96 resultados para environmental Health
Occupational exposure to formaldehyde: effects of years of exposure in the frequency of micronucleus
Resumo:
Formaldehyde: an important industrial compound used in the manufacture of synthetic resins and chemical compounds such as lubricants and adhesives; also applied as a disinfectant, preservative and in cosmetics productions; relevant workplace exposure to FA also occurs in anatomy, pathology and in mortuaries; classified by IARC as carcinogenic to humans (Group 1), based on sufficient evidence in humans and experimental animals; manifold in vitro studies indicated that FA can induce genotoxic effects in proliferating cultured mammalian cells. Aim of the study: to evaluate if years of exposure induced a genotoxic biomarkers increase, namely MN in lymphocytes and buccal cells, in workers occupationally exposed to FA (factory and pathology anatomy laboratory).
Resumo:
Formaldehyde is classified by IARC as carcinogenic to humans (nasopharyngeal cancer). Tobacco smoke has been epidemiologically associated to a higher risk of development of cancer, especially in the oral cavity, larynx and lungs, as these are places of direct contact with many carcinogenic tobacco’s compounds. XRCC3 is involved in homologous recombination repair of cross-links and chromosomal double-strand breaks (Thr241Met polymorphism). The aim of the study is to determine whether there is an in vivo association between genetic polymorphism of the gene XRCC3 and the frequency of genotoxicity biomarkers in subjects exposed or not to formaldehyde and with or without tobacco consumption.
Resumo:
Do ponto de vista das preocupações de saúde, os níveis de contaminação do ar interior assumem actualmente uma elevada importância quando se tem em consideração que as pessoas passam a maior parte do seu tempo no interior de edifícios. Neste contexto, o formaldeído é um dos poluentes mais preocupantes e, inclusivamente, os resultados de concentração obtidos em habitações do espaço Europeu foram considerados preocupantes devido ao facto de estarem relacionados com efeitos negativos para a saúde. O estudo exploratório desenvolvido pretendeu disponibilizar informação acerca das concentrações de formaldeído existentes em habitações domésticas portuguesas. Estudou‑se a presença de formaldeído em habitações novas e habitações domésticas com ocupação, abrangendo 6 unidades de cada um dos tipos considerados. Para a avaliação ambiental foi utilizado um equipamento de leitura direta que deteta as concentrações de formaldeído por fotoionização com uma lâmpada de 11,7 eV. A temperatura ambiente e a humidade relativa foram igualmente medidas, de acordo com o estipulado na Norma Internacional ISO 7726:1998. No caso das habitações novas foram registados valores de concentração superiores a 0,08 ppm em 3 das unidades estudadas. Por outro lado, em 4 das habitações com ocupação foram obtidos valores superiores a 0,08 ppm. O desenvolvimento deste estudo permitiu reconhecer algumas das possíveis fontes emissoras e os factores que influenciam as concentrações de formaldeído nas habitações em Portugal. ABSTRACT - Nowadays, indoor air contamination is considering an important health issue considering that people spend most of their time indoors. In this context, formaldehyde is a pollutant of major concern and, recently, concentration results obtained in European dwellings reveal high concentrations and values related with negative health effects in occupants. The present exploratory study sought to provide information about formaldehyde concentrations in Portuguese dwellings. It was studied formaldehyde presence in new dwellings and dwellings with occupation and included 6 units of each setting. For concentrations measure, it was used a direct‑reading equipment that detects formaldehyde concentration by photoionization. Temperature and relative humidity were also measured in accordance with International Standard ISO 7726:1998. In the case of new dwellings, in 3 units concentration values were higher than 0.08 ppm. In addition, in 4 units of the 6 dwellings with occupation, concentrations higher than this reference value were obtained. The development of this study permitted to recognize some of the possible indoors emissions sources and to define several of the preventive measures that can be applied.
