31 resultados para Building Systems
Resumo:
The current study focuses on the analysis of pressure surge damping in single pipeline systems generated by a fast change of flow, conditions. A dimensionless form of pressurised transient flow equations was developed. presenting the main advantage of being independent of the system characteristics. In lack of flow velocity profiles. the unsteady friction in turbulent regimes is analysed based on two new empirical corrective-coefficients associated with local and convective acceleration terms. A new, surge damping approach is also presented taking into account the pressure peak time variation. The observed attenuation effect in the pressure wave for high deformable pipe materials can be described by a combination of the non-elastic behaviour of the pipe-wall with steady and unsteady friction effects. Several simulations and experimental tests have been carried out. in order to analyse the dynamic response of single pipelines with different characteristics, such as pipe materials. diameters. thickness. lengths and transient conditions.
Resumo:
Este trabalho final de mestrado baseou-se no acompanhamento da construção do hotel SANA Amoreiras, situado na Avenida Duarte Pacheco nº 12. O empreiteiro geral foi a empresa FDO Construções. Existindo também uma equipa de fiscalização, LMSA, contratada pelo Dono de Obra de forma a efectuar todo o controlo de qualidade. O TFM baseou-se no estágio efectuado para o Dono de obra do hotel onde fui devidamente acompanhada por uma engenheira, orientadora de estágio, que acompanhou de perto o desempenho da minha actividade. Esta função teve como objectivos a gestão de projecto de hotel, interligação entre projectistas e empreiteiro geral, bem prestar o devido acompanhamento de todos trabalhos a realizar. Acompanhei a realização de dois quartos modelo onde o objectivo do Dono de Obra foi testar as diversas soluções ao nível de revestimentos, sanitários, iluminação, mobiliário, decoração e outras soluções de arquitectura, soluções estas a implementar no hotel. Acompanhei também a realização de reuniões de compatibilização e coordenação de todos os projectos de especialidades com o projecto de arquitectura, nomeadamente Avac, Instalações eléctricas, Comunicações, Segurança, Águas, Esgotos, Gás, Incêndio, Cozinhas de forma a ser possível efectuar consultas aos empreiteiros e adjudicar todas estas empreitadas. Foi efectuada uma abordagem à descrição do hotel, suas características, indicação das razões que levaram à sua construção e descrição das várias empreitadas de construção realizadas até então, tal como, demolição, escavação, estrutura, acabamentos e especialidades.
Resumo:
Nos dias que correm questões ambientais e considerações energéticas obrigam a uma inovação constante na procura de soluções de baixo consumo energético e de impacto ambiental baixo, nomeadamente no que diz respeito aos sistemas de climatização e refrigeração. Têm vindo a ser criadas medidas, tanto a nível internacional como nacional, no sentido de reduzir as emissões nocivas para a atmosfera, consequência do excessivo consumo de combustíveis fósseis, e do aumento da rentabilidade da energia e maior utilização de energias renováveis. O presente estudo de dimensionamento de um sistema de absorção, a brometo de lítio/água, com coletores solares, tem por base o sistema de compressão existente num edifício de serviços no centro de Lisboa. Foi efetuada uma analise simplificada dos seus dados de consumo energético, de maneira a verificar a viabilidade económica da substituição do equipamento existente e instalação de um sistema de coletores solares. Concluiu-se que a substituição do equipamento e a instalação de coletores solar, não é atrativa do ponto de vista económico, nesta solução em particular. Contudo, verifica-se uma considerável redução do impacto ambiental do consumo energético do edifício.
Resumo:
Advances in digital technology led to the development of digital x-ray detectors that are currently in wide use for projection radiography, including Computed Radiography (CR) and Digital Radiography (DR). Digital Imaging Systems for Plain Radiography addresses the current technological methods available to medical imaging professionals to ensure the optimization of the radiological process concerning image quality and reduction of patient exposure. Based on extensive research by the authors and reference to the current literature, the book addresses how exposure parameters influence the diagnostic quality in digital systems, what the current acceptable radiation doses are for useful diagnostic images, and at what level the dose could be reduced to maintain an accurate diagnosis. The book is a valuable resource for both students learning the field and for imaging professionals to apply to their own practice while performing radiological examinations with digital systems.
Resumo:
The assessment of patient dose has gained increased attention, still being an issue of concern that arises from the use of digital systems. The development of digital technology offers the possibility for a reduction of radiation dose around 50% without loss in image quality when compared to a conventional screen–film system. Digital systems give an equivalent or superior diagnostic performance and also several other advantages, but the risk of overexposure with no adverse effect on image quality could be present. This chapter refers to the management of patient dose and provides an explanation of dose-related concepts. In this chapter, exposure influence in dose and image representation and the effects of radiation exposure are also discussed.
