27 resultados para MEDICAL DEVICES
Resumo:
Exposure in a hospital setting is normally due to the use of several antineoplastic drugs simultaneously. Nevertheless, the effects of such mixtures at the cell level and on human health in general are unpredictable and unique due to differences in practice of hospital oncology departments, in the number of patients, protection devices available, and the experience and safety procedures of medical staff. Health care workers who prepare or administer hazardous drugs or who work in areas where these drugs are used may be exposed to these agents in the air, on work surfaces, contaminated clothing, medical equipment, patient excreta, and other surfaces. These workers include specially pharmacists, pharmacy technicians, and nursing personnel. Exposures may occur through inhalation resulting from aerosolization of powder or liquid during reconstitution and spillage taking place while preparing or administering to patients, through Cytokinesis-block micronucleus test (CBMN) is extensively used in biomonitoring, since it determines several biomarkers of genotoxicity, such as micronuclei (MN), which are biomarkers of chromosomes breakage or loss, nucleoplasmic bridges (NPB), common biomarkers of chromosome rearrangement, poor repair and/or telomeres fusion, and nuclear buds (NBUD), biomarkers of elimination of amplified DNA.
Resumo:
Mestrado em Radiações Aplicadas às Tecnologias da Saúde- Ramo de especialização: Terapia com Radiações
Resumo:
Medical imaging is a powerful diagnostic tool. Consequently, the number of medical images taken has increased vastly over the past few decades. The most common medical imaging techniques use X-radiation as the primary investigative tool. The main limitation of using X-radiation is associated with the risk of developing cancers. Alongside this, technology has advanced and more centres now use CT scanners; these can incur significant radiation burdens compared with traditional X-ray imaging systems. The net effect is that the population radiation burden is rising steadily. Risk arising from X-radiation for diagnostic medical purposes needs minimising and one way to achieve this is through reducing radiation dose whilst optimising image quality. All ages are affected by risk from X-radiation however the increasing population age highlights the elderly as a new group that may require consideration. Of greatest concern are paediatric patients: firstly they are more sensitive to radiation; secondly their younger age means that the potential detriment to this group is greater. Containment of radiation exposure falls to a number of professionals within medical fields, from those who request imaging to those who produce the image. These staff are supported in their radiation protection role by engineers, physicists and technicians. It is important to realise that radiation protection is currently a major European focus of interest and minimum competence levels in radiation protection for radiographers have been defined through the integrated activities of the EU consortium called MEDRAPET. The outcomes of this project have been used by the European Federation of Radiographer Societies to describe the European Qualifications Framework levels for radiographers in radiation protection. Though variations exist between European countries radiographers and nuclear medicine technologists are normally the professional groups who are responsible for exposing screening populations and patients to X-radiation. As part of their training they learn fundamental principles of radiation protection and theoretical and practical approaches to dose minimisation. However dose minimisation is complex – it is not simply about reducing X-radiation without taking into account major contextual factors. These factors relate to the real world of clinical imaging and include the need to measure clinical image quality and lesion visibility when applying X-radiation dose reduction strategies. This requires the use of validated psychological and physics techniques to measure clinical image quality and lesion perceptibility.
Resumo:
The purpose of this paper is the design of an optoelectronic circuit based on a-SiC technology, able to act simultaneously as a 4-bit binary encoder or a binary decoder in a 4-to-16 line configurations and show multiplexer-based logical functions. The device consists of a p-i'(a-SiC:H)-n/p-i(a-Si:H)-n multilayered structure produced by PECVD. To analyze it under information-modulated wave (color channels) and uniform irradiation (background) four monochromatic pulsed lights (input channels): red, green, blue and violet shine on the device. Steady state optical bias was superimposed separately from the front and the back sides, and the generated photocurrent was measured. Results show that the devices, under appropriate optical bias, act as reconfigurable active filters that allow optical switching and optoelectronic logic functions development providing the possibility for selective removal of useless wavelengths. The logic functions needed to construct any other complex logic functions are the NOT, and both or either an AND or an OR. Any other complex logic function that might be found can also be used as building blocks to achieve the functions needed for the retrieval of channels within the WDM communication link. (C) 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim
Resumo:
Aims of study: 1) Describe the importance of human visual system on lesion detection in medical imaging perception research; 2) Discuss the relevance of research in medical imaging addressing visual function analysis; 3) Identify visual function tests which could be conducted on observers prior to participation in medical imaging perception research.
