49 resultados para optical diagnosis


Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper we demonstrate an add/drop filter based on SiC technology. Tailoring of the channel bandwidth and wavelength is experimentally demonstrated. The concept is extended to implement a 1 by 4 wavelength division multiplexer with channel separation in the visible range. The device consists of a p-i'(a-SiC:H)-n/p-i(a-Si: H)-n heterostructure. Several monochromatic pulsed lights, separately or in a polychromatic mixture illuminated the device. Independent tuning of each channel is performed by steady state violet bias superimposed either from the front and back sides. Results show that, front background enhances the light-to-dark sensitivity of the long and medium wavelength channels and quench strongly the others. Back violet background has the opposite behaviour. This nonlinearity provides the possibility for selective removal or addition of wavelengths. An optoelectronic model is presented and explains the light filtering properties of the add/drop filter, under different optical bias conditions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this paper is the design of an optoelectronic circuit based on a-SiC technology, able to act simultaneously as a 4-bit binary encoder or a binary decoder in a 4-to-16 line configurations and show multiplexer-based logical functions. The device consists of a p-i'(a-SiC:H)-n/p-i(a-Si:H)-n multilayered structure produced by PECVD. To analyze it under information-modulated wave (color channels) and uniform irradiation (background) four monochromatic pulsed lights (input channels): red, green, blue and violet shine on the device. Steady state optical bias was superimposed separately from the front and the back sides, and the generated photocurrent was measured. Results show that the devices, under appropriate optical bias, act as reconfigurable active filters that allow optical switching and optoelectronic logic functions development providing the possibility for selective removal of useless wavelengths. The logic functions needed to construct any other complex logic functions are the NOT, and both or either an AND or an OR. Any other complex logic function that might be found can also be used as building blocks to achieve the functions needed for the retrieval of channels within the WDM communication link. (C) 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Visible range to telecom band spectral translation is accomplished using an amorphous SiC pi'n/pin wavelength selector under appropriate front and back optical light bias. Results show that background intensity works as selectors in the infrared region, shifting the sensor sensitivity. Low intensities select the near-infrared range while high intensities select the visible part according to its wavelength. Here, the optical gain is very high in the infrared/red range, decreases in the green range, stays close to one in the blue region and strongly decreases in the near-UV range. The transfer characteristics effects due to changes in steady state light intensity and wavelength backgrounds are presented. The relationship between the optical inputs and the output signal is established. A capacitive optoelectronic model is presented and tested using the experimental results. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents solutions for fault detection and diagnosis of two-level, three phase voltage-source inverter (VSI) topologies with IGBT devices. The proposed solutions combine redundant standby VSI structures and contactors (or relays) to improve the fault-tolerant capabilities of power electronics in applications with safety requirements. The suitable combination of these elements gives the inverter the ability to maintain energy processing in the occurrence of several failure modes, including short-circuit in IGBT devices, thus extending its reliability and availability. A survey of previously developed fault-tolerant VSI structures and several aspects of failure modes, detection and isolation mechanisms within VSI is first discussed. Hardware solutions for the protection of power semiconductors with fault detection and diagnosis mechanisms are then proposed to provide conditions to isolate and replace damaged power devices (or branches) in real time. Experimental results from a prototype are included to validate the proposed solutions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper an automatic classification algorithm is proposed for the diagnosis of the liver steatosis, also known as, fatty liver, from ultrasound images. The features, automatically extracted from the ultrasound images used by the classifier, are basically the ones used by the physicians in the diagnosis of the disease based on visual inspection of the ultrasound images. The main novelty of the method is the utilization of the speckle noise that corrupts the ultrasound images to compute textural features of the liver parenchyma relevant for the diagnosis. The algorithm uses the Bayesian framework to compute a noiseless image, containing anatomic and echogenic information of the liver and a second image containing only the speckle noise used to compute the textural features. The classification results, with the Bayes classifier