54 resultados para Soft magnetic material


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The main properties of magnetized strangelets, namely, their energy per baryon, radius and electric charge, are studied in the unpaired strange quark matter phase. Temperature effects are taken into account in order to study their stability compared to the (56)Fe isotope and non-magnetized strangelets within the framework of the MIT bag model. It is concluded that the presence of a magnetic field tends to stabilize more the strangelets, even when temperature is considered. We find that the electric charge is modified in the presence of the magnetic field, leading to higher charge values for magnetized strangelets, when compared to the non-magnetized case.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We present a two-Higgs-doublet model, with a Z(3) symmetry, in which CP violation originates solely in a soft (dimension-2) coupling in the scalar potential, and reveals itself solely in the CKM (quark mixing) matrix. In particular, in the mass basis the Yukawa interactions of the neutral scalars are all real. The model has only eleven parameters to fit the six quark masses and the four independent CKM-matrix observables. We find regions of parameter space in which the flavour-changing neutral couplings are so suppressed that they allow the scalars to be no heavier than a few hundred GeV. (C) 2011 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Quando aplicada no âmbito da Anatomia Patológica, a imuno-histoquímica tem constituído um poderoso meio de identificação/caracterização de várias estruturas histológicas, permitindo delinear prognóstico e terapêutica para várias patologias. Tendo em conta que as amostras histológicas analisadas podem ser conservadas ao longo de vários anos, interessa avaliar a manutenção da antigenicidade ao longo do tempo, de forma a garantir a qualidade final da técnica quando aplicada em material de arquivo. Assim, o principal objetivo deste trabalho foi comparar a imunorreatividade do material histológico arquivado durante um, quatro e sete anos. Foi utilizado material histológico de próstata, pulmão e mama, no qual se procedeu à imunomarcação de citoqueratinas (Clones AE1/AE3), CD34 e proteína p63, por método de multímero/HRP no sistema Ventana BenchMark Ultra®. Foi realizado um ensaio com recuperação antigênica por alta temperatura (RAAT) e outro sem esta etapa. As imunomarcações (n=162) foram classificadas por três avaliadores independentes num escore quantitativo final (escala 0-100). O par média/desvio-padrão do escore final para os casos com sete anos foi de 69,06/19,05, para os casos com quatro anos foi de 66,47/20,73 e para os casos com um ano foi de 69,08/19,35, não se tendo encontrado diferenças estatisticamente significativas. Os casos sem RAAT obtiveram um par média/desvio-padrão de 54,90/17,00, enquanto os casos com RAAT obtiveram 81,50/11,60, o que revelou diferenças estatisticamente significativas (p=0,000). Para os casos em estudo conclui-se que o fator “tempo de arquivo” não está associado a alterações da imunorreatividade. A importância da RAAT na obtenção de imunomarcação de qualidade sai fortemente realçada. ABSTRACT - When applied within the framework of Pathology, immunohistochemistry has been a powerful means of identification/characterization of various histological structures, allowing to outline prognosis and therapy for various diseases. Given that the analyzed histological samples can be preserved for several years, it is interesting to assess the retention of antigenicity over time in order to ensure the quality of the final technique, when applied to stored material. Thus, the main objective of this study was to compare the immunoreactivity of the histological material archived for one, four and seven years. It was used histological material from prostate, lung and breast, in which it was performed the immunostaining of cytokeratins (clones AE1/AE3), CD34 and p63 protein by the method of multimer/HRP system on a Ventana BenchMark Ultra®. It was conducted a test with heat induced epitope retrieval (HIER) and another one without this step. The stained slides (n=162) were classified by three independent assessors using a quantitative score (scale 0-100). The pair mean/standard deviation of the score for cases with seven years was 69,06/19,05, for cases with four years was 66,47/20,73 and for cases with one year was 69,08/19,35, which did not revealed any statistically significant differences. The cases without HIER had a couple mean/standard deviation of 54.90/17.00 while the cases with HIER obtained 81.50/11.60, which revealed statistically significant differences (p=0.000). For this case study it was concluded that the factor archive period is not associated with changes in immunoreactivity. The importance of HIER in obtaining high quality immunostaining comes out strongly highlighted.