25 resultados para Electrolyte-gated transistor


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Trabalho Final de Mestrado para obtenção do grau de Mestre em Engenharia Química e Biológica Ramo de Processos Químicos

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A new integrated mathematical model for the simulation of offshore wind energy conversion system performance is presented in this paper. The mathematical model considers an offshore variable-speed turbine in deep water equipped with a permanent magnet synchronous generator using full-power two-level converter, converting the energy of a variable frequency source in injected energy into the electric network with constant frequency, through a high voltage DC transmission submarine cable. The mathematical model for the drive train is a concentrate two mass model which incorporates the dynamic for the structure and tower due to the need to emulate the effects of the moving surface. Controller strategy considered is a proportional integral one. Also, pulse width modulation using space vector modulation supplemented with sliding mode is used for trigger the transistor of the converter. Finally, a case study is presented to access the system performance. © 2014 IEEE.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A new integrated mathematical model for the simulation of offshore wind energy conversion system performance is presented in this paper. The mathematical model considers an offshore variable-speed turbine in deep water equipped with a permanent magnet synchronous generator using full-power two-level converter, converting the energy of a variable frequency source in injected energy into the electric network with constant frequency, through a high voltage DC transmission submarine cable. The mathematical model for the drive train is a concentrate two mass model which incorporates the dynamic for the structure and tower due to the need to emulate the effects of the moving surface. Controller strategy considered is a proportional integral one. Also, pulse width modulation using space vector modulation supplemented with sliding mode is used for trigger the transistor of the converter. Finally, a case study is presented to access the system performance. © 2014 IEEE.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Nickel-copper metallic foams were electrodeposited from an acidic electrolyte, using hydrogen bubble evolution as a dynamic template. Their morphology and chemical composition was studied by scanning electron microscopy and related to the deposition parameters (applied current density and deposition time). For high currents densities (above 1 A cm(-2)) the nickel-copper deposits have a three-dimensional foam-like morphology with randomly distributed nearly-circular pores whose walls present an open dendritic structure. The nickel-copper foams are crystalline and composed of pure nickel and a copper-rich phase containing nickel in solid solution. The electrochemical behaviour of the material was studied by cyclic voltammetry and chronopotentiometry (charge-discharge curves) aiming at its application as a positive electrode for supercapacitors. Cyclic voltammograms showed that the Ni-Cu foams have a pseudocapacitive behaviour. The specific capacitance was calculated from charge-discharge data and the best value (105 F g(-1) at 1 mA cm(-2)) was obtained for nickel-copper foams deposited at 1.8 A cm(-2) for 180 s. Cycling stability of these foams was also assessed and they present a 90 % capacitance retention after 10,000 cycles at 10 mA cm(-2).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Mg alloys can be used as bioresorsable metallic implants. However, the high corrosion rate of magnesium alloys has limited their biomedical applications. Although Mg ions are essential to the human body, an excess may cause undesirable health effects. Therefore, surface treatments are required to enhance the corrosion resistance of magnesium parts, decreasing its rate to biocompatible levels and allowing its safe application as bioresorbable metallic implants. The application of biocompatible silane coatings is envisaged as a suitable strategy for retarding the corrosion process of magnesium alloys. In the current work, a new glycidoxypropyltrimethoxysilane (GPTMS) based coating was tested on AZ31 magnesium substrates subjected to different surface conditioning procedures before coating deposition. The surface conditioning included a short etching with hydrofluoric acid (HF) or a dc polarisation in alkaline electrolyte. The silane coated samples were immersed in Hank's solution and the protective performance of the coating was studied through electrochemical impedance spectroscopy (EIS). The EIS data was treated by new equivalent circuit models and the results revealed that the surface conditioning process plays a key role in the effectiveness of the silane coating. The HF treated samples led to the highest impedance values and delayed the coating degradation, compared to the mechanically polished samples or to those submitted to dc polarisation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Passive films were grown in potentiodynamic mode, by cyclic voltammetry on AISI 316 and AISI 304 stainless steels. The composition of these films was investigated by X-ray photoelectron spectroscopy (XPS). The electrochemical behaviour and the chemical composition of the passive films formed by cyclic voltammetry were compared to those of films grown under natural conditions (by immersion at open circuit potential, OCP) in alkaline solutions simulating concrete. The study included the effect of pH of the electrolyte and the effect of the presence of chloride ions. The XPS results revealed important changes in the passive film composition, which becomes enriched in chromium and depleted in magnetite as the pH decreases. On the other hand, the presence of chlorides promotes a more oxidised passive layer. The XPS results also showed relevant differences on the composition of the oxide layers for the films formed under cyclic voltammetry and/or under OCP.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Trabalho Final de Mestrado para obtenção do grau de Mestre em Engenharia Electrotécnica Ramo de Automação e Electrónica Industrial