Resumo:
In this paper we present results about the functioning of a multilayered a-SiC:H heterostructure as a device for wavelength-division demultiplexing of optical signals. The device is composed of two stacked p-i-n photodiodes, both optimized for the selective collection of photogenerated carriers. Band gap engineering was used to adjust the photogeneration and recombination rates profiles of the intrinsic absorber regions of each photodiode to short and long wavelength absorption and carrier collection in the visible spectrum. The photocurrent signal using different input optical channels was analyzed at reverse and forward bias and under steady state illumination. This photocurrent is used as an input for a demux algorithm based on the voltage controlled sensitivity of the device. The device functioning is explained with results obtained by numerical simulation of the device, which permit an insight to the internal electric configuration of the double heterojunction.These results address the explanation of the device functioning in the frequency domain to a wavelength tunable photocapacitance due to the accumulation of space charge localized at the internal junction. The existence of a direct relation between the experimentally observed capacitive effects of the double diode and the quality of the semiconductor materials used to form the internal junction is highlighted.
Resumo:
Characteristics of tunable wavelength pi'n/pin filters based on a-SiC:H multilayered stacked cells are studied both experimentally and theoretically. Results show that the device combines the demultiplexing operation with the simultaneous photodetection and self amplification of the signal. An algorithm to decode the multiplex signal is established. A capacitive active band-pass filter model is presented and supported by an electrical simulation of the state variable filter circuit. Experimental and simulated results show that the device acts as a state variable filter. It combines the properties of active high-pass and low-pass filter sections into a capacitive active band-pass filter using a changing capacitance to control the power delivered to the load.
Resumo:
Background - Medical image perception research relies on visual data to study the diagnostic relationship between observers and medical images. A consistent method to assess visual function for participants in medical imaging research has not been developed and represents a significant gap in existing research. Methods - Three visual assessment factors appropriate to observer studies were identified: visual acuity, contrast sensitivity, and stereopsis. A test was designed for each, and 30 radiography observers (mean age 31.6 years) participated in each test. Results - Mean binocular visual acuity for distance was 20/14 for all observers. The difference between observers who did and did not use corrective lenses was not statistically significant (P = .12). All subjects had a normal value for near visual acuity and stereoacuity. Contrast sensitivity was better than population norms. Conclusion - All observers had normal visual function and could participate in medical imaging visual analysis studies. Protocols of evaluation and populations norms are provided. Further studies are necessary to understand fully the relationship between visual performance on tests and diagnostic accuracy in practice.