using manually classified data as ground truth show that the automatic classifier reaches an accuracy of 95% and a 100% of sensitivity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Desde 1935 que tem sido demonstrada a relação entre a execução de um trabalho de perto prolongado e o aparecimento de queixas visuais astenópicas. Anomalias da VB encontram-se significativamente aumentadas ao fim de um dia de trabalho com fixação de perto. Diminuição significativa da amplitude de acomodação e convergência depois de quatro dias a realizar uma atividade de perto. Objectivo geral: avaliar o estado da visão binocular dos profissionais de Anatomia Patológica utilizadores de microscópio ótico. Objectivos específicos: identificar as queixas astenópicas mais frequentes dos profissionais durante o trabalho com o microscópio ótico; comparar o estado da VB no início e no final de uma semana de trabalho; correlacionar o estado da VB com as queixas astenópicas sentidas pelos profissionais; correlacionar as queixas astenópicas com as horas e o número de anos de trabalho com o microscópio.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work demonstrates the feasibility of using polymeric micro- and nanofiber-composed films and liquid crystals as electrically switchable scattering light shutters. We present a concept of electro-optic device based on an innovative combination of two mature technologies: optics of nematic liquid crystals and electrospinning of nanofibers. These devices have electric and optical characteristics far superior to other comparable methods. The simulation presented shows results that are highly consistent with those of experiments and that explain the working mechanism of the devices.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A swift chemical route to synthesize Co-doped SnO2 nanopowders is described. Pure and highly stable Sn1-xCoxO2-delta (0 <= x <= 0.15) crystalline nanoparticles were synthesized, with mean grain sizes <5 nm and the dopant element homogeneously distributed in the SnO2 matrix. The UV-visible diffuse reflectance spectra of the Sn1-xCoxO2-delta samples reveal red shifts, the optical bandgap energies decreasing with increasing Co concentration. The samples' Urbach energies were calculated and correlated with their bandgap energies. The photocatalytic activity of the Sn1-xCoxO2-delta samples was investigated for the 4-hydroxylbenzoic acid (4-HBA) degradation process. A complete photodegradation of a 10 ppm 4-HBA solution was achieved using 0.02% (w/w) of Sn0.95Co0.05O2-delta nanoparticles in 60 min of irradiation. (C) 2014 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report and analyze the halting of the fuse effect propagation in optical fiber microwires. The increase of the mode field diameter in the tapered region decreases the optical intensity resulting in the extinction of the fuse effect. This fiber element presents a low insertion loss and can be introduced in the optical network in order to protect the active equipment from the damage caused by the fuse effect.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The behavior of tandem pin heterojunctions based on a-SiC: H alloys is investigated under different optical and electrical bias conditions. The devices are optimized to act as optically selective wavelength filters. Depending on the device configuration (optical gaps, thickness, sequence of cells in the stack structure) and on the applied voltage (positive or negative) and optical bias (wavelength, intensity, frequency) it is possible to combine the wavelength discrimination function with the self amplification of the signal. This wavelength nonlinearity allows the amplification or the rejection of a weak signal-impulse. The device works as an active tunable optical filter for wavelength selection and can be used as an add/drop multiplexer (ADM) which enables data to enter and leave an optical network bit stream without having to demultiplex the stream. Results show that, even under weak transient input signals, the background wavelength controls the output signal. This nonlinearity, due to the transient asymmetrical light penetration of the input channels across the device together with the modification on the electrical field profile due to the optical bias, allows tuning an input channel without demultiplexing the stream. This high optical nonlinearity makes the optimized devices attractive for the amplification of all optical signals. Transfer characteristics effects due to changes in steady state light, control d.c. voltage and applied light pulses are presented. Based on the experimental results and device configuration an optoelectronic model is developed. The transfer characteristics effects due to changes in steady state light, dc control voltage or applied light pulses are simulated and compared with the experimental data. A good agreement was achieved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report and analyze the halting of the fuse effect propagation in optical fiber microwires. The increase of the mode field diameter in the tapered region decreases the optical intensity resulting in the extinction of the fuse effect. This fiber element presents a low insertion loss and can be introduced in the optical network in order to protect the active equipment from the damage caused by the fuse effect. (C) 2012 Optical Society of America

