19 resultados para extraction procedures


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Additional apple juice extraction with pulsed electric field pretreated apple cubes towards control samples is evaluated. Monopolar and bipolar shaped pulses are compared and their effect is studied with variation of electric field, pulse width and number of pulses. Variation of electric field strength is ranged from 100 V/cm to 1300 V/cm, pulse width from 20 mu s to 300 mu s and number of pulses from 10 to 200, at frequency of 200Hz. Two pulse trains separated by 1 second are applied to all samples. Bipolar pulses showed higher apple juice yields with all studied parameters. Calculation of specific energies consumed was assessed and a threshold where higher energy inputs do not increase juice yield is found for a number of used parameters. Qualitative parameters of total soluble matter (Brix) and absorbance at 390 nm wavelength were determined for each sample and results show that no substantial differences are found for PEF pre-treated and control samples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: The samples obtained from fine needle aspiration in liquid base cytology (FNAC) are often limited by scarce cellularity compared to the amount of colloid and presence of blood. Accordingly, it was important to test alternative technical procedures so as to maximize the cellularity of each sample. Objective: To compare the morphological features and cellularity of the three procedures in the FNAC cytodiagnosis of the thyroid. Methods: A total of 31 cases were each subjected to a cell block and ThinPrep preparation as well as a routine smear. The observation and analysis was performed using an optical microscope. Cytological diagnosis of each cell block case was objectively analysed for cellularity, presence of background and cellular preservation. Each smear and ThinPrep case was analysed for the presence or absence of cells. The data was analysed with Microsoft Excel (Office 2010) and SPSS (Statistical Package of Social Science) version 15.0 for Windows. Results: Of 31 cases, only 20 had thyroid cells in the cell block and ThinPrep preparations, however, all smear cases contained thyroid cells. Some background was found in 30 Cell block cases with only 5 of these containing well preserved cells for cytodiagnosis. Conclusions: As indicated by the results, smear is the most appropriate procedure for FNAC of the thyroid.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

One of the most challenging task underlying many hyperspectral imagery applications is the linear unmixing. The key to linear unmixing is to find the set of reference substances, also called endmembers, that are representative of a given scene. This paper presents the vertex component analysis (VCA) a new method to unmix linear mixtures of hyperspectral sources. The algorithm is unsupervised and exploits a simple geometric fact: endmembers are vertices of a simplex. The algorithm complexity, measured in floating points operations, is O (n), where n is the sample size. The effectiveness of the proposed scheme is illustrated using simulated data.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Linear unmixing decomposes an hyperspectral image into a collection of re ectance spectra, called endmember signatures, and a set corresponding abundance fractions from the respective spatial coverage. This paper introduces vertex component analysis, an unsupervised algorithm to unmix linear mixtures of hyperpsectral data. VCA exploits the fact that endmembers occupy vertices of a simplex, and assumes the presence of pure pixels in data. VCA performance is illustrated using simulated and real data. VCA competes with state-of-the-art methods with much lower computational complexity.