Resumo:
Power converters play a vital role in the integration of wind power into the electrical grid. Variable-speed wind turbine generator systems have a considerable interest of application for grid connection at constant frequency. In this paper, comprehensive simulation studies are carried out with three power converter topologies: matrix, two-level and multilevel. A fractional-order control strategy is studied for the variable-speed operation of wind turbine generator systems. The studies are in order to compare power converter topologies and control strategies. The studies reveal that the multilevel converter and the proposed fractional-order control strategy enable an improvement in the power quality, in comparison with the other power converters using a classical integer-order control strategy. (C) 2010 Elsevier Ltd. All rights reserved.
Resumo:
Multilevel power converters have been introduced as the solution for high-power high-voltage switching applications where they have well-known advantages. Recently, full back-to-back connected multilevel neutral point diode clamped converters (NPC converter) have been used inhigh-voltage direct current (HVDC) transmission systems. Bipolar-connected back-to-back NPC converters have advantages in long-distance HVDCtransmission systems over the full back-to-back connection, but greater difficulty to balance the dc capacitor voltage divider on both sending and receiving end NPC converters. This study shows that power flow control and dc capacitor voltage balancing are feasible using fast optimum-predictive-based controllers in HVDC systems using bipolar back-to-back-connected five-level NPC multilevel converters. For both converter sides, the control strategytakes in account active and reactive power, which establishes ac grid currents in both ends, and guarantees the balancing of dc bus capacitor voltages inboth NPC converters. Additionally, the semiconductor switching frequency is minimised to reduce switching losses. The performance and robustness of the new fast predictive control strategy, and its capability to solve the DC capacitor voltage balancing problem of bipolar-connected back-to-back NPCconverters are evaluated.
Resumo:
Voltage source multilevel power converter structures are being considered for high power high voltage applications where they have well known advantages. Recently, full back-to-back connected multilevel neutral diode clamped converters (NPC) have been used in high voltage direct current (HVDC) transmission systems. Bipolar back-to-back connection of NPCs have advantages in long distance HVDC transmission systems, but highly increased difficulties to balance the dc capacitor voltage dividers on both sending and receiving end NPCs. This paper proposes a fast optimum-predictive controller to balance the dc capacitor voltages and to control the power flow in a long distance HVDCsystem using bipolar back-to-back connected NPCs. For both converter sides, the control strategy considers active and reactive power to establish ac grid currents on sending and receiving ends, while guaranteeing the balancing of both NPC dc bus capacitor voltages. Furthermore, the fast predictivecontroller minimizes the semiconductor switching frequency to reduce global switching losses. The performance and robustness of the new fast predictive control strategy and the associated dc capacitors voltage balancing are evaluated. (C) 2011 Elsevier B.V. All rights reserved.
Resumo:
In this paper, a novel mixed-integer nonlinear approach is proposed to solve the short-term hydro scheduling problem in the day-ahead electricity market, considering not only head-dependency, but also start/stop of units, discontinuous operating regions and discharge ramping constraints. Results from a case study based on one of the main Portuguese cascaded hydro energy systems are presented, showing that the proposedmixed-integer nonlinear approach is proficient. Conclusions are duly drawn. (C) 2010 Elsevier Ltd. All rights reserved.
Resumo:
Dedicated Short Range Communications (DSRC) is the key enabling technology for the present and future vehicular communication for various applications, such as safety improvement and traffic jam mitigation. This paper describes the development of a microstrip antenna array for the roadside equipment of a DSRC system, whose characteristics are according with the vehicular communications standards. The proposed antenna, with circular polarization, has a wide bandwidth, enough to cover the current European DSRC 5.8 GHz band and the future 5.9 GHz band for next generation DSRC communications. (C) 2011 Wiley Periodicals, Inc. Microwave Opt Technol Lett 53: 2794-2796, 2011; View this article online at wileyonlinelibrary.com. DOI 10.1002/mop.26394
Resumo:
This paper is concerned with the protection of wind energy systems against the indirect effects of lightning. As wind energy is gaining increasing importance throughout the world, lightning damages involving wind energy systems have come to be regarded with more attention. Nevertheless, there are still very few studies in Portugal regarding lightning protection of wind energy systems using models of the Electro-Magnetic Transients Program (EMTP). Hence, a new case study is presented in this paper, based on a wind turbine with an interconnecting transformer, considering that lightning strikes the soil near the tower at a distance such that galvanic coupling occurs through the grounding electrode. Computer simulations obtained by using EMTP-RV are presented and conclusions are duly drawn. (C) 2011 Elsevier Ltd. All rights reserved.
Resumo:
Although vaccination is still the most cost-effective strategy for tuberculosis control, there is an urgent need for an improved vaccine. Current BCG vaccine lacks efficacy in preventing adult pulmonary tuberculosis, the most prevalent form of the disease. Targeting nasal mucosa, Mycobacterium tuberculosis infection site, will allow a simpler, less prone to risk of infection and more effective immunization against disease. Due to its biodegradable, immunogenic and mucoadhesive properties, chitosan particulate delivery systems can act both as carrier and as adjuvant, improving the elicited immune response. In this study, BCG was encapsulated in alginate and chitosan microparticles, via a mild ionotropic gelation procedure with sodium tripolyphosphate as a counterion. The particulate system developed shows effective modulation of BCG surface physicochemical properties, suitable for mucosal immunization. Intracellular uptake was confirmed by effective transfection of human macrophage cell lines.