Resumo:
Introdução – Apesar de em Portugal se verificar o aumento da indústria da produção de aves para consumo humano, apenas alguns estudos incidem sobre a qualidade do ar interior e as implicações da sua degradação. Objectivos – Descrever a contaminação fúngica num aviário, analisar possíveis associações com a temperatura ambiente e a humidade relativa e o possível impacto na saúde dos consumidores e trabalhadores desta unidade. Métodos – Foi desenvolvido um estudo descritivo para avaliar a contaminação fúngica num aviário. Colheram‑se 5 amostras de ar de 100 litros através do método de compactação e 4 amostras de superfícies, utilizando a técnica da zaragatoa e um quadrado de 10 cm de lado de metal. Simultaneamente, os parâmetros ambientais – temperatura ambiente e humidade relativa – também foram medidos. Resultados – Foram identificadas vinte espécies de fungos no ar, sendo os seguintes os quatro géneros mais comummente isolados: Cladosporium (40,5%), Alternaria (10,8%), Chrysosporium e Aspergillus (6,8%). Nas superfícies, 21 espécies de fungos foram identificadas, sendo os 4 géneros mais identificados Penicillium (51,8%), Cladosporium (25,4%), Alternaria (6,1%) e Aspergillus (4,2%). Importa referir o facto de Aspergillus flavus, também isolado no ar, ser reconhecido como produtor de micotoxinas (aflatoxina) e Aspergillus fumigatus, uma das espécies isoladas no ar e superfícies, ser capaz de causar aspergilose grave ou fatal. Não se verificou relação significativa (p> 0,05) entre a contaminação fúngica e as variáveis ambientais. Conclusão – Caracterizou‑se a distribuição fúngica no ar e superfícies do aviário e analisou‑se a possível influência das variáveis ambientais. Foi reconhecido um potencial problema de Saúde Pública devido à contaminação fúngica e à possível produção de micotoxinas com a eventual contaminação dos produtos alimentares. A contaminação fúngica, particularmente causada pelo Aspergillus fumigatus, e a possível presença de micotoxinas no ar, devem ser encaradas também como fatores de risco neste contexto ocupacional. ABSTRACT - Background – Although there is an increasingly industry that produce whole chickens for domestic consumption in Portugal, only few investigations have reported on the indoor air of these plants and the consequences of their degradation. Objectives – Describe one poultry environmental fungal contamination analyse possible associations between temperature and relative humidity and its possible impact on the health of consumers and of the poultry workers. Methods – A descriptive study was developed to monitor one poultry fungal contamination. Five air samples of 100 litres through impaction method were collected and 4 swab samples from surfaces were also collected using a 10 cm square of metal. Simultaneously, environmental parameters – temperature and relative humidity – were also measured. Results – Twenty species of fungi in air were identified, being the 4 most commonly isolated the following genera: Cladosporium (40.5%), Alternaria (10.8%), Chrysosporium and Aspergillus (6.8%). In surfaces, 21 species of fungi were identified, being the 4 genera more identified Penicillium (51.8%), Cladosporium (25.4%), Alternaria (6.1%) and Aspergillus (4.2%). In addition, Aspergillus flavus also isolated in the poultry air is a well‑known producer of potent mycotoxins (aflatoxin), and Aspergillus fumigatus, one of the species isolated in air and surfaces, is capable of causing severe or fatal aspergillosis. There was no significant relationship (p>0,05) between fungal contamination and environmental variables. Conclusions – Was characterized fungal distribution in poultry air and surfaces and analyzed the association of environmental variables. It was recognized the Public Health problem because of fungal contamination and also due to probable mycotoxins production with the possible contamination of food products. Fungal contamination, particularly due to the presence of Aspergillus fumigatus and also the possible presence of mycotoxins in the air, should be seen as risk factor in this occupational setting.
Resumo:
In the printing industry, volatile organic compounds main sources are the uses of organic solvents, fountain solutions and cleaning agents. Nowadays, one circumstance which might confuse the exposure reality is that the majority of solvents which are often used have a faint odour. Therefore, the conditions at offset printing in regard to solvent exposure may seem acceptable to workers. Fortunately, general ventilation and local exhaust systems have also become more common, and new printing machines, often with automatic cleaning, have entered the market. The health effects of volatile organic solvents are dependent on the chemicals involved but, normally, are associated with affecting the nervous system, the liver and also the kidneys. The purpose of this study was to document the conditions regarding exposure to volatile organic compounds in an offset printing unit and to permit identify task with higher exposure and with priority for preventive measures application. Exposure assessment was done before and after installation of general ventilation and local exhaust equipments and during printing and cleaning procedure.