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Urinary tract infection (UTI) is one of the most prevalent pathologies in developed countries, particularly in women, characterized by the presence of bacterial growth in any part of the urinary system. Currently, urine culture is considered the gold standard method for the diagnosis of UTI. However, this method has several disadvantages including the time necessary for obtaining the results and the associated high costs. Therefore, it is important to evaluate new efficient and valuable methods for the diagnosis of these infections. Objectives: Presently, dipsticks are considered a possible valuable alternative to urine culture. This method has very low costs associated and the results can be obtained in few minutes. Here we aim to compare the sensibility, specificity, predictive value of a positive test and a negative test of both methods in order to determine the efficiency of the test strips method and also to characterize the microorganism more frequently isolated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: The samples obtained from fine needle aspiration in liquid base cytology (FNAC) are often limited by scarce cellularity compared to the amount of colloid and presence of blood. Accordingly, it was important to test alternative technical procedures so as to maximize the cellularity of each sample. Objective: To compare the morphological features and cellularity of the three procedures in the FNAC cytodiagnosis of the thyroid. Methods: A total of 31 cases were each subjected to a cell block and ThinPrep preparation as well as a routine smear. The observation and analysis was performed using an optical microscope. Cytological diagnosis of each cell block case was objectively analysed for cellularity, presence of background and cellular preservation. Each smear and ThinPrep case was analysed for the presence or absence of cells. The data was analysed with Microsoft Excel (Office 2010) and SPSS (Statistical Package of Social Science) version 15.0 for Windows. Results: Of 31 cases, only 20 had thyroid cells in the cell block and ThinPrep preparations, however, all smear cases contained thyroid cells. Some background was found in 30 Cell block cases with only 5 of these containing well preserved cells for cytodiagnosis. Conclusions: As indicated by the results, smear is the most appropriate procedure for FNAC of the thyroid.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The SiC optical processor for error detection and correction is realized by using double pin/pin a-SiC:H photodetector with front and back biased optical gating elements. Data shows that the background act as selector that pick one or more states by splitting portions of the input multi optical signals across the front and back photodiodes. Boolean operations such as exclusive OR (EXOR) and three bit addition are demonstrated optically with a combination of such switching devices, showing that when one or all of the inputs are present the output will be amplified, the system will behave as an XOR gate representing the SUM. When two or three inputs are on, the system acts as AND gate indicating the present of the CARRY bit. Additional parity logic operations are performed by use of the four incoming pulsed communication channels that are transmitted and checked for errors together. As a simple example of this approach, we describe an all optical processor for error detection and correction and then, provide an experimental demonstration of this fault tolerant reversible system, in emerging nanotechnology.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study is to evaluate lighting conditions and speleologists’ visual performance using optical filters when exposed to the lighting conditions of cave environments. A crosssectional study was conducted. Twenty-three speleologists were submitted to an evaluation of visual function in a clinical lab. An examination of visual acuity, contrast sensitivity, stereoacuity and flashlight illuminance levels was also performed in 16 of the 23 speleologists at two caves deprived of natural lightning. Two organic filters (450 nm and 550 nm) were used to compare visual function with and without filters. The mean age of the speleologists was 40.65 (± 10.93) years. We detected 26.1% participants with visual impairment of which refractive error (17.4%) was the major cause. In the cave environment the majority of the speleologists used a head flashlight with a mean illuminance of 451.0 ± 305.7 lux. Binocular visual acuity (BVA) was -0.05 ± 0.15 LogMAR (20/18). BVA for distance without filter was not statistically different from BVA with 550 nm or 450 nm filters (p = 0.093). Significant improved contrast sensitivity was observed with 450 nm filters for 6 cpd (p = 0.034) and 18 cpd (p = 0.026) spatial frequencies. There were no signs and symptoms of visual pathologies related to cave exposure. Illuminance levels were adequate to the majority of the activities performed. The enhancement in contrast sensitivity with filters could potentially improve tasks related with the activities performed in the cave.