Resumo:
Trabalho Final de Mestrado para obtenção do grau de Mestre em Engenharia Informática e de Computadores
Resumo:
Trabalho de Projeto realizado para obtenção do grau de Mestre em Engenharia Informática e de Computadores
Resumo:
Introdução – A pesquisa de informação realizada pelos estudantes de ensino superior em recursos eletrónicos não corresponde necessariamente ao domínio de competências de pesquisa, análise, avaliação, seleção e bom uso da informação recuperada. O conceito de literacia da informação ganha pertinência e destaque, na medida em que abarca competências que permitem reconhecer quando é necessária a informação e de atuar de forma eficiente e efetiva na sua obtenção e utilização. Objetivo – A meta da Escola Superior de Tecnologia da Saúde de Lisboa (ESTeSL) foi a formação em competências de literacia da informação, fora da ESTeSL, de estudantes, professores e investigadores. Métodos – A formação foi integrada em projetos nacionais e internacionais, dependendo dos públicos-alvo, das temáticas, dos conteúdos, da carga horária e da solicitação da instituição parceira. A Fundação Calouste Gulbenkian foi o promotor financeiro privilegiado. Resultados – Decorreram várias intervenções em território nacional e internacional. Em 2010, em Angola, no Instituto Médio de Saúde do Bengo, formação de 10 bibliotecários sobre a construção e a gestão de uma biblioteca de saúde e introdução à literacia da informação (35h). Em 2014, decorrente do ERASMUS Intensive Programme, o OPTIMAX (Radiation Dose and Image Quality Optimisation in Medical Imaging) para 40 professores e estudantes de radiologia (oriundos de Portugal, Reino Unido, Noruega, Países Baixos e Suíça) sobre metodologia e pesquisa de informação na MEDLINE e na Web of Science e sobre o Mendeley, enquanto gestor de referências (4h). Os trabalhos finais deste curso foram publicados em formato de ebook (http://usir.salford.ac.uk/34439/1/Final%20complete%20version.pdf), cuja revisão editorial foi da responsabilidade dos bibliotecários. Ao longo de 2014, na Escola Superior de Educação, Escola Superior de Dança, Instituto Politécnico de Setúbal e Faculdade de Medicina de Lisboa e, ao longo de 2015, na Universidade Aberta, Escola Superior de Comunicação Social, Instituto Egas Moniz, Faculdade de Letras de Lisboa e Centro de Linguística da Universidade de Lisboa foram desenhados conteúdos sobre o uso do ZOTERO e do Mendeley para a gestão de referências bibliográficas e sobre uma nova forma de fazer investigação. Cada uma destas sessões (2,5h) envolveu cerca de 25 estudantes finalistas, mestrandos e professores. Em 2015, em Moçambique, no Instituto Superior de Ciências da Saúde, decorreu a formação de 5 bibliotecários e 46 estudantes e professores (70h). Os conteúdos ministrados foram: 1) gestão e organização de uma biblioteca de saúde (para bibliotecários); 2) literacia da informação: pesquisa de informação na MEDLINE, SciELO e RCAAP, gestores de referências e como evitar o plágio (para bibliotecários e estudantes finalistas de radiologia). A carga horária destinada aos estudantes incluiu a tutoria das monografias de licenciatura, em colaboração com mais duas professoras do projeto. Para 2016 está agendada formação noutras instituições de ensino superior nacionais. Perspetiva-se, ainda, formação similar em Timor-Leste, cujos conteúdos, datas e carga horária estão por agendar. Conclusões – Destas iniciativas beneficia a instituição (pela visibilidade), os bibliotecários (pelo evidenciar de competências) e os estudantes, professores e investigadores (pelo ganho de novas competências e pela autonomia adquirida). O projeto de literacia da informação da ESTeSL tem contribuído de forma efetiva para a construção e para a produção de conhecimento no meio académico, nacional e internacional, sendo a biblioteca o parceiro privilegiado nesta cultura de colaboração.
Resumo:
The capability to anticipate a contact with another device can greatly improve the performance and user satisfaction not only of mobile social network applications but of any other relying on some form of data harvesting or hoarding. One of the most promising approaches for contact prediction is to extrapolate from past experiences. This paper investigates the recurring contact patterns observed between groups of devices using an 8-year dataset of wireless access logs produced by more than 70000 devices. This effort permitted to model the probabilities of occurrence of a contact at a predefined date between groups of devices using a power law distribution that varies according to neighbourhood size and recurrence period. In the general case, the model can be used by applications that need to disseminate large datasets by groups of devices. As an example, the paper presents and evaluates an algorithm that provides daily contact predictions, based on the history of past pairwise contacts and their duration. Copyright © 2015 ICST.