47 resultados para Multidimensional projection
Resumo:
Dissertação apresentada à Escola Superior de Comunicação Social como parte dos requisitos para obtenção de grau de mestre em Publicidade e Marketing.
Resumo:
Medical imaging is a powerful diagnostic tool. Consequently, the number of medical images taken has increased vastly over the past few decades. The most common medical imaging techniques use X-radiation as the primary investigative tool. The main limitation of using X-radiation is associated with the risk of developing cancers. Alongside this, technology has advanced and more centres now use CT scanners; these can incur significant radiation burdens compared with traditional X-ray imaging systems. The net effect is that the population radiation burden is rising steadily. Risk arising from X-radiation for diagnostic medical purposes needs minimising and one way to achieve this is through reducing radiation dose whilst optimising image quality. All ages are affected by risk from X-radiation however the increasing population age highlights the elderly as a new group that may require consideration. Of greatest concern are paediatric patients: firstly they are more sensitive to radiation; secondly their younger age means that the potential detriment to this group is greater. Containment of radiation exposure falls to a number of professionals within medical fields, from those who request imaging to those who produce the image. These staff are supported in their radiation protection role by engineers, physicists and technicians. It is important to realise that radiation protection is currently a major European focus of interest and minimum competence levels in radiation protection for radiographers have been defined through the integrated activities of the EU consortium called MEDRAPET. The outcomes of this project have been used by the European Federation of Radiographer Societies to describe the European Qualifications Framework levels for radiographers in radiation protection. Though variations exist between European countries radiographers and nuclear medicine technologists are normally the professional groups who are responsible for exposing screening populations and patients to X-radiation. As part of their training they learn fundamental principles of radiation protection and theoretical and practical approaches to dose minimisation. However dose minimisation is complex – it is not simply about reducing X-radiation without taking into account major contextual factors. These factors relate to the real world of clinical imaging and include the need to measure clinical image quality and lesion visibility when applying X-radiation dose reduction strategies. This requires the use of validated psychological and physics techniques to measure clinical image quality and lesion perceptibility.
Resumo:
Introduction: The purpose of this review is to gather and analyse current research publications to evaluate Sinogram-Affirmed Iterative Reconstruction (SAFIRE). The aim of this review is to investigate whether this algorithm is capable of reducing the dose delivered during CT imaging while maintaining image quality. Recent research shows that children have a greater risk per unit dose due to increased radiosensitivity and longer life expectancies, which means it is particularly important to reduce the radiation dose received by children. Discussion: Recent publications suggest that SAFIRE is capable of reducing image noise in CT images, thereby enabling the potential to reduce dose. Some publications suggest a decrease in dose, by up to 64% compared to filtered back projection, can be accomplished without a change in image quality. However, literature suggests that using a higher SAFIRE strength may alter the image texture, creating an overly ‘smoothed’ image that lacks contrast. Some literature reports SAFIRE gives decreased low contrast detectability as well as spatial resolution. Publications tend to agree that SAFIRE strength three is optimal for an acceptable level of visual image quality, but more research is required. The importance of creating a balance between dose reduction and image quality is stressed. In this literature review most of the publications were completed using adults or phantoms, and a distinct lack of literature for paediatric patients is noted. Conclusion: It is necessary to find an optimal way to balance dose reduction and image quality. More research relating to SAFIRE and paediatric patients is required to fully investigate dose reduction potential in this population, for a range of different SAFIRE strengths.
Resumo:
Myocardial perfusion gated-single photon emission computed tomography (gated-SPECT) imaging is used for the combined evaluation of myocardial perfusion and left ventricular (LV) function. The aim of this study is to analyze the influence of counts/pixel and concomitantly the total counts in the myocardium for the calculation of myocardial functional parameters. Material and methods: Gated-SPECT studies were performed using a Monte Carlo GATE simulation package and the NCAT phantom. The simulations of these studies use the radiopharmaceutical 99mTc-labeled tracers (250, 350, 450 and 680MBq) for standard patient types, effectively corresponding to the following activities of myocardium: 3, 4.2, 5.4-8.2MBq. All studies were simulated using 15 and 30s/projection. The simulated data were reconstructed and processed by quantitative-gated-SPECT software, and the analysis of functional parameters in gated-SPECT images was done by using Bland-Altman test and Mann-Whitney-Wilcoxon test. Results: In studies simulated using different times (15 and 30s/projection), it was noted that for the activities for full body: 250 and 350MBq, there were statistically significant differences in parameters Motility and Thickness. For the left ventricular ejection fraction (LVEF), end-systolic volume (ESV) it was only for 250MBq, and 350MBq in the end-diastolic volume (EDV), while the simulated studies with 450 and 680MBq showed no statistically significant differences for global functional parameters: LVEF, EDV and ESV. Conclusion: The number of counts/pixel and, concomitantly, the total counts per simulation do not significantly interfere with the determination of gated-SPECT functional parameters, when using the administered average activity of 450MBq, corresponding to the 5.4MBq of the myocardium, for standard patient types.