Resumo:
As coberturas planas são um dos principais elementos construtivos de uma edificação, necessitando por isso de materiais com qualidade e certificados por organismos competentes, bem como de uma conceção e execução minuciosas. Em Portugal, os estudos sobre as anomalias realmente observadas em coberturas planas são ainda bastante reduzidos. Nesse âmbito, o presente trabalho teve como objetivo, efetuar o levantamento e a análise estatística das principais anomalias e causas identificadas em coberturas planas de 75 edifícios, permitindo assim a elaboração de um estudo que possa contribuir para a prevenção dessas anomalias e que indique também as medidas necessárias à reparação e os respetivos custos associados. As anomalias foram analisadas através da observação "in situ" das coberturas o que conduziu ao preenchimento de fichas de obra com os dados recolhidos. Da análise estatística efetuada aos edifícios, verificou-se que as principais anomalias detetadas estão relacionadas com perfurações e fissurações do sistema impermeabilizante, resultantes da falta de conhecimento dos utilizadores. Foi possível verificar erros de execução de remates em pontos singulares da cobertura, por falta de pormenores construtivos desses pontos ou erros de execução por parte do aplicador. Em muitos dos casos estudados, não foi detetada nenhuma anomalia, porque se considerou razoável considerar que o sistema impermeabilizante tenha atingido o fim de vida útil. O custo médio por metro quadrado associado à reabilitação de uma cobertura plana é influenciado principalmente por dois fatores: área e acessibilidade da cobertura. O tipo de anomalia e/ou a sua causa não determinaram o custo por metro quadrado da reparação efetuada, pois esta foi sempre de caracter integral e nunca pontual.
Resumo:
Este Trabalho Final de Mestrado consiste num estágio que se encontra reportado neste relatório e que traduz o acompanhamento por parte do discente de uma empreitada de remodelação e reconversão de um edifício em Lisboa. O estágio com duração de seis meses desenvolveu-se entre Fevereiro e Julho de 2012 na empresa Arlindo Correia e Filhos, SA. Consistiu no acompanhamento da obra das futuras instalações da ASAE (Autoridade de Segurança Alimentar e Económica) na freguesia de São Mamede, concelho de Lisboa, sendo o orientador do estágio por parte da empresa, o Eng.º Vítor Soares, Director de Produção em causa. Os objectivos do estágio curricular visam a consolidação das matérias e temas abordados na vertente académica, assim como o contacto com a realidade do mundo laboral. A integração na empresa Arlindo Correia e Filhos SA e o acompanhamento regular das frentes de trabalho e de questões relacionadas com a obra, contribuíram de forma decisiva para cumprir com sucesso esta missão.
Resumo:
Os Hospitais, equipamentos de interesse público, são edifícios cujos desempenho e disponibilidade das suas instalações e equipamentos podem comprometer a prestação de cuidados de saúde, pelo que nestes estabelecimentos, a Manutenção Preventiva assume um papel relevante. Nesse sentido, pretendeu-se nesta dissertação definir uma estratégia específica que permita efectuar o planeamento da manutenção preventiva de um edifício hospitalar, enquanto infraestrutura para desenvolvimento da actividade clínica. Para tal, foi efectuada uma pesquisa bibliográfica, com a qual se identificaram conceitos de manutenção e requisitos a serem tidos em conta na manutenção de edifícios hospitalares. Foi efectuada uma caracterização genérica do objecto de manutenção, limitada no âmbito desta dissertação às principais componentes dos sistemas de construção e das instalações de águas e esgotos, que podem integrar um edifício hospitalar actual, atendendo às especificações e recomendações técnicas vigentes para este tipo de edifícios. Foram identificados os objectivos e requisitos de manutenção nestes edifícios, estabelecidos pelas condições de funcionamento pretendidas, pelos critérios de durabilidade exigidos pelo Dono de Obra, pelo nível de desempenho funcional requerido para as suas componentes e pelo grau de operacionalidade imposto nas suas diferentes unidades funcionais. Tendo em consideração que a criticidade de uma componente não depende só do contexto operacional da área funcional em se insere mas também das consequências que o seu estado de funcionamento pode acarretar para a unidade funcional. Foi exemplificada a análise dos modos de falha, sua criticidade e seus efeitos para hierarquização do risco associado nas componentes estudadas. As fichas exemplificativas dos planos de manutenção preventiva, que se apresentam no âmbito desta dissertação para algumas componentes básicas, integram acções e procedimentos que derivam de uma análise aos seus modos de falha e seus efeitos, bem como de recomendações técnicas exigências da regulamentação em vigor.