52 resultados para microonde, imaging, mammella, cancro, diagnosi


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Claustrophobia causes a huge discomfort to those who need to perform Magnetic Resonance examinations mainly due to the physical design of most equipment. This study aimed to maximize the success rate of Magnetic Resonance Imaging (MRI) clinical studies in claustrophobic patients by the identification of facilitative strategies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mestrado em Radiações Aplicadas às Tecnologias da Saúde.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mestrado em Radiações Aplicadas às Tecnologias da Saúde. Área de especialização: Terapia com Radiações.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Susceptibility-weighted imaging (SWI) is a relatively new contrast in MR imaging. Previous studies have found an effect of caffeine in the contrast generated by SWI images. The present study investigates the effect of caffeine on contrast-to-noise ratio (CNR) in SWI.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O cancro colo-rectal é o terceiro tipo de cancro mais comum em ambos os sexos. Os factores ambientais, o sedentarismo, a obesidade, o tabagismo, o álcool, uma dieta rica em carne vermelha e pobre em fibras, desempenham um forte papel na etiologia do cancro do recto. Nas últimas duas décadas a adopção generalizada da excisão mesoretal total (TME) e uso da quimio-radioterapia (QRT) pré-operatória, aumentou as taxas de controlo local, sobrevida global e livre de doença. Quando comparada com a QRT pós-operatória, a QRT pré-operatória demonstra ser mais eficaz, uma vez que possibilita um maior controlo local, como também uma menor toxicidade, rnomeadamente do intestino delgado. Contudo, verifica-se efeitos colaterais adversos, que influenciam negativamente a qualidade de vida (QoL) dos doentes, sendo os mais comuns a incontinência urinária e fecal, e a disfunção sexual. Com este estudo pretende-se avaliar a QoL dos doentes com cancro do recto localmente avançado (T3-T4), em 3 momentos de avaliação, isto é, antes, durante e no final do tratamento. Pretende-se ainda determinar se a idade influencia a QoL dos doentes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

RESUMO: Introdução – A evolução tecnológica permitiu uma deteção precoce do cancro e, consequentemente, uma abordagem terapêutica mais eficaz e efetiva, resultando no aumento da sobrevida dos doentes. Assim, pretende-se avaliar a influência da radioterapia na qualidade de vida dos doentes com cancro da mama. Metodologia – 47 participantes que efetuaram radioterapia no Centro Hospitalar Barreiro-Montijo preencheram os dois questionários, o EORTC QLQ-C30 e o QLQ-BR23, antes de iniciar radioterapia e no último dia do tratamento. Os resultados foram analisados através do programa informático SPSS, versão 19.0. Resultados – Observou-se um ligeiro decréscimo na qualidade da saúde global no segundo momento de avaliação. Verificou-se uma diminuição nas escalas sintomática e funcional no segundo momento de avaliação. Em relação ao questionário QLQ-BR23, na escala sintomática, observou-se uma diminuição nos efeitos secundários resultantes da radioterapia no último momento de avaliação. Discussão dos Resultados – Os resultados obtidos no questionário QLQ-C30 revelam que a avaliação global da saúde dos doentes não é influenciada pelo tratamento de radioterapia. Em relação ao questionário QLQ-BR23, os sintomas relacionados com a mama e o braço tiveram um aumento ligeiramente significativo no segundo momento de avaliação, sendo estes associados à radioterapia. De acordo com os resultados obtidos, a radioterapia não influencia a qualidade de vida em doentes com cancro da mama.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

De acordo com o estudo de Gatta e col, em Janeiro de 2003, 11,6 milhões de europeus apresentaram história clínica de cancro. Destes, uma em cada 73 mulheres tinham história de cancro da mama enquanto que um em cada 160 homens apresentaram história de cancro da próstata. A prevalência em 2003 conduziu a valores estimados de - 13 milhões de europeus afetados por cancro em 2010. O cancro da mama é o tipo de cancro que mais frequentemente é diagnosticado e a segunda causa de morte por cancro nas mulheres a nível mundial e também em Portugal (Plano Nacional de Prevenção e Controlo das Doenças Oncológicas 2007-2010. De acordo com o INE, 12,4/100.000 habitantes das mortes com menos de 65 anos deveram-se a cancro da mama feminino. As opções de tratamento para o cancro podem incluir cirurgia, radioterapia, hormonoterapia, quimioterapia ou imunoterapia, as quais poderão apresentar efeitos colaterais suscetíveis de influenciar a participação no exercício e a resposta ao mesmo. Independentemente da intervenção terapêutica no cancro, a fadiga é um efeito colateral comum. Um