Resumo:
Perchloroethylene (also known as tetrachloroethylene) is a solvent that has been a mainstay of the dry cleaning industry for decades. Since 1995 the International Agency for Research on Cancer considers that dry cleaning entails exposures that are possibly carcinogenic to humans (Group 2B). Meanwhile, the same institution classified perchloroethylene as probably carcinogenic to humans (Group 2A). Some industries have begun using alternative cleaning methods that do not require the use of perchloroethylene. However, in Portugal this solvent is still the most common dry-cleaning agent. An exploratory study was developed that aimed to find the occupational exposure to perchloroethylene in four Portuguese dry-cleaning stores. Activities involving higher exposure and variables that promote exposure were also investigated. Real-time measurements of volatile organic compounds concentrations were performed using portable equipment (MultiRAE, RAE Systems model – calibrated by isobutylene).
Resumo:
A descriptive study was developed to compare air and surfaces fungal contamination in ten hospitals’ food units and two food units from companies. Fifty air samples of 250 litres through impaction method were collected from hospitals’ food units and 41 swab samples from surfaces were also collected, using a 10 by 10 cm square stencil. Regarding the two companies, ten air samples and eight surface samples were collected. Air and surface samples were collected in food storage facilities, kitchen, food plating and canteen. Outdoor air was also collected since this is the place regarded as a reference. Simultaneously, temperature, relative humidity and meal numbers were registered. Concerning air from hospitals’ food units, 32 fungal species were identified, being the two most commonly isolated genera Penicillium sp.
Resumo:
Moulds may produce a diversity of toxins such as aflatoxins, ochratoxins, trichothecenes, zearalenone, fumonisins and others. Although toxicological, environmental and epidemiological studies have addressed the problem of these toxins one by one, more than one mycotoxin are found usually in the same contaminated food. Risk assessment for humans potentially exposed to multimycotoxins suffers very much from the lack of adequate food consumption data. Furthermore, for a given mycotoxin, synergism and antagonism with other mycotoxins, found in the same food commodities, are not taken into account. Aflatoxin B1 and ochratoxin A belong to the most frequently occurring mycotoxins. This has repeatedly been demonstrated, however, normally, the risk resulting from their simultaneous occurrence is not considered. A descriptive study was developed to monitor air fungal contamination in one hospital food unit.
Ventilation influence in occupational exposure to fungi and volatile organic compounds: poultry case
Resumo:
Introduction - In poultry houses, large-scale production has led to increased bird densities within buildings. Such high densities of animals kept within confined spaces are a source of human health problems related to occupational organic dust exposure. This organic dust is composed of both non-viable particles and viable particulate matter (also called bioaerosols). Bioaerosols are comprised by airborne bacteria, fungi, viruses and their by-products, endotoxins and mycotoxins. Exposure to fungi in broiler houses may vary depending upon the applied ventilation system. Ventilation can be an important resource in order to reduce air contamination in these type of settings. Nevertheless, some concerns regarding costs, sensitivity of the animal species to temperature differences, and also the type of building used define which type of ventilation is used. Aim of the study - A descriptive study was developed in one poultry unit aiming to assess occupational fungal and volatile organic compounds (VOCs) exposure.
Resumo:
In this study, the results of chemical concentrations inside and outside of a Lisbon (Portugal) traffic tunnel were compared, during one week. They were obtained by Instrumental Neutron Activation Analysis (INAA). The tunnel values largely exceed the Air Ambient legislated values and the Pearson Correlations Coefficients point out to soil re-suspension/dispersed road dust (As, Ce, Eu, Hf, Fe, Mo, Sc, Zn), traffic-markers (Ba, Cr), tire wear (Cr, Zn), break wear (Fe, Zn, Ba, Cu, Sb), exhaust and motor oil (Zn) and sea-spray (Br, Na). On all days these elements inside the tunnel were more enriched than outside; significant statistical differences were found for Co (p=0.005), Br (p=0.008), Zn (p=0.01) and Sb (p=0.005), while enrichment factors of As and Sc are statistically identical. The highest values were found for As, Br, Zn and Sb, for both inside and outside the tunnel.
