2 resultados para the scanning reference electrode technique

em CiencIPCA - Instituto Politécnico do Cávado e do Ave, Portugal


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Although the 12-lead electrocardiogram has become an essential medical and research tool, many current and envisaged applications would benefit from simpler devices, using 3-lead ECG configuration. This is particularly true for Ambient Assisted Living (in a broad perspective). However, the chest anatomy of female patients, namely during pregnancy, can hamper the adequate placement of a 3-lead ECG device and, very often, electrodes are placed below the chest rather than at the precise thoracic landmarks. Thus, the aim of this study was to compare the effect of electrode positioning on the ECG signal of pregnant women and provide guidelines for device development. The effect of breast tissue on the ECG signal was investigated by relating breast size with the signal-to-noise ratio, root mean square and R-wave amplitude. Results show that the 3-lead ECG should be placed on the breast rather than under the breast and indicate positive correlation between breast size and signal-to-noise ratio.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Several studies link the seamless fit of implant-supported prosthesis with the accuracy of the dental impression technique obtained during acquisition. In addition, factors such as implant angulation and coping shape contribute to implant misfit. Purpose: The aim of this study was to identify the most accurate impression technique and factors affecting the impression accuracy. Material and Methods: A systematic review of peer-reviewed literature was conducted analyzing articles published between 2009 and 2013. The following search terms were used: implant impression, impression accuracy, and implant misfit.A total of 417 articles were identified; 32 were selected for review. Results: All 32 selected studies refer to in vitro studies. Fourteen articles compare open and closed impression technique, 8 advocate the open technique, and 6 report similar results. Other 14 articles evaluate splinted and non-splinted techniques; all advocating the splinted technique. Polyether material usage was reported in nine; six studies tested vinyl polysiloxane and one study used irreversible hydrocolloid. Eight studies evaluated different copings designs. Intraoral optical devices were compared in four studies. Conclusions: The most accurate results were achieved with two configurations: (1) the optical intraoral system with powder and (2) the open technique with splinted squared transfer copings, using polyether as impression material.