cancro é considerado como curado quando as remissões são permanentes ou quando não existe recorrência há mais de 5 anos. Uma das razões frequentemente subestimada como causa de fadiga é a perda de condição física como resultado do acamamento e do incentivo por parte de familiares e/ou prestadores de cuidados de saúde a um maior descanso quando o doente refere fadiga. Esta situação pode limitar ainda mais as atividades da vida diária, conduzindo a um maior descondicionamento e intolerância ao exercício, cujas consequências são mais dramáticas a nível do sistema cardiorrespiratório e serem por si só responsáveis pela perda de cerca de 30 por cento da capacidade funcional do doente. De acordo com estudos efetuados em portadores de cancro da mama, a uma capacidade aeróbia abaixo dos 8 MET’s associa-se um aumento de mortalidade 3 vezes mais elevado quando comparado com mulheres com cancro da mama com capacidade aeróbia superior a 8 MET’s.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We present new Rayleigh-wave dispersion maps of the western Iberian Peninsula for periods between 8 and 30 s, obtained from correlations of seismic ambient noise, following the recent increase in seismic broadband network density in Portugal and Spain. Group velocities have been computed for each station pair using the empirical Green's functions generated by cross-correlating one-day-length seismic ambient-noise records. The resulting high-path density allows us to obtain lateral variations of the group velocities as a function of period in cells of 0.5 degrees x 0.5 degrees with an unprecedented resolution. As a result we were able to address some of the unknowns regarding the lithospheric structure beneath SW Iberia. The dispersion maps allow the imaging of the major structural units, namely the Iberian Massif, and the Lusitanian and Algarve Meso-Cenozoic basins. The Cadiz Gulf/Gibraltar Strait area corresponds to a strong low-velocity anomaly, which can be followed to the largest period inverted, although slightly shifted to the east at longer periods. Within the Iberian Massif, second-order perturbations in the group velocities are consistent with the transitions between tectonic units composing the massif. (C) 2013 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The formation of amyloid structures is a neuropathological feature that characterizes several neurodegenerative disorders, such as Alzheimer´s and Parkinson´s disease. Up to now, the definitive diagnosis of these diseases can only be accomplished by immunostaining of post mortem brain tissues with dyes such Thioflavin T and congo red. Aiming at early in vivo diagnosis of Alzheimer´s disease (AD), several amyloid-avid radioprobes have been developed for b-amyloid imaging by positron emission tomography (PET) and single-photon emission computed tomography (SPECT). The aim of this paper is to present a perspective of the available amyloid imaging agents, special those that have been selected for clinical trials and are at the different stages of the US Food and Drugs Administration (FDA) approval.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose - This study aims to investigate the influence of tube potential (kVp) variation in relation to perceptual image quality and effective dose (E) for pelvis using automatic exposure control (AEC) and non-AEC in a Computed Radiography (CR) system. Methods and materials - To determine the effects of using AEC and non-AEC by applying the 10 kVp rule in two experiments using an anthropomorphic pelvis phantom. Images were acquired using 10 kVp increments (60–120 kVp) for both experiments. The first experiment, based on seven AEC combinations, produced 49 images. The mean mAs from each kVp increment were used as a baseline for the second experiment producing 35 images. A total of 84 images were produced and a panel of 5 experienced observers participated for the image scoring using the two alternative forced choice (2AFC) visual grading software. PCXMC software was used to estimate E. Results - A decrease in perceptual image quality as the kVp increases was observed both in non-AEC and AEC experiments, however no significant statistical differences (p > 0.05) were found. Image quality scores from all observers at 10 kVp increments for all mAs values using non-AEC mode demonstrates a better score up to 90 kVp. E results show a statistically significant decrease (p = 0.000) on the 75th quartile from 0.37 mSv at 60 kVp to 0.13 mSv at 120 kVp when applying the 10 kVp rule in non-AEC mode. Conclusion - Using the 10 kVp rule, no significant reduction in perceptual image quality is observed when increasing kVp whilst a marked and significant E reduction is observed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Os sistemas Computer-Aided Diagnosis (CAD) auxiliam a deteção e diferenciação de lesões benignas e