18 resultados para 940.2
Resumo:
This letter reports on the magnetic properties of Ti(1-x)Co(x)O(2) anatase phase nanopowders with different Co contents. It is shown that oxygen vacancies play an important role in promoting long-range ferromagnetic order in the material studied in addition to the transition-metal doping. Furthermore, the results allow ruling out the premise of a strict connection between Co clustering and the ferromagnetism observed in the Co:TiO(2) anatase system.
Resumo:
Introdução – A técnica de Difusão por Ressonância Magnética (RM), ao avaliar o movimento das moléculas de água nos tecidos, permite inferir sobre a arquitetura dos mesmos, em particular relativamente à celularidade, volume celular e permeabilidade das membranas. O Coeficiente de Difusão Aparente (ADC) é um parâmetro quantificável da imagem ponderada em difusão (DWI). A sua análise poderá fornecer informação clínica adicional sobre estas lesões, sobretudo em relação à sua caracterização histológica. Objetivos – Caracterizar e diferenciar tipos e alguns subtipos de lesões mamárias através da análise do ADC. Metodologia – 20 Mulheres com 23 lesões mamárias foram submetidas a RM mamária: 3 lesões benignas (3 Fibroadenomas-FA) e 20 malignas (16 Carcinomas Ductais Invasivos-CDI, 2 Carcinomas Ductais In Situ-CDIS e 2 Carcinomas Invasivos Lobulares-CLI). Num equipamento 1.5T aplicou-se uma sequência de Difusão (b=0,50,250,500,750,1000 s/mm2). Obteve-se o ADC através do ajuste exponencial da intensidade de sinal das lesões em função do valor de b, fazendo-se corresponder os valores de ADC à respetiva caracterização histológica e posterior comparação com a literatura. Resultados e Discussão – As lesões malignas apresentaram ADCs significativamente (p=0,014) inferiores [(0,94±0,22)x10-3 mm2/s] aos das benignas [(1,43±0,25)x10-3 mm2/s]. A justificação pode residir no aumento da celularidade e consequente restrição da Difusão que se observa nas lesões malignas. Os CDI apresentaram ADCs baixos [(0,88±0,17)x10-3 mm2/s], enquanto que os CDIS apresentaram ADCs mais elevados [(1,33±0,29)x10-3 mm2/s]. Estes resultados estão de acordo com o facto dos CDIS estarem limitados aos ductos mamários, mantendo-se menos alterada a estrutura do tecido adjacente e resultando numa menor restrição à difusão que nos CDI. Verificaram-se diferenças significativas entre FA e CDI (p=0,010) e entre CDI e CDIS (p=0,049). Conclusões – O ADC possibilita a diferenciação entre lesões mamárias benignas e malignas, bem como entre alguns tipos histológicos. O desenvolvimento deste conceito pode representar um avanço no papel da RM na avaliação destas neoplasias. ABSTRACT - Introduction – The Magnetic Resonance (MR) diffusion technique measures the movement of water molecules in tissues. Therefore, it provides useful information about tissue architecture, specially regarding tissue cellularity, cell volume and membrane permeability. The quantification of diffusion weighted imaging (DWI) data is done by measuring the so-called. Apparent Diffusion Coefficient (ADC). This parameter provides additional clinical information about breast lesions, and potentially allows for in-vivo histological characterization. Purpose – To characterize and differentiate breast lesions through ADC analysis. Methodology – The study comprised 20 women, with 23 breast lesions: 3 benign lesions - 3 Fibroadenomas (FA); and 20 malignant - 16 Invasive Ductal Carcinomas (CDI), 2 Ductal Carcinomas In Situ (CDIS), 2 Invasive Lobular Carcinoma (CLI). On a 1.5T equipment a diffusion-weighted sequence with 6 b-values (b=0,50,250,500,750,1000 s/mm2) was used to examine the patients. ADC was obtained by fitting an exponential to data of lesion signal intensity vs. b values. A correspondence of ADC values to histological lesion characterization was done and finally, the results were comparison with the literature. Results and Discussion – Malignant lesions showed inferior ADCs significantly (p=0.014) lower ((0.94±0.22)x10-3 mm2/s) than the benign lesions ((1.43±0.25)x10-3 mm2/s). This may be associated to increasead cellularity in malignant lesions, which result in higher tissue restriction to diffusion. CDI showed low ADC values ((0.88±0.17)x10-3 mm2/s), while the CDIS showed higher ADCs ((1.33±0.29)x10-3 mm2/s). These results agree with the fact that CDIS are limited to mammary ducts, maintaining a less altered neighboring tissue structure, which results in a lower restriction to diffusion than observed in CDI. Significant differences between FA and CDI (p=0.010) and between CDI and CDIS (p=0.049) were observed. Conclusion – The ADC parameter is able to differentiate between malignant and benign breast lesions, as well as between some histological types.
Resumo:
Com o surgimento de novos sistemas de telecomunicações sem fios, que necessitam de maiores potências de emissão e largura de banda disponível, surgem os regulamentos que controlam as emissões rádio. Só assim estas tecnologias podem coexistir em bandas próximas, com o máximo desempenho e com a garantia que os níveis de poluição electromagnética não são ultrapassados. Cada vez mais, regulamentos que limitam a potência da transmissão têm em vista questões de saúde pública e por isso devem ser estritamente respeitados. Para se poder controlar as emissões rádio é necessário um dispositivo que consiga analisar o espectro rádio. Um dos instrumentos fundamentais na metrologia de radiofrequência é o analisador de espectros, que tem como principal função apresentar a potência de porções do espectro em função da frequência. Existem vários tipos de analisadores espectrais, que se baseiam em arquitecturas de recepção distintas. O tipo de analisador define a sua complexidade e o tipo de análises que consegue fazer. Com esta dissertação pretende-se mostrar a implementação de um analisador de espectro portátil, de baixo custo, baseado num receptor heteródino e com uma frequência de operação compreendida entre os 2 e os 3 GHz. Este projecto abrange diversas áreas, desde o hardware de recepção rádio, passando pelo microcontrolador que faz a aquisição de dados e comunicação com o computador, acabando na aplicação que foi desenvolvida em Java para permitir ao utilizador uma interface de utilização simples e funcional. Foi também desenvolvida com sucesso uma antena impressa adequada à banda de frequência referida. Embora tenham existidos problemas simples, um na localização do filtro passa-banda e o outro na resposta do filtro intermédio, os objectivos foram alcançados obtendo-se um analisador de espectro portátil, funcional e de baixo custo, conforme pretendido. O analisador tem um erro máximo na detecção de potência de 2,5 dB e o tempo de varrimento máximo é cerca de 16 segundos com 500 pontos de resolução. Foram realizadas várias medições e uma comparação com um analisador de espectros comercial, para demonstrar o funcionamento e desempenho do analisador desenvolvido, tendo os resultados sido bastante promissores. A funcionalidade deste analisador medir a potência do sinal ao longo do tempo é uma mais-valia face ao analisador comercial utilizado para a comparação.