34 resultados para STANDARD REFERENCE INTERVALS


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Purpose: To investigate whether standard X-ray acquisition factors for orbital radiographs are suitable for the detection of ferromagnetic intra-ocular foreign bodies in patients undergoing MRI. Method: 35 observers, at varied levels of education in radiography, attending a European Dose Optimisation EURASMUS Summer School were asked to score 24 images of varying acquisition factors against a clinical standard (reference image) using two alternative forced choice. The observers were provided with 12 questions and a 5 point Likert scale. Statistical tests were used to validate the scale, and scale reliability was also measured. The images which scored equal to, or better than, the reference image (36) were ranked alongside their corresponding effective dose (E), the image with the lowest dose equal to or better than the reference is considered the new optimum acquisition factors. Results: Four images emerged as equal to, or better than, the reference in terms of image quality. The images were then ranked in order of E. Only one image that scored the same as the reference had a lower dose. The reference image had a mean E of 3.31μSv, the image that scored the same had an E of 1.8μSv. Conclusion: Against the current clinical standard exposure factors of 70kVp, 20mAs and the use of an anti- scatter grid, one image proved to have a lower E whilst maintaining the same level of image quality and lesion visibility. It is suggested that the new exposure factors should be 60kVp, 20mAs and still include the use of an anti-scatter grid.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In Part I of the present work we describe the viscosity measurements performed on tris(2-ethylhexyl) trimellitate or 1,2,4-benzenetricarboxylic acid, tris(2-ethylhexyl) ester (TOTM) up to 65 MPa and at six temperatures from (303 to 373)K, using a new vibrating-wire instrument. The main aim is to contribute to the proposal of that liquid as a potential reference fluid for high viscosity, high pressure and high temperature. The present Part II is dedicated to report the density measurements of TOTM necessary, not only to compute the viscosity data presented in Part I, but also as complementary data for the mentioned proposal. The present density measurements were obtained using a vibrating U-tube densimeter, model DMA HP, using model DMA5000 as a reading unit, both instruments from Anton Paar GmbH. The measurements were performed along five isotherms from (293 to 373)K and at eleven different pressures up to 68 MPa. As far as the authors are aware, the viscosity and density results are the first, above atmospheric pressure, to be published for TOTM. Due to TOTM's high viscosity, its density data were corrected for the viscosity effect on the U-tube density measurements. This effect was estimated using two Newtonian viscosity standard liquids, 20 AW and 200 GW. The density data were correlated with temperature and pressure using a modified Tait equation. The expanded uncertainty of the present density results is estimated as +/- 0.2% at a 95% confidence level. Those results were correlated with temperature and pressure by a modified Tait equation, with deviations within +/- 0.25%. Furthermore, the isothermal compressibility, K-T, and the isobaric thermal expansivity, alpha(p), were obtained by derivation of the modified Tait equation used for correlating the density data. The corresponding uncertainties, at a 95% confidence level, are estimated to be less than +/- 1.5% and +/- 1.2%, respectively. No isobaric thermal expansivity and isothermal compressibility for TOTM were found in the literature. (C) 2014 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Tris(2-ethylhexyl) trimellitate (TOTM) was recently suggested as a reference fluid for industrial use associated with high viscosity at elevated temperature and pressure. Viscosity and density data have already been published on one sample covering the temperature range (303-373) K and at pressures up to about 65 MPa. The viscosity covered a range from about (9 to 460) mPa s. In the present article we study several other characteristics of TOTM that must be available if it were to be adopted as a standard. First, we present values for the viscosity and density obtained with a different sample of TOTM to examine the important feature of consistency among different samples. Vibrating-wire viscosity measurements were performed at pressures from (5 to 100) MPa, along 6 isotherms between (303 and 373) K. Density measurements were carried out from (293 to 373) K up to 68 MPa, along 4 isotherms, using an Anton Paar DMA HP vibrating U-tube densimeter. Secondly, we report a study of the effect of water contamination on the viscosity of TOTM, performed using an Ubbelhode viscometer under atmospheric pressure. Finally, in order to support the use of TOTM as a reference liquid for the calibration of capillary viscometers, values of its surface tension, obtained by the pendant drop method, are provided. (C) 2016 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study aimed to determine and evaluate the diagnostic accuracy of visual screening tests for detecting vision loss in elderly. This study is