20 resultados para harmonic generation
Resumo:
Renewable energy sources (RES) have unique characteristics that grant them preference in energy and environmental policies. However, considering that the renewable resources are barely controllable and sometimes unpredictable, some challenges are faced when integrating high shares of renewable sources in power systems. In order to mitigate this problem, this paper presents a decision-making methodology regarding renewable investments. The model computes the optimal renewable generation mix from different available technologies (hydro, wind and photovoltaic) that integrates a given share of renewable sources, minimizing residual demand variability, therefore stabilizing the thermal power generation. The model also includes a spatial optimization of wind farms in order to identify the best distribution of wind capacity. This methodology is applied to the Portuguese power system.
Resumo:
The main objective of this work was to evaluate the hypothesis that the greater transfer stability leads also to less volume of fumes. Using an Ar + 25%CO2 blend as shielding gas and maintaining constant the average current, wire feed speed and welding speed, bead-on-plate welds were carried out with plain carbon steel solid wire. The welding voltage was scanned to progressively vary the transfer stability. Using two conditions of low stability and one with high stability, fume generation was evaluated by means of the AWS F1.2:2006 standard. The influence of these conditions on fume morphology and composition was also verified. A condition with greater transfer stability does not generate less fume quantity, despite the fact that this condition produces fewer spatters. Other factors such as short-circuit current, arcing time, droplet diameters and arc length are the likely governing factors, but in an interrelated way. Metal transfer stability does not influence either the composition or the size/morphology of fume particulates. (c) 2014 Elsevier B.V. All rights reserved.
Resumo:
This paper presents a coordination approach to maximize the total profit of wind power systems coordinated with concentrated solar power systems, having molten-salt thermal energy storage. Both systems are effectively handled by mixed-integer linear programming in the approach, allowing enhancement on the operational during non-insolation periods. Transmission grid constraints and technical operating constraints on both systems are modeled to enable a true management support for the integration of renewable energy sources in day-ahead electricity markets. A representative case study based on real systems is considered to demonstrate the effectiveness of the proposed approach. © IFIP International Federation for Information Processing 2015.
Resumo:
β-d-glucans from basidiomycete strains are powerful immunomodulatory agents in several clinical conditions. Therefore, their assay, purification and characterization are of great interest to understand their structure-function relationship. Hybridoma cell fusion was used to raise monoclonal antibodies (Mabs) against extracellular β-d-glucans (EBGs) from Pleurotus ostreatus. Two of the hybridoma clones (1E6-1E8-B5 and 3E8-3B4) secreting Mabs against EBGs were selected. This hybridoma cell line secreted Mabs of the IgG class which were then purified by hydroxyapatite chromatography to apparent homogeneity on native and SDS-PAGE. Mabs secreted by 1E6-1E8-B5 clone were found to recognize a common epitope on several β-d-glucans from different basidiomycete strains. This Mab exhibited high affinity constant (KA) for β-d-glucans from several mushroom strains in the range of 3.20 × 109 ± 3.32 × 103-1.51 × 1013 ± 3.58 × 107 L/mol. Moreover, they reacted to some heat-treated β-d-glucans in a different mode when compared with the native forms; these data suggest that this Mab binds to a conformational epitope on the β-d-glucan molecule. The epitope-binding studies of Mabs obtained from 1E6-1E8-B5 and 3E8-3B4 revealed that the Mabs bind to the same epitope on some β-d-glucans and to different epitopes in other antigen molecules. Therefore, these Mabs can be used to assay for β-d-glucan from basidiomycete mushrooms. © 2015 Elsevier Ltd. All rights reserved.
Resumo:
The importance of wind power energy for energy and environmental policies has been growing in past recent years. However, because of its random nature over time, the wind generation cannot be reliable dispatched and perfectly forecasted, becoming a challenge when integrating this production in power systems. In addition the wind energy has to cope with the diversity of production resulting from alternative wind power profiles located in different regions. In 2012, Portugal presented a cumulative installed capacity distributed over 223 wind farms [1]. In this work the circular data statistical methods are used to analyze and compare alternative spatial wind generation profiles. Variables indicating extreme situations are analyzed. The hour (s) of the day where the farm production attains its maximum daily production is considered. This variable was converted into circular variable, and the use of circular statistics enables to identify the daily hour distribution for different wind production profiles. This methodology was applied to a real case, considering data from the Portuguese power system regarding the year 2012 with a 15-minutes interval. Six geographical locations were considered, representing different wind generation profiles in the Portuguese system.In this work the circular data statistical methods are used to analyze and compare alternative spatial wind generation profiles. Variables indicating extreme situations are analyzed. The hour (s) of the day where the farm production attains its maximum daily production is considered. This variable was converted into circular variable, and the use of circular statistics enables to identify the daily hour distribution for different wind production profiles. This methodology was applied to a real case, considering data from the Portuguese power system regarding the year 2012 with a 15-minutes interval. Six geographical locations were considered, representing different wind generation profiles in the Portuguese system.