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Claustrophobia causes a huge discomfort to those who need to perform Magnetic Resonance examinations mainly due to the physical design of most equipment. This study aimed to maximize the success rate of Magnetic Resonance Imaging (MRI) clinical studies in claustrophobic patients by the identification of facilitative strategies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The characteristics of tunable wavelength filters based on a-SiC:H multilayered stacked pin cells are studied both theoretically and experimentally. The optical transducers were produced by PECVD and tested for a proper fine tuning of the cyan and yellow fluorescent proteins emission. The active device consists of a p-i'(a-SiC:H)-n/p-i(a-Si:H)-n heterostructures sandwiched between two transparent contacts. Experimental data on spectral response analysis, current-voltage characteristics and color and transmission rate discrimination are reported. Cyan and yellow fluorescent input channels were transmitted together, each one with a specific transmission rate and different intensities. The multiplexed optical signal was analyzed by reading out, under positive and negative applied voltages, the generated photocurrents. Results show that the optimized optical transducer has the capability of combining the transient fluorescent signals onto a single output signal without losing any specificity (color and intensity). It acts as a voltage controlled optical filter: when the applied voltages are chosen appropriately the transducer can select separately the cyan and yellow channel emissions (wavelength and frequency) and also to quantify their relative intensities. A theoretical analysis supported by a numerical simulation is presented.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We describe a novel, low-cost and low-tech method for the fabrication of elastomeric Janus particles with diameters ranging from micrometers to millimeters. This consists of UV-irradiating soft urethane/urea elastomer spheres, which are then extracted in toluene and dried. The spheres are thus composed of a single material: no coating or film deposition steps are required. Furthermore, the whole procedure is carried out at ambient temperature and pressure. Long, labyrinthine corrugations ("wrinkles") appear on the irradiated portions of the particles' surfaces, the spatial periodicity of which can be controlled by varying the sizes of particles. The asymmetric morphology of the resulting Janus particles has been confirmed by scanning electron microscopy, atomic force microscopy, and optical microscopy. We have also established that the spheres behave elastically by performing bouncing tests with dried and swollen spheres. Results can be interpreted by assuming that each sphere consists of a thin, stiff surface layer ("skin") lying atop a thicker, softer substrate ("bulk"). The skin's higher stiffness is hypothesized to result from the more extensive cross-linking of the polymer chains located near the surface by the UV radiation. Textures then arise from competition between the effects of bending the skin and compressing the bulk, as the solvent evaporates and the sphere shrinks.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O âmbito da presente tese é o estudo de juntas mecânicas em material compósito realizado com fibra de vidro. Os materiais compósitos são a solução procurada pela generalidade dos sectores da indústria, devido essencialmente à sua grande capacidade estrutural e à sua resistência mecânica específica, ou seja, a resistência mecânica versus peso ser em geral maior que nas ligações metálicas. O estudo efectuado neste trabalho é referente à delaminação presente na furação de materiais compósitos, sendo esta um dos problemas de maior gravidade, existente quando se realiza a furação do material. Este problema influência a integridade estrutural do material bem como a sua fiabilidade a longo prazo. Foram usados dois métodos de furação, o primeiro conhecido por furação convencional e o segundo habitualmente designado método KTH ou por furação orbital. Foi feita uma comparação entre estes dois métodos e verificado qual deles apresenta menor delaminação em torno do furo e melhor qualidade de furo. Conclui-se que a furação orbital apresenta uma delaminação inferior relativamente à furação convencional, e que esta é preferível para a realização de furação em material compósito.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper is a contribution for the assessment and comparison of magnet properties based on magnetic field characteristics particularly concerning the magnetic induction uniformity in the air gaps. For this aim, a solver was developed and implemented to determine the magnetic field of a magnetic core to be used in Fast Field Cycling (FFC) Nuclear Magnetic Resonance (NMR) relaxometry. The electromagnetic field computation is based on a 2D finite-element method (FEM) using both the scalar and the vector potential formulation. Results for the magnetic field lines and the magnetic induction vector in the air gap are presented. The target magnetic induction is 0.2 T, which is a typical requirement of the FFC NMR technique, which can be achieved with a magnetic core based on permanent magnets or coils. In addition, this application requires high magnetic induction uniformity. To achieve this goal, a solution including superconducting pieces is analyzed. Results are compared with a different FEM program.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We investigate, via numerical simulations, mean field, and density functional theories, the magnetic response of a dipolar hard sphere fluid at low temperatures and densities, in the region of strong association. The proposed parameter-free theory is able to capture both the density and temperature dependence of the ring-chain equilibrium and the contribution to the susceptibility of a chain of generic length. The theory predicts a nonmonotonic temperature dependence of the initial (zero field) magnetic susceptibility, arising from the competition between magnetically inert particle rings and magnetically active chains. Monte Carlo simulation results closely agree with the theoretical findings. DOI: 10.1103/PhysRevLett.110.148306