defined as study of diagnostic performance. The diagnostic accuracy of 5 visual tests -near convergence point, near accommodation point, stereopsis, contrast sensibility and amsler grid—was evaluated by means of the ROC method (receiver operating characteristics curves), sensitivity, specificity, positive and negative likelihood ratios (LR+/LR−). Visual acuity was used as the reference standard. A sample of 44 elderly aged 76.7 years (±9.32), who were institutionalized, was collected. The curves of contrast sensitivity and stereopsis are the most accurate (area under the curves were 0.814−p = 0.001, C.I.95%[0.653;0.975]— and 0.713−p = 0.027, C.I.95%[0,540;0,887], respectively). The scores with the best diagnostic validity for the stereopsis test were 0.605 (sensitivity 0.87, specificity 0.54; LR+ 1.89, LR−0.24) and 0.610 (sensitivity 0.81, specificity 0.54; LR+1.75, LR−0.36). The scores with higher diagnostic validity for the contrast sensibility test were 0.530 (sensitivity 0.94, specificity 0.69; LR+ 3.04, LR−0.09). The contrast sensitivity and stereopsis test's proved to be clinically useful in detecting vision loss in the elderly.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fungal contamination of air in 10 gymnasiums with swimming pools was monitored. Fifty air samples of 200 L each were collected, using a Millipore air tester, from the area surrounding the pool, in training studios, in showers and changing rooms for both sexes, and also, outside premises, since these are the places regarded as reference. Simultaneously, environmental parameters – temperature and humidity – were also monitored. Some 25 different species of fungi were identified. The six most commonly isolated genera were the following: Cladosporium sp. (36.6%), Penicillium sp. (19.0%), Aspergillus sp. (10.2%), Mucor sp. (7%), Phoma sp. and Chrysonilia sp. (3.3%). For yeasts, three different genera were identified, namely, Rhodotorula sp. (70%), Trichosporon mucoides and Cryptococcus uniguttulattus (10%).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A descriptive study was developed to monitor air fungal contamination in two elementary schools in Lisbon, Portugal. Eight air samples of 250 litres through impaction method were collected in canteen, library, classrooms and also, outside premises as reference place. Simultaneously, were also monitored environmental parameters, including temperature, and humidity through the equipment Babouc, LSI Sistems and according to the International Standard ISO 7726 - 1998. Considering both schools, sixteen different species of fungi in air were identified, being the 2 most commonly isolated Cladosporium sp. (51,1%) and Penicillium sp. (27,5%). Besides these genera Trichoderma, Aspergillus, Alternaria, Chrysonilia, Botritys, Ulocladium, Athrium, Aureobasidium, Phoma, Scedosporium e Geotrichum were also isolated. Regarding yeasts, Candida sp., Cryptococcus sp. and Rhodotorula sp. were isolated. The youngest school, as well canteens in each school, presented the worst results concerning the air fungal contamination, maybe due to the higher number of occupants. There was no significant relationship (p>0,05) between fungal contamination and temperature and humidity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Do ponto de vista das preocupações de saúde, os níveis de contaminação do ar interior assumem actualmente uma elevada importância quando se tem em consideração que as pessoas passam a maior parte do seu tempo no interior de edifícios. Neste contexto, o formaldeído é um dos poluentes mais preocupantes e, inclusivamente, os resultados de concentração obtidos em habitações do espaço Europeu foram considerados preocupantes devido ao facto de estarem relacionados com efeitos negativos para a saúde. O estudo exploratório desenvolvido pretendeu disponibilizar informação acerca das concentrações de formaldeído existentes em habitações domésticas portuguesas. Estudou‑se a presença de formaldeído em habitações novas e habitações domésticas com ocupação, abrangendo 6 unidades de cada um dos tipos considerados. Para a avaliação ambiental foi utilizado um equipamento de leitura direta que deteta as concentrações de formaldeído por fotoionização com uma lâmpada de 11,7 eV. A temperatura ambiente e a humidade relativa foram igualmente medidas, de acordo com o estipulado na Norma Internacional ISO 7726:1998. No caso das habitações novas foram registados valores de concentração superiores a 0,08 ppm em 3 das unidades estudadas. Por outro lado, em 4 das habitações com ocupação foram obtidos valores superiores a 0,08 ppm. O desenvolvimento deste estudo permitiu reconhecer algumas das possíveis fontes emissoras e os factores que influenciam as concentrações de formaldeído nas habitações em Portugal. ABSTRACT - Nowadays, indoor air contamination is considering an important health issue considering that people spend most of their time indoors. In this context, formaldehyde is a pollutant of major concern and, recently, concentration results obtained in European dwellings reveal high concentrations and values related with negative health effects in occupants. The present exploratory study sought to provide information about formaldehyde concentrations in Portuguese dwellings. It was studied formaldehyde presence in new dwellings and dwellings with occupation and included 6 units of each setting. For concentrations measure, it was used a direct‑reading equipment that detects formaldehyde concentration by photoionization. Temperature and relative humidity were also measured in accordance with International Standard ISO 7726:1998. In the case of new dwellings, in 3 units concentration values were higher than 0.08 ppm. In addition, in 4 units of the 6 dwellings with occupation, concentrations higher than this reference value were obtained. The development of this study permitted to recognize some of the possible indoors emissions sources and to define several of the preventive measures that can be applied.