45 resultados para Contextual visual localization
Resumo:
Speleologist’s perform their activity in demanding visual conditions of very low luminance - many visual tasks involve resolution of detail under conditions of low contrast. Work related conditions in a cave as exposure to heat, chemicals, dust and poor lighting conditions could influence the integrity of the visual system and predispose the eye to diseases that eventually affect vision. Poor lighting conditions cause a variety of symptoms of visual discomfort and may increase the risk of accidents. Good visual acuity is crucial for several and has an important role for safety purposes. The aim of this study was to evaluate lighting conditions and optical filters effects on visual performance in speleologists exposed to cave environments.
Resumo:
Many studies have demonstrated the relationship between the alpha activity and the central visual ability, in which the visual ability is usually assessed through static stimuli. Besides static circumstance, however in the real environment there are often dynamic changes and the peripheral visual ability in a dynamic environment (i.e., dynamic peripheral visual ability) is important for all people. So far, no work has reported whether there is a relationship between the dynamic peripheral visual ability and the alpha activity. Thus, the objective of this study was to investigate their relationship. Sixty-two soccer players performed a newly designed peripheral vision task in which the visual stimuli were dynamic, while their EEG signals were recorded from Cz, O1, and O2 locations. The relationship between the dynamic peripheral visual performance and the alpha activity was examined by the percentage-bend correlation test. The results indicated no significant correlation between the dynamic peripheral visual performance and the alpha amplitudes in the eyes-open and eyes-closed resting condition. However, it was not the case for the alpha activity during the peripheral vision task: the dynamic peripheral visual performance showed significant positive inter-individual correlations with the amplitudes in the alpha band (8-12 Hz) and the individual alpha band (IAB) during the peripheral vision task. A potential application of this finding is to improve the dynamic peripheral visual performance by up-regulating alpha activity using neuromodulation techniques.
Resumo:
Aims of study: 1) Describe the importance of human visual system on lesion detection in medical imaging perception research; 2) Discuss the relevance of research in medical imaging addressing visual function analysis; 3) Identify visual function tests which could be conducted on observers prior to participation in medical imaging perception research.
Resumo:
A visão possui um elevado significado no desenvolvimento infantil. A deficiência visual acarreta um impacto negativo na criança no que respeita à sua educação e integração social. No universo populacional existem globalmente cerca de 1 milhão e 500 mil crianças cegas e 19 milhões com algum tipo de deficiência visual, abrangendo a faixa etária dos 0 aos 14 anos. De acordo com a Direcção Geral de Saúde Portuguesa, estima-se a prevalência de 1,00 a 2,5% de ambliopia entre as crianças, em Portugal, constituindo uma das 3 principais causas de hipovisão monocular. Por isso, a prevenção primária e detecção precoces são cada vez mais importantes na redução das taxas de incidência de patologias oculares. A redução dos casos evitáveis de deficiência visual nas crianças alentejanas, é um objectivo importante da Unidade Local de Saúde do Baixo Alentejo (ULSBA), promovendo acções de rastreio visual para o diagnóstico, a referenciação e o encaminhamento precoces. O Alentejo, região do centro-sul de Portugal, é a maior região de Portugal, com 31.551 km2 de área e 757.190 habitantes. Moura é um concelho do Baixo Alentejo, com 958,46 km2 e 15.167 habitantes e 15,83% são crianças dos 0 aos 14 anos. Objectivos do estudo: detectar factores ambliogénicos e caracterizar o estado visual das crianças nascidas em 2009 e que frequentam os jardins-de-infância (JI) públicos, do concelho de Moura, num total de 9.
Resumo:
In this paper a new PCA-based positioning sensor and localization system for mobile robots to operate in unstructured environments (e. g. industry, services, domestic ...) is proposed and experimentally validated. The inexpensive positioning system resorts to principal component analysis (PCA) of images acquired by a video camera installed onboard, looking upwards to the ceiling. This solution has the advantage of avoiding the need of selecting and extracting features. The principal components of the acquired images are compared with previously registered images, stored in a reduced onboard image database, and the position measured is fused with odometry data. The optimal estimates of position and slippage are provided by Kalman filters, with global stable error dynamics. The experimental validation reported in this work focuses on the results of a set of experiments carried out in a real environment, where the robot travels along a lawn-mower trajectory. A small position error estimate with bounded co-variance was always observed, for arbitrarily long experiments, and slippage was estimated accurately in real time.