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Here we report on the structural, optical, electrical and magnetic properties of Co-doped and (Co,Mo)-codoped SnO2 thin films deposited on r-cut sapphire substrates by pulsed laser deposition. Substrate temperature during deposition was kept at 500 degrees C. X-ray diffraction analysis showed that the undoped and doped films are crystalline with predominant orientation along the [1 0 1] direction regardless of the doping concentration and doping element. Optical studies revealed that the presence of Mo reverts the blue shift trend observed for the Co-doped films. For the Co and Mo doping concentrations studied, the incorporation of Mo did not contribute to increase the conductivity of the films or to enhance the ferromagnetic order of the Co-doped films. (C) 2012 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Monte Carlo (MC) dose calculation algorithms have been widely used to verify the accuracy of intensity-modulated radiotherapy (IMRT) dose distributions computed by conventional algorithms due to the ability to precisely account for the effects of tissue inhomogeneities and multileaf collimator characteristics. Both algorithms present, however, a particular difference in terms of dose calculation and report. Whereas dose from conventional methods is traditionally computed and reported as the water-equivalent dose (Dw), MC dose algorithms calculate and report dose to medium (Dm). In order to compare consistently both methods, the conversion of MC Dm into Dw is therefore necessary. This study aims to assess the effect of applying the conversion of MC-based Dm distributions to Dw for prostate IMRT plans generated for 6 MV photon beams. MC phantoms were created from the patient CT images using three different ramps to convert CT numbers into material and mass density: a conventional four material ramp (CTCREATE) and two simplified CT conversion ramps: (1) air and water with variable densities and (2) air and water with unit density. MC simulations were performed using the BEAMnrc code for the treatment head simulation and the DOSXYZnrc code for the patient dose calculation. The conversion of Dm to Dw by scaling with the stopping power ratios of water to medium was also performed in a post-MC calculation process. The comparison of MC dose distributions calculated in conventional and simplified (water with variable densities) phantoms showed that the effect of material composition on dose-volume histograms (DVH) was less than 1% for soft tissue and about 2.5% near and inside bone structures. The effect of material density on DVH was less than 1% for all tissues through the comparison of MC distributions performed in the two simplified phantoms considering water. Additionally, MC dose distributions were compared with the predictions from an Eclipse treatment planning system (TPS), which employed a pencil beam convolution (PBC) algorithm with Modified Batho Power Law heterogeneity correction. Eclipse PBC and MC calculations (conventional and simplified phantoms) agreed well (<1%) for soft tissues. For femoral heads, differences up to 3% were observed between the DVH for Eclipse PBC and MC calculated in conventional phantoms. The use of the CT conversion ramp of water with variable densities for MC simulations showed no dose discrepancies (0.5%) with the PBC algorithm. Moreover, converting Dm to Dw using mass stopping power ratios resulted in a significant shift (up to 6%) in the DVH for the femoral heads compared to the Eclipse PBC one. Our results show that, for prostate IMRT plans delivered with 6 MV photon beams, no conversion of MC dose from medium to water using stopping power ratio is needed. In contrast, MC dose calculations using water with variable density may be a simple way to solve the problem found using the dose conversion method based on the stopping power ratio.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In basaltic dykes the magnetic lineation K1 (maximum magnetic susceptibility axis) is generally taken to indicate the flow direction during solidification of the magma. This assumption was tested in Tertiary basaltic dykes from Greenland displaying independent evidence of subhorizontal flow. The digital processing of microphotographs from thin sections cut in (K1, K2) planes yields the preferred linear orientation of plagioclase, which apparently marks the magma flow lineation. In up to 60% of cases, the angular separation between K1 and the assumed flow direction is greater than 45degrees. This suggests that the uncorroborated use of magnetic lineations in dykes is risky. A simple geometrical method is proposed to infer the flow vector from AMS in dykes based