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The exposure index (lgM) obtained from a radiographic image may be a useful feedback indicator to the radiographer about the appropriate exposure level in routine clinical practice. This study aims to evaluate lgM in orthopaedic radiography performed in the standard clinical environment. We analysed the lgM of 267 exposures performed with an AGFA CR system. The mean value of lgM in our sample is 2.14. A significant difference (P=0.000<0.05) from 1.96 lgM reference is shown. Data show that 72% of exposures are above the 1.96 lgM and 42% are above the limit of 2.26. Median values of lgM are above 1.96 and below 2.26 for Speed class (SC) 200 (2.16) and SC400 (2.13). The interquartile range is lower in SC400 than in SC200. Data seem to indicate that lgM values are above the manufacturer’s reference of 1.96. Departmental exposure charts should be optimised to reduce the dose given to patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A descriptive study was developed to monitor air fungal contamination in ten food units from hospitals. Fifty air samples of 250 litres were collected through impaction method. Samples were collected in food storage facilities, kitchen, food plating, canteen and also, outside premises, since this is the place regarded as reference. Simultaneously, environmental parameters were also monitored, including temperature and relative humidity through the equipment Babouc, LSI Sistems and according to the International Standard ISO 7726.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Recently, several distributed video coding (DVC) solutions based on the distributed source coding (DSC) paradigm have appeared in the literature. Wyner-Ziv (WZ) video coding, a particular case of DVC where side information is made available at the decoder, enable to achieve a flexible distribution of the computational complexity between the encoder and decoder, promising to fulfill novel requirements from applications such as video surveillance, sensor networks and mobile camera phones. The quality of the side information at the decoder has a critical role in determining the WZ video coding rate-distortion (RD) performance, notably to raise it to a level as close as possible to the RD performance of standard predictive video coding schemes. Towards this target, efficient motion search algorithms for powerful frame interpolation are much needed at the decoder. In this paper, the RD performance of a Wyner-Ziv video codec is improved by using novel, advanced motion compensated frame interpolation techniques to generate the side information. The development of these type of side information estimators is a difficult problem in WZ video coding, especially because the decoder only has available some reference, decoded frames. Based on the regularization of the motion field, novel side information creation techniques are proposed in this paper along with a new frame interpolation framework able to generate higher quality side information at the decoder. To illustrate the RD performance improvements, this novel side information creation framework has been integrated in a transform domain turbo coding based Wyner-Ziv video codec. Experimental results show that the novel side information creation solution leads to better RD performance than available state-of-the-art side information estimators, with improvements up to 2 dB: moreover, it allows outperforming H.264/AVC Intra by up to 3 dB with a lower encoding complexity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present paper shows preliminary results of an ongoing project which one of the goals is to investigate the viability of using waste FCC catalyst (wFCC), originated from Portuguese oil refinery, to produce low carbon blended cements. For this purpose, four blended cements were produced by substituting cement CEM I 42.5R up to 20% (w/w) by waste FCC catalyst. Initial and final setting times, consistency of standard paste, soundness and compressive strengths after 2, 7 and 28 days were measured. It was observed that the wFCC blended cements developed similar strength, at 28 days, compared to the reference cement, CEM I 42.5R. Moreover, cements with waste FCC catalyst incorporation up to 15% w/w meet European Standard EN 197-1 specifications for CEM II/A type cement, in the 42.5R strength class.