Resumo:
A biomonitoring study, using transplanted lichens Flavoparmelia caperata, was conducted to assess the indoor air quality in primary schools in urban (Lisbon) and rural (Ponte de Sor) Portuguese sites. The lichens exposure period occurred between April and June 2010 and two types of environments of the primary schools were studied: classrooms and outdoor/courtyard. Afterwards, the lichen samples were processed and analyzed by instrumental neutron activation analysis (INAA) to assess a total of 20 chemical elements. Accumulated elements in the exposed lichens were assessed and enrichment factors (EF) were determined. Indoor and outdoor biomonitoring results were compared to evaluate how biomonitors (as lichens) react at indoor environments and to assess the type of pollutants that are prevalent in those environments.
Resumo:
One Plus Sequential Air Sampler—Partisol was placed in a small village (Foros de Arrão) in central Portugal to collect PM10 (particles with an aerodynamic diameter below 10 μm), during the winter period for 3 months (December 2009–March 2010). Particles masses were gravimetrically determined and the filters were analyzed by instrumental neutron activation analysis to assess their chemical composition. The water-soluble ion compositions of the collected particles were determined by Ion-exchange Chromatography. Principal component analysis was applied to the data set of chemical elements and soluble ions to assess the main sources of the air pollutants. The use of both analytical techniques provided information about elemental solubility, such as for potassium, which was important to differentiate sources.
Resumo:
In this work, 14 primary schools of Lisbon city, Portugal, followed a questionnaire of the ISAAC - International Study of Asthma and Allergies in Childhood Program, in 2009/2010. The questionnaire contained questions to identify children with respiratory diseases (wheeze, asthma and rhinitis). Total particulate matter (TPM) was passively collected inside two classrooms of each of 14 primary schools. Two types of filter matrices were used to collect TPM: Millipore (IsoporeTM) polycarbonate and quartz. Three campaigns were selected for the measurement of TPM: Spring, Autumn and Winter. The highest difference between the two types of filters is that the mass of collected particles was higher in quartz filters than in polycarbonate filters, even if their correlation is excellent. The highest TPM depositions occurred between October 2009 and March 2010, when related with rhinitis proportion. Rhinitis was found to be related to TPM when the data were grouped seasonally and averaged for all the schools. For the data of 2006/2007, the seasonal variation was found to be related to outdoor particle deposition (below 10 μm).
Resumo:
Total particulate matter (TPM) was passively collected inside two classrooms of each of five elementary schools in Lisbon, Portugal. TPM was collected in polycarbonate filters with a 47 mm diameter, placed inside of uncovered plastic petri dishes. The sampling period was from 19 May to 22 June 2009 (35 days exposure) and the collected TPM masses varied between 0.2 mg and 0.8 mg. The major elements were Ca, Fe, Na, K, and Zn at μg level, while others were at ng level. Pearson′s correlation coefficients above 0.75 (a high degree of correlation) were found between several elements. Soil-related, traffic soil re-suspension and anthropogenic emission sources could be identified. Blackboard chalk was also identified through Ca large presence. Some of the determined chemical elements are potential carcinogenic. Quality control of the results showed good agreement as confirmed by the application of u-score test.
Resumo:
Nowadays, most individuals spend about 80% of their time indoor and, consequently, the exposure to the indoor environment becomes more relevant than to the outdoor one. Children spend most of their time at home and at school and evaluations of their indoor environment are important for the time-weighted exposure. Due to their airways still in development, children are a sensitive group with higher risk than adults. Larger impact in health and educational performance of children demand indoor air quality studies of schools. The aim of this study was to assess the children exposure to bioaerosols. A methodology based upon passive sampling was applied to evaluate fungi, bacteria and pollens; its procedures and applicability was optimized. An indoor air study by passive sampling represents an easier and cheaper method when comparing with the use of automatic active samplers. Furthermore, it is possible to achieve important quality information without interfering in the classroom activities. The study was conducted in three schools, representative of different environments in the Lisbon urban area, at three different periods of the year to obtain a seasonal variation, to estimate the variability through the city and to understand the underneath causes. Fungi and bacteria were collected indoor and outdoor of the classrooms to determine the indoor/outdoor ratios and to assess the level of outdoor contamination upon the indoor environment. The children's exposure to pollen grains inside the classrooms was also assessed.