Resumo:
In the field of appearance-based robot localization, the mainstream approach uses a quantized representation of local image features. An alternative strategy is the exploitation of raw feature descriptors, thus avoiding approximations due to quantization. In this work, the quantized and non-quantized representations are compared with respect to their discriminativity, in the context of the robot global localization problem. Having demonstrated the advantages of the non-quantized representation, the paper proposes mechanisms to reduce the computational burden this approach would carry, when applied in its simplest form. This reduction is achieved through a hierarchical strategy which gradually discards candidate locations and by exploring two simplifying assumptions about the training data. The potential of the non-quantized representation is exploited by resorting to the entropy-discriminativity relation. The idea behind this approach is that the non-quantized representation facilitates the assessment of the distinctiveness of features, through the entropy measure. Building on this finding, the robustness of the localization system is enhanced by modulating the importance of features according to the entropy measure. Experimental results support the effectiveness of this approach, as well as the validity of the proposed computation reduction methods.
Resumo:
A pentagonal patch-excited sectorized antenna (SA) suitable for 2.4-2.5 GHz localization systems was studied and developed. The integration of six patch-excited structures converges into a sectorized antenna called Hive5 that provides gain improvement compared to a patch antenna, maximum variation of 3 dB beam width over the radiation pattern and circular polarization (CP). This antenna is presented and analyzed taking into account the tap length and the flare angle. The proposed antenna in combination with a RF-Switch provides a cost effective solution for localization based on Wireless Sensor Networks (WSN) and will be used for implementing angle of arrival (AoA) techniques combined with RF fingerprinting techniques.
Resumo:
Background - Medical image perception research relies on visual data to study the diagnostic relationship between observers and medical images. A consistent method to assess visual function for participants in medical imaging research has not been developed and represents a significant gap in existing research. Methods - Three visual assessment factors appropriate to observer studies were identified: visual acuity, contrast sensitivity, and stereopsis. A test was designed for each, and 30 radiography observers (mean age 31.6 years) participated in each test. Results - Mean binocular visual acuity for distance was 20/14 for all observers. The difference between observers who did and did not use corrective lenses was not statistically significant (P = .12). All subjects had a normal value for near visual acuity and stereoacuity. Contrast sensitivity was better than population norms. Conclusion - All observers had normal visual function and could participate in medical imaging visual analysis studies. Protocols of evaluation and populations norms are provided. Further studies are necessary to understand fully the relationship between visual performance on tests and diagnostic accuracy in practice.
Resumo:
O processo de envelhecimento fisiológico é marcado por um decréscimo das capacidades motoras, redução da força, flexibilidade, função visual, entre outros. Adicionalmente, alterações patológicas do sistema visual com impacto na função visual podem alterar o equilíbrio e aumentar o risco de quedas. Os indivíduos com idade ≥ 50 anos representam entre 65% a 82% dos casos de baixa visão e cegueira. O risco de quedas é superior em mulheres com acuidade visual ≤0,5. Objectivo do estudo: avaliar a relação entre a função visual e o risco de quedas.
Resumo:
A prevenção primária/detecção precoce são cada vez mais importantes na redução das taxas de incidência de patologia ocular. De acordo com a DGS, estima-se a prevalência de ambliopia de 1,00 a 2,5% de ambliopia entre as crianças, em Portugal, constituindo uma das 3 principais causas de hipovisão monocular. O Ortoptista desenvolve um papel activo nos Cuidados de Saúde Primários, através de rastreios escolares, contribuindo para o diagnóstico precoce. Objectivo do estudo - Detectar factores ambliogénicos e caracterizar o estado visual das crianças nascidas em 2009 e que frequentam o total dos jardins-de-infância do concelho de Moura.
Resumo:
Introdução – Na correção de miopias elevadas, a cirurgia por implante de lente intraocular fáquica tem tido progressivamente uma maior adesão em relação à cirurgia por laser. Compara-se a acuidade visual (AV) antes e após a cirurgia implanto-refrativa, verificando-se a efetividade deste método no incremento da visão em miopias elevadas. Metodologia – Foram analisados, retrospetivamente, 70 olhos de 41 pacientes, com miopia elevada, entre os 20 e 50 anos, submetidos a cirurgia implanto-refrativa entre 2009 e 2012. Resultados – Um dia após cirurgia, 42,86% da amostra melhorou a AV, 34,29% manteve e 22,85% diminuiu. Após 30 dias observou-se um aumento generalizado da quantidade de visão, sendo que: 64,29% atingiu os 10/10 de AV, 24,29% alcançou entre 9/10-7/10 e 11,42% entre 6/10-4/10. Conclusão – Comprovou-se a efetividade desta técnica cirúrgica, verificando-se o aumento da AV em 52,86% da amostra.