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introdução – A cintigrafia de perfusão do miocárdio (CPM) desempenha um importante papel no diagnóstico, avaliação e seguimento de pacientes com doença arterial coronária, sendo o seu processamento realizado maioritariamente de forma semiautomática. Uma vez que o desempenho dos técnicos de medicina nuclear (TMN) pode ser afetado por fatores individuais e ambientais, diferentes profissionais que processem os mesmos dados poderão obter diferentes estimativas dos parâmetros quantitativos (PQ). Objetivo – Avaliar a influência da experiência profissional e da função visual no processamento semiautomático da CPM. Analisar a variabilidade intra e interoperador na determinação dos PQ funcionais e de perfusão. Metodologia – Selecionou-se uma amostra de 20 TMN divididos em dois grupos, de acordo com a sua experiência no software Quantitative Gated SPECTTM: Grupo A (GA) – TMN ≥600h de experiência e Grupo B (GB) – TMN sem experiência. Submeteram-se os TMN a uma avaliação ortóptica e ao processamento de 21 CPM, cinco vezes, não consecutivas. Considerou-se uma visão alterada quando pelo menos um parâmetro da função visual se encontrava anormal. Para avaliar a repetibilidade e a reprodutibilidade recorreu-se à determinação dos coeficientes de variação, %. Na comparação dos PQ entre operadores, e para a análise do desempenho entre o GA e GB, aplicou-se o Teste de Friedman e de Wilcoxon, respetivamente, considerando o processamento das mesmas CPM. Para a comparação de TMN com visão normal e alterada na determinação dos PQ utilizou-se o Teste Mann-Whitney e para avaliar a influência da visão para cada PQ recorreu-se ao coeficiente de associação ETA. Diferenças estatisticamente significativas foram assumidas ao nível de significância de 5%. Resultados e Discussão – Verificou-se uma reduzida variabilidade intra (<6,59%) e inter (<5,07%) operador. O GB demonstrou ser o mais discrepante na determinação dos PQ, sendo a parede septal (PS) o único PQ que apresentou diferenças estatisticamente significativas (zw=-2,051, p=0,040), em detrimento do GA. No que se refere à influência da função visual foram detetadas diferenças estatisticamente significativas apenas na fração de ejeção do ventrículo esquerdo (FEVE) (U=11,5, p=0,012) entre TMN com visão normal e alterada, contribuindo a visão em 33,99% para a sua variação. Denotaram-se mais diferenças nos PQ obtidos em TMN que apresentam uma maior incidência de sintomatologia ocular e uma visão binocular diminuída. A FEVE demonstrou ser o parâmetro mais consistente entre operadores (1,86%). Conclusão – A CPM apresenta-se como uma técnica repetível e reprodutível, independente do operador. Verificou-se influência da experiência profissional e da função visual no processamento semiautomático da CPM, nos PQ PS e FEVE, respetivamente.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Master Thesis to obtain the Master degree in Chemical Engineering - Branch Chemical Processes

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Electrochemically-reduced graphene oxide (Er-GO) and cobalt oxides (CoOx) were co-electrodeposited by cyclic voltammetry, from an electrolyte containing graphene oxide and cobalt nitrate, directly onto a stainless steel substrate to produce composite electrodes presenting high charge storage capacity. The electrochemical response of the composite films was optimized by studying the parameters applied during the electrodeposition process, namely the number of cycles, scan rate and ratio between GO/Co(NO3)(2) concentrations in the electrolyte. It is shown that, if the appropriate conditions are selected, it is possible to produced binder-free composite electrodes with improved electrochemical properties using a low-cost, facile and scalable technique. The optimized Er-GO/CoOx developed in this work exhibits a specific capacitance of 608 F g(-1) at a current density of 1 A g(-1) and increased reversibility when compared to single CoOx. (C) 2015 Elsevier B.V. All rights reserved.