malignas, aumentando a performance no diagnóstico do cancro da mama. As lesões da mama estão fortemente correlacionadas com a forma do contorno: lesões benignas apresentam contornos regulares, enquanto as lesões malignas tendem a apresentar contornos irregulares. Desta forma, a utilização de medidas quantitativas, como a dimensão fractal (DF), pode ajudar na caracterização dos contornos regulares ou irregulares de uma lesão. O principal objetivo deste estudo é verificar se a utilização concomitante de 2 (ou mais) medidas de DF – uma tradicionalmente utilizada, a qual foi designada por “DF de contorno”; outra proposta por nós, designada por “DF de área” – e ainda 3 medidas obtidas a partir destas, por operações de dilatação/erosão e por normalização de uma das medidas anteriores, melhoram a capacidade de caracterização de acordo com a escala BIRADS (Breast Imaging Reporting and Data System) e o tipo de lesão. As medidas de DF (DF contorno e DF área) foram calculadas através da aplicação do método box-counting, diretamente em imagens de lesões segmentadas e após a aplicação de um algoritmo de dilatação/erosão. A última medida baseia-se na diferença normalizada entre as duas medidas DF de área antes e após a aplicação do algoritmo de dilatação/erosão. Os resultados demonstram que a medida DF de contorno é uma ferramenta útil na diferenciação de lesões, de acordo com a escala BIRADS e o tipo de lesão; no entanto, em algumas situações, ocorrem alguns erros. O uso combinado desta medida com as quatro medidas propostas pode melhorar a classificação das lesões.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introdução – A ressonância magnética (RM) mamária com injeção de contraste é uma ferramenta indispensável para a caracterização de lesões mamárias. Para tal, é fulcral uma boa capacidade de saturação de gordura de forma a delimitar as lesões observadas. Este trabalho tem como objetivo analisar quantitativa e qualitativamente as técnicas de saturação de gordura em RM mamária, nomeadamente as técnicas SPAIR e Dixon. Metodologia – Utilizou-se um equipamento de RM de 1,5T com bobina específica para a mama. Aplicou-se, durante o exame, uma sequência adicional em que a técnica de saturação de gordura utilizada foi a Dixon. Posteriormente foram analisadas as imagens obtidas com as técnicas SPAIR e Dixon e colocadas regiões de interesse (ROI) na lesão, na glândula mamária, no tecido adiposo e no ar. Estes valores de sinal obtidos foram registados e calcularam-se as relações sinal-ruído (SNR), contraste-ruído (CNR) e uniformidade de saturação de gordura para as mesmas estruturas a analisar e nas distintas sequências. Resultados – Verificou-se que a técnica de supressão de gordura Dixon apresenta resultados quantitativos e qualitativos superiores à técnica SPAIR. Conclusões – Recomenda-se a utilização da técnica Dixon para saturação de gordura nas sequências de estudo dinâmico com agente de contraste, especificamente nos estudos de RM mamária.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim - A quantative primary study to determine whether increasing source to image distance (SID), with and without the use of automatic exposure control (AEC) for antero-posterior (AP) pelvis imaging, reduces dose whilst still producing an image of diagnostic quality. Methods - Using a computed radiography (CR) system, an anthropomorphic pelvic phantom was positioned for an AP examination using the table bucky. SID was initially set at 110 cm, with tube potential set at a constant 75 kVp, with two outer chambers selected and a fine focal spot of 0.6 mm. SID was then varied from 90 cm to 140 cm with two exposures made at each 5 cm interval, one using the AEC and another with a constant 16 mAs derived from the initial exposure. Effective dose (E) and entrance surface dose (ESD) were calculated for each acquisition. Seven experienced observers blindly graded image quality using a 5-point Likert scale and 2 Alternative Forced Choice software. Signal-to-Noise Ratio (SNR) was calculated for comparison. For each acquisition, femoral head diameter was also measured for magnification indication. Results - Results demonstrated that when increasing SID from 110 cm to 140 cm, both E and ESD reduced by 3.7% and 17.3% respectively when using AEC and 50.13% and 41.79% respectively, when the constant mAs was used. No significant statistical (T-test) difference (p = 0.967) between image quality was detected when increasing SID, with an intra-observer correlation of 0.77 (95% confidence level). SNR reduced slightly for both AEC (38%) and no AEC (36%) with increasing SID. Conclusion - For CR, increasing SID significantly reduces both E and ESD for AP pelvis imaging without adversely affecting image quality.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mestrado em Medicina Nuclear - Ramo de especialização: Tomografia por Emissão de Positrões