Resumo:
Purpose: Evaluate the type of breast compression (gradual or no gradual) that provides less discomfort to the patient. Methods and Materials: The standard projections were simulated [craniocaudal/(CC) and mediolateral-oblique/(MLO)] with the two breast compressions in 90 volunteers women aged between 19 and 86. The women were organised in groups according to the breast density. The intensity of discomfort was evaluated using the scale that have represented several faces (0-10) proposed by Wong Baker in the end of each simulation. It was also applied an interview using focus group to debate the score that were attributed during pain evaluation and to identify the criteria that were considered to do the classification. Results: The women aged between 19-29y (with higher breast density) classified the pain during no gradual compression as 4 and the gradual compression as 2 for both projections. The MLO projection was considered the most uncomfortable. During the focus group interview applied to this group was highlighted that compression did not promoted pain but discomfort. They considered that the high expectations of pain did not correspond to the discomfort that they felt. Similar results were identified for the older women (30-50y; > 50y). Conclusion: The radiographers should considerer the technique for breast compression. The gradual compression was considered for the majority of the women as the most comfortable regardless of breast density. The MLO projection was considered as uncomfortable due to the positioning (axila and inclusion of pectoral muscle) and due to the higher breast compression compared to the CC projection.
Resumo:
Finding the structure of a confined liquid crystal is a difficult task since both the density and order parameter profiles are nonuniform. Starting from a microscopic model and density-functional theory, one has to either (i) solve a nonlinear, integral Euler-Lagrange equation, or (ii) perform a direct multidimensional free energy minimization. The traditional implementations of both approaches are computationally expensive and plagued with convergence problems. Here, as an alternative, we introduce an unsupervised variant of the multilayer perceptron (MLP) artificial neural network for minimizing the free energy of a fluid of hard nonspherical particles confined between planar substrates of variable penetrability. We then test our algorithm by comparing its results for the structure (density-orientation profiles) and equilibrium free energy with those obtained by standard iterative solution of the Euler-Lagrange equations and with Monte Carlo simulation results. Very good agreement is found and the MLP method proves competitively fast, flexible, and refinable. Furthermore, it can be readily generalized to the richer experimental patterned-substrate geometries that are now experimentally realizable but very problematic to conventional theoretical treatments.
Resumo:
Objectives: Children have a greater risk from radiation, per unit dose, due to increased radiosensitivity and longer life expectancies. It is of paramount importance to reduce the radiation dose received by children. This research concerns chest CT examinations on paediatric patients. The purpose of this study was to compare the image quality and the dose received from imaging with images reconstructed with filtered back projection (FBP) and five strengths of Sinogram-Affirmed Iterative Reconstruction (SAFIRE). Methods: Using a multi-slice CT scanner, six series of images were taken of a paediatric phantom. Two kVp values (80 and 110), 3 mAs values (25, 50 and 100) and 2 slice thicknesses (1 mm and 3 mm) were used. All images were reconstructed with FBP and five strengths of SAFIRE. Ten observers evaluated visual image quality. Dose was measured using CT-Expo. Results: FBP required a higher dose than all SAFIRE strengths to obtain the same image quality for sharpness and noise. For sharpness and contrast image quality ratings of 4, FBP required doses of 6.4 and 6.8 mSv respectively. SAFIRE 5 required doses of 3.4 and 4.3 mSv respectively. Clinical acceptance rate was improved by the higher voltage (110 kV) for all images in comparison to 80 kV, which required a higher dose for acceptable image quality. 3 mm images were typically better quality than 1 mm images. Conclusion: SAFIRE 5 was optimal for dose reduction and image quality.