solely on magnetic foliations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The amount of fat is a component that complicates the clinical evaluation and the differential diagnostic between benign and malign lesions in the breast MRI examinations. To overcome this problem, an effective erasing of the fat signal over the images acquisition process, is essentials. This study aims to compare three fat suppression techniques (STIR, SPIR, SPAIR) in the MR images of the breast and to evaluate the best image quality regarding its clinical usefulness. To mimic breast women, a breast phantom was constructed. First the exterior contour and, in second time, its content which was selected based on 7 samples with different components. Finally it was undergone to a MRI breast protocol with the three different fat saturation techniques. The examinations were performed on a 1.5 T MRI system (Philips®). A group of 5 experts evaluated 9 sequences, 3 of each with fat suppression techniques, in which the frequency offset and TI (Inversion Time) were the variables changed. This qualitative image analysis was performed according 4 parameters (saturation uniformity, saturation efficacy, detail of the anatomical structures and differentiation between the fibroglandular and adipose tissue), using a five-point Likert scale. The statistics analysis showed that anyone of the fat suppression techniques demonstrated significant differences compared to the others with (p > 0.05) and regarding each parameter independently. By Fleiss’ kappa coefficient there was a good agreement among observers P(e) = 0.68. When comparing STIR, SPIR and SPAIR techniques it was confirmed that all of them have advantages in the study of the breast MRI. For the studied parameters, the results through the Friedman Test showed that there are similar advantages applying anyone of these techniques.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A celulose é o polímero renovável mais abundante do mundo. É conhecido pela sua excelente biocompatibilidade, propriedades térmicas e mecânicas. A celulose assim como os polipéptideos e o ADN, pertence a uma família de moléculas orgânicas que dão origem à formação de fases líquidas cristalinas (LCs) colestéricas. A Passiflora Edulis, tal como outras plantas trepadeiras, possui longas e flexíveis gavinhas que permitem à planta encontrar um suporte para se fixar. As gavinhas podem assumir a forma de espirais ou de hélices consoante sejam sustentadas por apenas uma ou por ambas as extremidades. As hélices apresentam muitas vezes duas porções helicoidais, uma esquerda e outra direita, separadas por um segmento recto denominado perversão. Este comportamento é consequência da curvatura intrínseca das gavinhas produzidas pela planta trepadeira. O mesmo comportamento pode ser observado em micro e nanofibras celulósicas fabricadas a partir de soluções líquido-cristalinas, numa escala três a quatro ordens de grandeza inferior à das gavinhas. Este facto sugere que o modelo físico utilizado tenha invariância de escala. Neste trabalho é feito o estudo de fibras e jactos que imitam as estruturas helicoidais apresentadas pelas gavinhas das plantas trepadeiras. As fibras e jactos são produzidos a partir de soluções líquidas cristalinas celulósicas. De modo a determinar as características morfológicas e estruturais, que contribuem para a curvatura das fibras, foram utilizadas técnicas de imagem por ressonância magnética (MRI), microscopia óptica com luz polarisada (MOP), microscopia electrónica de varrimento (SEM) e microscopia de força atómica (AFM) . A variação da forma das estruturas helicoidais com a temperatura parece ser relevante para o fabrico de membranas não tecidas para aplicação em sensores termo-mecânicos.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A ressonância magnética fetal é um método eficaz na avaliação pré-natal da morfologia normal do cérebro e no diagnóstico de patologias do sistema nervoso central, sendo um importante complemento clínico à ecografia. O cerebelo é uma das estruturas menos afetadas em casos de restrição de crescimento fetal, tornando-se um bom indicador na avaliação do desenvolvimento fetal e da idade gestacional. Deste modo, a avaliação biométrica fetal é fundamental no diagnóstico pré-natal do desenvolvimento cerebral. Objetivo – Avaliação do diâmetro transversal do cerebelo (estrutura anatómica de referência do sistema nervoso central) do feto e posterior comparação com um estudo internacional reconhecido nesta matéria. Material e métodos – A amostra foi constituída por 84 gestantes que realizaram ressonância magnética fetal numa clínica de imagiologia médica da região Centro. A medição considerada para a avaliação do desenvolvimento fetal foi o diâmetro transversal do cerebelo. Resultados – Os resultados obtidos para o diâmetro transversal do cerebelo por ressonância magnética fetal vieram a demonstrar a ausência de diferenças médias estatisticamente significativas (p>0,05) em função do número de semanas de gestação, face aos valores teóricos aferidos no estudo de Garel. Conclusão – Com base nos resultados obtidos, para o diâmetro transversal do cerebelo podemos concluir que o parâmetro analisado é coerente com a publicação de Catherine Garel – Le développement du cerveau foetal atlas IRM et biometrie.