Reichers and Austin, 1994) and a Political Behavior Questionnaire (Yukl and Falbe, 1990). Participants representing a wide variety of jobs across many organizations were surveyed. The results of the study and its implications will be presented and discussed. This study contribution is also discussed in what concerns organizational change practices in organizations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

One of the main trends in workplace aggression research is studying its antecedents. But the literature also reveals that some predictors remain understudied, like organizational change [1]. Additionally, possible mediators of this relationship were not investigated. The main objective of this research is studding the mediating effect of the leader political behavior (soft and hard version) on the relationship between organizational change and workplace aggression. Participants representing a wide variety of jobs across many organizations were surveyed. The measures used in this research are an Organizational Change Questionnaire climate of change, processes, and readiness [2], a Workplace Aggression Scale [e.g. 3, 4] and a Political Behavior Questionnaire [5]. The results of the study and its theoretical and practical implications will be presented and discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a programable perturbation and observation control implementation for a wind generation system and its power electronic converter. The objective of the method in this particular application is to adjust the power delivered to charge a battery to its maximum and allowable value, function of the real values of several parameters and their continuous variation, the most important the wind velocity and the turbine efficiency. Also, to improve the power throughput and to use the turbine and generator marginal zones of operation, an unusual power converter is used, allowing a wide range for the input voltage values. The implemented control is continuously measuring the actual power and looks for a new and powerful operation point. © 2014 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fast Field Cycling (FFC) Nuclear Magnetic Resonance (NMR) relaxometers require controlled current sources in order to get accurate flux density with respect to its magnet. The main elements of the proposed solution are a power semiconductor, a DC voltage source and the magnet. The power semiconductor is commanded in order to get a linear control of the flux density. To implement the flux density control, a Hall Effect sensor is used. Furthermore, the dynamic behavior of the current source is analyzed and compared when using a PI controller and a PD2I controller.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a comparison between proportional integral control approaches for variable speed wind turbines. Integer and fractional-order controllers are designed using linearized wind turbine model whilst fuzzy controller also takes into account system nonlinearities. These controllers operate in the full load region and the main objective is to extract maximum power from the wind turbine while ensuring the performance and reliability required to be integrated into an electric grid. The main contribution focuses on the use of fractional-order proportional integral (FOPI) controller which benefits from the introduction of one more tuning parameter, the integral fractional-order, taking advantage over integer order proportional integral (PI) controller. A comparison between proposed control approaches for the variable speed wind turbines is presented using a wind turbine benchmark model in the Matlab/Simulink environment. Results show that FOPI has improved system performance when compared with classical PI and fuzzy PI controller outperforms the integer and fractional-order control due to its capability to deal with system nonlinearities and uncertainties. © 2014 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This article addresses the problem of obtaining reduced complexity models of multi-reach water delivery canals that are suitable for robust and linear parameter varying (LPV) control design. In the first stage, by applying a method known from the literature, a finite dimensional rational transfer function of a priori defined order is obtained for each canal reach by linearizing the Saint-Venant equations. Then, by using block diagrams algebra, these different models are combined with linearized gate models in order to obtain the overall canal model. In what concerns the control design objectives, this approach has the advantages of providing a model with prescribed order and to quantify the high frequency uncertainty due to model approximation. A case study with a 3-reach canal is presented, and the resulting model is compared with experimental data. © 2014 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper is about a hierarchical structure with an event-based supervisor in a higher level and a fractional-order proportional integral (FOPI) in a lower level applied to a wind turbine. The event-based supervisor analyzes the operation conditions to determine the state of the wind turbine. This controller operate in the full load region and the main objective is to capture maximum power generation while ensuring the performance and reliability required for a wind turbine to be integrated into an electric grid. The main contribution focus on the use of fractional-order proportional integral controller which benefits from the introduction of one more tuning parameter, the integral fractional-order, taking advantage over integer order proportional integral (PI) controller. Comparisons between fractional-order pitch control and a default proportional integral pitch controller applied to a wind turbine benchmark are given and simulation results by Matlab/Simulink are shown in order to prove the effectiveness of the proposed approach.