Resumo:
Introdução – A cintigrafia de perfusão do miocárdio (CPM) desempenha um importante papel no diagnóstico, avaliação e seguimento de pacientes com doença arterial coronária, sendo o seu processamento realizado maioritariamente de forma semiautomática. Uma vez que o desempenho dos técnicos de medicina nuclear (TMN) pode ser afetado por fatores individuais e ambientais, diferentes profissionais que processem os mesmos dados poderão obter diferentes estimativas dos parâmetros quantitativos (PQ). Objetivo – Avaliar a influência da experiência profissional e da função visual no processamento semiautomático da CPM. Analisar a variabilidade intra e interoperador na determinação dos PQ funcionais e de perfusão. Metodologia – Selecionou-se uma amostra de 20 TMN divididos em dois grupos, de acordo com a sua experiência no software Quantitative Gated SPECTTM: Grupo A (GA) – TMN ≥600h de experiência e Grupo B (GB) – TMN sem experiência. Submeteram-se os TMN a uma avaliação ortóptica e ao processamento de 21 CPM, cinco vezes, não consecutivas. Considerou-se uma visão alterada quando pelo menos um parâmetro da função visual se encontrava anormal. Para avaliar a repetibilidade e a reprodutibilidade recorreu-se à determinação dos coeficientes de variação, %. Na comparação dos PQ entre operadores, e para a análise do desempenho entre o GA e GB, aplicou-se o Teste de Friedman e de Wilcoxon, respetivamente, considerando o processamento das mesmas CPM. Para a comparação de TMN com visão normal e alterada na determinação dos PQ utilizou-se o Teste Mann-Whitney e para avaliar a influência da visão para cada PQ recorreu-se ao coeficiente de associação ETA. Diferenças estatisticamente significativas foram assumidas ao nível de significância de 5%. Resultados e Discussão – Verificou-se uma reduzida variabilidade intra (<6,59%) e inter (<5,07%) operador. O GB demonstrou ser o mais discrepante na determinação dos PQ, sendo a parede septal (PS) o único PQ que apresentou diferenças estatisticamente significativas (zw=-2,051, p=0,040), em detrimento do GA. No que se refere à influência da função visual foram detetadas diferenças estatisticamente significativas apenas na fração de ejeção do ventrículo esquerdo (FEVE) (U=11,5, p=0,012) entre TMN com visão normal e alterada, contribuindo a visão em 33,99% para a sua variação. Denotaram-se mais diferenças nos PQ obtidos em TMN que apresentam uma maior incidência de sintomatologia ocular e uma visão binocular diminuída. A FEVE demonstrou ser o parâmetro mais consistente entre operadores (1,86%). Conclusão – A CPM apresenta-se como uma técnica repetível e reprodutível, independente do operador. Verificou-se influência da experiência profissional e da função visual no processamento semiautomático da CPM, nos PQ PS e FEVE, respetivamente.
Resumo:
The aim of this study is to evaluate lighting conditions and speleologists’ visual performance using optical filters when exposed to the lighting conditions of cave environments. A crosssectional study was conducted. Twenty-three speleologists were submitted to an evaluation of visual function in a clinical lab. An examination of visual acuity, contrast sensitivity, stereoacuity and flashlight illuminance levels was also performed in 16 of the 23 speleologists at two caves deprived of natural lightning. Two organic filters (450 nm and 550 nm) were used to compare visual function with and without filters. The mean age of the speleologists was 40.65 (± 10.93) years. We detected 26.1% participants with visual impairment of which refractive error (17.4%) was the major cause. In the cave environment the majority of the speleologists used a head flashlight with a mean illuminance of 451.0 ± 305.7 lux. Binocular visual acuity (BVA) was -0.05 ± 0.15 LogMAR (20/18). BVA for distance without filter was not statistically different from BVA with 550 nm or 450 nm filters (p = 0.093). Significant improved contrast sensitivity was observed with 450 nm filters for 6 cpd (p = 0.034) and 18 cpd (p = 0.026) spatial frequencies. There were no signs and symptoms of visual pathologies related to cave exposure. Illuminance levels were adequate to the majority of the activities performed. The enhancement in contrast sensitivity with filters could potentially improve tasks related with the activities performed in the cave.
Resumo:
In this paper a new method for self-localization of mobile robots, based on a PCA positioning sensor to operate in unstructured environments, is proposed and experimentally validated. The proposed PCA extension is able to perform the eigenvectors computation from a set of signals corrupted by missing data. The sensor package considered in this work contains a 2D depth sensor pointed upwards to the ceiling, providing depth images with missing data. The positioning sensor obtained is then integrated in a Linear Parameter Varying mobile robot model to obtain a self-localization system, based on linear Kalman filters, with globally stable position error estimates. A study consisting in adding synthetic random corrupted data to the captured depth images revealed that this extended PCA technique is able to reconstruct the signals, with improved accuracy. The self-localization system obtained is assessed in unstructured environments and the methodologies are validated even in the case of varying illumination conditions.
Resumo:
Dissertação apresentada à Escola Superior de Comunicação Social como parte dos requisitos para obtenção de grau de mestre em Publicidade e Marketing.