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We study the implications of the searches based on H -> tau(+)tau-by the ATLAS and CMS collaborations on the parameter space of the two-Higgs-doublet model (2HDM). In the 2HDM, the scalars can decay into a tau pair with a branching ratio larger than the SM one, leading to constraints on the 2HDM parameter space. We show that in model II, values of tan beta > 1.8 are definitively excluded if the pseudoscalar is in the mass range 110 GeV < m(A) < 145 GeV. We have also discussed the implications for the 2HDM of the recent dimuon search by the ATLAS collaboration for a CP-odd scalar in the mass range 4-12 GeV.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper we are concerned with the role played by adverbials in the construction of reference in children's narratives.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Monte Carlo (MC) dose calculation algorithms have been widely used to verify the accuracy of intensity-modulated radiotherapy (IMRT) dose distributions computed by conventional algorithms due to the ability to precisely account for the effects of tissue inhomogeneities and multileaf collimator characteristics. Both algorithms present, however, a particular difference in terms of dose calculation and report. Whereas dose from conventional methods is traditionally computed and reported as the water-equivalent dose (Dw), MC dose algorithms calculate and report dose to medium (Dm). In order to compare consistently both methods, the conversion of MC Dm into Dw is therefore necessary. This study aims to assess the effect of applying the conversion of MC-based Dm distributions to Dw for prostate IMRT plans generated for 6 MV photon beams. MC phantoms were created from the patient CT images using three different ramps to convert CT numbers into material and mass density: a conventional four material ramp (CTCREATE) and two simplified CT conversion ramps: (1) air and water with variable densities and (2) air and water with unit density. MC simulations were performed using the BEAMnrc code for the treatment head simulation and the DOSXYZnrc code for the patient dose calculation. The conversion of Dm to Dw by scaling with the stopping power ratios of water to medium was also performed in a post-MC calculation process. The comparison of MC dose distributions calculated in conventional and simplified (water with variable densities) phantoms showed that the effect of material composition on dose-volume histograms (DVH) was less than 1% for soft tissue and about 2.5% near and inside bone structures. The effect of material density on DVH was less than 1% for all tissues through the comparison of MC distributions performed in the two simplified phantoms considering water. Additionally, MC dose distributions were compared with the predictions from an Eclipse treatment planning system (TPS), which employed a pencil beam convolution (PBC) algorithm with Modified Batho Power Law heterogeneity correction. Eclipse PBC and MC calculations (conventional and simplified phantoms) agreed well (<1%) for soft tissues. For femoral heads, differences up to 3% were observed between the DVH for Eclipse PBC and MC calculated in conventional phantoms. The use of the CT conversion ramp of water with variable densities for MC simulations showed no dose discrepancies (0.5%) with the PBC algorithm. Moreover, converting Dm to Dw using mass stopping power ratios resulted in a significant shift (up to 6%) in the DVH for the femoral heads compared to the Eclipse PBC one. Our results show that, for prostate IMRT plans delivered with 6 MV photon beams, no conversion of MC dose from medium to water using stopping power ratio is needed. In contrast, MC dose calculations using water with variable density may be a simple way to solve the problem found using the dose conversion method based on the stopping power ratio.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Several activities are ensured by dockers increase occupational exposure to several risk factors. being one of them the fungal burden from the load. In this study we aim at characterizing fungal contamination in one warehouse that storage sugar cane from a ship, and also in one crane cabinet that unload the same sugar cane from the ship. Air samples were collected from the warehouse and from inside the crane cabinet. An outdoor sample was also collected, from each sampling site, and regarding as reference. Sampling volume was selected depending in the contamination expected and the air samples were collect through an impaction method in a flow rate of 140 L/min onto malt extract agar (MEA) supplemented with chloramphenicol (0.05%), using the Millipore air Tester (Millipore). Surfaces samples from the warehouse were collected by swabbing the surfaces of the same indoor sites, using a 10 by 10cm square stencil according to the International Standard ISO 18593 (2004). The obtained swabs were then plated onto MEA. All the collected samples were incubated at 27ºC for 5 to 7 days. After laboratory processing and incubation of the collected samples, quantitative (colony-forming units - CFU/m3 and CFU/m2) and qualitative results were obtained with identification of the isolated fungal species. Aspergillus fumigatus present the highest fungal load and WHO guideline was overcome in both indoor sampling sites. The results obtained in this study highlight the need to know better the exposure burden from dockers, and specifically to fungi contamination.