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a programable perturbation and observation control implementation for a wind generation system and its power electronic converter. The objective of the method in this particular application is to adjust the power delivered to charge a battery to its maximum and allowable value, function of the real values of several parameters and their continuous variation, the most important the wind velocity and the turbine efficiency. Also, to improve the power throughput and to use the turbine and generator marginal zones of operation, an unusual power converter is used, allowing a wide range for the input voltage values. The implemented control is continuously measuring the actual power and looks for a new and powerful operation point. © 2014 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fast Field Cycling (FFC) Nuclear Magnetic Resonance (NMR) relaxometers require controlled current sources in order to get accurate flux density with respect to its magnet. The main elements of the proposed solution are a power semiconductor, a DC voltage source and the magnet. The power semiconductor is commanded in order to get a linear control of the flux density. To implement the flux density control, a Hall Effect sensor is used. Furthermore, the dynamic behavior of the current source is analyzed and compared when using a PI controller and a PD2I controller.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper is about a hierarchical structure with an event-based supervisor in a higher level and a fractional-order proportional integral (FOPI) in a lower level applied to a wind turbine. The event-based supervisor analyzes the operation conditions to determine the state of the wind turbine. This controller operate in the full load region and the main objective is to capture maximum power generation while ensuring the performance and reliability required for a wind turbine to be integrated into an electric grid. The main contribution focus on the use of fractional-order proportional integral controller which benefits from the introduction of one more tuning parameter, the integral fractional-order, taking advantage over integer order proportional integral (PI) controller. Comparisons between fractional-order pitch control and a default proportional integral pitch controller applied to a wind turbine benchmark are given and simulation results by Matlab/Simulink are shown in order to prove the effectiveness of the proposed approach.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a comparison between proportional integral control approaches for variable speed wind turbines. Integer and fractional-order controllers are designed using linearized wind turbine model whilst fuzzy controller also takes into account system nonlinearities. These controllers operate in the full load region and the main objective is to extract maximum power from the wind turbine while ensuring the performance and reliability required to be integrated into an electric grid. The main contribution focuses on the use of fractional-order proportional integral (FOPI) controller which benefits from the introduction of one more tuning parameter, the integral fractional-order, taking advantage over integer order proportional integral (PI) controller. A comparison between proposed control approaches for the variable speed wind turbines is presented using a wind turbine benchmark model in the Matlab/Simulink environment. Results show that FOPI has improved system performance when compared with classical PI and fuzzy PI controller outperforms the integer and fractional-order control due to its capability to deal with system nonlinearities and uncertainties. © 2014 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a new predictive digital control method applied to Matrix Converters (MC) operating as Unified Power Flow Controllers (UPFC). This control method, based on the inverse dynamics model equations of the MC operating as UPFC, just needs to compute the optimal control vector once in each control cycle, in contrast to direct dynamics predictive methods that needs 27 vector calculations. The theoretical principles of the inverse dynamics power flow predictive control of the MC based UPFC with input filter are established. The proposed inverse dynamics predictive power control method is tested using Matlab/Simulink Power Systems toolbox and the obtained results show that the designed power controllers guarantees decoupled active and reactive power control, zero error tracking, fast response times and an overall good dynamic and steady-state response.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents the design and compares the performance of linear, decoupled and direct power controllers (DPC) for three-phase matrix converters operating as unified power flow controllers (UPFC). A simplified steady-state model of the matrix converter-based UPFC fitted with a modified Venturini high-frequency pulse width modulator is first used to design the linear controllers for the transmission line active (P) and reactive (Q) powers. In order to minimize the resulting cross coupling between P and Q power controllers, decoupled linear controllers (DLC) are synthesized using inverse dynamics linearization. DPC are then developed using sliding-mode control techniques, in order to guarantee both robustness and decoupled control. The designed P and Q power controllers are compared using simulations and experimental results. Linear controllers show acceptable steady-state behaviour but still exhibit coupling between P and Q powers in transient operation. DLC are free from cross coupling but are parameter sensitive. Results obtained by DPC show decoupled power control with zero error tracking and faster responses with no overshoot and no steady-state error. All the designed controllers were implemented using the same digital signal processing hardware.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This article addresses the problem of obtaining reduced complexity models of multi-reach water delivery canals that are suitable for robust and linear parameter varying (LPV) control design. In the first stage, by applying a method known from the literature, a finite dimensional rational transfer function of a priori defined order is obtained for each canal reach by linearizing the Saint-Venant equations. Then, by using block diagrams algebra, these different models are combined with linearized gate models in order to obtain the overall canal model. In what concerns the control design objectives, this approach has the advantages of providing a model with prescribed order and to quantify the high frequency uncertainty due to model approximation. A case study with a 3-reach canal is presented, and the resulting model is compared with experimental data. © 2014 IEEE.