22 resultados para brain SPECT


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The foot and the ankle are small structures commonly affected by disorders, and their complex anatomy represent significant diagnostic challenges. SPECT/CT Image fusion can provide missing anatomical and bone structure information to functional imaging, which is particularly useful to increase diagnosis certainty of bone pathology. However, due to SPECT acquisition duration, patient’s involuntary movements may lead to misalignment between SPECT and CT images. Patient motion can be reduced using a dedicated patient support. We aimed at designing an ankle and foot immobilizing device and measuring its efficacy at improving image fusion. Methods: We enrolled 20 patients undergoing distal lower-limb SPECT/CT of the ankle and the foot with and without a foot holder. The misalignment between SPECT and CT images was computed by manually measuring 14 fiducial markers chosen among anatomical landmarks also visible on bone scintigraphy. Analysis of variance was performed for statistical analysis. Results: The obtained absolute average difference without and with support was 5.1±5.2 mm (mean±SD) and 3.1±2.7 mm, respectively, which is significant (p<0.001). Conclusion: The introduction of the foot holder significantly decreases misalignment between SPECT and CT images, which may have clinical influence in the precise localization of foot and ankle pathology.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Myocardial perfusion gated-single photon emission computed tomography (gated-SPECT) imaging is used for the combined evaluation of myocardial perfusion and left ventricular (LV) function. The aim of this study is to analyze the influence of counts/pixel and concomitantly the total counts in the myocardium for the calculation of myocardial functional parameters. Material and methods: Gated-SPECT studies were performed using a Monte Carlo GATE simulation package and the NCAT phantom. The simulations of these studies use the radiopharmaceutical 99mTc-labeled tracers (250, 350, 450 and 680MBq) for standard patient types, effectively corresponding to the following activities of myocardium: 3, 4.2, 5.4-8.2MBq. All studies were simulated using 15 and 30s/projection. The simulated data were reconstructed and processed by quantitative-gated-SPECT software, and the analysis of functional parameters in gated-SPECT images was done by using Bland-Altman test and Mann-Whitney-Wilcoxon test. Results: In studies simulated using different times (15 and 30s/projection), it was noted that for the activities for full body: 250 and 350MBq, there were statistically significant differences in parameters Motility and Thickness. For the left ventricular ejection fraction (LVEF), end-systolic volume (ESV) it was only for 250MBq, and 350MBq in the end-diastolic volume (EDV), while the simulated studies with 450 and 680MBq showed no statistically significant differences for global functional parameters: LVEF, EDV and ESV. Conclusion: The number of counts/pixel and, concomitantly, the total counts per simulation do not significantly interfere with the determination of gated-SPECT functional parameters, when using the administered average activity of 450MBq, corresponding to the 5.4MBq of the myocardium, for standard patient types.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We present the modeling efforts on antenna design and frequency selection to monitor brain temperature during prolonged surgery using noninvasive microwave radiometry. A tapered log-spiral antenna design is chosen for its wideband characteristics that allow higher power collection from deep brain. Parametric analysis with the software HFSS is used to optimize antenna performance for deep brain temperature sensing. Radiometric antenna efficiency (eta) is evaluated in terms of the ratio of power collected from brain to total power received by the antenna. Anatomical information extracted from several adult computed tomography scans is used to establish design parameters for constructing an accurate layered 3-D tissue phantom. This head phantom includes separate brain and scalp regions, with tissue equivalent liquids circulating at independent temperatures on either side of an intact skull. The optimized frequency band is 1.1-1.6 GHz producing an average antenna efficiency of 50.3% from a two turn log-spiral antenna. The entire sensor package is contained in a lightweight and low-profile 2.8 cm diameter by 1.5 cm high assembly that can be held in place over the skin with an electromagnetic interference shielding adhesive patch. The calculated radiometric equivalent brain temperature tracks within 0.4 degrees C of the measured brain phantom temperature when the brain phantom is lowered 10. C and then returned to the original temperature (37 degrees C) over a 4.6-h experiment. The numerical and experimental results demonstrate that the optimized 2.5-cm log-spiral antenna is well suited for the noninvasive radiometric sensing of deep brain temperature.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Myocardial perfusion imaging (MPI) is used on a daily basis to access coronary blood flow in patients that are suspected or have known Coronary Artery Disease (CAD). A Single Photon Emission Computed Tomography (SPECT) or and Positron Emission Tomography (PET) scan are used to access regional blood flow quantification either at rest or stress, the imaging acquisition is connected to an Electrocardiogram (ECG) and it is able to determine and quantify other myocardial parameters like myocardial wall thickness and wall motion. PET is not used so broadly due to its high procedure cost, the proximity with cyclotron, where are produced the majority of radiopharmaceuticals used in PET, due to their shor thalf-life. This work is intended to carry out a review of the tests relating to radiopharmaceuticals that are used in clinical practice in SPECT or PET for assessment of myocardial perfusion, also focusing very promising radiopharmaceuticals that are under investigation or in clinical trials with great potential for conventional nuclear medicine or PET, proceeding to a comparative analysis of both techniques and respective radiopharmaceuticals used.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The DatScanTM and its Semiquantification (SQ) can provide advantages in the diagnosis of Parkinsonian Syndromes (PS). To improve the SQ is recommended the creation of adapted database (DB) with reference values for the Nuclear Medicine Departments. Previously to this work was created a adapted database (DBRV) to Nuclear Medicine Department's protocol and population of Infanta Cristina's Hospital located in Badajoz, for patients between the ages of 60 and 75, and reference values of the SQ were calculated. Aim: To evaluate the discrimination capacity of a department's adapted DB reference's values of healthy controls for DatScanTM.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Semi quantification (SQ) in DaTScan® studies is broadly used in clinic daily basis, however there is a suspicious about its discriminative capability, and concordance with the diagnostic classification performed by the physician. Aim: Evaluate the discriminate capability of an adapted database and reference's values of healthy controls for the Dopamine Transporters (DAT) with 123I–FP-IT named DBRV adapted to Nuclear Medicine Department's protocol and population of Infanta Cristina's Hospital, and its concordance with the physician classification.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Semiquantificação (SQ) nos exames de O DaTScanTM pode apresentar vantagens no diagnóstico de Síndromes Parkinsonianos (SP), especialmente quando os valores utilizados para referência da SQ são adaptados ao serviço em causa. Objetivo do estudo - Criação e validação de bases de dados e valores de referência (VR) adaptados na SQ para diagnóstico de SP recorrendo ao de DaTScanTM, adaptados para o Hospital Infanta Cristina em Badajoz.