Resumo:
Com este artigo, pretende-se divulgar parte de um estudo de doutoramento de natureza qualitativa sobre a avaliação para as aprendizagens de alunos com Necessidades Educativas Especiais (NEE). Após um breve enquadramento teórico apresentamos os resultados e as conclusões relativas ao pensamento de vários atores educativos no que respeita ao conceito de avaliação quando estão em causa alunos com NEE. Posteriormente confrontam-se esses resultados com o que é expresso em documentos do Agrupamento de Escolas onde foi realizado o estudo e com perspetivas teóricas atuais. Conclui-se que se atribui ao conceito de avaliação natureza diversa. Significados que oscilam entre abordagens essencialmente classificativas e de medida e abordagens que reconhecem a avaliação enquanto processo em que se desenvolvem interações complexas, eminentemente relacionais e comsignificados multidimensionais. Também emerge alguma tensão entre um discurso do apropriado e narrativas do que na realidade é concretizado.
Resumo:
Brain dopamine transporters imaging by Single Photon Emission Tomography (SPECT) with 123I-FP-CIT has become an important tool in the diagnosis and evaluation of parkinsonian syndromes, since this radiopharmaceutical exhibits high affinity for membrane transporters responsible for cellular reabsorption of dopamine on the striatum. However, Ordered Subset Expectation Maximization (OSEM) is the method recommended in the literature for imaging reconstruction. Filtered Back Projection (FBP) is still used due to its fast processing, even if it presents some disadvantages. The aim of this work is to investigate the influence of reconstruction parameters for FBP in semiquantification of Brain Studies with 123I-FPCIT compared with those obtained with OSEM recommended reconstruction.
Resumo:
Porquê este projeto? Conhecimentos, aptidões, competências; desenvolvimento de competências (instrumentais, interpessoais, sistémicas); contributo para uma concepção de carácter multidimensional do estudante, preparando-o para apreender a importância da investigação, preparando-o para uma profissão de saúde; as novas soluções tecnológicas, a par da inovação e a mudança nos cuidados de saúde e dos processos de trabalho, constituem hoje os desafios do presente e do futuro para os profissionais de saúde [o desenvolvimento da tecnologia e da informática, a educação e a prática baseada na evidência (investigação), as mudanças nos processos de trabalho, o trabalho em equipa, a dimensão internacional]; a investigação e o seu impacto na profissão (desenvolvimento de conhecimentos próprios das profissões, autonomia, impacto positivo nas práticas profissionais, benefício do doente); a investigação auxilia no processo de definição dos parâmetros de uma profissão (nenhuma profissão terá um desenvolvimento sustentado sem o contributo da investigação; é através da investigação que se constitui um domínio de conhecimentos baseados na evidência que permitam as boas práticas); apostar num projeto associado à investigação, com uma base científica que contribua para uma melhor educação e prática profissional visando assegurar a credibilidade da profissão; aprendizagem centrada no estudante; adopção de metodologias de ensino que promovam a autonomia, o raciocínio, a capacidade crítica e a resolução de problemas.
Resumo:
A OMS define o envelhecimento ativo como o processo de otimizar as oportunidades de saúde, de participação na sociedade e de segurança a fim de melhorar a qualidade de vida à medida que as pessoas vão envelhecendo. O envelhecimento ativo permite que as pessoas realizem o seu potencial, nas várias vertentes da sua vida. A doença crónica é um dos fatores que fragilizam este processo nesse sentido, a promoção do envelhecimento ativo exige uma abordagem multidimensional e multidisciplinar que permita aos individuo idoso, um envelhecimento com uma maior qualidade de vida. Objetivo do estudo: caracterizar e avaliar aspetos da saúde, no envelhecimento da população idosa do concelho de Loures.
Resumo:
A imagem de transportadores cerebrais da dopamina com recurso à tomografia por emissão de fotão único com 123I-FP-CIT tornou-se uma ferramenta importante no diagnóstico e avaliação de síndromes parkinsonianos. Embora o algoritmo de reconstrução de imagem Ordered Subset Expectation Maximization (OSEM) seja o método mais recomendado na literatura para reconstrução da imagem, o Filtered Back Projection (FBP) é ainda usado devido à sua rapidez. O objetivo deste trabalho é investigar a influência dos parâmetros de reconstrução para FBP na semiquantificação em estudos cerebrais com 123I-FPCIT em comparação com os obtidos com a reconstrução recomendada por OSEM.
Resumo:
Tese para a obtenção do grau de Doutor em Economia, especialidade de Economia da Empresa
Resumo:
Dissertação apresentada à Escola Superior de Comunicação Social como parte dos requisitos para obtenção de grau de mestre em Audiovisual e Multimédia.
Resumo:
Relatório de Estágio submetido à Escola Superior de Teatro e Cinema para cumprimento dos requisitos necessários à obtenção do grau de Mestre em Teatro - especialização em Produção.